Can an Offsite Expert Remotely Evaluate the Visual Estimation of Ejection Fraction via a Social Network Video Call?

Abstract:

:We aimed to investigate whether an offsite expert could effectively evaluate visually estimated ejection fraction (EF) while watching and guiding the echocardiographic procedure of an onsite novice practitioner using a social network video call. Sixty patients presenting to the intensive care unit and requiring echocardiography between October and November 2016 were included. Sixty novice sonographers without any previous experience of echocardiography participated. Prior to the procedure, the onsite cardiologist completed the echocardiography and determined the EF using the modified Simpson's method (reference value). Then, the novice practitioner performed the echocardiography again with the offsite expert's guidance via a social network video call. The EF was visually estimated by the offsite expert while watching the ultrasound video on the smartphone display. Spearman's rank correlation and Bland-Altman plot analysis were conducted to assess the agreement between the two methods. There was excellent agreement between the two methods, with a correlation coefficient of 0.94 (p < 0.001). The Bland-Altman plot showed that the average bias was -3.05, and the limit of agreement (-10.3 to 4.2) was narrow. The offsite expert was able to perform an accurate visual estimation of ejection fraction remotely via a social network video call by mentoring the onsite novice sonographer. ClinicalTrials.gov Identifier: NCT02960685.

journal_name

J Digit Imaging

authors

Kim C,Hur J,Kang BS,Choi HJ,Shin JH,Kim TH,Chung JH

doi

10.1007/s10278-017-9974-5

subject

Has Abstract

pub_date

2017-12-01 00:00:00

pages

718-725

issue

6

eissn

0897-1889

issn

1618-727X

pii

10.1007/s10278-017-9974-5

journal_volume

30

pub_type

杂志文章
  • An ROC study of chest radiographs: 2K Versus 4K high-resolution soft-copy images.

    abstract::Computed radiography of chest with a 4K image array was recently introduced. We performed a multiobserver study to compare the diagnostic accuracy of 2K (standard) and 4K (high quality) chest radiographs displayed on a 5-mega-pixel monitor (2K monitor). One hundred cases of posteroanterior chest radiographs (a total o...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-1048-z

    authors: Kim SY,Hwang YJ,Han YH,Seo JW,Lee JY,Kim YH,Cha SJ,Hur G,Lee SS

    更新日期:2007-12-01 00:00:00

  • Solution for nonuniformities and spatial noise in medical LCD displays by using pixel-based correction.

    abstract::Liquid crystal displays (LCD) are rapidly replacing cathode ray tube displays (CRT) for medical imaging. LCD technology has improved significantly in the last few years and has important advantages over CRT. However, there are still some aspects of LCD that raise questions as to the usefulness of liquid crystal displa...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-005-2939-0

    authors: Kimpe T,Xthona A,Matthijs P,De Paepe L

    更新日期:2005-09-01 00:00:00

  • A filmless radiology teaching conference system for pertinent displaying and image searching.

    abstract::To solve the problems of image displays in filmless radiology conferences for the purpose of teaching, we made an experimental design of a conference system with dual 50-in. plasma monitors for displaying larger images and a shared folder containing shortcuts to images for quick display during conferences on the deskt...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-007-9095-7

    authors: Abe K,Narata M,Tanaka I,Takahashi M,Igarashi A,Sasaki T,Matsuyama K,Tohi N,Kosuda S

    更新日期:2009-12-01 00:00:00

  • Clinical impact of picture archiving and communication systems: evaluation of a prototype system.

    abstract::Opinion surveys were gathered before and 6 months after installation of a prototype picture archiving and communication system (PACS) (PACS/1, Siemens Medical Systems, Iselin, NJ). Median turnaround times and the percent of delayed or missing reports were calculated for 1,026 baseline and 8,438 follow-up studies at 6 ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167836

    authors: Worrell JA,Federspiel CF,Creasy JL,Pickens DR 3rd,Higginbotham K,Patton JA,Partain CL

    更新日期:1992-05-01 00:00:00

  • Diagnosis of Autism Spectrum Disorders in Young Children Based on Resting-State Functional Magnetic Resonance Imaging Data Using Convolutional Neural Networks.

    abstract::Statistics show that the risk of autism spectrum disorder (ASD) is increasing in the world. Early diagnosis is most important factor in treatment of ASD. Thus far, the childhood diagnosis of ASD has been done based on clinical interviews and behavioral observations. There is a significant need to reduce the use of tra...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00196-1

    authors: Aghdam MA,Sharifi A,Pedram MM

    更新日期:2019-12-01 00:00:00

  • Use of a thin-section archive and enterprise 3D software for long-term storage of thin-slice CT data sets.

    abstract::Rapid advances are changing the technology and applications of multidetector computed tomography (CT) scanners. The major increase in data associated with this new technology, however, breaks most commercial picture archiving and communication system (PACS) architectures by preventing them from delivering data in real...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-0925-9

    authors: Meenan C,Daly B,Toland C,Nagy P

    更新日期:2006-01-01 00:00:00

  • A Pilot Study on the Development of Remote Quality Control of Digital Mammography Systems in the NHS Breast Screening Programme.

    abstract::In the UK, physicists and radiographers perform routine quality control (QC) of digital mammography equipment at daily, weekly and monthly intervals. The tests performed and tolerances are specified by standard protocols. The manual nature of many of the tests introduces variability due to the positioning of regions o...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-014-9759-z

    authors: Looney P,Halling-Brown MD,Oduko JM,Young KC

    更新日期:2015-10-01 00:00:00

  • Distributing digital imaging and communications in medicine data and optimizing access over satellite networks.

    abstract::To improve radiology access to full uncompressed Digital Imaging and Communications in Medicine (DICOM) data sets, we evaluated satellite access to a DICOM server. Radiologists' home computers were connected by satellite to a Medweb DICOM server (Medweb, San Francisco, CA). A 10.2-kb data set containing a 19-image hea...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168799

    authors: Ernst RD,Kawashima A,Shepherd W,Tamm EP,Sandler CM

    更新日期:1999-05-01 00:00:00

  • Computed radiography printing problems: a quantitative, observer-independent solution.

    abstract::Even though facilities using computed radiography (CR) operate in an electronic environment, the production of hard-copy films is still necessary during the transition period, as well as for particular needs following complete implementation. We have implemented a quantitative technique to match the response of printe...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167622

    authors: Hildestad CA,Morin RL

    更新日期:2000-05-01 00:00:00

  • Analysis of the X-ray work flow in two diagnostic imaging departments with and without a RIS/PACS system.

    abstract::A traditional radiological workflow is compared with one based on radiology information system/picture archiving and communication system (RIS/PACS). X-ray workflow process was considered in both radiology departments. First, the study identified the main phases of the research work as follows: Process Analysis, Data ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-0858-3

    authors: Mariani C,Tronchi A,Oncini L,Pirani O,Murri R

    更新日期:2006-01-01 00:00:00

  • Detection of breast cancer with a computer-aided detection applied to full-field digital mammography.

    abstract::A study was conducted to evaluate the sensitivity of computer-aided detection (CAD) with full-field digital mammography in detection of breast cancer, based on mammographic appearance and histopathology. Retrospectively, CAD sensitivity was assessed in total group of 152 cases for subgroups based on breast density, ma...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9564-5

    authors: Murakami R,Kumita S,Tani H,Yoshida T,Sugizaki K,Kuwako T,Kiriyama T,Hakozaki K,Okazaki E,Yanagihara K,Iida S,Haga S,Tsuchiya S

    更新日期:2013-08-01 00:00:00

  • Computer-Aided Histopathological Image Analysis Techniques for Automated Nuclear Atypia Scoring of Breast Cancer: a Review.

    abstract::Breast cancer is the most common type of malignancy diagnosed in women. Through early detection and diagnosis, there is a great chance of recovery and thereby reduce the mortality rate. Many preliminary tests like non-invasive radiological diagnosis using ultrasound, mammography, and MRI are widely used for the diagno...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-019-00295-z

    authors: Das A,Nair MS,Peter SD

    更新日期:2020-10-01 00:00:00

  • A study of radiologists viewing multiple computed tomography examinations using an eyetracking device.

    abstract::Understanding the scan patterns radiologists use to view medical images is critical to the design of image viewing devices. In this study, an eyetracker, a device for recording eye and head movement, was used to determine the scan patterns during the interpretation of single and multiple computed tomographic (CT) exam...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168120

    authors: Beard DV,Johnston RE,Toki O,Wilcox C

    更新日期:1990-11-01 00:00:00

  • Combining fast response and low cost in an intensive care unit viewing station.

    abstract::This paper describes a prototype viewing station for the Intensive Care Unit (ICU) that combines a low cost with a fast response for the primary viewing tasks. A single monitor is used together with the possibility to switch to another image on the same screen instantaneously. To reduce the time for image retrieval an...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168429

    authors: Bellon E,Houtput W,Bijnens B,Suetens P,Marchal G,Lauwers P

    更新日期:1994-05-01 00:00:00

  • Towards a repository for standardized medical image and signal case data annotated with ground truth.

    abstract::Validation of medical signal and image processing systems requires quality-assured, representative and generally acknowledged databases accompanied by appropriate reference (ground truth) and clinical metadata, which are composed laboriously for each project and are not shared with the scientific community. In our vis...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9428-4

    authors: Deserno TM,Welter P,Horsch A

    更新日期:2012-04-01 00:00:00

  • Minimizing Barriers in Learning for On-Call Radiology Residents-End-to-End Web-Based Resident Feedback System.

    abstract::Feedback is an essential part of medical training, where trainees are provided with information regarding their performance and further directions for improvement. In diagnostic radiology, feedback entails a detailed review of the differences between the residents' preliminary interpretation and the attendings' final ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-017-0015-1

    authors: Choi HH,Clark J,Jay AK,Filice RW

    更新日期:2018-02-01 00:00:00

  • Comparison of algorithms to enhance spicules of spiculated masses on mammography.

    abstract::We have developed an algorithm for enhancement of spicules of spiculated masses, which uses the discrete radon transform. Previously, we employed a commonly used method to compute the discrete radon transform, which we refer to as the DRT. Recently, a new, more exact method to compute the discrete radon transform was ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-007-9015-x

    authors: Sampat MP,Whitman GJ,Bovik AC,Markey MK

    更新日期:2008-03-01 00:00:00

  • A Web simulation of medical image reconstruction and processing as an educational tool.

    abstract::Web educational resources integrating interactive simulation tools provide students with an in-depth understanding of the medical imaging process. The aim of this work was the development of a purely Web-based, open access, interactive application, as an ancillary learning tool in graduate and postgraduate medical ima...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-014-9689-9

    authors: Papamichail D,Pantelis E,Papagiannis P,Karaiskos P,Georgiou E

    更新日期:2015-02-01 00:00:00

  • Development of a research dedicated archival system (TARAS) in a university hospital.

    abstract::Recent healthcare policies have influenced the manner in which patient data is handled in research projects, and the regulations concerning protected health information have become significantly tighter. Thus, new procedures are needed to facilitate research while protecting the confidentiality of patient data and ens...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-010-9350-1

    authors: Rajala T,Savio S,Penttinen J,Dastidar P,Kähönen M,Eskola H,Miettunen R,Turjanmaa V,Järvenpää R

    更新日期:2011-10-01 00:00:00

  • Medical applications of digital image morphing.

    abstract::The authors present a unique medical technical application for illustrating the success and/or failure of the physiological healing process as a dynamically morphed video. Two examples used in this report include the healing of a severely fractured humerus from an explosion in Iraq and the other of dramatic tissue des...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-1050-5

    authors: Penska K,Folio L,Bunger R

    更新日期:2007-09-01 00:00:00

  • Classification of hypervascular liver lesions based on hepatic artery and portal vein blood supply coefficients calculated from triphasic CT scans.

    abstract::Perfusion CT of the liver typically involves scanning the liver at least 20 times, resulting in a large radiation dose. We developed and validated a simplified model of tumor blood supply that can be applied to standard triphasic scans and evaluated whether this can be used to distinguish benign and malignant liver le...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-014-9725-9

    authors: Boas FE,Kamaya A,Do B,Desser TS,Beaulieu CF,Vasanawala SS,Hwang GL,Sze DY

    更新日期:2015-04-01 00:00:00

  • Combining multi-scale feature fusion with multi-attribute grading, a CNN model for benign and malignant classification of pulmonary nodules.

    abstract::Lung cancer has the highest mortality rate of all cancers, and early detection can improve survival rates. In the recent years, low-dose CT has been widely used to detect lung cancer. However, the diagnosis is limited by the subjective experience of doctors. Therefore, the main purpose of this study is to use convolut...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-020-00333-1

    authors: Zhao J,Zhang C,Li D,Niu J

    更新日期:2020-08-01 00:00:00

  • Automated hands-free image manipulation and viewing: a useful macro feature that assists radiologists in the viewing of chest and extremity digital radiographs.

    abstract::The authors present an adaptation of the macro recording feature on the Siemens Magic View 1000 workstation, which, with the click of one button, launches a macro that performs 3 clinically useful image manipulations. Using a Magic View 1004 Siemens unix workstation, the following Macro sequence was programmed: (1) se...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-002-5078-x

    authors: Koenker RM,Grover SA

    更新日期:2002-01-01 00:00:00

  • Automatic Normalization of Anatomical Phrases in Radiology Reports Using Unsupervised Learning.

    abstract::In today's radiology workflow, free-text reporting is established as the most common medium to capture, store, and communicate clinical information. Radiologists routinely refer to prior radiology reports of a patient to recall critical information for new diagnosis, which is quite tedious, time consuming, and prone t...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0116-5

    authors: Tahmasebi AM,Zhu H,Mankovich G,Prinsen P,Klassen P,Pilato S,van Ommering R,Patel P,Gunn ML,Chang P

    更新日期:2019-02-01 00:00:00

  • Applying Modern Virtual and Augmented Reality Technologies to Medical Images and Models.

    abstract::Recent technological innovations have created new opportunities for the increased adoption of virtual reality (VR) and augmented reality (AR) applications in medicine. While medical applications of VR have historically seen greater adoption from patient-as-user applications, the new era of VR/AR technology has created...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-018-0122-7

    authors: Sutherland J,Belec J,Sheikh A,Chepelev L,Althobaity W,Chow BJW,Mitsouras D,Christensen A,Rybicki FJ,La Russa DJ

    更新日期:2019-02-01 00:00:00

  • Computed radiography in pediatrics.

    abstract::Computed radiography (CR) has various advantages such as dynamic range. Diagnostic accuracy with CR using reduced radiation dose is considered comparable with that of conventional film-screen radiography in diagnosing apparent chest abnormalities. In addition to reducing the radiation dose, delineation of the various ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168076

    authors: Aoki K

    更新日期:1995-02-01 00:00:00

  • Fibrous Dysplasia Characterization Using Lacunarity Analysis.

    abstract::Fibrous dysplasia (FD) is a developmental anomaly in which the normal medullary space of the affected bone is replaced by fibro-osseous tissue. This condition is typically encountered in adolescents and young adults. It affects the maxillofacial region and it can often cause severe deformity and asymmetry. Therefore, ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-015-9815-3

    authors: Cordeiro MS,Backes AR,Júnior AF,Gonçalves EH,de Oliveira JX

    更新日期:2016-02-01 00:00:00

  • Displaying radiologic images on personal computers: practical applications and uses.

    abstract::This is the fifth and final article in our series for radiologists and imaging scientists on displaying, manipulating, and analyzing radiologic images on personal computers (PCs). There are many methods of transferring radiologic images into a PC, including transfer over a network, transfer from an imaging modality st...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168502

    authors: Gillespy T 3rd,Richardson ML,Rowberg AH

    更新日期:1994-08-01 00:00:00

  • Stereotactic neurosurgery planning on a personal-computer-based work station.

    abstract::Stereotactic surgery requires knowledge of cerebral structures derived from more than one image source. We have developed a PC-AT-based workstation that accepts patient images, made with the stereotactic frame in place, from CT, MRI, and DSA modalities. Reference markers on the frame are identified in the images to es...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168023

    authors: Peters TM,Clark JA,Pike GB,Henri C,Collins L,Leksell D,Jeppsson O

    更新日期:1989-05-01 00:00:00

  • Online Radiology Reporting with Peer Review as a Learning and Feedback Tool in Radiology; Implementation, Validity, and Student Impressions.

    abstract::Communicating radiological reports to peers has pedagogical value. Students may be uneasy with the process due to a lack of communication and peer review skills or to their failure to see value in the process. We describe a communication exercise with peer review in an undergraduate veterinary radiology course. The co...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-016-9905-x

    authors: McEvoy FJ,Shen NW,Nielsen DH,Buelund LE,Holm P

    更新日期:2017-02-01 00:00:00