Increasing the number of gray shades in medical display systems--how much is enough?

Abstract:

:Medical images produced by x-ray detectors, computed tomography (CT) scanners, and other modalities typically contain between 12-16 bits/pixel, which corresponds to 4,096-65,536 shades of gray. On the other hand, we see that these images are visualized by means of medical displays that have much lower available number of gray shades. For a long time medical LCDs only supported 8 bits or 256 shades of gray per pixel. With the introduction of medical displays optimized for mammography, the available number of gray scales increased to 1,024. Recently, several manufacturers announced new display systems with higher bit depth. Because higher bit depth often directly results in higher display cost, it is a logical question to ask if this is required or even useful at all. This paper will give an answer by investigating several aspects such as limitations of the human visual system, digital imaging and communication in medicine grayscale standard display function calibration, and characteristics of medical LCDs.

journal_name

J Digit Imaging

authors

Kimpe T,Tuytschaever T

doi

10.1007/s10278-006-1052-3

subject

Has Abstract

pub_date

2007-12-01 00:00:00

pages

422-32

issue

4

eissn

0897-1889

issn

1618-727X

journal_volume

20

pub_type

杂志文章
  • Electronic imaging and clinical implementation: work group approach at Mayo Clinic, Rochester.

    abstract::Electronic imaging clinical implementation strategies and principles need to be developed as we move toward replacement of film-based radiology practices. During an 8-month period (1998 to 1999), an Electronic Imaging Clinical Implementation Work Group (EICIWG) was formed from sections of our department: Informatics L...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168749

    authors: King BF Jr,Erickson BJ,Williamson B Jr,Reading CC,James EM,Ramthun SK,Owen DA

    更新日期:1999-05-01 00:00:00

  • Local and Non-local Regularization Techniques in Emission (PET/SPECT) Tomographic Image Reconstruction Methods.

    abstract::Emission tomographic image reconstruction is an ill-posed problem due to limited and noisy data and various image-degrading effects affecting the data and leads to noisy reconstructions. Explicit regularization, through iterative reconstruction methods, is considered better to compensate for reconstruction-based noise...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-015-9853-x

    authors: Ahmad M,Shahzad T,Masood K,Rashid K,Tanveer M,Iqbal R,Hussain N,Shahid A,Fazal-E-Aleem

    更新日期:2016-06-01 00:00:00

  • Diagnosis of Autism Spectrum Disorders in Young Children Based on Resting-State Functional Magnetic Resonance Imaging Data Using Convolutional Neural Networks.

    abstract::Statistics show that the risk of autism spectrum disorder (ASD) is increasing in the world. Early diagnosis is most important factor in treatment of ASD. Thus far, the childhood diagnosis of ASD has been done based on clinical interviews and behavioral observations. There is a significant need to reduce the use of tra...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00196-1

    authors: Aghdam MA,Sharifi A,Pedram MM

    更新日期:2019-12-01 00:00:00

  • Thresholding histogram equalization.

    abstract::The drawbacks of adaptive histogram equalization techniques are the loss of definition on the edges of the object and overenhancement of noise in the images. These drawbacks can be avoided if the noise is excluded in the equalization transformation function computation. A method has been developed to separate the hist...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-001-0103-z

    authors: Chuang KS,Chen S,Hwang IM

    更新日期:2001-12-01 00:00:00

  • Feature-Motivated Simplified Adaptive PCNN-Based Medical Image Fusion Algorithm in NSST Domain.

    abstract::Multimodality medical image fusion plays a vital role in diagnosis, treatment planning, and follow-up studies of various diseases. It provides a composite image containing critical information of source images required for better localization and definition of different organs and lesions. In the state-of-the-art imag...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-015-9806-4

    authors: Ganasala P,Kumar V

    更新日期:2016-02-01 00:00:00

  • Should radiology IT be owned by the chief information officer?

    abstract::Considerable debate within the medical community has focused on the optimal location of information technology (IT) support groups on the organizational chart. The challenge has been to marry local accountability and physician acceptance of IT with the benefits gained by the economies of scale achieved by centralized ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-009-9196-6

    authors: Channin DS,Bowers G,Nagy P

    更新日期:2009-06-01 00:00:00

  • A Decision-Support Tool for Renal Mass Classification.

    abstract::We investigate the viability of statistical relational machine learning algorithms for the task of identifying malignancy of renal masses using radiomics-based imaging features. Features characterizing the texture, signal intensity, and other relevant metrics of the renal mass were extracted from multiphase contrast-e...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0100-0

    authors: Kunapuli G,Varghese BA,Ganapathy P,Desai B,Cen S,Aron M,Gill I,Duddalwar V

    更新日期:2018-12-01 00:00:00

  • Evaluation of irreversible JPEG compression for a clinical ultrasound practice.

    abstract::A prior ultrasound study indicated that images with low to moderate levels of JPEG and wavelet compression were acceptable for diagnostic purposes. The purpose of this study is to validate this prior finding using the Joint Photographic Experts Group (JPEG) baseline compression algorithm, at a compression ratio of app...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-002-0003-x

    authors: Persons KR,Hangiandreou NJ,Charboneau NT,Charboneau J,James E,Douglas BR,Salmon AP,Knudsen JM,Erickson BJ

    更新日期:2002-03-01 00:00:00

  • Prostate tissue texture feature extraction for suspicious regions identification on TRUS images.

    abstract::In this work, two different approaches are proposed for region of interest (ROI) segmentation using transrectal ultrasound (TRUS) images. The two methods aim to extract informative features that are able to characterize suspicious regions in the TRUS images. Both proposed methods are based on multi-resolution analysis...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-008-9124-1

    authors: Mohamed SS,Li J,Salama MM,Freeman G

    更新日期:2009-10-01 00:00:00

  • Estimation of Radiation Dose in CT Based on Projection Data.

    abstract::Managing and optimizing radiation dose has become a core problem for the CT community. As a fundamental step for dose optimization, accurate and computationally efficient dose estimates are crucial. The purpose of this study was to devise a computationally efficient projection-based dose metric. The absorbed energy an...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-016-9869-x

    authors: Tian X,Yin Z,De Man B,Samei E

    更新日期:2016-10-01 00:00:00

  • Expanding the functionality of speech recognition in radiology: creating a real-time methodology for measurement and analysis of occupational stress and fatigue.

    abstract::While occupational stress and fatigue have been well described throughout medicine, the radiology community is particularly susceptible due to declining reimbursements, heightened demands for service deliverables, and increasing exam volume and complexity. The resulting occupational stress can be variable in nature an...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9540-0

    authors: Reiner BI

    更新日期:2013-02-01 00:00:00

  • Environmental designs for reading from imaging work stations: ergonomic and architectural features.

    abstract::Despite the rapid progress made in the electronic design of imaging work stations for medicine, much less effort has gone into the design of environments in which such systems will be used. Based on studies of radiologist film reading sessions, considerable time will be spent working at such viewing systems. If the ro...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168035

    authors: Horii SC,Horii HN,Mun SK,Benson HR,Zeman RK

    更新日期:1989-08-01 00:00:00

  • Adding a microcomputer bar-code network to a minicomputer-based radiology information system.

    abstract::A bar-code terminal network under software control of a microcomputer was added to the minicomputer-based radiology information system at the Medical College of Georgia in Augusta. The bar-code network was specifically installed to address the inherent inaccuracies occurring when procedure information was entered at t...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168107

    authors: David G,Gregory S

    更新日期:1990-02-01 00:00:00

  • Strategic thinking for radiology.

    abstract::We have now analyzed the use and benefits of four Strategic Thinking Tools for Radiology: the Vision Statement, the High Five, the Two-by-Two, and Real-Win-Worth. Additional tools will be provided during the tutorial. The tools provided above should be considered as examples. They all contain the 10 benefits outlined ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168638

    authors: Schilling RB

    更新日期:1997-08-01 00:00:00

  • Precise measurement of vertebral bone density using computed tomography without the use of an external reference phantom.

    abstract::Bone density measurement by quantitative computed tomography (QCT) commonly uses an external reference phantom to decrease scan-to-scan and scanner-to-scanner variability. However, the peripheral location of these phantoms and other phantom variables is also responsible for a measurable degradation in accuracy and pre...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168013

    authors: Boden SD,Goodenough DJ,Stockham CD,Jacobs E,Dina T,Allman RM

    更新日期:1989-02-01 00:00:00

  • Can paper replace laser film to communicate the results of wrist radiographs in trauma cases? A reproducibility study of the reading of wrist trauma case radiographs on a PACS workstation, laser film, and paper.

    abstract::The main goal of this study was to determine the reproducibility of the reading of wrist trauma case radiographs using three different media: laser film, a picture archiving and communication systems (PACS) workstation, and paper with an optimized layout. The study was conducted retrospectively in 200 consecutive pati...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9613-8

    authors: Teixeira P,Zabel JP,Baumann C,Albizzati S,Coudane H,Winninger D,Blum A

    更新日期:2013-12-01 00:00:00

  • Detection of breast cancer with a computer-aided detection applied to full-field digital mammography.

    abstract::A study was conducted to evaluate the sensitivity of computer-aided detection (CAD) with full-field digital mammography in detection of breast cancer, based on mammographic appearance and histopathology. Retrospectively, CAD sensitivity was assessed in total group of 152 cases for subgroups based on breast density, ma...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9564-5

    authors: Murakami R,Kumita S,Tani H,Yoshida T,Sugizaki K,Kuwako T,Kiriyama T,Hakozaki K,Okazaki E,Yanagihara K,Iida S,Haga S,Tsuchiya S

    更新日期:2013-08-01 00:00:00

  • Automated pediatric abdominal effective diameter measurements versus age-predicted body size for normalization of CT dose.

    abstract::There has been increasing interest in adjusting CT radiation dose data for patient body size. A method for automated computation of the abdominal effective diameter of a patient from a CT image has previously only been tested in adult patients. In this work, we tested the method on a set of 128 pediatric patients aged...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9623-6

    authors: Cheng PM,Vachon LA,Duddalwar VA

    更新日期:2013-12-01 00:00:00

  • MABAL: a Novel Deep-Learning Architecture for Machine-Assisted Bone Age Labeling.

    abstract::Bone age assessment (BAA) is a commonly performed diagnostic study in pediatric radiology to assess skeletal maturity. The most commonly utilized method for assessment of BAA is the Greulich and Pyle method (Pediatr Radiol 46.9:1269-1274, 2016; Arch Dis Child 81.2:172-173, 1999) atlas. The evaluation of BAA can be a t...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0053-3

    authors: Mutasa S,Chang PD,Ruzal-Shapiro C,Ayyala R

    更新日期:2018-08-01 00:00:00

  • PDA-phone-based instant transmission of radiological images over a CDMA network by combining the PACS screen with a Bluetooth-interfaced local wireless link.

    abstract::Remote teleconsultation by specialists is important for timely, correct, and specialized emergency surgical and medical decision making. In this paper, we designed a new personal digital assistant (PDA)-phone-based emergency teleradiology system by combining cellular communication with Bluetooth-interfaced local wirel...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-007-9002-2

    authors: Kim DK,Yoo SK,Park JJ,Kim SH

    更新日期:2007-06-01 00:00:00

  • Solution for nonuniformities and spatial noise in medical LCD displays by using pixel-based correction.

    abstract::Liquid crystal displays (LCD) are rapidly replacing cathode ray tube displays (CRT) for medical imaging. LCD technology has improved significantly in the last few years and has important advantages over CRT. However, there are still some aspects of LCD that raise questions as to the usefulness of liquid crystal displa...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-005-2939-0

    authors: Kimpe T,Xthona A,Matthijs P,De Paepe L

    更新日期:2005-09-01 00:00:00

  • A breast density index for digital mammograms based on radiologists' ranking.

    abstract::The purpose of this study was to develop and evaluate a computerized method of calculating a breast density index (BDI) from digitized mammograms that was designed specifically to model radiologists' perception of breast density. A set of 153 pairs of digitized mammograms (cranio-caudal, CC, and mediolateral oblique, ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168733

    authors: Boone JM,Lindfors KK,Beatty CS,Seibert JA

    更新日期:1998-08-01 00:00:00

  • Full-Dose PET Image Estimation from Low-Dose PET Image Using Deep Learning: a Pilot Study.

    abstract::Positron emission tomography (PET) imaging is an effective tool used in determining disease stage and lesion malignancy; however, radiation exposure to patients and technicians during PET scans continues to draw concern. One way to minimize radiation exposure is to reduce the dose of radioactive tracer administered in...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0150-3

    authors: Kaplan S,Zhu YM

    更新日期:2019-10-01 00:00:00

  • Large-Scale Assessment of Scan-Time Variability and Multiple-Procedure Efficiency for Cross-Sectional Neuroradiological Exams in Clinical Practice.

    abstract::Scheduling of CT and MR exams requires reasonable estimates for expected scan duration. However, scan-time variability and efficiency gains from combining multiple exams are not quantitatively well characterized. In this work, we developed an informatics approach to quantify typical duration, duration variability, and...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00252-w

    authors: Zhang R,Narra VR,Kansagra AP

    更新日期:2020-02-01 00:00:00

  • Demonstration of digital radiographs by means of ink jet-printed paper copies: pilot study.

    abstract::Different digital medical images have been printed on paper with a continuous ink jet printer, and the quality has been evaluated. The emphasis has been on digital chest radiographs from a computed radiography system. The ink jet printing technique is described as well as the handling of the image data from image sour...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167806

    authors: Kirkhorn T,Kehler M,Nilsson J,Lyttkens K,Andersson B,Holmer NG

    更新日期:1992-11-01 00:00:00

  • A new family of distance functions for perceptual similarity retrieval of medical images.

    abstract::A long-standing challenge of content-based image retrieval (CBIR) systems is the definition of a suitable distance function to measure the similarity between images in an application context which complies with the human perception of similarity. In this paper, we present a new family of distance functions, called att...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-007-9084-x

    authors: Felipe JC,Traina C Jr,Traina AJ

    更新日期:2009-04-01 00:00:00

  • Displaying radiologic images on personal computers: practical applications and uses.

    abstract::This is the fifth and final article in our series for radiologists and imaging scientists on displaying, manipulating, and analyzing radiologic images on personal computers (PCs). There are many methods of transferring radiologic images into a PC, including transfer over a network, transfer from an imaging modality st...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168502

    authors: Gillespy T 3rd,Richardson ML,Rowberg AH

    更新日期:1994-08-01 00:00:00

  • The effects of ambient lighting in chest radiology reading rooms.

    abstract::Under typical dark chest radiography reading room conditions, a radiologist's pupils contract and dilate as their visual focus intermittently shifts between the high luminance monitor and the darker background wall, resulting in increased visual fatigue and degradation of diagnostic performance. A controlled increase ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9459-5

    authors: Pollard BJ,Samei E,Chawla AS,Beam C,Heyneman LE,Koweek LM,Martinez-Jimenez S,Washington L,Hashimoto N,McAdams HP

    更新日期:2012-08-01 00:00:00

  • Estimates of Patient Radiation Doses in Digital Radiography Using DICOM Information at a Large Teaching Hospital in Oman.

    abstract::In this study, we sought to estimate the patient radiation doses in the digital radiography X-ray examinations conducted in a large hospital. The patient exposure factors and kerma-area product (PKA) were retrospectively recorded via the Digital Imaging and Communications in Medicine (DICOM) header for 547 patients. T...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00199-y

    authors: Suliman II

    更新日期:2020-02-01 00:00:00

  • Applying Modern Virtual and Augmented Reality Technologies to Medical Images and Models.

    abstract::Recent technological innovations have created new opportunities for the increased adoption of virtual reality (VR) and augmented reality (AR) applications in medicine. While medical applications of VR have historically seen greater adoption from patient-as-user applications, the new era of VR/AR technology has created...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-018-0122-7

    authors: Sutherland J,Belec J,Sheikh A,Chepelev L,Althobaity W,Chow BJW,Mitsouras D,Christensen A,Rybicki FJ,La Russa DJ

    更新日期:2019-02-01 00:00:00