Online Radiology Reporting with Peer Review as a Learning and Feedback Tool in Radiology; Implementation, Validity, and Student Impressions.

Abstract:

:Communicating radiological reports to peers has pedagogical value. Students may be uneasy with the process due to a lack of communication and peer review skills or to their failure to see value in the process. We describe a communication exercise with peer review in an undergraduate veterinary radiology course. The computer code used to manage the course and deliver images online is reported, and we provide links to the executable files. We tested to see if undergraduate peer review of radiological reports has validity and describe student impressions of the learning process. Peer review scores for student-generated radiological reports were compared to scores obtained in the summative multiple choice (MCQ) examination for the course. Student satisfaction was measured using a bespoke questionnaire. There was a weak positive correlation (Pearson correlation coefficient = 0.32, p < 0.01) between peer review scores students received and the student scores obtained in the MCQ examination. The difference in peer review scores received by students grouped according to their level of course performance (high vs. low) was statistically significant (p < 0.05). No correlation was found between peer review scores awarded by the students and the scores they obtained in the MCQ examination (Pearson correlation coefficient = 0.17, p = 0.14). In conclusion, we have created a realistic radiology imaging exercise with readily available software. The peer review scores are valid in that to a limited degree they reflect student future performance in an examination. Students valued the process of learning to communicate radiological findings but do not fully appreciated the value of peer review.

journal_name

J Digit Imaging

authors

McEvoy FJ,Shen NW,Nielsen DH,Buelund LE,Holm P

doi

10.1007/s10278-016-9905-x

subject

Has Abstract

pub_date

2017-02-01 00:00:00

pages

78-85

issue

1

eissn

0897-1889

issn

1618-727X

pii

10.1007/s10278-016-9905-x

journal_volume

30

pub_type

杂志文章
  • Automated detection of z-axis coverage with abdomen-pelvis computed tomography examinations.

    abstract::Excessive cephalocaudal anatomic (Z-axis) coverage can lead to unnecessary radiation exposure to a patient. In this study, an automated computing model was developed for identifying instances of potentially excessive Z-axis coverage with abdomen-pelvis examinations. Eight patient and imaging attributes including patie...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-014-9743-7

    authors: Zhang M,Wellnitz C,Cui C,Pavlicek W,Wu T

    更新日期:2015-06-01 00:00:00

  • Detection of cancerous masses in mammograms by template matching: optimization of template brightness distribution by means of evolutionary algorithm.

    abstract::Optimization of brightness distribution in the template used for detection of cancerous masses in mammograms by means of correlation coefficient is presented. This optimization is performed by the evolutionary algorithm using an auxiliary mass classifier. Brightness along the radius of the circularly symmetric templat...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9402-1

    authors: Bator M,Nieniewski M

    更新日期:2012-02-01 00:00:00

  • Stereoscopic interpretation of low-dose breast tomosynthesis projection images.

    abstract::The purpose of this study was to evaluate stereoscopic perception of low-dose breast tomosynthesis projection images. In this Institutional Review Board exempt study, craniocaudal breast tomosynthesis cases (N = 47), consisting of 23 biopsy-proven malignant mass cases and 24 normal cases, were retrospectively reviewed...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9648-x

    authors: Muralidhar GS,Markey MK,Bovik AC,Haygood TM,Stephens TW,Geiser WR,Garg N,Adrada BE,Dogan BE,Carkaci S,Khisty R,Whitman GJ

    更新日期:2014-04-01 00:00:00

  • Development of a noise reduction filter algorithm for pediatric body images in multidetector CT.

    abstract::Recently, several types of post-processing image filter which was designed to reduce noise allowing a corresponding dose reduction in CT images have been proposed and these were reported to be useful for noise reduction of CT images of adult patients. However, these have not been reported on adaptation for pediatric p...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-009-9218-4

    authors: Nishimaru E,Ichikawa K,Okita I,Tomoshige Y,Kurokawa T,Nakamura Y,Suzuki M

    更新日期:2010-12-01 00:00:00

  • A study of radiologists viewing multiple computed tomography examinations using an eyetracking device.

    abstract::Understanding the scan patterns radiologists use to view medical images is critical to the design of image viewing devices. In this study, an eyetracker, a device for recording eye and head movement, was used to determine the scan patterns during the interpretation of single and multiple computed tomographic (CT) exam...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168120

    authors: Beard DV,Johnston RE,Toki O,Wilcox C

    更新日期:1990-11-01 00:00:00

  • Early lung cancer detection using the self-evaluation scoring questionnaire and chest digital radiography: a 3-year follow-up study in China.

    abstract::The standard definition of high-risk individuals for lung cancer was not uniform and the value of chest digital radiography (DR) in lung cancer screening was still unproven. The aim of this study was to assess whether the original questionnaire named as "Self-evaluation Scoring Questionnaire for High-risk Individuals ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9468-4

    authors: Chen B,Wang Y,Cao H,Liu D,Zhang S,Gao J,Yu J,Huang Y,Li W

    更新日期:2013-02-01 00:00:00

  • Financial assessment of a picture archiving and communication system implemented all at once.

    abstract::The objective of this study was to determine the differential cost between film-based radiology and a hospital-wide picture archiving and communication system (PACS) implemented all at once. The cash flow and running costs of PACS and film-based operation were measured over an 8-year time horizon. When the hospital-wi...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-0632-6

    authors: Fang YC,Yang MC,Hsueh YS

    更新日期:2006-01-01 00:00:00

  • Demonstration of digital radiographs by means of ink jet-printed paper copies: pilot study.

    abstract::Different digital medical images have been printed on paper with a continuous ink jet printer, and the quality has been evaluated. The emphasis has been on digital chest radiographs from a computed radiography system. The ink jet printing technique is described as well as the handling of the image data from image sour...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167806

    authors: Kirkhorn T,Kehler M,Nilsson J,Lyttkens K,Andersson B,Holmer NG

    更新日期:1992-11-01 00:00:00

  • A Pilot Study on the Development of Remote Quality Control of Digital Mammography Systems in the NHS Breast Screening Programme.

    abstract::In the UK, physicists and radiographers perform routine quality control (QC) of digital mammography equipment at daily, weekly and monthly intervals. The tests performed and tolerances are specified by standard protocols. The manual nature of many of the tests introduces variability due to the positioning of regions o...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-014-9759-z

    authors: Looney P,Halling-Brown MD,Oduko JM,Young KC

    更新日期:2015-10-01 00:00:00

  • Using the Microsoft Kinect for patient size estimation and radiation dose normalization: proof of concept and initial validation.

    abstract::Monitoring patients' imaging-related radiation is currently a hot topic, but there are many obstacles to accurate, patient-specific dose estimation. While some, such as easier access to dose data and parameters, have been overcome, the challenge remains as to how accurately these dose estimates reflect the actual dose...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9567-2

    authors: Cook TS,Couch G,Couch TJ,Kim W,Boonn WW

    更新日期:2013-08-01 00:00:00

  • Incorporating out-patient data from CD-R into the local PACS using DICOM worklist features.

    abstract::With the introduction of digital imaging in radiology, CD-Rs are increasingly used to distribute patient materials. This study investigates the application of a new software package and work protocol to integrate out-hospital data into the local PACS (picture archive and communication system) archive, which is hampere...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-005-5158-9

    authors: van Ooijen PM,Guignot J,Mevel G,Oudkerk M

    更新日期:2005-09-01 00:00:00

  • 3D Brain Imaging in Vascular Segmentation of Cerebral Venous Sinuses.

    abstract::The three-dimensional (3D) visualization of dural venous sinuses (DVS) networks is desired by surgical trainers to create a clear mental picture of the neuroanatomical orientation of the complex cerebral anatomy. Our purpose is to document those identified during routine 3D venography created through 3D models using t...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0125-4

    authors: Karakas AB,Govsa F,Ozer MA,Eraslan C

    更新日期:2019-04-01 00:00:00

  • Imaging Informatics Fellowship Curriculum: a Survey to Identify Core Topics and Potential Inter-Program Areas of Collaboration.

    abstract::New consumer technologies and interoperability standards have dated the first standardized curriculum for imaging informatics fellowships suggested by the Society for Computer Applications in Radiology (SCAR) in 2004 (Journal of digital imaging 17(4):244-248, 2004). Last year, analysis from this institution characteri...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00292-2

    authors: Makeeva V,Vey B,Cook TS,Nagy P,Filice RW,Wang KC,Balthazar P,Harri P,Safdar NM

    更新日期:2020-04-01 00:00:00

  • An assessment of the iPad 2 as a CT teleradiology tool using brain CT with subtle intracranial hemorrhage under conventional illumination.

    abstract::We examined the potential of the iPad 2 as a teleradiologic tool for evaluating brain computed tomography (CT) with subtle hemorrhage in the conventional lighting conditions which are common situations in the remote CT reading. The comparison of the clinician's performance was undertaken through detecting hemorrhage b...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9580-0

    authors: Park JB,Choi HJ,Lee JH,Kang BS

    更新日期:2013-08-01 00:00:00

  • 10 Steps to Strategically Build and Implement your Enterprise Imaging System: HIMSS-SIIM Collaborative White Paper.

    abstract::An enterprise imaging (EI) strategy is an organized plan to optimize the electronic health record (EHR) so that healthcare providers have intuitive and immediate access to all patient clinical images and their associated documentation, regardless of source. We describe ten steps recommended to achieve the goal of impl...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-019-00236-w

    authors: Primo H,Bishop M,Lannum L,Cram D,Nader A,Boodoo R

    更新日期:2019-08-01 00:00:00

  • A perceptual evaluation of JPEG 2000 image compression for digital mammography: contrast-detail characteristics.

    abstract::In this investigation the effect of JPEG 2000 compression on the contrast-detail (CD) characteristics of digital mammography images was studied using an alternative forced choice (AFC) technique. Images of a contrast-detail phantom, acquired using a clinical full-field digital mammography system, were compressed using...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-003-1728-x

    authors: Suryanarayanan S,Karellas A,Vedantham S,Waldrop SM,D'Orsi CJ

    更新日期:2004-03-01 00:00:00

  • DICOM versus HL7 for modality interfacing.

    abstract::Digital modalities such as CT, MRI, Ultrasound and Computerized Radiography systems, generating softcopy images to be used by a Picture Archiving and Communication System (PACS), need to identify the images properly in order to retrieve and manage them. In many cases, a technologist re-enters patient demographic and s...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/BF03168256

    authors: Oosterwijk H

    更新日期:1998-08-01 00:00:00

  • Towards a repository for standardized medical image and signal case data annotated with ground truth.

    abstract::Validation of medical signal and image processing systems requires quality-assured, representative and generally acknowledged databases accompanied by appropriate reference (ground truth) and clinical metadata, which are composed laboriously for each project and are not shared with the scientific community. In our vis...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9428-4

    authors: Deserno TM,Welter P,Horsch A

    更新日期:2012-04-01 00:00:00

  • Toward Automatic Detection of Radiation-Induced Cerebral Microbleeds Using a 3D Deep Residual Network.

    abstract::Cerebral microbleeds, which are small focal hemorrhages in the brain that are prevalent in many diseases, are gaining increasing attention due to their potential as surrogate markers of disease burden, clinical outcomes, and delayed effects of therapy. Manual detection is laborious and automatic detection and labeling...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0146-z

    authors: Chen Y,Villanueva-Meyer JE,Morrison MA,Lupo JM

    更新日期:2019-10-01 00:00:00

  • Challenges associated with interfacing computed tomography to a picture archiving and communication system at the Baltimore Veterans Affairs Medical Center--a historical perspective.

    abstract::The interfacing of digital image acquisition modalities to the picture archiving and communication system (PACS) plays a major part in the conversion from a traditional film-based radiology practice to one that relies almost entirely on soft-copy reading. The Baltimore Veterans Affairs Medical Center (VAMC) is one of ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167632

    authors: Kuzmak PM,Reiner BI,Siegel EL,Severance SM,Dayhoff RE

    更新日期:2000-05-01 00:00:00

  • Patient-specific three-dimensional composite bone models for teaching and operation planning.

    abstract:BACKGROUND:Orthopedic trauma care relies on two-dimensional radiograms both before and during the operation. Understanding the three-dimensional nature of complex fractures on plain radiograms is challenging. Modern fluoroscopes can acquire three-dimensional volume datasets even during an operation, but the device limi...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-007-9078-8

    authors: Matthews F,Messmer P,Raikov V,Wanner GA,Jacob AL,Regazzoni P,Egli A

    更新日期:2009-10-01 00:00:00

  • Computed radiography in pediatrics.

    abstract::Computed radiography (CR) has various advantages such as dynamic range. Diagnostic accuracy with CR using reduced radiation dose is considered comparable with that of conventional film-screen radiography in diagnosing apparent chest abnormalities. In addition to reducing the radiation dose, delineation of the various ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168076

    authors: Aoki K

    更新日期:1995-02-01 00:00:00

  • A study on the feasibility of active contours on automatic CT bone segmentation.

    abstract::Automatic bone segmentation of computed tomography (CT) images is an important step in image-guided surgery that requires both high accuracy and minimal user interaction. Previous attempts include global thresholding, region growing, region competition, watershed segmentation, and parametric active contour (AC) approa...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-009-9210-z

    authors: Truc PT,Kim TS,Lee S,Lee YK

    更新日期:2010-12-01 00:00:00

  • Analysis of the X-ray work flow in two diagnostic imaging departments with and without a RIS/PACS system.

    abstract::A traditional radiological workflow is compared with one based on radiology information system/picture archiving and communication system (RIS/PACS). X-ray workflow process was considered in both radiology departments. First, the study identified the main phases of the research work as follows: Process Analysis, Data ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-0858-3

    authors: Mariani C,Tronchi A,Oncini L,Pirani O,Murri R

    更新日期:2006-01-01 00:00:00

  • Expanding the functionality of speech recognition in radiology: creating a real-time methodology for measurement and analysis of occupational stress and fatigue.

    abstract::While occupational stress and fatigue have been well described throughout medicine, the radiology community is particularly susceptible due to declining reimbursements, heightened demands for service deliverables, and increasing exam volume and complexity. The resulting occupational stress can be variable in nature an...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9540-0

    authors: Reiner BI

    更新日期:2013-02-01 00:00:00

  • An artificial immune-activated neural network applied to brain 3D MRI segmentation.

    abstract::In this paper, a new neural network model inspired by the biological immune system functions is presented. The model, termed Artificial Immune-Activated Neural Network (AIANN), extracts classification knowledge from a training data set, which is then used to classify input patterns or vectors. The AIANN is based on a ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-007-9081-0

    authors: Younis A,Ibrahim M,Kabuka M,John N

    更新日期:2008-10-01 00:00:00

  • A filmless radiology teaching conference system for pertinent displaying and image searching.

    abstract::To solve the problems of image displays in filmless radiology conferences for the purpose of teaching, we made an experimental design of a conference system with dual 50-in. plasma monitors for displaying larger images and a shared folder containing shortcuts to images for quick display during conferences on the deskt...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-007-9095-7

    authors: Abe K,Narata M,Tanaka I,Takahashi M,Igarashi A,Sasaki T,Matsuyama K,Tohi N,Kosuda S

    更新日期:2009-12-01 00:00:00

  • Segmentation by evolution for visualization of the lower extremity of the Visible Man.

    abstract::Medical image segmentation is the crucial process for three-dimensional (3D) modeling. Many studies have claimed to suggest more accurate ways of segmentation. However, such research seems to have the drawback that it works against the parsimony principle. These methods have to resegment the regions of interest (ROIs)...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03190342

    authors: Lee JW,Lee J,Kim D,Kim JH,Park KS,Kang HS

    更新日期:2001-06-01 00:00:00

  • Automated pediatric abdominal effective diameter measurements versus age-predicted body size for normalization of CT dose.

    abstract::There has been increasing interest in adjusting CT radiation dose data for patient body size. A method for automated computation of the abdominal effective diameter of a patient from a CT image has previously only been tested in adult patients. In this work, we tested the method on a set of 128 pediatric patients aged...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9623-6

    authors: Cheng PM,Vachon LA,Duddalwar VA

    更新日期:2013-12-01 00:00:00

  • Effect of viewing angle on luminance and contrast for a five-million-pixel monochrome display and a nine-million-pixel color liquid crystal display.

    abstract::Digital imaging systems used in radiology rely on electronic display devices to present images to human observers. Active-matrix liquid crystal displays (AMLCDs) continue to improve and are beginning to be considered for diagnostic image display. In spite of recent progress, AMLCDs are characterized by a change in lum...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-004-1021-7

    authors: Fifadara DH,Averbukh A,Channin DS,Badano A

    更新日期:2004-12-01 00:00:00