Detection of breast cancer with a computer-aided detection applied to full-field digital mammography.

Abstract:

:A study was conducted to evaluate the sensitivity of computer-aided detection (CAD) with full-field digital mammography in detection of breast cancer, based on mammographic appearance and histopathology. Retrospectively, CAD sensitivity was assessed in total group of 152 cases for subgroups based on breast density, mammographic presentation, lesion size, and results of histopathological examination. The overall sensitivity of CAD was 91 % (139 of 152 cases). CAD detected 100 % (47/47) of cancers manifested as microcalcifications; 98 % (62/63) of those manifested as non-calcified masses; 100 % (15/15) of those manifested as mixed masses and microcalcifications; 75 % (12/16) of those manifested as architectural distortions, and 69 % (18/26) of those manifested as focal asymmetry. CAD sensitivity was 83 % (10/12) for cancers measuring 1-10 mm, 92 % (37/40) for those measuring 11-20 mm, and 92 % (92/100) for those measuring >20 mm. There was no significant difference in CAD detection efficiency between cancers in dense breasts (88 %; 69/78) and those in non-dense breasts (95 %; 70/74). CAD showed a high sensitivity of 91 % (139/152) for the mammographic appearance of cancer and 100 % sensitivity for identifying cancers manifested as microcalcifications. Sensitivity was not influenced by breast density or lesion size. CAD should be effective for helping radiologists detect breast cancer at an earlier stage.

journal_name

J Digit Imaging

authors

Murakami R,Kumita S,Tani H,Yoshida T,Sugizaki K,Kuwako T,Kiriyama T,Hakozaki K,Okazaki E,Yanagihara K,Iida S,Haga S,Tsuchiya S

doi

10.1007/s10278-012-9564-5

subject

Has Abstract

pub_date

2013-08-01 00:00:00

pages

768-73

issue

4

eissn

0897-1889

issn

1618-727X

journal_volume

26

pub_type

杂志文章
  • Elastic registration of x-ray mammograms and three-dimensional magnetic resonance imaging data.

    abstract::Major problems in treating breast cancer are the early detection of tumors and accurate biopsy of small volumes of breast (mamma) tissue. This report presents an elastic registration algorithm of two x-ray mammograms and a corresponding magnetic resonance imaging (MRI) volume. To cope with the soft tissue deformation ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03190295

    authors: Ruiter NV,Müller TO,Stotzka R,Kaiser WA

    更新日期:2001-06-01 00:00:00

  • Programming in the small.

    abstract::Academic medical centers, in general, and radiation oncology research, in particular, rely heavily on custom software tools and applications. The code development is typically the responsibility of a single individual or at most a small team. Often these individuals are not professional programmers but physicists, stu...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-009-9271-z

    authors: Gersten DB,Langer SG

    更新日期:2011-02-01 00:00:00

  • A Decision-Support Tool for Renal Mass Classification.

    abstract::We investigate the viability of statistical relational machine learning algorithms for the task of identifying malignancy of renal masses using radiomics-based imaging features. Features characterizing the texture, signal intensity, and other relevant metrics of the renal mass were extracted from multiphase contrast-e...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0100-0

    authors: Kunapuli G,Varghese BA,Ganapathy P,Desai B,Cen S,Aron M,Gill I,Duddalwar V

    更新日期:2018-12-01 00:00:00

  • A study for watermark methods appropriate to medical images.

    abstract::The network system, including the picture archiving and communication system (PACS), is essential in hospital and medical imaging fields these days. Many medical images are accessed and processed on the web, as well as in PACS. Therefore, any possible accidents caused by the illegal modification of medical images must...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03190332

    authors: Cho Y,Ahn B,Kim JS,Kim IY,Kim SI

    更新日期:2001-06-01 00:00:00

  • Quantifying Analysis of Uncertainty in Medical Reporting: Creation of User and Context-Specific Uncertainty Profiles.

    abstract::While uncertainty is ubiquitous in medical practice, minimal work to date has been performed to analyze the cause and effect relationship between uncertainty and patient outcomes. In medical imaging practice, uncertainty in the radiology report has been well documented to be a source of clinician dissatisfaction. Befo...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-018-0057-z

    authors: Reiner BI

    更新日期:2018-08-01 00:00:00

  • The effects of ambient lighting in chest radiology reading rooms.

    abstract::Under typical dark chest radiography reading room conditions, a radiologist's pupils contract and dilate as their visual focus intermittently shifts between the high luminance monitor and the darker background wall, resulting in increased visual fatigue and degradation of diagnostic performance. A controlled increase ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9459-5

    authors: Pollard BJ,Samei E,Chawla AS,Beam C,Heyneman LE,Koweek LM,Martinez-Jimenez S,Washington L,Hashimoto N,McAdams HP

    更新日期:2012-08-01 00:00:00

  • Information retrieval for teaching files: a preliminary study.

    abstract::A computer algorithm for information retrieval from an electronic teaching file has been developed. This index enables the user to retrieve cases from a teaching file, based on the input of a combination of features. The algorithm is based on nearest neighbor analysis, and is programmed in the "C" language. A teaching...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167602

    authors: Bramble JM,Insana MF,Dwyer SJ 3rd

    更新日期:1990-08-01 00:00:00

  • Adding a microcomputer bar-code network to a minicomputer-based radiology information system.

    abstract::A bar-code terminal network under software control of a microcomputer was added to the minicomputer-based radiology information system at the Medical College of Georgia in Augusta. The bar-code network was specifically installed to address the inherent inaccuracies occurring when procedure information was entered at t...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168107

    authors: David G,Gregory S

    更新日期:1990-02-01 00:00:00

  • Computer-Aided Histopathological Image Analysis Techniques for Automated Nuclear Atypia Scoring of Breast Cancer: a Review.

    abstract::Breast cancer is the most common type of malignancy diagnosed in women. Through early detection and diagnosis, there is a great chance of recovery and thereby reduce the mortality rate. Many preliminary tests like non-invasive radiological diagnosis using ultrasound, mammography, and MRI are widely used for the diagno...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-019-00295-z

    authors: Das A,Nair MS,Peter SD

    更新日期:2020-10-01 00:00:00

  • Combining multi-scale feature fusion with multi-attribute grading, a CNN model for benign and malignant classification of pulmonary nodules.

    abstract::Lung cancer has the highest mortality rate of all cancers, and early detection can improve survival rates. In the recent years, low-dose CT has been widely used to detect lung cancer. However, the diagnosis is limited by the subjective experience of doctors. Therefore, the main purpose of this study is to use convolut...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-020-00333-1

    authors: Zhao J,Zhang C,Li D,Niu J

    更新日期:2020-08-01 00:00:00

  • Clinical evaluation of irreversible data compression for computed radiography of the chest.

    abstract::Efficient data compression is essential for practical daily operation of computed radiography (CR) systems. In this study the clinical applicability of type III irreversible high data compression using an FCR 9501 chest unit (Fuji Photo Film, Tokyo, Japan) was evaluated. Sixty-eight normal and 93 various abnormal case...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03178080

    authors: Egashira K,Nakata H,Watanabe H,Uchida K,Nakamura K,Ishino Y,Horino K,Yoshikawa R

    更新日期:1998-11-01 00:00:00

  • Artifacts found during quality assurance testing of computed radiography and digital radiography detectors.

    abstract::A series of artifact images, obtained over 5 years of performance testing, of both computed radiography (CR) and integrated digital radiographic X-ray imaging detectors are presented. The images presented are all either flat field or test object images and show artifacts previously either undescribed in the existing l...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-008-9109-0

    authors: Honey ID,Mackenzie A

    更新日期:2009-08-01 00:00:00

  • Ruler Based Automatic C-Arm Image Stitching Without Overlapping Constraint.

    abstract::In this paper, we propose a new method for stitching multiple fluoroscopic images taken by a C-arm instrument. We employ an X-ray radiolucent ruler with numbered graduations while acquiring the images, and the image stitching is based on detecting and matching ruler parts in the images to the corresponding parts of a ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-014-9763-3

    authors: Chen C,Kojcev R,Haschtmann D,Fekete T,Nolte L,Zheng G

    更新日期:2015-08-01 00:00:00

  • Endowing a Content-Based Medical Image Retrieval System with Perceptual Similarity Using Ensemble Strategy.

    abstract::Content-based medical image retrieval (CBMIR) is a powerful resource to improve differential computer-aided diagnosis. The major problem with CBMIR applications is the semantic gap, a situation in which the system does not follow the users' sense of similarity. This gap can be bridged by the adequate modeling of simil...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-015-9809-1

    authors: Bedo MV,Pereira Dos Santos D,Ponciano-Silva M,de Azevedo-Marques PM,Ferreira de Carvalho AP,Traina C Jr

    更新日期:2016-02-01 00:00:00

  • Detection of cancerous masses in mammograms by template matching: optimization of template brightness distribution by means of evolutionary algorithm.

    abstract::Optimization of brightness distribution in the template used for detection of cancerous masses in mammograms by means of correlation coefficient is presented. This optimization is performed by the evolutionary algorithm using an auxiliary mass classifier. Brightness along the radius of the circularly symmetric templat...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9402-1

    authors: Bator M,Nieniewski M

    更新日期:2012-02-01 00:00:00

  • Toward Data-Driven Radiology Education-Early Experience Building Multi-Institutional Academic Trainee Interpretation Log Database (MATILDA).

    abstract::The residency review committee of the Accreditation Council of Graduate Medical Education (ACGME) collects data on resident exam volume and sets minimum requirements. However, this data is not made readily available, and the ACGME does not share their tools or methodology. It is therefore difficult to assess the integ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s10278-016-9872-2

    authors: Chen PH,Loehfelm TW,Kamer AP,Lemmon AB,Cook TS,Kohli MD

    更新日期:2016-12-01 00:00:00

  • Designing better radiology workstations: impact of two user interfaces on interpretation errors and user satisfaction.

    abstract::This paper presents our solution for supporting radiologists' interpretation of digital images by automating image presentation during sequential interpretation steps. We extended current hanging protocols with support for "stages" which reflect the presentation of digital information required to complete a single ste...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-004-1906-5

    authors: Moise A,Atkins MS

    更新日期:2005-06-01 00:00:00

  • Estimates of Patient Radiation Doses in Digital Radiography Using DICOM Information at a Large Teaching Hospital in Oman.

    abstract::In this study, we sought to estimate the patient radiation doses in the digital radiography X-ray examinations conducted in a large hospital. The patient exposure factors and kerma-area product (PKA) were retrospectively recorded via the Digital Imaging and Communications in Medicine (DICOM) header for 547 patients. T...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00199-y

    authors: Suliman II

    更新日期:2020-02-01 00:00:00

  • Automated Facial Recognition of Computed Tomography-Derived Facial Images: Patient Privacy Implications.

    abstract::The recognizability of facial images extracted from publically available medical scans raises patient privacy concerns. This study examined how accurately facial images extracted from computed tomography (CT) scans are objectively matched with corresponding photographs of the scanned individuals. The test subjects wer...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-016-9932-7

    authors: Parks CL,Monson KL

    更新日期:2017-04-01 00:00:00

  • Integrating IT into the radiology environment.

    abstract::Rather than perpetuating the struggle, "who controls the PACS, Radiology or Information Technology (IT)," Community Hospital of the Monterey Peninsula (CHOMP) took the approach of incorporating IT support within the Radiology Department. CHOMP faced the challenge of staffing Radiology computer systems and networks by ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-002-5048-3

    authors: McDonald A

    更新日期:2002-01-01 00:00:00

  • Full-Dose PET Image Estimation from Low-Dose PET Image Using Deep Learning: a Pilot Study.

    abstract::Positron emission tomography (PET) imaging is an effective tool used in determining disease stage and lesion malignancy; however, radiation exposure to patients and technicians during PET scans continues to draw concern. One way to minimize radiation exposure is to reduce the dose of radioactive tracer administered in...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0150-3

    authors: Kaplan S,Zhu YM

    更新日期:2019-10-01 00:00:00

  • Enhancement of storage phosphor plate images: a C-language program.

    abstract::A C-language software program has been developed for emulating the image enhancement processing of a storage phosphor plate system. This software has been implemented on a VAX 3400 computer. There are 2,100 lines of C-language code in the program. There are seven parameters used to specify the degree of enhancement. T...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167825

    authors: Templeton AW,Wetzel LH,Cook LT,Harrison LA,Eckard DA,Anderson WH,Hensley KS

    更新日期:1992-02-01 00:00:00

  • Detection of microcalcifications by means of multiscale methods and statistical techniques.

    abstract::The detection of clustered microcalcifications can help the radiologist to detect early breast cancer. Microcalcifications exhibit some important characteristics, such as small size and high luminosity. Use of a computer-aided diagnosis (CAD) method can prevent them being overlooked. In this report, a multiresolution ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167672

    authors: Mata Campos R,Vidal EM,Nava E,Martínez-Morillo M,Sendra F

    更新日期:2000-05-01 00:00:00

  • PDA-phone-based instant transmission of radiological images over a CDMA network by combining the PACS screen with a Bluetooth-interfaced local wireless link.

    abstract::Remote teleconsultation by specialists is important for timely, correct, and specialized emergency surgical and medical decision making. In this paper, we designed a new personal digital assistant (PDA)-phone-based emergency teleradiology system by combining cellular communication with Bluetooth-interfaced local wirel...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-007-9002-2

    authors: Kim DK,Yoo SK,Park JJ,Kim SH

    更新日期:2007-06-01 00:00:00

  • MRI Radiomics for the Prediction of Fuhrman Grade in Clear Cell Renal Cell Carcinoma: a Machine Learning Exploratory Study.

    abstract::The Fuhrman nuclear grade is a recognized prognostic factor for patients with clear cell renal cell carcinoma (CCRCC) and its pre-treatment evaluation significantly affects decision-making in terms of management. In this study, we aimed to assess the feasibility of a combined approach of radiomics and machine learning...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-020-00336-y

    authors: Stanzione A,Ricciardi C,Cuocolo R,Romeo V,Petrone J,Sarnataro M,Mainenti PP,Improta G,De Rosa F,Insabato L,Brunetti A,Maurea S

    更新日期:2020-08-01 00:00:00

  • Impact of digital radiography on clinical workflow and patient satisfaction.

    abstract::Compared to traditional film radiography, digital radiography is believed to improve workflow and patient throughput. Digital radiography permits the technologist to immediately view the quality of the film directly at the modality. Additional workflow improvements, therefore, should be achieved with the integration o...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167662

    authors: Dackiewicz D,Bergsneider C,Piraino D

    更新日期:2000-05-01 00:00:00

  • Filmless in New Jersey: the New Jersey Medical School PACS Project.

    abstract::Transitioning to a filmless department is no easy task, especially at a large academic medical center. At the University of Medicine and Dentistry of New Jersey-New Jersey Medical School, a phased modality integration schedule was implemented to allow the technical and clinical staff to gradually absorb all of the cha...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-002-5044-7

    authors: Hirschorn D,Eber C,Samuels P,Gujrathi S,Baker SR

    更新日期:2002-01-01 00:00:00

  • Can the documented patient briefing be carried out with an iPad app?

    abstract::To evaluate the feasibility of an iPad-based documented patient briefing for Magnetic Resonance Imaging (MRI) examinations. A standard briefing sheet and questionnaire for a MRI scan was converted from paper form into an iPad application. Twenty patients, who had been referred for an MRI scan, were briefed about the e...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9560-9

    authors: Schlechtweg PM,Hammon M,Heberlein C,Giese D,Uder M,Schwab SA

    更新日期:2013-06-01 00:00:00

  • Volumetric Assessment of Pediatric Vascular Malformations Using a Rapid, Hand-Held Three-Dimensional Imaging System.

    abstract::The effect of percutaneous, surgical, and medical therapies for vascular malformations (VMs) is often difficult to quantify volumetrically using cross-sectional imaging. Volumetric measurement is often estimated with serial, expensive MRI examinations which may require sedation or anesthesia. We aim to explore whether...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00183-6

    authors: Speir EJ,Matthew Hawkins C,Weiler MJ,Briones M,Swerdlin R,Park S,Brandon Dixon J

    更新日期:2019-04-01 00:00:00

  • Automated routing of DICOM CT, MR, and CR images: solving the pitfalls of vendor-specific DICOM implementations.

    abstract::This paper details our experience in developing and implementing an automated DICOM Image Router. This workstation serves as a gateway between image acquisition devices and image display and storage devices. Images are checked for demographic input errors and data format inconsistencies between the source and destinat...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168283

    authors: Junck KL,McEachern M,Grandhi S,Lewey G

    更新日期:1998-08-01 00:00:00