Development of a noise reduction filter algorithm for pediatric body images in multidetector CT.

Abstract:

:Recently, several types of post-processing image filter which was designed to reduce noise allowing a corresponding dose reduction in CT images have been proposed and these were reported to be useful for noise reduction of CT images of adult patients. However, these have not been reported on adaptation for pediatric patients. Because they are not very effective with small (<20 cm) display fields of view, they could not be used for pediatric (e.g., premature babies and infants) body CT images. In order to solve this restriction, we have developed a new noise reduction filter algorithm which can be applicable for pediatric body CT images. This algorithm is based on a three-dimensional post processing, in which output pixel values are calculated by multi-directional, one-dimensional median filters on original volumetric datasets. The processed directions were selected except in in-plane (axial plane) direction, and consequently the in-plane spatial resolution was not affected by the filter. Also, in other directions, the spatial resolutions including slice thickness were almost maintained due to a characteristic of non-linear filtering of the median filter. From the results of phantom studies, the proposed algorithm could reduce standard deviation values as a noise index by up to 30% without affecting the spatial resolution of all directions, and therefore, contrast-to-noise ratio was improved by up to 30%. This newly developed filter algorithm will be useful for the diagnosis and radiation dose reduction of pediatric body CT images.

journal_name

J Digit Imaging

authors

Nishimaru E,Ichikawa K,Okita I,Tomoshige Y,Kurokawa T,Nakamura Y,Suzuki M

doi

10.1007/s10278-009-9218-4

subject

Has Abstract

pub_date

2010-12-01 00:00:00

pages

806-18

issue

6

eissn

0897-1889

issn

1618-727X

journal_volume

23

pub_type

杂志文章
  • Efficacy of a checklist-style structured radiology reporting template in reducing resident misses on cervical spine computed tomography examinations.

    abstract::The increasing use of medical checklists to promote patient safety raises the question of their utility in diagnostic radiology. This study evaluates the efficacy of a checklist-style reporting template in reducing resident misses on cervical spine CT examinations. A checklist-style reporting template for cervical spi...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-014-9703-2

    authors: Lin E,Powell DK,Kagetsu NJ

    更新日期:2014-10-01 00:00:00

  • Prostate tissue texture feature extraction for suspicious regions identification on TRUS images.

    abstract::In this work, two different approaches are proposed for region of interest (ROI) segmentation using transrectal ultrasound (TRUS) images. The two methods aim to extract informative features that are able to characterize suspicious regions in the TRUS images. Both proposed methods are based on multi-resolution analysis...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-008-9124-1

    authors: Mohamed SS,Li J,Salama MM,Freeman G

    更新日期:2009-10-01 00:00:00

  • Displaying radiologic images on personal computers.

    abstract::This is the second article of our series for radiologists and imaging scientists on displaying, manipulating, and analyzing radiologic images on personal computers (PCs). The first article discussed the digital image data file, standard PC graphic file formats, and various methods for importing radiologic images into ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168488

    authors: Gillespy T 3rd,Rowberg AH

    更新日期:1993-08-01 00:00:00

  • Automated hands-free image manipulation and viewing: a useful macro feature that assists radiologists in the viewing of chest and extremity digital radiographs.

    abstract::The authors present an adaptation of the macro recording feature on the Siemens Magic View 1000 workstation, which, with the click of one button, launches a macro that performs 3 clinically useful image manipulations. Using a Magic View 1004 Siemens unix workstation, the following Macro sequence was programmed: (1) se...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-002-5078-x

    authors: Koenker RM,Grover SA

    更新日期:2002-01-01 00:00:00

  • Challenges associated with interfacing computed tomography to a picture archiving and communication system at the Baltimore Veterans Affairs Medical Center--a historical perspective.

    abstract::The interfacing of digital image acquisition modalities to the picture archiving and communication system (PACS) plays a major part in the conversion from a traditional film-based radiology practice to one that relies almost entirely on soft-copy reading. The Baltimore Veterans Affairs Medical Center (VAMC) is one of ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167632

    authors: Kuzmak PM,Reiner BI,Siegel EL,Severance SM,Dayhoff RE

    更新日期:2000-05-01 00:00:00

  • A mobile tele-radiology imaging system with JPEG2000 for an emergency care.

    abstract::The aim of this study was to design a tele-radiology imaging system for rapid emergency care via mobile networks and to assess the diagnostic feasibility of the Joint Photographic Experts Group 2000 (JPEG2000) radiological imaging using portable devices. Rapid patient information and image exchange is helpful to make ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-010-9335-0

    authors: Kim DK,Kim EY,Yang KH,Lee CK,Yoo SK

    更新日期:2011-08-01 00:00:00

  • Thresholding histogram equalization.

    abstract::The drawbacks of adaptive histogram equalization techniques are the loss of definition on the edges of the object and overenhancement of noise in the images. These drawbacks can be avoided if the noise is excluded in the equalization transformation function computation. A method has been developed to separate the hist...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-001-0103-z

    authors: Chuang KS,Chen S,Hwang IM

    更新日期:2001-12-01 00:00:00

  • Detection of cancerous masses in mammograms by template matching: optimization of template brightness distribution by means of evolutionary algorithm.

    abstract::Optimization of brightness distribution in the template used for detection of cancerous masses in mammograms by means of correlation coefficient is presented. This optimization is performed by the evolutionary algorithm using an auxiliary mass classifier. Brightness along the radius of the circularly symmetric templat...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9402-1

    authors: Bator M,Nieniewski M

    更新日期:2012-02-01 00:00:00

  • Simulation of disaster recovery of a picture archiving and communications system using off-site hierarchal storage management.

    abstract::The purpose of this communication is to report on the testing of the disaster recovery capability of our hierarchical storage management (HSM) system. Disaster recovery implementation is a requirement of every mission-critical information technology project. Picture archiving and communications systems (PACS) certainl...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167652

    authors: Avrin DE,Andriole KP,Yin L,Gould R,Arenson RL

    更新日期:2000-05-01 00:00:00

  • Use of a thin-section archive and enterprise 3D software for long-term storage of thin-slice CT data sets.

    abstract::Rapid advances are changing the technology and applications of multidetector computed tomography (CT) scanners. The major increase in data associated with this new technology, however, breaks most commercial picture archiving and communication system (PACS) architectures by preventing them from delivering data in real...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-0925-9

    authors: Meenan C,Daly B,Toland C,Nagy P

    更新日期:2006-01-01 00:00:00

  • INDIAM--an e-learning system for the interpretation of mammograms.

    abstract::We propose the design of a teaching system named Interpretation and Diagnosis of Mammograms (INDIAM) for training students in the interpretation of mammograms and diagnosis of breast cancer. The proposed system integrates an illustrated tutorial on radiology of the breast, that is, mammography, which uses education te...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-008-9111-6

    authors: Guliato D,Bôaventura RS,Maia MA,Rangayyan RM,Simedo MS,Macedo TA

    更新日期:2009-08-01 00:00:00

  • App Review Series: CTisus iPearls.

    abstract::Thousands of "pearls" or facts related to radiology or imaging are accessible through a categorically organized user interface. Pearls are divided up into anatomical regions, as well as non-organ-specific categories. Information is easily accessible with an ad-free interface matched with full offline capability. User ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-018-0103-x

    authors: Buro J

    更新日期:2018-12-01 00:00:00

  • Computer-aided diagnosis for detection of lacunar infarcts on MR images: ROC analysis of radiologists' performance.

    abstract::The purpose of this study was to retrospectively evaluate radiologist performance in detection of lacunar infarcts on T1- and T2-weighted images, without and with the use of a computer-aided diagnosis (CAD) scheme. Thirty T1-weighted and 30 T2-weighted MR images obtained from 30 patients were used for assessing observ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9444-4

    authors: Uchiyama Y,Asano T,Kato H,Hara T,Kanematsu M,Hoshi H,Iwama T,Fujita H

    更新日期:2012-08-01 00:00:00

  • Contrast information of digital imaging in laser film digitizer and display monitor.

    abstract::A 10-bit or 12-bit gray scale is provided in commercial laser film digitizers. The true contrast resolution on the digitized image within a laser spot area of 200 microns in diameter is limited by both the quantum mottle and instrumentation noise. In this report, we investigated the mean value, standard deviation, and...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03170571

    authors: Lo SC,Gaskill JW,Mun SK,Krasner BH

    更新日期:1990-05-01 00:00:00

  • Management of the picture archiving and communications system archive at Texas Children's Hospital.

    abstract::As hospitals convert from conventional film-based imaging to picture archival and communications systems (PACS), methods for managing an enormous library of images must change considerably. While most hospitals are required to retain general, nonmammographic, radiologic images for 7 years beyond the examination date, ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03190304

    authors: Blado ME

    更新日期:2001-06-01 00:00:00

  • Comparative performance analysis of state-of-the-art classification algorithms applied to lung tissue categorization.

    abstract::In this paper, we compare five common classifier families in their ability to categorize six lung tissue patterns in high-resolution computed tomography (HRCT) images of patients affected with interstitial lung diseases (ILD) and with healthy tissue. The evaluated classifiers are naive Bayes, k-nearest neighbor, J48 d...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-008-9158-4

    authors: Depeursinge A,Iavindrasana J,Hidki A,Cohen G,Geissbuhler A,Platon A,Poletti PA,Müller H

    更新日期:2010-02-01 00:00:00

  • Displaying radiologic images on personal computers: practical applications and uses.

    abstract::This is the fifth and final article in our series for radiologists and imaging scientists on displaying, manipulating, and analyzing radiologic images on personal computers (PCs). There are many methods of transferring radiologic images into a PC, including transfer over a network, transfer from an imaging modality st...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168502

    authors: Gillespy T 3rd,Richardson ML,Rowberg AH

    更新日期:1994-08-01 00:00:00

  • A study for watermark methods appropriate to medical images.

    abstract::The network system, including the picture archiving and communication system (PACS), is essential in hospital and medical imaging fields these days. Many medical images are accessed and processed on the web, as well as in PACS. Therefore, any possible accidents caused by the illegal modification of medical images must...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03190332

    authors: Cho Y,Ahn B,Kim JS,Kim IY,Kim SI

    更新日期:2001-06-01 00:00:00

  • Precise measurement of vertebral bone density using computed tomography without the use of an external reference phantom.

    abstract::Bone density measurement by quantitative computed tomography (QCT) commonly uses an external reference phantom to decrease scan-to-scan and scanner-to-scanner variability. However, the peripheral location of these phantoms and other phantom variables is also responsible for a measurable degradation in accuracy and pre...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168013

    authors: Boden SD,Goodenough DJ,Stockham CD,Jacobs E,Dina T,Allman RM

    更新日期:1989-02-01 00:00:00

  • Point of Care Image Capture with a Custom Smartphone Application: Experience with an Encounter-Based Workflow.

    abstract::Medical documentation is one of the primary methods by which physicians share clinical information and impressions over time with one another. As the adage says, "a picture is worth a thousand words," and physicians have started leveraging consumer mobile technology to share images with one another. However, image sha...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00231-1

    authors: Mechanic OJ,Kurtzman ND,Chiu DT,Nathanson LA,Berkowitz SJ

    更新日期:2020-02-01 00:00:00

  • Patient-specific three-dimensional composite bone models for teaching and operation planning.

    abstract:BACKGROUND:Orthopedic trauma care relies on two-dimensional radiograms both before and during the operation. Understanding the three-dimensional nature of complex fractures on plain radiograms is challenging. Modern fluoroscopes can acquire three-dimensional volume datasets even during an operation, but the device limi...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-007-9078-8

    authors: Matthews F,Messmer P,Raikov V,Wanner GA,Jacob AL,Regazzoni P,Egli A

    更新日期:2009-10-01 00:00:00

  • Financial assessment of a picture archiving and communication system implemented all at once.

    abstract::The objective of this study was to determine the differential cost between film-based radiology and a hospital-wide picture archiving and communication system (PACS) implemented all at once. The cash flow and running costs of PACS and film-based operation were measured over an 8-year time horizon. When the hospital-wi...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-0632-6

    authors: Fang YC,Yang MC,Hsueh YS

    更新日期:2006-01-01 00:00:00

  • Automatically correlating clinical findings and body locations in radiology reports using MedLEE.

    abstract::In this paper, we describe and evaluate a system that extracts clinical findings and body locations from radiology reports and correlates them. The system uses Medical Language Extraction and Encoding System (MedLEE) to map the reports' free text to structured semantic representations of their content. A lightweight r...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9411-0

    authors: Sevenster M,van Ommering R,Qian Y

    更新日期:2012-04-01 00:00:00

  • Elastic registration of x-ray mammograms and three-dimensional magnetic resonance imaging data.

    abstract::Major problems in treating breast cancer are the early detection of tumors and accurate biopsy of small volumes of breast (mamma) tissue. This report presents an elastic registration algorithm of two x-ray mammograms and a corresponding magnetic resonance imaging (MRI) volume. To cope with the soft tissue deformation ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03190295

    authors: Ruiter NV,Müller TO,Stotzka R,Kaiser WA

    更新日期:2001-06-01 00:00:00

  • Clinical impact of picture archiving and communication systems: evaluation of a prototype system.

    abstract::Opinion surveys were gathered before and 6 months after installation of a prototype picture archiving and communication system (PACS) (PACS/1, Siemens Medical Systems, Iselin, NJ). Median turnaround times and the percent of delayed or missing reports were calculated for 1,026 baseline and 8,438 follow-up studies at 6 ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167836

    authors: Worrell JA,Federspiel CF,Creasy JL,Pickens DR 3rd,Higginbotham K,Patton JA,Partain CL

    更新日期:1992-05-01 00:00:00

  • Can paper replace laser film to communicate the results of wrist radiographs in trauma cases? A reproducibility study of the reading of wrist trauma case radiographs on a PACS workstation, laser film, and paper.

    abstract::The main goal of this study was to determine the reproducibility of the reading of wrist trauma case radiographs using three different media: laser film, a picture archiving and communication systems (PACS) workstation, and paper with an optimized layout. The study was conducted retrospectively in 200 consecutive pati...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9613-8

    authors: Teixeira P,Zabel JP,Baumann C,Albizzati S,Coudane H,Winninger D,Blum A

    更新日期:2013-12-01 00:00:00

  • User and system interface issues in the purchase of imaging and information systems.

    abstract::We introduce a set of worksheets to facilitate standardized comparisons among scheduling systems, hospital information systems, radiology information systems, and picture archiving and communication systems vendors. For each system category, we provide worksheets to evaluate the features, performance, installation req...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168605

    authors: Langer S,Wang J

    更新日期:1996-08-01 00:00:00

  • A content-boosted collaborative filtering algorithm for personalized training in interpretation of radiological imaging.

    abstract::Devising a method that can select cases based on the performance levels of trainees and the characteristics of cases is essential for developing a personalized training program in radiology education. In this paper, we propose a novel hybrid prediction algorithm called content-boosted collaborative filtering (CBCF) to...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-014-9678-z

    authors: Lin H,Yang X,Wang W

    更新日期:2014-08-01 00:00:00

  • MRI Radiomics for the Prediction of Fuhrman Grade in Clear Cell Renal Cell Carcinoma: a Machine Learning Exploratory Study.

    abstract::The Fuhrman nuclear grade is a recognized prognostic factor for patients with clear cell renal cell carcinoma (CCRCC) and its pre-treatment evaluation significantly affects decision-making in terms of management. In this study, we aimed to assess the feasibility of a combined approach of radiomics and machine learning...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-020-00336-y

    authors: Stanzione A,Ricciardi C,Cuocolo R,Romeo V,Petrone J,Sarnataro M,Mainenti PP,Improta G,De Rosa F,Insabato L,Brunetti A,Maurea S

    更新日期:2020-08-01 00:00:00

  • A Decision-Support Tool for Renal Mass Classification.

    abstract::We investigate the viability of statistical relational machine learning algorithms for the task of identifying malignancy of renal masses using radiomics-based imaging features. Features characterizing the texture, signal intensity, and other relevant metrics of the renal mass were extracted from multiphase contrast-e...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0100-0

    authors: Kunapuli G,Varghese BA,Ganapathy P,Desai B,Cen S,Aron M,Gill I,Duddalwar V

    更新日期:2018-12-01 00:00:00