Comparison of precision for the Kodak Ektachem 400 and Technicon AutoAnalyzer II creatinine methods.

Abstract:

:We have evaluated the precision of the Ektachem 400 thin film enzymic creatinine method and compared it to that obtained for an AutoAnalyzer II (AAII) picric acid procedure. The results of the study show that the Ektachem method yields imprecise creatinine values over the low concentration range (40-240 mumol/L). Run-to-run precision estimates at a creatinine concentration of 225 mumol/L (by AAII) yielded CV's of 9.3 and 2.6% for the Ektachem 400 and AutoAnalyzer II methods respectively. The Ektachem 400 yielded imprecise creatinine determinations even when sample ammonia concentrations were less than 150 mumol/L. Patient samples analyzed by the AAII and Ektachem 400 over the creatinine range 40-900 mumol/L were highly correlated (r = 0.994). The correlation (r = 0.779) was low for patient data over the creatinine range 40-160 mumol/L. Creatinine results determined by the Ektachem 400 showed improved precision when samples were evaluated in triplicate using Kodak's latest (No. 8.5) software revision.

journal_name

Clin Biochem

journal_title

Clinical biochemistry

authors

Jacklyn CL,Matte SJ,Ryder DI,Cousins CL,Moss MA

doi

10.1016/s0009-9120(85)80072-2

subject

Has Abstract

pub_date

1985-12-01 00:00:00

pages

342-4

issue

6

eissn

0009-9120

issn

1873-2933

pii

S0009-9120(85)80072-2

journal_volume

18

pub_type

杂志文章
  • Detection of BRAF-V600E and V600K in melanoma circulating tumour cells by droplet digital PCR.

    abstract:OBJECTIVES:Defining the BRAF mutation status in metastatic melanoma patients is critical to selecting patients for therapeutic treatment with targeted therapies. Circulating tumour cells (CTCs) can provide an alternative source of contemporaneous tumour genetic material. However methodologies to analyse the presence of...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2014.12.007

    authors: Reid AL,Freeman JB,Millward M,Ziman M,Gray ES

    更新日期:2015-10-01 00:00:00

  • Comparison of fluorescent immunoassay (FIA) and enzyme-multiplied immunoassay technique (EMIT) for measurement of serum carbamazepine concentration.

    abstract::The recently developed fluorescent immunoassay (FIA) for measuring serum carbamazepine concentration is compared to the established enzyme-multiplied-immunoassay-technique (EMIT). The Accuracy, precision and simplicity of these methods are comparable. The sensitivity of FIA is approximately eight times greater than th...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/s0009-9120(82)96854-0

    authors: Carl GF,Smith DB,Dunn LP

    更新日期:1982-12-01 00:00:00

  • Analytical evaluation of the testosterone assay on the Bayer Immuno 1 system.

    abstract:OBJECTIVES:To evaluate the analytical performance of the testosterone assay performed on the Bayer immuno 1 system from Bayer Corporation. DESIGN AND METHODS:The precision was measured using three Bayer TESTpoint Ligand controls, three Medical Decision Pools and the Bayer SETpoint Testosterone calibrators. The lineari...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/s0009-9120(97)00140-9

    authors: Lévesque A,Letellier M,Swirski C,Lee C,Grant A

    更新日期:1998-02-01 00:00:00

  • Cox proportional hazard model analysis of survival in end-stage renal disease patients with small-sized high-density lipoprotein particles.

    abstract:OBJECTIVE:Dyslipidemia is commonly seen in patients with end-stage renal disease (ESRD). This prospective study investigates whether small-sized high-density lipoprotein (HDL) particles alone or in combination with high sensitivity C-reactive protein (hsCRP) are independent determinants of ESRD mortality. DESIGN AND M...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2011.02.002

    authors: Vekic J,Zeljkovic A,Bogavac-Stanojevic N,Jelic-Ivanovic Z,Spasojevic-Kalimanovska V,Simic-Ogrizovic S,Dopsaj V,Spasic S

    更新日期:2011-06-01 00:00:00

  • Ghrelin and glucoregulatory hormone responses to a single circuit resistance exercise in male college students.

    abstract:INTRODUCTION:It has been suggested that ghrelin may play a role in growth hormone (GH) secretion to exercise. OBJECTIVE:The present study was designed to examine the effects of a single bout of circuit resistance exercise on plasma glucose, ghrelin, GH, and c-peptide, and cortisol. DESIGN AND METHODS:Fourteen volunte...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2006.05.009

    authors: Ghanbari-Niaki A

    更新日期:2006-10-01 00:00:00

  • Transthyretin as a marker to predict outcome in critically ill patients.

    abstract:BACKGROUND:A determination of serum Transthyretin (TTR, Prealbumin) level is an objective method of assessing protein catabolic loss of severely ill patients and numerous studies have shown that TTR levels correlate with patient outcomes of non-critically ill patients. We evaluated whether TTR level correlates with the...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2008.06.016

    authors: Devakonda A,George L,Raoof S,Esan A,Saleh A,Bernstein LH

    更新日期:2008-10-01 00:00:00

  • The clinical relevance of imatinib plasma trough concentrations in chronic myeloid leukemia. A Belgian study.

    abstract::This retrospective multicenter study in patients with chronic myeloid leukemia in chronic phase was undertaken to confirm the clinical relevance of imatinib plasma concentrations monitoring in daily practice. Forty-one patients, with 47 imatinib plasma measurements, were analyzed during treatment with imatinib given a...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章,多中心研究

    doi:10.1016/j.clinbiochem.2016.12.006

    authors: Van Obbergh F,Knoops L,Devos T,Beguin Y,Graux C,Benghiat F,Kargar-Samani K,Bauwens D,Efira A,Dubois C,Springael C,Montfort L,Connerotte T,Capron A,Delannoy A,Wallemacq P

    更新日期:2017-05-01 00:00:00

  • High-throughput online solid-phase extraction tandem mass spectrometry: Is it right for your clinical laboratory?

    abstract::With increasing patient volumes and growing demands for rapid turnaround on many clinical tests, there is a demand for high-throughput technologies. High-Throughput Online Solid-Phase Extraction Tandem Mass Spectrometry is an example of one technology that can achieve these desired results and the RapidFire 365 Mass S...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2016.04.012

    authors: Jannetto PJ,Langman LJ

    更新日期:2016-09-01 00:00:00

  • Enzyme linked lectin assay (ELLA) for direct analysis of transferrin sialylation in serum samples.

    abstract:OBJECTIVES:Glycosylation analysis provides many opportunities for diagnostics, but its complexity hampers its routine application. Aiming to alleviate this problem, we developed a simple assay that can measure sialylation of transferrin directly from serum. DESIGN AND METHODS:Transferrin samples with different levels ...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2007.01.010

    authors: Gornik O,Lauc G

    更新日期:2007-06-01 00:00:00

  • Val-9Ala and Ile+58Thr polymorphism of MnSOD in Parkinson's disease.

    abstract:OBJECTIVES:To investigate the polymorphism distribution of Val-9Ala and Ile+58Thr of the Mn-superoxide dismutase (Mn-SOD) gene among subjects with Parkinson's disease (PD) by analyses of genders and clinical severity. DESIGN AND METHODS:We examined the DNA genotypes of Val-9Ala and Ile+58Thr from 295 PD subjects and 1...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2010.05.009

    authors: Wang V,Chen SY,Chuang TC,Shan DE,Soong BW,Kao MC

    更新日期:2010-08-01 00:00:00

  • The Italian pilot external quality assessment program for cystic fibrosis sweat test.

    abstract:OBJECTIVES:Sweat chloride test is the gold standard test for cystic fibrosis (CF) diagnosis. In 2014 the Istituto Superiore di Sanità established the Italian pilot external quality assessment program for CF sweat test (IEQA-ST). DESIGN AND METHODS:Ten laboratories, included among the 33 Italian CF Referral Centers, we...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2015.12.014

    authors: Salvatore M,Floridia G,Amato A,Censi F,Carta C,de Stefano MC,Ferrari G,Tosto F,Capoluongo E,Caruso U,Castaldo G,Cirilli N,Corbetta C,Padoan R,Raia V,Taruscio D

    更新日期:2016-05-01 00:00:00

  • Precipitation method for separating and quantifying bone and liver alkaline phosphatase isoenzymes.

    abstract::We evaluated a method for quantifying bone isoenzyme of alkaline phosphatase (ALP) which utilizes wheat-germ lectin to precipitate this fraction. In precision studies, CVs ranged from 3.2 to 11.4% (within-day) and from 3.7 to 11.5% (day-to-day). The assay procedure was linear to 1100 U/L and was easily adapted to auto...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/s0009-9120(05)80017-7

    authors: Burlina A,Plebani M,Secchiero S,Zaninotto M,Sciacovelli L

    更新日期:1991-10-01 00:00:00

  • Homozygous bisalbuminemia or homozygous mutant albumin?

    abstract:INTRODUCTION:Bisalbuminemia is a genetic condition in which an albumin variant is found in serum in addition to normal albumin. METHODS AND MATERIALS:Serum protein electrophoresis using the Sebia HYDRASYS electrophoresis system was performed on an 84 year old male. RESULTS:Serum protein electrophoresis showed a singl...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2011.10.005

    authors: Kulkarni K,Rowe P,Christensen CL,Higgins T

    更新日期:2012-01-01 00:00:00

  • Lactase persistence versus lactose intolerance: Is there an intermediate phenotype?

    abstract:BACKGROUND:According to the prevailing theory about the genetic background to lactose intolerance, there are three genotypes but only two adult physiological phenotypes: lactase persistence in individuals with the CT and TT genotypes and lactase non-persistence in individuals with the CC genotype. However, analysis of ...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2015.11.001

    authors: Dzialanski Z,Barany M,Engfeldt P,Magnuson A,Olsson LA,Nilsson TK

    更新日期:2016-02-01 00:00:00

  • Characterization and mRNA expression analysis of a novel ARG1 splicing mutation causing hyperargininemia.

    abstract:OBJECTIVES:Biallelic mutations in the ARG1 gene result in an uncommon autosomal recessive inborn defect of the urea cycle known as hyperargininemia (OMIM #207800). ARG1 splicing mutations are not reported often, and they are probably related to a more severe phenotype than missense mutations. In this article, we descri...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2015.07.015

    authors: Villegas-Ruiz V,Campos-Garcia FJ,Contreras-Capetillo S,Moreno-Graciano CM,Maldonado-Solis FA,Maldonado-Solis MA,Zenteno JC

    更新日期:2015-12-01 00:00:00

  • Critical review and meta-analysis on the combination of heart-type fatty acid binding protein (H-FABP) and troponin for early diagnosis of acute myocardial infarction.

    abstract::An early diagnosis is crucial for effective triage and management of patients with suspected acute myocardial infarction (AMI). Although troponin testing is the cornerstone of diagnosis, the sensitivity of this biomarker is still suboptimal at patient admission. The heart-type fatty acid binding protein (H-FABP) is an...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章,meta分析,评审

    doi:10.1016/j.clinbiochem.2012.10.016

    authors: Lippi G,Mattiuzzi C,Cervellin G

    更新日期:2013-01-01 00:00:00

  • CRISPR-based tools: Alternative methods for the diagnosis of COVID-19.

    abstract::The recently emerged severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) spread all over the world rapidly and caused a global pandemic. To prevent the virus from spreading to more individuals, it is of great importance to identify and isolate infected individuals through testing. Reverse transcription-quanti...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章,评审

    doi:10.1016/j.clinbiochem.2020.12.011

    authors: Palaz F,Kalkan AK,Tozluyurt A,Ozsoz M

    更新日期:2021-01-09 00:00:00

  • USA hCG reference service, 10-year report.

    abstract:INTRODUCTION:The USA hCG Reference Service has been dealing with cases of persistent low levels of hCG and gestational trophoblastic diseases for 10years. Here we present the complete experience. METHODS:Total hCG in serum and urine was measured using the Siemen's Immulite 1000 assay. Hyperglycosylated hCG, nicked hCG...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2010.05.006

    authors: Cole LA,Laidler LL,Muller CY

    更新日期:2010-08-01 00:00:00

  • Are vitamins A and D important in the development of food allergy and how are they best measured?

    abstract::Food allergy has a dramatic impact on a child's (and their family's) quality of life and places a major financial burden on the community. It has been hypothesized that the increase in food allergy may relate to the concordant rise in prevalence of vitamin D insufficiency. More recently a second hypothesis has implica...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章,评审

    doi:10.1016/j.clinbiochem.2014.01.033

    authors: Zakariaeeabkoo R,Allen KJ,Koplin JJ,Vuillermin P,Greaves RF

    更新日期:2014-06-01 00:00:00

  • A simple matrix of analytical performance to identify assays that risk patients using External Quality Assurance Program data.

    abstract:OBJECTIVES:We propose a simple way to reliably rank assays for improvement according to patient risk, based solely on EQA imprecision and biological variation data. Because the underlying technique aligns the imprecision class of an assay from EQA data, peer performance can be used to assess achievable imprecision and ...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2016.01.014

    authors: Mackay M,Hegedus G,Badrick T

    更新日期:2016-05-01 00:00:00

  • Biochemical characterization of chitotriosidase enzyme: comparison between normal individuals and patients with Gaucher and with Niemann-Pick diseases.

    abstract:OBJECTIVES:The aim of the present study was to establish the range of chitotriosidase (CT) activity in normal individuals, patients with Gaucher disease (GD) and Niemann-Pick disease (NPD), types A or B. The kinetics of CT in these three groups was also investigated. DESIGN AND METHODS:CT activity, as well as Km, Vmax...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2004.06.008

    authors: Wajner A,Michelin K,Burin MG,Pires RF,Pereira ML,Giugliani R,Coelho JC

    更新日期:2004-10-01 00:00:00

  • Influence of temperature and period of freezing on the generation of hemolysate and blood cell lysate.

    abstract:BACKGROUND:There is little information on temperature and period of freezing for generating hemolysate and blood cell lysate. MATERIALS AND METHODS:Primary tubes containing whole blood were frozen at -20°C and -80°C and then serially thawed to assess cell lysis and clinical chemistry tests in centrifuged plasma. RESU...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2011.07.015

    authors: Lippi G,Musa R,Aloe R,Mercadanti M,Pipitone S

    更新日期:2011-10-01 00:00:00

  • Evaluation of the Boehringer Mannheim ES 300 immunoassay analyzer and comparison with enzyme immunoassay, fluorescence polarization immunoassay, and radioimmunoassay methods.

    abstract::The ES 300 (Boehringer Mannheim Diagnostics, Indianapolis, IN) is a new automated immunoassay analyzer intended for the quantitative determination of a wide range of analytes. We compared its performance to enzyme immunoassay (EIA), fluorescence polarization immunoassay (FPIA), and radioimmunoassay (RIA) methods for c...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/0009-9120(92)80029-g

    authors: Camara PD,Velletri K,Krupski M,Rosner M,Griffiths WC

    更新日期:1992-08-01 00:00:00

  • Long-term stability of biochemical markers in pediatric serum specimens stored at -80 °C: a CALIPER Substudy.

    abstract:OBJECTIVES:Pediatric serum samples collected from healthy children in the CALIPER (Canadian Laboratory Initiative in Pediatric Reference Interval) project are stored at -80 °C for various periods of time. This study aimed to determine the stability of chemistry, protein, and hormone analytes under these conditions. DE...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2012.03.029

    authors: Brinc D,Chan MK,Venner AA,Pasic MD,Colantonio D,Kyriakopolou L,Adeli K

    更新日期:2012-07-01 00:00:00

  • Glucose-6-phosphate dehydrogenase enzyme stability in filter paper dried blood spots.

    abstract:OBJECTIVE:Prior to initial distribution of Glucose-6-phosphate dehydrogenase (G6PD) proficiency testing (PT) materials, we evaluated G6PD enzyme stability in dried blood spots (DBS) under various temperature and humidity environments to develop storage and usage guidelines for our new materials. DESIGN & METHODS:We pr...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2017.05.003

    authors: Flores SR,Hall EM,De Jesús VR

    更新日期:2017-10-01 00:00:00

  • Identification of a complex between fibronectin and aggrecan G3 domain in synovial fluid of patients with painful meniscal pathology.

    abstract:OBJECTIVES:We previously described a panel of four cytokines biomarkers in knee synovial fluid for acute knee pain associated with meniscal pathology. The cytokine biomarkers included interferon gamma (IFN-gamma), interleukin 6 (IL-6), monocyte chemotactic protein 1 (MCP-1), and macrophage inflammatory protein-1 beta (...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2010.04.069

    authors: Scuderi GJ,Woolf N,Dent K,Golish SR,Cuellar JM,Cuellar VG,Yeomans DC,Carragee EJ,Angst MS,Bowser R,Hanna LS

    更新日期:2010-07-01 00:00:00

  • Cytokine profile of Armenian patients with Familial Mediterranean fever.

    abstract:OBJECTIVES:Despite the well-defined genetics of FMF, limited information is available regarding the regulation of inflammation by cytokines. DESIGN AND METHODS:The levels of systemic cytokines and other markers of inflammation in FMF patients and control were measured by ELISA and Cytometric Bead Array (CBA). RESULTS...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2008.03.017

    authors: Manukyan GP,Ghazaryan KA,Ktsoyan ZhA,Tatyan MV,Khachatryan ZA,Hakobyan GS,Mkrtchyan VA,Kelly D,Coutts A,Aminov RI

    更新日期:2008-07-01 00:00:00

  • Continuous reference intervals for 38 biochemical markers in healthy children and adolescents: Comparisons to traditionally partitioned reference intervals.

    abstract:BACKGROUND:Reference intervals have traditionally been partitioned by age based on statistical significance and physiological relevance. However, analyte concentration does not change abruptly with age, but rather dynamically. In this study, we establish biochemical marker continuous reference intervals for a Canadian ...

    journal_title:Clinical biochemistry

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.clinbiochem.2019.08.010

    authors: Asgari S,Higgins V,McCudden C,Adeli K

    更新日期:2019-11-01 00:00:00

  • Reference interval estimation: Methodological comparison using extensive simulations and empirical data.

    abstract:OBJECTIVE:To statistically compare and evaluate commonly used methods of estimating reference intervals and to determine which method is best based on characteristics of the distribution of various data sets. DESIGN AND METHODS:Three approaches for estimating reference intervals, i.e. parametric, non-parametric, and r...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2017.07.005

    authors: Daly CH,Higgins V,Adeli K,Grey VL,Hamid JS

    更新日期:2017-12-01 00:00:00

  • Biochemical markers of bone metabolism: an overview.

    abstract:OBJECTIVES:An overview of biochemical markers of bone metabolism is presented along with indications for their clinical utilization. DESIGN AND METHODS:The structure, cyclical metabolism, and hormone regulation of bone is reflected by markers of resorption, formation and/or turnover. Markers of resorption representing...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章,评审

    doi:10.1016/s0009-9120(97)00113-6

    authors: Christenson RH

    更新日期:1997-12-01 00:00:00