Clinical impact of picture archiving and communication systems: evaluation of a prototype system.

Abstract:

:Opinion surveys were gathered before and 6 months after installation of a prototype picture archiving and communication system (PACS) (PACS/1, Siemens Medical Systems, Iselin, NJ). Median turnaround times and the percent of delayed or missing reports were calculated for 1,026 baseline and 8,438 follow-up studies at 6 months. Neuroradiological (neuro) computed tomography (CT) used PACS, while neuro magnetic resonance (MR), body CT, and body MR served as controls. The opinion surveys showed improved service in all categories, including those not directly affected by PACS. PACS images favorably impressed 86% of respondents, but most considered the system too slow, unreliable, and the storage capacity too low. A majority of 81% recommended against purchase of PACS now. There was an overall increase in the median report turnaround time for both neuro CT and the controls. Neuro CT showed a 41% decrease in delayed or missing reports, but controls also showed similar decreases. The effects of this prototype PACS on turnaround time or on report delivery could not be distinguished from section-wide changes in CT and MR services. Future improvements in PACS should vigorously address increased speed, reliability, and storage capacity.

journal_name

J Digit Imaging

authors

Worrell JA,Federspiel CF,Creasy JL,Pickens DR 3rd,Higginbotham K,Patton JA,Partain CL

doi

10.1007/BF03167836

subject

Has Abstract

pub_date

1992-05-01 00:00:00

pages

118-25

issue

2

eissn

0897-1889

issn

1618-727X

journal_volume

5

pub_type

杂志文章
  • A IHE-Like Approach Method for Quantitative Analysis of PACS Usage.

    abstract::Today, many hospitals have a running enterprise picture archiving and communication system (PACS) and their administrators should have the tools to measure the system activity and, in particular, how much it is used. The information would be valuable for decision-makers to address asset management and the development ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-016-9870-4

    authors: Calabrese R,Beltrame M,Accardo A

    更新日期:2016-12-01 00:00:00

  • A mobile tele-radiology imaging system with JPEG2000 for an emergency care.

    abstract::The aim of this study was to design a tele-radiology imaging system for rapid emergency care via mobile networks and to assess the diagnostic feasibility of the Joint Photographic Experts Group 2000 (JPEG2000) radiological imaging using portable devices. Rapid patient information and image exchange is helpful to make ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-010-9335-0

    authors: Kim DK,Kim EY,Yang KH,Lee CK,Yoo SK

    更新日期:2011-08-01 00:00:00

  • Integrated voice recognition and picture archiving and communication system: development and early experience.

    abstract::Voice recognition (VR) and picture archiving and communication system (PACS) both have advantages and disadvantages in radiologic practice. We describe a fully integrated VR/PACS system running on a single platform. Integration optimizes the positive features of both systems and creates a synergy that is not otherwise...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03190351

    authors: Weiss DL,Hoffman J,Kustas G

    更新日期:2001-06-01 00:00:00

  • Feature-Motivated Simplified Adaptive PCNN-Based Medical Image Fusion Algorithm in NSST Domain.

    abstract::Multimodality medical image fusion plays a vital role in diagnosis, treatment planning, and follow-up studies of various diseases. It provides a composite image containing critical information of source images required for better localization and definition of different organs and lesions. In the state-of-the-art imag...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-015-9806-4

    authors: Ganasala P,Kumar V

    更新日期:2016-02-01 00:00:00

  • A novel medical image quality index.

    abstract::A novel medical image quality index using grey relational coefficient calculation is proposed in this study. Three medical modalities, DR, CT and MRI, using 30 or 60 images with a total of 120 images used for experimentation. These images were first compressed at ten different compression ratios (10 ∼ 100) using a med...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-010-9353-y

    authors: Lin SC,Lin YC,Feng WS,Wu JM,Chen TJ

    更新日期:2011-10-01 00:00:00

  • NIRViz: 3D visualization software for multimodality optical imaging using visualization toolkit (VTK) and insight segmentation toolkit (ITK).

    abstract::Optical imaging using near-infrared light is used for noninvasive probing of tissues to recover vascular and molecular status of healthy and diseased tissues using hemoglobin contrast arising due to absorption of light. While multimodality optical techniques exist, visualization techniques in this area are limited. Ad...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9362-5

    authors: Taka SJ,Srinivasan S

    更新日期:2011-12-01 00:00:00

  • A breast density index for digital mammograms based on radiologists' ranking.

    abstract::The purpose of this study was to develop and evaluate a computerized method of calculating a breast density index (BDI) from digitized mammograms that was designed specifically to model radiologists' perception of breast density. A set of 153 pairs of digitized mammograms (cranio-caudal, CC, and mediolateral oblique, ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168733

    authors: Boone JM,Lindfors KK,Beatty CS,Seibert JA

    更新日期:1998-08-01 00:00:00

  • The effect of slice thickness on the assessment of bone defect volumes by the Cavalieri principle using cone beam computed tomography.

    abstract::The purpose of this study was to investigate the possible effects of section thickness on volume estimations obtained by cone beam computed tomography. Intraosseal cavities representing bone defects on vestibular sides of the two dry sheep mandibles were scanned by a cone beam computed tomography system. Consecutive s...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9480-8

    authors: Sezgin OS,Kayıpmaz S,Sahin B

    更新日期:2013-02-01 00:00:00

  • A heuristic approach to automated nipple detection in digital mammograms.

    abstract::In this paper, a heuristic approach to automated nipple detection in digital mammograms is presented. A multithresholding algorithm is first applied to segment the mammogram and separate the breast region from the background region. Next, the problem is considered separately for craniocaudal (CC) and mediolateral-obli...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9575-x

    authors: Jas M,Mukhopadhyay S,Chakraborty J,Sadhu A,Khandelwal N

    更新日期:2013-10-01 00:00:00

  • Effect of Interventional Program on the Utilization of PACS in Point-of-Care Ultrasound.

    abstract::While the implementation of Picture Archiving and Communication Systems (PACS) has revolutionized the field of radiology, there has been considerably less utilization of PACS by emergency physicians with point-of-care ultrasound. Benefits of PACS archival of images include improved quality assurance, preservation of i...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-016-9893-x

    authors: Kessler R,Stowell JR,Vogel JA,Liao MM,Kendall JL

    更新日期:2016-12-01 00:00:00

  • An assessment of the iPad 2 as a CT teleradiology tool using brain CT with subtle intracranial hemorrhage under conventional illumination.

    abstract::We examined the potential of the iPad 2 as a teleradiologic tool for evaluating brain computed tomography (CT) with subtle hemorrhage in the conventional lighting conditions which are common situations in the remote CT reading. The comparison of the clinician's performance was undertaken through detecting hemorrhage b...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9580-0

    authors: Park JB,Choi HJ,Lee JH,Kang BS

    更新日期:2013-08-01 00:00:00

  • Displaying radiologic images on personal computers.

    abstract::This is the second article of our series for radiologists and imaging scientists on displaying, manipulating, and analyzing radiologic images on personal computers (PCs). The first article discussed the digital image data file, standard PC graphic file formats, and various methods for importing radiologic images into ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168488

    authors: Gillespy T 3rd,Rowberg AH

    更新日期:1993-08-01 00:00:00

  • Classification of breast masses using selected shape, edge-sharpness, and texture features with linear and kernel-based classifiers.

    abstract::Breast masses due to benign disease and malignant tumors related to breast cancer differ in terms of shape, edge-sharpness, and texture characteristics. In this study, we evaluate a set of 22 features including 5 shape factors, 3 edge-sharpness measures, and 14 texture features computed from 111 regions in mammograms,...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-007-9102-z

    authors: Mu T,Nandi AK,Rangayyan RM

    更新日期:2008-06-01 00:00:00

  • An ROC study of chest radiographs: 2K Versus 4K high-resolution soft-copy images.

    abstract::Computed radiography of chest with a 4K image array was recently introduced. We performed a multiobserver study to compare the diagnostic accuracy of 2K (standard) and 4K (high quality) chest radiographs displayed on a 5-mega-pixel monitor (2K monitor). One hundred cases of posteroanterior chest radiographs (a total o...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-1048-z

    authors: Kim SY,Hwang YJ,Han YH,Seo JW,Lee JY,Kim YH,Cha SJ,Hur G,Lee SS

    更新日期:2007-12-01 00:00:00

  • Assessment of coronary artery calcium using dual-energy subtraction digital radiography.

    abstract::Cardiovascular disease is the leading cause of global mortality, yet its early detection remains a vexing problem of modern medicine. Although the computed tomography (CT) calcium score predicts cardiovascular risk, relatively high cost ($250-400) and radiation dose (1-3 mSv) limit its universal utility as a screening...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9385-y

    authors: Mafi JN,Fei B,Roble S,Dota A,Katrapati P,Bezerra HG,Wang H,Wang W,Ciancibello L,Costa M,Simon DI,Orringer CE,Gilkeson RC

    更新日期:2012-02-01 00:00:00

  • Precise measurement of vertebral bone density using computed tomography without the use of an external reference phantom.

    abstract::Bone density measurement by quantitative computed tomography (QCT) commonly uses an external reference phantom to decrease scan-to-scan and scanner-to-scanner variability. However, the peripheral location of these phantoms and other phantom variables is also responsible for a measurable degradation in accuracy and pre...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168013

    authors: Boden SD,Goodenough DJ,Stockham CD,Jacobs E,Dina T,Allman RM

    更新日期:1989-02-01 00:00:00

  • CD-based image archival and management on a hybrid radiology intranet.

    abstract::This article describes the design and implementation of a low-cost image archival and management solution on a radiology network consisting of UNIX, IBM personal computer-compatible (IBM, Purchase, NY) and Macintosh (Apple Computer, Cupertino, CA) workstations. The picture archiving and communications system (PACS) is...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168688

    authors: Cox RD,Henri CJ,Bret PM

    更新日期:1997-08-01 00:00:00

  • 3D Brain Imaging in Vascular Segmentation of Cerebral Venous Sinuses.

    abstract::The three-dimensional (3D) visualization of dural venous sinuses (DVS) networks is desired by surgical trainers to create a clear mental picture of the neuroanatomical orientation of the complex cerebral anatomy. Our purpose is to document those identified during routine 3D venography created through 3D models using t...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0125-4

    authors: Karakas AB,Govsa F,Ozer MA,Eraslan C

    更新日期:2019-04-01 00:00:00

  • Digital processing of radiographic images from PACS to publishing.

    abstract::Several studies have addressed the implications of filmless radiologic imaging on telemedicine, diagnostic ability, and electronic teaching files. However, many publishers still require authors to submit hard-copy images for publication of articles and textbooks. This study compares the quality digital images directly...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-001-0019-7

    authors: Christian ME,Davidson HC,Wiggins RH 3rd,Berges G,Cannon G,Jackson G,Chapman B,Harnsberger HR

    更新日期:2001-03-01 00:00:00

  • SCAR R&D Symposium 2003: comparing the efficacy of 5-MP CRT versus 3-MP LCD in the evaluation of interstitial lung disease.

    abstract::The efficacy of two medical-grade, self-calibrating, gray scale displays were compared with regard to impact on sensitivity and specificity for the detection of interstitial lung disease (ILD) on computed radiographs (CR). The displays were a 5-megapixel (MP) cathode ray tube (CRT) device and a 3-MP liquid crystal dis...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-004-1013-7

    authors: Langer S,Bartholmai B,Fetterly K,Harmsen S,Ryan W,Erickson B,Andriole K,Carrino J

    更新日期:2004-09-01 00:00:00

  • Comparative performance analysis of state-of-the-art classification algorithms applied to lung tissue categorization.

    abstract::In this paper, we compare five common classifier families in their ability to categorize six lung tissue patterns in high-resolution computed tomography (HRCT) images of patients affected with interstitial lung diseases (ILD) and with healthy tissue. The evaluated classifiers are naive Bayes, k-nearest neighbor, J48 d...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-008-9158-4

    authors: Depeursinge A,Iavindrasana J,Hidki A,Cohen G,Geissbuhler A,Platon A,Poletti PA,Müller H

    更新日期:2010-02-01 00:00:00

  • 10 Steps to Strategically Build and Implement your Enterprise Imaging System: HIMSS-SIIM Collaborative White Paper.

    abstract::An enterprise imaging (EI) strategy is an organized plan to optimize the electronic health record (EHR) so that healthcare providers have intuitive and immediate access to all patient clinical images and their associated documentation, regardless of source. We describe ten steps recommended to achieve the goal of impl...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-019-00236-w

    authors: Primo H,Bishop M,Lannum L,Cram D,Nader A,Boodoo R

    更新日期:2019-08-01 00:00:00

  • Minimizing Barriers in Learning for On-Call Radiology Residents-End-to-End Web-Based Resident Feedback System.

    abstract::Feedback is an essential part of medical training, where trainees are provided with information regarding their performance and further directions for improvement. In diagnostic radiology, feedback entails a detailed review of the differences between the residents' preliminary interpretation and the attendings' final ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-017-0015-1

    authors: Choi HH,Clark J,Jay AK,Filice RW

    更新日期:2018-02-01 00:00:00

  • Automatically correlating clinical findings and body locations in radiology reports using MedLEE.

    abstract::In this paper, we describe and evaluate a system that extracts clinical findings and body locations from radiology reports and correlates them. The system uses Medical Language Extraction and Encoding System (MedLEE) to map the reports' free text to structured semantic representations of their content. A lightweight r...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9411-0

    authors: Sevenster M,van Ommering R,Qian Y

    更新日期:2012-04-01 00:00:00

  • INDIAM--an e-learning system for the interpretation of mammograms.

    abstract::We propose the design of a teaching system named Interpretation and Diagnosis of Mammograms (INDIAM) for training students in the interpretation of mammograms and diagnosis of breast cancer. The proposed system integrates an illustrated tutorial on radiology of the breast, that is, mammography, which uses education te...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-008-9111-6

    authors: Guliato D,Bôaventura RS,Maia MA,Rangayyan RM,Simedo MS,Macedo TA

    更新日期:2009-08-01 00:00:00

  • A Decision-Support Tool for Renal Mass Classification.

    abstract::We investigate the viability of statistical relational machine learning algorithms for the task of identifying malignancy of renal masses using radiomics-based imaging features. Features characterizing the texture, signal intensity, and other relevant metrics of the renal mass were extracted from multiphase contrast-e...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0100-0

    authors: Kunapuli G,Varghese BA,Ganapathy P,Desai B,Cen S,Aron M,Gill I,Duddalwar V

    更新日期:2018-12-01 00:00:00

  • Of Mice and Roentgen: Radiologist Satisfaction with a Non-conventional 13-Button Mouse-One Institution's Experience.

    abstract::Increasing radiologic exam volume and complexity necessitates leveraging advanced hardware solutions to optimize workflow efficiency. We evaluated radiologist satisfaction of a programmable 13-button non-conventional mouse compared to a conventional three-button mouse in daily interpretation workflow following a brief...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0094-7

    authors: Denton K,Haider I,Hill J,Hunt SL,Ash R

    更新日期:2018-12-01 00:00:00

  • An effective approach of lesion segmentation within the breast ultrasound image based on the cellular automata principle.

    abstract::In this paper, a novel lesion segmentation within breast ultrasound (BUS) image based on the cellular automata principle is proposed. Its energy transition function is formulated based on global image information difference and local image information difference using different energy transfer strategies. First, an en...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9450-6

    authors: Liu Y,Cheng HD,Huang J,Zhang Y,Tang X

    更新日期:2012-10-01 00:00:00

  • A method for computing general sacroiliac screw corridors based on CT scans of the pelvis.

    abstract::Sacroiliac (SI) joint dislocations and sacral fractures of the pelvis can be stabilized by SI screws; however, screw insertion into a sacral isthmus region is risky for the adjacent neurovascular structures. Therefore, shape analyses of general SI screw corridors or safety zones are of great surgical interest; however...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-010-9327-0

    authors: Noser H,Radetzki F,Stock K,Mendel T

    更新日期:2011-08-01 00:00:00

  • The Effect of Registration on Voxel-Wise Tofts Model Parameters and Uncertainties from DCE-MRI of Early-Stage Breast Cancer Patients Using 3DSlicer.

    abstract::We quantitatively investigate the influence of image registration, using open-source software (3DSlicer), on kinetic analysis (Tofts model) of dynamic contrast enhanced MRI of early-stage breast cancer patients. We also show that registration computation time can be reduced by reducing the percent sampling (PS) of vox...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-020-00374-6

    authors: Mouawad M,Biernaski H,Brackstone M,Lock M,Kornecki A,Shmuilovich O,Ben-Nachum I,Prato FS,Thompson RT,Gaede S,Gelman N

    更新日期:2020-10-01 00:00:00