Diagnosis of Autism Spectrum Disorders in Young Children Based on Resting-State Functional Magnetic Resonance Imaging Data Using Convolutional Neural Networks.

Abstract:

:Statistics show that the risk of autism spectrum disorder (ASD) is increasing in the world. Early diagnosis is most important factor in treatment of ASD. Thus far, the childhood diagnosis of ASD has been done based on clinical interviews and behavioral observations. There is a significant need to reduce the use of traditional diagnostic techniques and to diagnose this disorder in the right time and before the manifestation of behavioral symptoms. The purpose of this study is to present the intelligent model to diagnose ASD in young children based on resting-state functional magnetic resonance imaging (rs-fMRI) data using convolutional neural networks (CNNs). CNNs, which are by far one of the most powerful deep learning algorithms, are mainly trained using datasets with large numbers of samples. However, obtaining comprehensive datasets such as ImageNet and achieving acceptable results in medical imaging domain have become challenges. In order to overcome these two challenges, the two methods of "combining classifiers," both dynamic (mixture of experts) and static (simple ‌Bayes) approaches, and "transfer learning" were used in this analysis. In addition, since diagnosis of ASD will be much more effective at an early age, samples ranging in age from 5 to 10 years from global Autism Brain Imaging Data Exchange I and II (ABIDE I and ABIDE II) datasets were used in this research. The accuracy, sensitivity, and specificity of presented model outperform the results of previous studies conducted on ABIDE I dataset (the best results obtained from Adamax optimization technique: accuracy = 0.7273, sensitivity = 0.712, specificity = 0.7348). Furthermore, acceptable classification results were obtained from ABIDE II dataset (the best results obtained from Adamax optimization technique: accuracy = 0.7, sensitivity = 0.582, specificity = 0.804) and the combination of ABIDE I and ABIDE II datasets (the best results obtained from Adam optimization technique: accuracy = 0.7045, sensitivity = 0.679, specificity = 0.7421). We can conclude that the proposed architecture can be considered as an efficient tool for diagnosis of ASD in young children. From another perspective, this proposed method can be applied to analyzing rs-fMRI data related to brain dysfunctions.

journal_name

J Digit Imaging

authors

Aghdam MA,Sharifi A,Pedram MM

doi

10.1007/s10278-019-00196-1

subject

Has Abstract

pub_date

2019-12-01 00:00:00

pages

899-918

issue

6

eissn

0897-1889

issn

1618-727X

pii

10.1007/s10278-019-00196-1

journal_volume

32

pub_type

杂志文章
  • Stereoscopic interpretation of low-dose breast tomosynthesis projection images.

    abstract::The purpose of this study was to evaluate stereoscopic perception of low-dose breast tomosynthesis projection images. In this Institutional Review Board exempt study, craniocaudal breast tomosynthesis cases (N = 47), consisting of 23 biopsy-proven malignant mass cases and 24 normal cases, were retrospectively reviewed...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9648-x

    authors: Muralidhar GS,Markey MK,Bovik AC,Haygood TM,Stephens TW,Geiser WR,Garg N,Adrada BE,Dogan BE,Carkaci S,Khisty R,Whitman GJ

    更新日期:2014-04-01 00:00:00

  • Automated hands-free image manipulation and viewing: a useful macro feature that assists radiologists in the viewing of chest and extremity digital radiographs.

    abstract::The authors present an adaptation of the macro recording feature on the Siemens Magic View 1000 workstation, which, with the click of one button, launches a macro that performs 3 clinically useful image manipulations. Using a Magic View 1004 Siemens unix workstation, the following Macro sequence was programmed: (1) se...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-002-5078-x

    authors: Koenker RM,Grover SA

    更新日期:2002-01-01 00:00:00

  • NIRViz: 3D visualization software for multimodality optical imaging using visualization toolkit (VTK) and insight segmentation toolkit (ITK).

    abstract::Optical imaging using near-infrared light is used for noninvasive probing of tissues to recover vascular and molecular status of healthy and diseased tissues using hemoglobin contrast arising due to absorption of light. While multimodality optical techniques exist, visualization techniques in this area are limited. Ad...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9362-5

    authors: Taka SJ,Srinivasan S

    更新日期:2011-12-01 00:00:00

  • A mobile tele-radiology imaging system with JPEG2000 for an emergency care.

    abstract::The aim of this study was to design a tele-radiology imaging system for rapid emergency care via mobile networks and to assess the diagnostic feasibility of the Joint Photographic Experts Group 2000 (JPEG2000) radiological imaging using portable devices. Rapid patient information and image exchange is helpful to make ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-010-9335-0

    authors: Kim DK,Kim EY,Yang KH,Lee CK,Yoo SK

    更新日期:2011-08-01 00:00:00

  • MABAL: a Novel Deep-Learning Architecture for Machine-Assisted Bone Age Labeling.

    abstract::Bone age assessment (BAA) is a commonly performed diagnostic study in pediatric radiology to assess skeletal maturity. The most commonly utilized method for assessment of BAA is the Greulich and Pyle method (Pediatr Radiol 46.9:1269-1274, 2016; Arch Dis Child 81.2:172-173, 1999) atlas. The evaluation of BAA can be a t...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0053-3

    authors: Mutasa S,Chang PD,Ruzal-Shapiro C,Ayyala R

    更新日期:2018-08-01 00:00:00

  • Design of a high-speed, high-resolution teleradiology network.

    abstract::A teleradiology system acquires radiographic images from one location and transmits them to one or more distant sites where they are displayed and/or converted to hard-copy film recordings. The long-term goal of teleradiology research is to show that teleradiology systems can provide diagnostically equivalent results ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167763

    authors: Stewart BK,Dwyer SJ 3rd,Kangarloo H

    更新日期:1992-08-01 00:00:00

  • Detection of breast cancer with a computer-aided detection applied to full-field digital mammography.

    abstract::A study was conducted to evaluate the sensitivity of computer-aided detection (CAD) with full-field digital mammography in detection of breast cancer, based on mammographic appearance and histopathology. Retrospectively, CAD sensitivity was assessed in total group of 152 cases for subgroups based on breast density, ma...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9564-5

    authors: Murakami R,Kumita S,Tani H,Yoshida T,Sugizaki K,Kuwako T,Kiriyama T,Hakozaki K,Okazaki E,Yanagihara K,Iida S,Haga S,Tsuchiya S

    更新日期:2013-08-01 00:00:00

  • The effects of ambient lighting in chest radiology reading rooms.

    abstract::Under typical dark chest radiography reading room conditions, a radiologist's pupils contract and dilate as their visual focus intermittently shifts between the high luminance monitor and the darker background wall, resulting in increased visual fatigue and degradation of diagnostic performance. A controlled increase ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9459-5

    authors: Pollard BJ,Samei E,Chawla AS,Beam C,Heyneman LE,Koweek LM,Martinez-Jimenez S,Washington L,Hashimoto N,McAdams HP

    更新日期:2012-08-01 00:00:00

  • Prostate tissue texture feature extraction for suspicious regions identification on TRUS images.

    abstract::In this work, two different approaches are proposed for region of interest (ROI) segmentation using transrectal ultrasound (TRUS) images. The two methods aim to extract informative features that are able to characterize suspicious regions in the TRUS images. Both proposed methods are based on multi-resolution analysis...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-008-9124-1

    authors: Mohamed SS,Li J,Salama MM,Freeman G

    更新日期:2009-10-01 00:00:00

  • Computer-aided detection of architectural distortion in prior mammograms of interval cancer.

    abstract::Architectural distortion is an important sign of breast cancer, but because of its subtlety, it is a common cause of false-negative findings on screening mammograms. This paper presents methods for the detection of architectural distortion in mammograms of interval cancer cases taken prior to the detection of breast c...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-009-9257-x

    authors: Rangayyan RM,Banik S,Desautels JE

    更新日期:2010-10-01 00:00:00

  • Understanding Clinical Mammographic Breast Density Assessment: a Deep Learning Perspective.

    abstract::Mammographic breast density has been established as an independent risk marker for developing breast cancer. Breast density assessment is a routine clinical need in breast cancer screening and current standard is using the Breast Imaging and Reporting Data System (BI-RADS) criteria including four qualitative categorie...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-017-0022-2

    authors: Mohamed AA,Luo Y,Peng H,Jankowitz RC,Wu S

    更新日期:2018-08-01 00:00:00

  • Automated routing of DICOM CT, MR, and CR images: solving the pitfalls of vendor-specific DICOM implementations.

    abstract::This paper details our experience in developing and implementing an automated DICOM Image Router. This workstation serves as a gateway between image acquisition devices and image display and storage devices. Images are checked for demographic input errors and data format inconsistencies between the source and destinat...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168283

    authors: Junck KL,McEachern M,Grandhi S,Lewey G

    更新日期:1998-08-01 00:00:00

  • The Enterprise Imaging Value Proposition.

    abstract::As resources in the healthcare environment continue to wane, leaders are seeking ways to continue to provide quality care bounded by the constraints of a reduced budget. This manuscript synthesizes the experience from a number of institutions to provide the healthcare leadership with an understanding of the value of a...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-019-00293-1

    authors: Petersilge CA

    更新日期:2020-02-01 00:00:00

  • Characterization of monochrome CRT display systems in the field.

    abstract::This article presents a review of image quality assessment methods for monochrome CRTs in the field as opposed to the laboratory. The review includes image quality programs at the University of Washington, the University of Texas at Houston, the University of Michigan, and the University of Arizona. CRT manufacturers ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168851

    authors: Roehrig H,Willis CE,Damento MA

    更新日期:1999-11-01 00:00:00

  • Environmental designs for reading from imaging work stations: ergonomic and architectural features.

    abstract::Despite the rapid progress made in the electronic design of imaging work stations for medicine, much less effort has gone into the design of environments in which such systems will be used. Based on studies of radiologist film reading sessions, considerable time will be spent working at such viewing systems. If the ro...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168035

    authors: Horii SC,Horii HN,Mun SK,Benson HR,Zeman RK

    更新日期:1989-08-01 00:00:00

  • Minimizing Digital Imaging and Communications in Medicine (DICOM) Modality Worklist patient/study selection errors.

    abstract::Frequently when patient and study identification information (patient name, patient identification, date of birth, sex, and accession number) are manually entered at a modality, typographical errors occur that have to be corrected before the acquired images can be matched to the proper patient and study on a picture a...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03190323

    authors: Kuzmak PM,Dayhoff RE

    更新日期:2001-06-01 00:00:00

  • Ruler Based Automatic C-Arm Image Stitching Without Overlapping Constraint.

    abstract::In this paper, we propose a new method for stitching multiple fluoroscopic images taken by a C-arm instrument. We employ an X-ray radiolucent ruler with numbered graduations while acquiring the images, and the image stitching is based on detecting and matching ruler parts in the images to the corresponding parts of a ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-014-9763-3

    authors: Chen C,Kojcev R,Haschtmann D,Fekete T,Nolte L,Zheng G

    更新日期:2015-08-01 00:00:00

  • Classification of CT Scan Images of Lungs Using Deep Convolutional Neural Network with External Shape-Based Features.

    abstract::In this paper, a simplified yet efficient architecture of a deep convolutional neural network is presented for lung image classification. The images used for classification are computed tomography (CT) scan images obtained from two scientifically used databases available publicly. Six external shape-based features, vi...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00245-9

    authors: Srivastava V,Purwar RK

    更新日期:2020-02-01 00:00:00

  • Estimates of Patient Radiation Doses in Digital Radiography Using DICOM Information at a Large Teaching Hospital in Oman.

    abstract::In this study, we sought to estimate the patient radiation doses in the digital radiography X-ray examinations conducted in a large hospital. The patient exposure factors and kerma-area product (PKA) were retrospectively recorded via the Digital Imaging and Communications in Medicine (DICOM) header for 547 patients. T...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00199-y

    authors: Suliman II

    更新日期:2020-02-01 00:00:00

  • The effect of lossy discrete cosine transform compression on subtle bone fractures.

    abstract::Extensive research efforts have been devoted to the feasibility of picture archiving and communication systems (PACS) in recent years. The advantages of PACS are numerous but mainly include reduced cost and improvement in the operational efficiency of a PACS-based radiology department. In digital radiography, images a...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168839

    authors: Toney MO,Dominguez R,Dao HN,Simmons G

    更新日期:1997-11-01 00:00:00

  • Analog to digital workflow improvement: a quantitative study.

    abstract::This study tracked a radiology department's conversion from utilization of a Kodak Amber analog system to a Kodak DirectView DR 5100 digital system. Through the use of ProModel Optimization Suite, a workflow simulation software package, significant quantitative information was derived from workflow process data measur...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-0770-x

    authors: Wideman C,Gallet J

    更新日期:2006-01-01 00:00:00

  • A computerized analysis system in chest radiography: evaluation of interstitial lung abnormalities.

    abstract::We evaluated the usefulness of a computerized analysis system in the detection of interstitial lung abnormalities in digitized chest radiography. This system uses the processes of four-directional Laplacian-Gaussian filtering, linear opacity judgment, and linear opacity subtraction. For qualitative analysis, we employ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168557

    authors: Kido S,Ikezoe J,Tamura S,Nakamura H,Kuroda C

    更新日期:1997-05-01 00:00:00

  • Research and teaching access to a large clinical picture archiving and communication system.

    abstract:PURPOSE:To identify practical issues surrounding delivering digital images from picture archiving and communication systems (PACS) for research and teaching purposes. The complexity of Digital Imaging and Communications in Medicine (DICOM) access methods, security, patient confidentiality, PACS database integrity, port...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03190313

    authors: Harrison M,Koh J,Tran S,Mongkolwat P,Channin DS

    更新日期:2001-06-01 00:00:00

  • Towards Portable Large-Scale Image Processing with High-Performance Computing.

    abstract::High-throughput, large-scale medical image computing demands tight integration of high-performance computing (HPC) infrastructure for data storage, job distribution, and image processing. The Vanderbilt University Institute for Imaging Science (VUIIS) Center for Computational Imaging (CCI) has constructed a large-scal...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-018-0080-0

    authors: Huo Y,Blaber J,Damon SM,Boyd BD,Bao S,Parvathaneni P,Noguera CB,Chaganti S,Nath V,Greer JM,Lyu I,French WR,Newton AT,Rogers BP,Landman BA

    更新日期:2018-06-01 00:00:00

  • DICOM versus HL7 for modality interfacing.

    abstract::Digital modalities such as CT, MRI, Ultrasound and Computerized Radiography systems, generating softcopy images to be used by a Picture Archiving and Communication System (PACS), need to identify the images properly in order to retrieve and manage them. In many cases, a technologist re-enters patient demographic and s...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/BF03168256

    authors: Oosterwijk H

    更新日期:1998-08-01 00:00:00

  • Volumetric Assessment of Pediatric Vascular Malformations Using a Rapid, Hand-Held Three-Dimensional Imaging System.

    abstract::The effect of percutaneous, surgical, and medical therapies for vascular malformations (VMs) is often difficult to quantify volumetrically using cross-sectional imaging. Volumetric measurement is often estimated with serial, expensive MRI examinations which may require sedation or anesthesia. We aim to explore whether...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00183-6

    authors: Speir EJ,Matthew Hawkins C,Weiler MJ,Briones M,Swerdlin R,Park S,Brandon Dixon J

    更新日期:2019-04-01 00:00:00

  • Touch Surgery: a Twenty-First Century Platform for Surgical Training.

    abstract::This manuscript reviews Touch Surgery, a novel online platform geared towards innovating professional training for surgical procedures. In other industries, such as aviation, simulation has already been shown to reduce costs and improve outcomes in crisis (JETS 3(4):348-352, 2010). Studies involving simulation-based l...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-018-0102-y

    authors: Mandler AG

    更新日期:2018-10-01 00:00:00

  • Analysis of the X-ray work flow in two diagnostic imaging departments with and without a RIS/PACS system.

    abstract::A traditional radiological workflow is compared with one based on radiology information system/picture archiving and communication system (RIS/PACS). X-ray workflow process was considered in both radiology departments. First, the study identified the main phases of the research work as follows: Process Analysis, Data ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-0858-3

    authors: Mariani C,Tronchi A,Oncini L,Pirani O,Murri R

    更新日期:2006-01-01 00:00:00

  • Comparison of algorithms to enhance spicules of spiculated masses on mammography.

    abstract::We have developed an algorithm for enhancement of spicules of spiculated masses, which uses the discrete radon transform. Previously, we employed a commonly used method to compute the discrete radon transform, which we refer to as the DRT. Recently, a new, more exact method to compute the discrete radon transform was ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-007-9015-x

    authors: Sampat MP,Whitman GJ,Bovik AC,Markey MK

    更新日期:2008-03-01 00:00:00

  • Computed radiography in pediatrics.

    abstract::Computed radiography (CR) has various advantages such as dynamic range. Diagnostic accuracy with CR using reduced radiation dose is considered comparable with that of conventional film-screen radiography in diagnosing apparent chest abnormalities. In addition to reducing the radiation dose, delineation of the various ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168076

    authors: Aoki K

    更新日期:1995-02-01 00:00:00