Evaluation of irreversible JPEG compression for a clinical ultrasound practice.

Abstract:

:A prior ultrasound study indicated that images with low to moderate levels of JPEG and wavelet compression were acceptable for diagnostic purposes. The purpose of this study is to validate this prior finding using the Joint Photographic Experts Group (JPEG) baseline compression algorithm, at a compression ratio of approximately 10:1, on a sufficiently large number of grayscale and color ultrasound images to attain a statistically significant result. The practical goal of this study is to determine if it is feasible for radiologists to use irreversibly compressed images as an integral part of the day to day ultrasound practice (ie, perform primary diagnosis with, and store irreversibly compressed images in the ultrasound PACS archive). In this study, 5 Radiologists were asked to review 300 grayscale and color static ultrasound images selected from 4 major anatomic groups. Each image was compressed and decompressed using the JPEG baseline compression algorithm at a fixed quality factor resulting in an average compression ratio of approximately 9:1. The images were presented in pairs (original and compressed) in a blinded fashion on a PACS workstation in the ultrasound reading areas, and radiologists were asked to pick which image they preferred in terms of diagnostic utility and their degree of certainty (on a scale from 1 to 4). Of the 1499 total readings, 50.17% (95% confidence intervals at 47.6%, and 52.7%) indicated a preference for the original image in the pair, and 49.83% (95% confidence intervals at 47.3%, and 52.0%) indicated a preference for the compressed image. These findings led the authors to conclude that static color and gray-scale ultrasound images compressed with JPEG at approximately 9:1 are statistically indistinguishable from the originals for primary diagnostic purposes. Based on the authors laboratory experience with compression and the results of this and other prior studies, JPEG compression is now being applied to all ultrasound images in the authors' radiology practice before reading. No image quality-related issues have been encountered after 12 months of operation (approximately 48000 examinations).

journal_name

J Digit Imaging

authors

Persons KR,Hangiandreou NJ,Charboneau NT,Charboneau J,James E,Douglas BR,Salmon AP,Knudsen JM,Erickson BJ

doi

10.1007/s10278-002-0003-x

subject

Has Abstract

pub_date

2002-03-01 00:00:00

pages

15-21

issue

1

eissn

0897-1889

issn

1618-727X

journal_volume

15

pub_type

杂志文章
  • Simulation of disaster recovery of a picture archiving and communications system using off-site hierarchal storage management.

    abstract::The purpose of this communication is to report on the testing of the disaster recovery capability of our hierarchical storage management (HSM) system. Disaster recovery implementation is a requirement of every mission-critical information technology project. Picture archiving and communications systems (PACS) certainl...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167652

    authors: Avrin DE,Andriole KP,Yin L,Gould R,Arenson RL

    更新日期:2000-05-01 00:00:00

  • Contrast information of digital imaging in laser film digitizer and display monitor.

    abstract::A 10-bit or 12-bit gray scale is provided in commercial laser film digitizers. The true contrast resolution on the digitized image within a laser spot area of 200 microns in diameter is limited by both the quantum mottle and instrumentation noise. In this report, we investigated the mean value, standard deviation, and...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03170571

    authors: Lo SC,Gaskill JW,Mun SK,Krasner BH

    更新日期:1990-05-01 00:00:00

  • A comparison of hard and soft copies processed with linear conversion and nonlinear conversion of skeletal fractures--a preliminary study.

    abstract::To compare hard copies and soft copies processed with linear and nonlinear conversion of skeletal fractures, we performed a receiver-operating characteristics study of 25 digital radiographs. There was no statistical difference between hard copies with linear and nonlinear conversion. However, it may be difficult to d...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168067

    authors: Kaji T,Katayama M,Kosuda S,Kusano S

    更新日期:1995-02-01 00:00:00

  • The impact of networking on image acquisition system design.

    abstract::Widespread integration of networking technology will change the hospital imaging environment, making computational, archiving, and film production services available to network-connected modalities. This change will be reflected in the designs of the image acquisition modalities themselves. A view of the future is pre...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168154

    authors: Perry JH

    更新日期:1991-11-01 00:00:00

  • Filmless in New Jersey: the New Jersey Medical School PACS Project.

    abstract::Transitioning to a filmless department is no easy task, especially at a large academic medical center. At the University of Medicine and Dentistry of New Jersey-New Jersey Medical School, a phased modality integration schedule was implemented to allow the technical and clinical staff to gradually absorb all of the cha...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-002-5044-7

    authors: Hirschorn D,Eber C,Samuels P,Gujrathi S,Baker SR

    更新日期:2002-01-01 00:00:00

  • Estimation of Radiation Dose in CT Based on Projection Data.

    abstract::Managing and optimizing radiation dose has become a core problem for the CT community. As a fundamental step for dose optimization, accurate and computationally efficient dose estimates are crucial. The purpose of this study was to devise a computationally efficient projection-based dose metric. The absorbed energy an...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-016-9869-x

    authors: Tian X,Yin Z,De Man B,Samei E

    更新日期:2016-10-01 00:00:00

  • Clinical evaluation of irreversible data compression for computed radiography of the chest.

    abstract::Efficient data compression is essential for practical daily operation of computed radiography (CR) systems. In this study the clinical applicability of type III irreversible high data compression using an FCR 9501 chest unit (Fuji Photo Film, Tokyo, Japan) was evaluated. Sixty-eight normal and 93 various abnormal case...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03178080

    authors: Egashira K,Nakata H,Watanabe H,Uchida K,Nakamura K,Ishino Y,Horino K,Yoshikawa R

    更新日期:1998-11-01 00:00:00

  • Patient-specific three-dimensional composite bone models for teaching and operation planning.

    abstract:BACKGROUND:Orthopedic trauma care relies on two-dimensional radiograms both before and during the operation. Understanding the three-dimensional nature of complex fractures on plain radiograms is challenging. Modern fluoroscopes can acquire three-dimensional volume datasets even during an operation, but the device limi...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-007-9078-8

    authors: Matthews F,Messmer P,Raikov V,Wanner GA,Jacob AL,Regazzoni P,Egli A

    更新日期:2009-10-01 00:00:00

  • Efficacy of a checklist-style structured radiology reporting template in reducing resident misses on cervical spine computed tomography examinations.

    abstract::The increasing use of medical checklists to promote patient safety raises the question of their utility in diagnostic radiology. This study evaluates the efficacy of a checklist-style reporting template in reducing resident misses on cervical spine CT examinations. A checklist-style reporting template for cervical spi...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-014-9703-2

    authors: Lin E,Powell DK,Kagetsu NJ

    更新日期:2014-10-01 00:00:00

  • The normal mode analysis shape detection method for automated shape determination of lung nodules.

    abstract::Surface morphology and shape in general are important predictors for the behavior of solid-type lung nodules detected on CT. More broadly, shape analysis is useful in many areas of computer-aided diagnosis and essentially all scientific and engineering disciplines. Automated methods for shape detection have all previo...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-014-9732-x

    authors: Stember JN

    更新日期:2015-04-01 00:00:00

  • Precise measurement of vertebral bone density using computed tomography without the use of an external reference phantom.

    abstract::Bone density measurement by quantitative computed tomography (QCT) commonly uses an external reference phantom to decrease scan-to-scan and scanner-to-scanner variability. However, the peripheral location of these phantoms and other phantom variables is also responsible for a measurable degradation in accuracy and pre...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168013

    authors: Boden SD,Goodenough DJ,Stockham CD,Jacobs E,Dina T,Allman RM

    更新日期:1989-02-01 00:00:00

  • Assessing the accuracy factors in the determination of postoperative acetabular cup orientation using hybrid 2D-3D registration.

    abstract::Single standard anteroposterior radiograph-based methods for measuring cup orientation following total hip arthroplasty (THA) are subject to substantial errors if the individual pelvic orientation with respect to X-ray plate is not taken into consideration. Previously, we proposed to use a hybrid 2D-3D registration sc...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-009-9226-4

    authors: Zheng G

    更新日期:2010-12-01 00:00:00

  • Integrating patient digital photographs with medical imaging examinations.

    abstract::We introduce the concept, benefits, and general architecture for acquiring, storing, and displaying digital photographs along with medical imaging examinations. We also discuss a specific implementation built around an Android-based system for simultaneously acquiring digital photographs along with portable radiograph...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-013-9579-6

    authors: Ramamurthy S,Bhatti P,Arepalli CD,Salama M,Provenzale JM,Tridandapani S

    更新日期:2013-10-01 00:00:00

  • A perceptual evaluation of JPEG 2000 image compression for digital mammography: contrast-detail characteristics.

    abstract::In this investigation the effect of JPEG 2000 compression on the contrast-detail (CD) characteristics of digital mammography images was studied using an alternative forced choice (AFC) technique. Images of a contrast-detail phantom, acquired using a clinical full-field digital mammography system, were compressed using...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-003-1728-x

    authors: Suryanarayanan S,Karellas A,Vedantham S,Waldrop SM,D'Orsi CJ

    更新日期:2004-03-01 00:00:00

  • Medical image file formats.

    abstract::Image file format is often a confusing aspect for someone wishing to process medical images. This article presents a demystifying overview of the major file formats currently used in medical imaging: Analyze, Neuroimaging Informatics Technology Initiative (Nifti), Minc, and Digital Imaging and Communications in Medici...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-013-9657-9

    authors: Larobina M,Murino L

    更新日期:2014-04-01 00:00:00

  • White matter fiber tracking computation based on diffusion tensor imaging for clinical applications.

    abstract::Fiber tracking allows the in vivo reconstruction of human brain white matter fiber trajectories based on magnetic resonance diffusion tensor imaging (MR-DTI), but its application in the clinical routine is still in its infancy. In this study, we present a new software for fiber tracking, developed on top of a general-...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-0773-7

    authors: Dellani PR,Glaser M,Wille PR,Vucurevic G,Stadie A,Bauermann T,Tropine A,Perneczky A,von Wangenheim A,Stoeter P

    更新日期:2007-03-01 00:00:00

  • Toward Automatic Detection of Radiation-Induced Cerebral Microbleeds Using a 3D Deep Residual Network.

    abstract::Cerebral microbleeds, which are small focal hemorrhages in the brain that are prevalent in many diseases, are gaining increasing attention due to their potential as surrogate markers of disease burden, clinical outcomes, and delayed effects of therapy. Manual detection is laborious and automatic detection and labeling...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0146-z

    authors: Chen Y,Villanueva-Meyer JE,Morrison MA,Lupo JM

    更新日期:2019-10-01 00:00:00

  • Computer-aided detection of architectural distortion in prior mammograms of interval cancer.

    abstract::Architectural distortion is an important sign of breast cancer, but because of its subtlety, it is a common cause of false-negative findings on screening mammograms. This paper presents methods for the detection of architectural distortion in mammograms of interval cancer cases taken prior to the detection of breast c...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-009-9257-x

    authors: Rangayyan RM,Banik S,Desautels JE

    更新日期:2010-10-01 00:00:00

  • Sophisticated hospital information system/radiology information system/picture archiving and communications system (PACS) integration in a large-scale traumatology PACS.

    abstract::Picture archiving and communications system (PACS) in the context of an outpatient trauma care center asks for a high level of interaction between information systems to guarantee rapid image acquisition and distribution to the surgeon. During installation of the Innsbruck PACS, special aspects of traumatology had to ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168769

    authors: Peer S,Vogl R,Peer R,Jaschke W

    更新日期:1999-05-01 00:00:00

  • Incorporating out-patient data from CD-R into the local PACS using DICOM worklist features.

    abstract::With the introduction of digital imaging in radiology, CD-Rs are increasingly used to distribute patient materials. This study investigates the application of a new software package and work protocol to integrate out-hospital data into the local PACS (picture archive and communication system) archive, which is hampere...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-005-5158-9

    authors: van Ooijen PM,Guignot J,Mevel G,Oudkerk M

    更新日期:2005-09-01 00:00:00

  • Financial assessment of a picture archiving and communication system implemented all at once.

    abstract::The objective of this study was to determine the differential cost between film-based radiology and a hospital-wide picture archiving and communication system (PACS) implemented all at once. The cash flow and running costs of PACS and film-based operation were measured over an 8-year time horizon. When the hospital-wi...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-0632-6

    authors: Fang YC,Yang MC,Hsueh YS

    更新日期:2006-01-01 00:00:00

  • Freehand liver volumetry by using an electromagnetic pen tablet: accuracy, precision, and rapidity.

    abstract::The purpose of this study is to assess the accuracy, precision, and rapidity of liver volumes calculated by using a freehand electromagnetic pen tablet contourtracing method as compared with the volumes calculated by using the standard optical mouse contourtracing method. The imaging data used as input for accuracy an...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-010-9291-8

    authors: Perandini S,Faccioli N,Inama M,Pozzi Mucelli R

    更新日期:2011-04-01 00:00:00

  • Development of a noise reduction filter algorithm for pediatric body images in multidetector CT.

    abstract::Recently, several types of post-processing image filter which was designed to reduce noise allowing a corresponding dose reduction in CT images have been proposed and these were reported to be useful for noise reduction of CT images of adult patients. However, these have not been reported on adaptation for pediatric p...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-009-9218-4

    authors: Nishimaru E,Ichikawa K,Okita I,Tomoshige Y,Kurokawa T,Nakamura Y,Suzuki M

    更新日期:2010-12-01 00:00:00

  • Management of the picture archiving and communications system archive at Texas Children's Hospital.

    abstract::As hospitals convert from conventional film-based imaging to picture archival and communications systems (PACS), methods for managing an enormous library of images must change considerably. While most hospitals are required to retain general, nonmammographic, radiologic images for 7 years beyond the examination date, ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03190304

    authors: Blado ME

    更新日期:2001-06-01 00:00:00

  • A computerized analysis system in chest radiography: evaluation of interstitial lung abnormalities.

    abstract::We evaluated the usefulness of a computerized analysis system in the detection of interstitial lung abnormalities in digitized chest radiography. This system uses the processes of four-directional Laplacian-Gaussian filtering, linear opacity judgment, and linear opacity subtraction. For qualitative analysis, we employ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168557

    authors: Kido S,Ikezoe J,Tamura S,Nakamura H,Kuroda C

    更新日期:1997-05-01 00:00:00

  • Detection of breast cancer with a computer-aided detection applied to full-field digital mammography.

    abstract::A study was conducted to evaluate the sensitivity of computer-aided detection (CAD) with full-field digital mammography in detection of breast cancer, based on mammographic appearance and histopathology. Retrospectively, CAD sensitivity was assessed in total group of 152 cases for subgroups based on breast density, ma...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9564-5

    authors: Murakami R,Kumita S,Tani H,Yoshida T,Sugizaki K,Kuwako T,Kiriyama T,Hakozaki K,Okazaki E,Yanagihara K,Iida S,Haga S,Tsuchiya S

    更新日期:2013-08-01 00:00:00

  • Hybrid Airway Segmentation Using Multi-Scale Tubular Structure Filters and Texture Analysis on 3D Chest CT Scans.

    abstract::Airway diseases are frequently related to morphological changes that may influence lung physiology. Accurate airway region segmentation may be useful for quantitative evaluation of disease prognosis and therapy efficacy. The information can also be applied to understand the fundamental mechanisms of various lung disea...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0158-8

    authors: Lee M,Lee JG,Kim N,Seo JB,Lee SM

    更新日期:2019-10-01 00:00:00

  • Picture archiving and communication systems and related developments in Sweden.

    abstract::Large PACS (Picture Archiving and Communication Systems) installations do not yet exist in Sweden, but some hospitals have had experience with limited PACS activities. At present there are four mini PACS installations in radiology departments and about 12 teleradiology systems in use in Sweden. A couple of small Swedi...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168157

    authors: Olsson S

    更新日期:1991-08-01 00:00:00

  • Automated detection of z-axis coverage with abdomen-pelvis computed tomography examinations.

    abstract::Excessive cephalocaudal anatomic (Z-axis) coverage can lead to unnecessary radiation exposure to a patient. In this study, an automated computing model was developed for identifying instances of potentially excessive Z-axis coverage with abdomen-pelvis examinations. Eight patient and imaging attributes including patie...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-014-9743-7

    authors: Zhang M,Wellnitz C,Cui C,Pavlicek W,Wu T

    更新日期:2015-06-01 00:00:00

  • The effects of ambient lighting in chest radiology reading rooms.

    abstract::Under typical dark chest radiography reading room conditions, a radiologist's pupils contract and dilate as their visual focus intermittently shifts between the high luminance monitor and the darker background wall, resulting in increased visual fatigue and degradation of diagnostic performance. A controlled increase ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9459-5

    authors: Pollard BJ,Samei E,Chawla AS,Beam C,Heyneman LE,Koweek LM,Martinez-Jimenez S,Washington L,Hashimoto N,McAdams HP

    更新日期:2012-08-01 00:00:00