Abstract:
BACKGROUND:The accuracy of source reconstruction depends on the spatial configuration of the neural sources underlying encephalographic signals, the temporal distance of the source activity, the level and structure of noise in the recordings, and - of course - on the employed inverse method. This plenitude of factors renders a definition of 'spatial resolution' of the electro-encephalogram (EEG) a challenge. NEW METHOD:A proper definition of spatial resolution requires a ground truth. We used data from numerical simulations of two dipoles changed with waveforms resembling somatosensory evoked potentials peaking at 20, 30, 50, 100 ms. We varied inter-dipole distances and added noise to the simulated scalp recordings with distinct signal-to-noise ratios (SNRs). Prior to inverse modeling we pre-whitened the simulated data and the leadfield. We tested a two-dipole fit, sc-MUSIC, and sc-eLORETA and assessed their accuracy via the distance between the simulated and estimated sources. RESULTS:To quantify the spatial resolution of EEG, we introduced the notion of separability, i.e. the separation of two dipolar sources with a certain inter-dipole distance. Our results indicate separability of two sources in the presence of realistic noise with SNR up to 3 if they are 11 mm or further apart. COMPARISON WITH EXISTING METHODS:In the presence of realistic noise, spatial pre-whitening appears mandatory preprocessing step irrespective of the inverse method employed. CONCLUSIONS:Separability is a legitimate measure to quantify EEG's spatial resolution. An optimal resolution in source reconstruction requires spatial pre-whitening as a crucial pre-processing step.
journal_name
J Neurosci Methodsjournal_title
Journal of neuroscience methodsauthors
Kalogianni K,de Munck JC,Nolte G,Vardy AN,van der Helm FCT,Daffertshofer Adoi
10.1016/j.jneumeth.2018.02.016subject
Has Abstractpub_date
2018-05-01 00:00:00pages
9-17eissn
0165-0270issn
1872-678Xpii
S0165-0270(18)30052-9journal_volume
301pub_type
杂志文章abstract:BACKGROUND:Electroencephalogram (EEG) signals are often corrupted with unintended artifacts which need to be removed for extracting meaningful clinical information from them. Typically a priori knowledge of the nature of the artifacts is needed for such purpose. Artifact contamination of EEG is even more prominent for ...
journal_title:Journal of neuroscience methods
pub_type: 杂志文章
doi:10.1016/j.jneumeth.2016.04.006
更新日期:2016-07-15 00:00:00
abstract::A simple method is described for achieving a salt bridge within a patch pipette. The tip of the pipette is filled with a Cl(-)-free solution that bathes the membrane patch. Above this is a Cl(-)-containing solution that surrounds the recording Ag/AgCl wire electrode. Addition of 0.07% (w/v) agarose to the solution in ...
journal_title:Journal of neuroscience methods
pub_type: 杂志文章
doi:10.1016/0165-0270(93)90136-f
更新日期:1993-01-01 00:00:00
abstract::Electrical potentials recorded extracellularly from the sinus gland of the isopod, Oniscus asellus, were stored on video tape with the aid of a digital-audio (DA) processor and a video cassette recorder (VCR). The DA processor transforms the analog signal to digital pulses of equal amplitude and converts these pulses ...
journal_title:Journal of neuroscience methods
pub_type: 杂志文章
doi:10.1016/0165-0270(85)90058-5
更新日期:1985-10-01 00:00:00
abstract::Aberrant central nervous system zinc homeostasis has been reported in Alzheimer's disease (AD). However, there are conflicting reports describing zinc concentration either increased or decreased in the brain of AD patients. Such discrepancies may be due to differences in the brain area examined, zinc detection method,...
journal_title:Journal of neuroscience methods
pub_type: 杂志文章
doi:10.1016/j.jneumeth.2011.09.008
更新日期:2012-01-15 00:00:00
abstract:BACKGROUND:We analyze the dynamics of rodent EEG amplitude in an experiment accompanied by video recordings. Brain activity of animals is commonly acquired together with a video of behavior, but recordings are rarely combined in analysis. The data acquired is most commonly analyzed separately. To our knowledge, no stud...
journal_title:Journal of neuroscience methods
pub_type: 杂志文章
doi:10.1016/j.jneumeth.2018.01.002
更新日期:2018-03-15 00:00:00
abstract:BACKGROUND:Preprocessed Event-related potential (ERP) data are usually organized in multi-way tensor, in which tensor decomposition serves as a powerful tool for data processing. Due to the limitation of computation burden for multi-way data and the low algorithm performance of stability and efficiency, multi-way ERP d...
journal_title:Journal of neuroscience methods
pub_type: 杂志文章
doi:10.1016/j.jneumeth.2018.07.020
更新日期:2018-10-01 00:00:00
abstract::Three-dimensional (3D) reaggregate tissue culture provides a means of quantitatively assessing neuronal cell survival under a variety of experimental conditions. A method is presented for estimation of, and comparison between, the total numbers of cells of a given neurochemical type within individual experimental flas...
journal_title:Journal of neuroscience methods
pub_type: 杂志文章
doi:10.1016/0165-0270(94)00110-3
更新日期:1995-01-01 00:00:00
abstract::We have recently reported that in the learned helplessness model of depression, the less hippocampal spine synapses rats have, the more helpless they become. It remains unclear, however, whether the observed synaptic changes are associated with the loss of CA1 pyramidal cells. Cell bodies in the CA1 pyramidal layer ar...
journal_title:Journal of neuroscience methods
pub_type: 杂志文章
doi:10.1016/j.jneumeth.2011.12.017
更新日期:2012-03-30 00:00:00
abstract:BACKGROUND:Virtual reality-based neuropsychological assessments proffer the potential to address the limited ecological validity of pen-and-paper measures of memory. NEW METHOD:To investigate the construct validity of a newly developed virtual reality-based multiple errands task, the Virtual Environment Grocery Store ...
journal_title:Journal of neuroscience methods
pub_type: 杂志文章
doi:10.1016/j.jneumeth.2017.07.027
更新日期:2017-11-01 00:00:00
abstract::A current source for neural stimulation is presented which converts arbitrary voltage signals to current-controlled signals while regulating the offset-voltage across the stimulation electrodes in order to keep the electrodes in an electrochemical state that allows for injecting a maximum charge. The offset-voltage ca...
journal_title:Journal of neuroscience methods
pub_type: 杂志文章
doi:10.1016/j.jneumeth.2008.03.016
更新日期:2008-06-30 00:00:00
abstract::Brain dialysis has become an important tool for investigating changes in the extracellular levels of neurotransmitters. This paper reviews the experimental variables and criteria that should be considered when interpreting data obtained with the brain dialysis method. Brain dialysis can provide important direct inform...
journal_title:Journal of neuroscience methods
pub_type: 杂志文章,评审
doi:10.1016/0165-0270(90)90039-i
更新日期:1990-09-01 00:00:00
abstract::Operant animal behavioral tests require the interaction of the subject with sensors and actuators distributed in the experimental environment of the arena. In order to provide user independent reliable results and versatile control of these devices it is vital to use an automated control system. Commercial systems for...
journal_title:Journal of neuroscience methods
pub_type: 杂志文章
doi:10.1016/j.jneumeth.2007.06.020
更新日期:2007-10-15 00:00:00
abstract::2,3,5-Triphenyltetrazolium chloride (TTC), a marker of mitochondrial enzyme activity, is widely used to assess the effects of cerebral ischaemia in vivo. In the present study, we characterised its utility as a simple rapid macrohistological measure of ischaemic damage in brain slices. Coronal rat corticostriatal slice...
journal_title:Journal of neuroscience methods
pub_type: 杂志文章
doi:10.1016/s0165-0270(00)00277-6
更新日期:2000-10-15 00:00:00
abstract::A modification of the formalin test appropriate for testing of mice is described. Formalin 1 or 5% was injected into the dorsal surface of a hindpaw, and the time the animal spent licking the paw was recorded. On the basis of the response pattern, two distinct periods of intensive licking activity were identified; an ...
journal_title:Journal of neuroscience methods
pub_type: 杂志文章
doi:10.1016/0165-0270(85)90116-5
更新日期:1985-06-01 00:00:00
abstract::We present a numerical method which provides the ability to analyze digitized microscope images of retinal explants and quantify neurite outgrowth. Few parameters are required as input and limited user interaction is necessary to process an entire experiment of images. This eliminates fatigue related errors and user-r...
journal_title:Journal of neuroscience methods
pub_type: 杂志文章
doi:10.1016/s0165-0270(03)00017-7
更新日期:2003-04-15 00:00:00
abstract:BACKGROUND:Although the relationship between neuronavigated transcranial magnetic stimulation (nTMS) and functional magnetic resonance imaging (fMRI) has been widely studied in motor mapping, it is unknown how the motor response type or the choice of motor task affect this relationship. NEW METHOD:Centers of gravity (...
journal_title:Journal of neuroscience methods
pub_type: 杂志文章
doi:10.1016/j.jneumeth.2016.09.002
更新日期:2016-11-01 00:00:00
abstract::An important factor in reducing variability in mouse test outcomes has been to develop assays that can be used for continuous automated home cage assessment. Our experience has shown that this has been most evidenced in long-term assessment of wheel-running activity in mice. Historically, wheel-running in mice and oth...
journal_title:Journal of neuroscience methods
pub_type: 杂志文章
doi:10.1016/j.jneumeth.2017.04.014
更新日期:2018-04-15 00:00:00
abstract::Two-photon laser scan microscopy carries many advantages for work on brain slices and bulk tissue. However, it has very low signal levels compared to conventional fluorescence microscopy. This is disadvantageous in fast imaging applications when photon shot noise is limiting. Working on brain slices with excitation po...
journal_title:Journal of neuroscience methods
pub_type: 杂志文章
doi:10.1016/s0165-0270(99)00103-x
更新日期:1999-10-15 00:00:00
abstract:BACKGROUND:Given the movement of molecules within tissue that occurs naturally by endogenous electric fields, we examined the possibility of using a low-voltage DC field to move charged substances in rodent peripheral nerve in vitro. NEW METHOD:Labeled sugar- and protein-based markers were applied to a rodent peroneal...
journal_title:Journal of neuroscience methods
pub_type: 杂志文章
doi:10.1016/j.jneumeth.2014.01.018
更新日期:2014-03-30 00:00:00
abstract:BACKGROUND:Neural spikes from multiple neurons recorded in a multi-unit signal are usually separated by clustering. Drifts in the position of the recording electrode relative to the neurons over time cause gradual changes in the position and shapes of the clusters, challenging the clustering task. By dividing the data ...
journal_title:Journal of neuroscience methods
pub_type: 杂志文章
doi:10.1016/j.jneumeth.2013.12.005
更新日期:2014-02-15 00:00:00
abstract::A new technique, "serial block face scanning electron microscopy" (SBFSEM), allows for automatic sectioning and imaging of biological tissue with a scanning electron microscope. Image stacks generated with this technology have a resolution sufficient to distinguish different cellular compartments, including synaptic s...
journal_title:Journal of neuroscience methods
pub_type: 杂志文章
doi:10.1016/j.jneumeth.2007.07.021
更新日期:2008-01-30 00:00:00
abstract::Detecting brain structural changes from magnetic resonance (MR) images can facilitate early diagnosis and treatment of neurological and psychiatric diseases. Many existing methods require an accurate deformation registration, which is difficult to achieve and therefore prevents them from obtaining high accuracy. We de...
journal_title:Journal of neuroscience methods
pub_type: 杂志文章
doi:10.1016/j.jneumeth.2013.09.001
更新日期:2014-01-15 00:00:00
abstract:BACKGROUND:Sympathetic nerve wiring in the mammalian heart has remained largely unexplored. Resolving the wiring diagram of the cardiac sympathetic network would help establish the structural underpinnings of neurocardiac coupling. NEW METHOD:We used two-photon excitation fluorescence microscopy, combined with a compu...
journal_title:Journal of neuroscience methods
pub_type: 杂志文章
doi:10.1016/j.jneumeth.2013.09.005
更新日期:2014-01-15 00:00:00
abstract::An inexpensive system for quantitative electroencephalogram (EEG) analysis over long time periods is described. This system continuously analyses EEG for intensity versus frequency content, and saves averaged 'data reduced' intensity spectra to disk at regular intervals. The method had adequate frequency resolution fo...
journal_title:Journal of neuroscience methods
pub_type: 杂志文章
doi:10.1016/0165-0270(90)90066-o
更新日期:1990-04-01 00:00:00
abstract::Classification of spoken word-evoked potentials is useful for both neuroscientific and clinical applications including brain-computer interfaces (BCIs). By evaluating whether adopting a biology-based structure improves a classifier's accuracy, we can investigate the importance of such structure in human brain circuitr...
journal_title:Journal of neuroscience methods
pub_type: 杂志文章
doi:10.1016/j.jneumeth.2018.10.034
更新日期:2019-01-01 00:00:00
abstract::A technique has been developed which allows extracellular recording from single neurons in the spinal cord of physiologically intact, awake, drug-free, restrained cats. The technique involves the surgical placement, under general anesthesia, of a stainless steel recording chamber which has a rectangular opening in its...
journal_title:Journal of neuroscience methods
pub_type: 杂志文章
doi:10.1016/0165-0270(85)90012-3
更新日期:1985-02-01 00:00:00
abstract::The quantification of synapses in neuronal cultures is essential in studies of the molecular mechanisms underlying synaptogenesis and synaptic plasticity. Conventional counting of synapses based on morphological or immunocytochemical criteria is extremely work-intensive. We developed a fully automated method which qua...
journal_title:Journal of neuroscience methods
pub_type: 杂志文章
doi:10.1016/j.jneumeth.2011.11.010
更新日期:2012-02-15 00:00:00
abstract:BACKGROUND:Military personnel and civilians living in areas of armed conflict have increased risk of exposure to blast overpressures that can cause significant hearing loss and/or brain injury. The equipment used to simulate comparable blast overpressures in animal models within laboratory settings is typically very la...
journal_title:Journal of neuroscience methods
pub_type: 杂志文章
doi:10.1016/j.jneumeth.2015.01.009
更新日期:2015-03-15 00:00:00
abstract::We characterised the dynamics in the oscillatory potentials (OPs) of the rat electroretinogram (ERG) using a continuous complex Morlet wavelet transform. Dark-adapted (>12h) full field ERG responses were recorded from five anaesthetized (ketamine:xylazine, 60:5mg/kg) adult Long-Evans rats (10-12weeks). Five responses ...
journal_title:Journal of neuroscience methods
pub_type: 杂志文章
doi:10.1016/j.jneumeth.2007.12.007
更新日期:2008-03-30 00:00:00
abstract:BACKGROUND:Electroencephalography (EEG) experiments often require several computers to ensure accurate stimulus presentation and data collection. However, this requirement can make it more difficult to perform such experiments in mobile settings within, or outside, the laboratory. NEW METHOD:Computer miniaturisation a...
journal_title:Journal of neuroscience methods
pub_type: 杂志文章
doi:10.1016/j.jneumeth.2018.07.013
更新日期:2018-10-01 00:00:00