Automated pediatric abdominal effective diameter measurements versus age-predicted body size for normalization of CT dose.

Abstract:

:There has been increasing interest in adjusting CT radiation dose data for patient body size. A method for automated computation of the abdominal effective diameter of a patient from a CT image has previously only been tested in adult patients. In this work, we tested the method on a set of 128 pediatric patients aged 0.8 to 12.9 years (average 8.0 years, SD = 3.7 years) who had CT abdomen/pelvis exams performed on a Toshiba Aquilion 64 scanner. For this set of patients, age-predicted abdominal effective diameter extrapolated based on data from the International Commission on Radiation Units and Measurements was a relatively poor predictor of measured effective diameter. The mean absolute percentage error between the CTDI normalization coefficient calculated from a manually measured effective diameter and the coefficient determined by age-predicted effective diameter was 12.3 % with respect to a 32 cm phantom (range 0.0-52.8 %, SD 8.7 %) and 12.9 % with respect to a 16 cm phantom (range 0.0-56.4 %, SD 9.2 %). In contrast, there is a close correspondence between the automated and manually measured patient effective diameters, with a mean absolute error of 0.6 cm (error range 0.2-1.3 cm). This correspondence translates into a high degree of correspondence between normalization coefficients determined by automated and manual measurements; the mean absolute percentage error was 2.1 % with respect to a 32 cm phantom (range 0.0-8.1 %, SD = 1.4 %) and 2.3 % with respect to a 16 cm phantom (range 0.0-9.3 %, SD = 1.6 %).

journal_name

J Digit Imaging

authors

Cheng PM,Vachon LA,Duddalwar VA

doi

10.1007/s10278-013-9623-6

subject

Has Abstract

pub_date

2013-12-01 00:00:00

pages

1151-5

issue

6

eissn

0897-1889

issn

1618-727X

journal_volume

26

pub_type

杂志文章
  • Point of Care Image Capture with a Custom Smartphone Application: Experience with an Encounter-Based Workflow.

    abstract::Medical documentation is one of the primary methods by which physicians share clinical information and impressions over time with one another. As the adage says, "a picture is worth a thousand words," and physicians have started leveraging consumer mobile technology to share images with one another. However, image sha...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00231-1

    authors: Mechanic OJ,Kurtzman ND,Chiu DT,Nathanson LA,Berkowitz SJ

    更新日期:2020-02-01 00:00:00

  • Can an Offsite Expert Remotely Evaluate the Visual Estimation of Ejection Fraction via a Social Network Video Call?

    abstract::We aimed to investigate whether an offsite expert could effectively evaluate visually estimated ejection fraction (EF) while watching and guiding the echocardiographic procedure of an onsite novice practitioner using a social network video call. Sixty patients presenting to the intensive care unit and requiring echoca...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-017-9974-5

    authors: Kim C,Hur J,Kang BS,Choi HJ,Shin JH,Kim TH,Chung JH

    更新日期:2017-12-01 00:00:00

  • A Web simulation of medical image reconstruction and processing as an educational tool.

    abstract::Web educational resources integrating interactive simulation tools provide students with an in-depth understanding of the medical imaging process. The aim of this work was the development of a purely Web-based, open access, interactive application, as an ancillary learning tool in graduate and postgraduate medical ima...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-014-9689-9

    authors: Papamichail D,Pantelis E,Papagiannis P,Karaiskos P,Georgiou E

    更新日期:2015-02-01 00:00:00

  • Solution for nonuniformities and spatial noise in medical LCD displays by using pixel-based correction.

    abstract::Liquid crystal displays (LCD) are rapidly replacing cathode ray tube displays (CRT) for medical imaging. LCD technology has improved significantly in the last few years and has important advantages over CRT. However, there are still some aspects of LCD that raise questions as to the usefulness of liquid crystal displa...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-005-2939-0

    authors: Kimpe T,Xthona A,Matthijs P,De Paepe L

    更新日期:2005-09-01 00:00:00

  • Detection of cancerous masses in mammograms by template matching: optimization of template brightness distribution by means of evolutionary algorithm.

    abstract::Optimization of brightness distribution in the template used for detection of cancerous masses in mammograms by means of correlation coefficient is presented. This optimization is performed by the evolutionary algorithm using an auxiliary mass classifier. Brightness along the radius of the circularly symmetric templat...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9402-1

    authors: Bator M,Nieniewski M

    更新日期:2012-02-01 00:00:00

  • Deep Convolutional Neural Networks for Endotracheal Tube Position and X-ray Image Classification: Challenges and Opportunities.

    abstract::The goal of this study is to evaluate the efficacy of deep convolutional neural networks (DCNNs) in differentiating subtle, intermediate, and more obvious image differences in radiography. Three different datasets were created, which included presence/absence of the endotracheal (ET) tube (n = 300), low/normal positio...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-017-9980-7

    authors: Lakhani P

    更新日期:2017-08-01 00:00:00

  • Hybrid Airway Segmentation Using Multi-Scale Tubular Structure Filters and Texture Analysis on 3D Chest CT Scans.

    abstract::Airway diseases are frequently related to morphological changes that may influence lung physiology. Accurate airway region segmentation may be useful for quantitative evaluation of disease prognosis and therapy efficacy. The information can also be applied to understand the fundamental mechanisms of various lung disea...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0158-8

    authors: Lee M,Lee JG,Kim N,Seo JB,Lee SM

    更新日期:2019-10-01 00:00:00

  • A perceptual evaluation of JPEG 2000 image compression for digital mammography: contrast-detail characteristics.

    abstract::In this investigation the effect of JPEG 2000 compression on the contrast-detail (CD) characteristics of digital mammography images was studied using an alternative forced choice (AFC) technique. Images of a contrast-detail phantom, acquired using a clinical full-field digital mammography system, were compressed using...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-003-1728-x

    authors: Suryanarayanan S,Karellas A,Vedantham S,Waldrop SM,D'Orsi CJ

    更新日期:2004-03-01 00:00:00

  • Network latency and operator performance in teleradiology applications.

    abstract::Teleradiology applications often use an interactive conferencing mode with remote control mouse pointers. When a telephone is used for voice communication, latencies of the data network can create a temporal discrepancy between the position of the mouse pointer and the verbal communication. To assess the effects of th...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168384

    authors: Stahl JN,Tellis W,Huang HK

    更新日期:2000-08-01 00:00:00

  • Classification of breast masses using selected shape, edge-sharpness, and texture features with linear and kernel-based classifiers.

    abstract::Breast masses due to benign disease and malignant tumors related to breast cancer differ in terms of shape, edge-sharpness, and texture characteristics. In this study, we evaluate a set of 22 features including 5 shape factors, 3 edge-sharpness measures, and 14 texture features computed from 111 regions in mammograms,...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-007-9102-z

    authors: Mu T,Nandi AK,Rangayyan RM

    更新日期:2008-06-01 00:00:00

  • Thresholding histogram equalization.

    abstract::The drawbacks of adaptive histogram equalization techniques are the loss of definition on the edges of the object and overenhancement of noise in the images. These drawbacks can be avoided if the noise is excluded in the equalization transformation function computation. A method has been developed to separate the hist...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-001-0103-z

    authors: Chuang KS,Chen S,Hwang IM

    更新日期:2001-12-01 00:00:00

  • User questionnaire to evaluate the radiological workspace.

    abstract::Over the past few years, an increase in digitalization of radiology departments can be seen, which has a large impact on the work of the radiologists. This impact is not only demonstrated by the increased use of digital images but also by changing demands on the whole reading environment. In this study, we evaluated t...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-0629-1

    authors: van Ooijen PM,Koesoema AP,Oudkerk M

    更新日期:2006-01-01 00:00:00

  • Elastic registration of x-ray mammograms and three-dimensional magnetic resonance imaging data.

    abstract::Major problems in treating breast cancer are the early detection of tumors and accurate biopsy of small volumes of breast (mamma) tissue. This report presents an elastic registration algorithm of two x-ray mammograms and a corresponding magnetic resonance imaging (MRI) volume. To cope with the soft tissue deformation ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03190295

    authors: Ruiter NV,Müller TO,Stotzka R,Kaiser WA

    更新日期:2001-06-01 00:00:00

  • Environmental designs for reading from imaging work stations: ergonomic and architectural features.

    abstract::Despite the rapid progress made in the electronic design of imaging work stations for medicine, much less effort has gone into the design of environments in which such systems will be used. Based on studies of radiologist film reading sessions, considerable time will be spent working at such viewing systems. If the ro...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168035

    authors: Horii SC,Horii HN,Mun SK,Benson HR,Zeman RK

    更新日期:1989-08-01 00:00:00

  • Automated routing of DICOM CT, MR, and CR images: solving the pitfalls of vendor-specific DICOM implementations.

    abstract::This paper details our experience in developing and implementing an automated DICOM Image Router. This workstation serves as a gateway between image acquisition devices and image display and storage devices. Images are checked for demographic input errors and data format inconsistencies between the source and destinat...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168283

    authors: Junck KL,McEachern M,Grandhi S,Lewey G

    更新日期:1998-08-01 00:00:00

  • White matter fiber tracking computation based on diffusion tensor imaging for clinical applications.

    abstract::Fiber tracking allows the in vivo reconstruction of human brain white matter fiber trajectories based on magnetic resonance diffusion tensor imaging (MR-DTI), but its application in the clinical routine is still in its infancy. In this study, we present a new software for fiber tracking, developed on top of a general-...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-0773-7

    authors: Dellani PR,Glaser M,Wille PR,Vucurevic G,Stadie A,Bauermann T,Tropine A,Perneczky A,von Wangenheim A,Stoeter P

    更新日期:2007-03-01 00:00:00

  • SCAR R&D Symposium 2003: comparing the efficacy of 5-MP CRT versus 3-MP LCD in the evaluation of interstitial lung disease.

    abstract::The efficacy of two medical-grade, self-calibrating, gray scale displays were compared with regard to impact on sensitivity and specificity for the detection of interstitial lung disease (ILD) on computed radiographs (CR). The displays were a 5-megapixel (MP) cathode ray tube (CRT) device and a 3-MP liquid crystal dis...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-004-1013-7

    authors: Langer S,Bartholmai B,Fetterly K,Harmsen S,Ryan W,Erickson B,Andriole K,Carrino J

    更新日期:2004-09-01 00:00:00

  • Automatically correlating clinical findings and body locations in radiology reports using MedLEE.

    abstract::In this paper, we describe and evaluate a system that extracts clinical findings and body locations from radiology reports and correlates them. The system uses Medical Language Extraction and Encoding System (MedLEE) to map the reports' free text to structured semantic representations of their content. A lightweight r...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9411-0

    authors: Sevenster M,van Ommering R,Qian Y

    更新日期:2012-04-01 00:00:00

  • Automated Facial Recognition of Computed Tomography-Derived Facial Images: Patient Privacy Implications.

    abstract::The recognizability of facial images extracted from publically available medical scans raises patient privacy concerns. This study examined how accurately facial images extracted from computed tomography (CT) scans are objectively matched with corresponding photographs of the scanned individuals. The test subjects wer...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-016-9932-7

    authors: Parks CL,Monson KL

    更新日期:2017-04-01 00:00:00

  • Increasing the number of gray shades in medical display systems--how much is enough?

    abstract::Medical images produced by x-ray detectors, computed tomography (CT) scanners, and other modalities typically contain between 12-16 bits/pixel, which corresponds to 4,096-65,536 shades of gray. On the other hand, we see that these images are visualized by means of medical displays that have much lower available number...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-1052-3

    authors: Kimpe T,Tuytschaever T

    更新日期:2007-12-01 00:00:00

  • Research and teaching access to a large clinical picture archiving and communication system.

    abstract:PURPOSE:To identify practical issues surrounding delivering digital images from picture archiving and communication systems (PACS) for research and teaching purposes. The complexity of Digital Imaging and Communications in Medicine (DICOM) access methods, security, patient confidentiality, PACS database integrity, port...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03190313

    authors: Harrison M,Koh J,Tran S,Mongkolwat P,Channin DS

    更新日期:2001-06-01 00:00:00

  • Anatomy of picture archiving and Communications systems: nuts and bolts--image acquisition: getting digital images from imaging modalities.

    abstract::Digital acquisition of data from the various imaging modalities for input to a picture archiving and communication system (PACS) is discussed. Essential features for successful clinical implementation including Digital Imaging and Communications in Medicine (DICOM) compliance, radiology information system (RIS)/hospit...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168809

    authors: Andriole KP

    更新日期:1999-05-01 00:00:00

  • Minimizing Digital Imaging and Communications in Medicine (DICOM) Modality Worklist patient/study selection errors.

    abstract::Frequently when patient and study identification information (patient name, patient identification, date of birth, sex, and accession number) are manually entered at a modality, typographical errors occur that have to be corrected before the acquired images can be matched to the proper patient and study on a picture a...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03190323

    authors: Kuzmak PM,Dayhoff RE

    更新日期:2001-06-01 00:00:00

  • Analysis of the X-ray work flow in two diagnostic imaging departments with and without a RIS/PACS system.

    abstract::A traditional radiological workflow is compared with one based on radiology information system/picture archiving and communication system (RIS/PACS). X-ray workflow process was considered in both radiology departments. First, the study identified the main phases of the research work as follows: Process Analysis, Data ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-0858-3

    authors: Mariani C,Tronchi A,Oncini L,Pirani O,Murri R

    更新日期:2006-01-01 00:00:00

  • The effect of lossy discrete cosine transform compression on subtle bone fractures.

    abstract::Extensive research efforts have been devoted to the feasibility of picture archiving and communication systems (PACS) in recent years. The advantages of PACS are numerous but mainly include reduced cost and improvement in the operational efficiency of a PACS-based radiology department. In digital radiography, images a...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168839

    authors: Toney MO,Dominguez R,Dao HN,Simmons G

    更新日期:1997-11-01 00:00:00

  • Clinical evaluation of irreversible data compression for computed radiography of the chest.

    abstract::Efficient data compression is essential for practical daily operation of computed radiography (CR) systems. In this study the clinical applicability of type III irreversible high data compression using an FCR 9501 chest unit (Fuji Photo Film, Tokyo, Japan) was evaluated. Sixty-eight normal and 93 various abnormal case...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03178080

    authors: Egashira K,Nakata H,Watanabe H,Uchida K,Nakamura K,Ishino Y,Horino K,Yoshikawa R

    更新日期:1998-11-01 00:00:00

  • Local and Non-local Regularization Techniques in Emission (PET/SPECT) Tomographic Image Reconstruction Methods.

    abstract::Emission tomographic image reconstruction is an ill-posed problem due to limited and noisy data and various image-degrading effects affecting the data and leads to noisy reconstructions. Explicit regularization, through iterative reconstruction methods, is considered better to compensate for reconstruction-based noise...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-015-9853-x

    authors: Ahmad M,Shahzad T,Masood K,Rashid K,Tanveer M,Iqbal R,Hussain N,Shahid A,Fazal-E-Aleem

    更新日期:2016-06-01 00:00:00

  • Simulation of disaster recovery of a picture archiving and communications system using off-site hierarchal storage management.

    abstract::The purpose of this communication is to report on the testing of the disaster recovery capability of our hierarchical storage management (HSM) system. Disaster recovery implementation is a requirement of every mission-critical information technology project. Picture archiving and communications systems (PACS) certainl...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167652

    authors: Avrin DE,Andriole KP,Yin L,Gould R,Arenson RL

    更新日期:2000-05-01 00:00:00

  • Strategic thinking for radiology.

    abstract::We have now analyzed the use and benefits of four Strategic Thinking Tools for Radiology: the Vision Statement, the High Five, the Two-by-Two, and Real-Win-Worth. Additional tools will be provided during the tutorial. The tools provided above should be considered as examples. They all contain the 10 benefits outlined ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168638

    authors: Schilling RB

    更新日期:1997-08-01 00:00:00

  • Extraction of microcalcifications in digital mammograms using regional watershed.

    abstract::In this report, a novel technique is proposed for computer-aided automatic extraction of microcalcifications in a digital mammogram. First, the microcalcifications are detected by morphological filtering, followed by entropy-based thresholding. Next, the microcalcifications are segmented by computing regional watershe...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167642

    authors: Bhajammanavar VM,Keong KC,Krishnan SM

    更新日期:2000-05-01 00:00:00