A study for watermark methods appropriate to medical images.

Abstract:

:The network system, including the picture archiving and communication system (PACS), is essential in hospital and medical imaging fields these days. Many medical images are accessed and processed on the web, as well as in PACS. Therefore, any possible accidents caused by the illegal modification of medical images must be prevented. Digital image watermark techniques have been proposed as a method to protect against illegal copying or modification of copyrighted material. Invisible signatures made by a digital image watermarking technique can be a solution to these problems. However, medical images have some different characteristics from normal digital images in that one must not corrupt the information contained in the original medical images. In this study, we suggest modified watermark methods appropriate for medical image processing and communication system that prevent clinically important data contained in original images from being corrupted.

journal_name

J Digit Imaging

authors

Cho Y,Ahn B,Kim JS,Kim IY,Kim SI

doi

10.1007/BF03190332

subject

Has Abstract

pub_date

2001-06-01 00:00:00

pages

184-6

issue

2 Suppl 1

eissn

0897-1889

issn

1618-727X

journal_volume

14

pub_type

杂志文章
  • Effect of Interventional Program on the Utilization of PACS in Point-of-Care Ultrasound.

    abstract::While the implementation of Picture Archiving and Communication Systems (PACS) has revolutionized the field of radiology, there has been considerably less utilization of PACS by emergency physicians with point-of-care ultrasound. Benefits of PACS archival of images include improved quality assurance, preservation of i...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-016-9893-x

    authors: Kessler R,Stowell JR,Vogel JA,Liao MM,Kendall JL

    更新日期:2016-12-01 00:00:00

  • Electronic imaging and clinical implementation: work group approach at Mayo Clinic, Rochester.

    abstract::Electronic imaging clinical implementation strategies and principles need to be developed as we move toward replacement of film-based radiology practices. During an 8-month period (1998 to 1999), an Electronic Imaging Clinical Implementation Work Group (EICIWG) was formed from sections of our department: Informatics L...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168749

    authors: King BF Jr,Erickson BJ,Williamson B Jr,Reading CC,James EM,Ramthun SK,Owen DA

    更新日期:1999-05-01 00:00:00

  • Stereotactic neurosurgery planning on a personal-computer-based work station.

    abstract::Stereotactic surgery requires knowledge of cerebral structures derived from more than one image source. We have developed a PC-AT-based workstation that accepts patient images, made with the stereotactic frame in place, from CT, MRI, and DSA modalities. Reference markers on the frame are identified in the images to es...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168023

    authors: Peters TM,Clark JA,Pike GB,Henri C,Collins L,Leksell D,Jeppsson O

    更新日期:1989-05-01 00:00:00

  • Feature-Motivated Simplified Adaptive PCNN-Based Medical Image Fusion Algorithm in NSST Domain.

    abstract::Multimodality medical image fusion plays a vital role in diagnosis, treatment planning, and follow-up studies of various diseases. It provides a composite image containing critical information of source images required for better localization and definition of different organs and lesions. In the state-of-the-art imag...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-015-9806-4

    authors: Ganasala P,Kumar V

    更新日期:2016-02-01 00:00:00

  • Designing better radiology workstations: impact of two user interfaces on interpretation errors and user satisfaction.

    abstract::This paper presents our solution for supporting radiologists' interpretation of digital images by automating image presentation during sequential interpretation steps. We extended current hanging protocols with support for "stages" which reflect the presentation of digital information required to complete a single ste...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-004-1906-5

    authors: Moise A,Atkins MS

    更新日期:2005-06-01 00:00:00

  • Segmentation by evolution for visualization of the lower extremity of the Visible Man.

    abstract::Medical image segmentation is the crucial process for three-dimensional (3D) modeling. Many studies have claimed to suggest more accurate ways of segmentation. However, such research seems to have the drawback that it works against the parsimony principle. These methods have to resegment the regions of interest (ROIs)...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03190342

    authors: Lee JW,Lee J,Kim D,Kim JH,Park KS,Kang HS

    更新日期:2001-06-01 00:00:00

  • A breast density index for digital mammograms based on radiologists' ranking.

    abstract::The purpose of this study was to develop and evaluate a computerized method of calculating a breast density index (BDI) from digitized mammograms that was designed specifically to model radiologists' perception of breast density. A set of 153 pairs of digitized mammograms (cranio-caudal, CC, and mediolateral oblique, ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168733

    authors: Boone JM,Lindfors KK,Beatty CS,Seibert JA

    更新日期:1998-08-01 00:00:00

  • The effect of slice thickness on the assessment of bone defect volumes by the Cavalieri principle using cone beam computed tomography.

    abstract::The purpose of this study was to investigate the possible effects of section thickness on volume estimations obtained by cone beam computed tomography. Intraosseal cavities representing bone defects on vestibular sides of the two dry sheep mandibles were scanned by a cone beam computed tomography system. Consecutive s...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9480-8

    authors: Sezgin OS,Kayıpmaz S,Sahin B

    更新日期:2013-02-01 00:00:00

  • The impact of networking on image acquisition system design.

    abstract::Widespread integration of networking technology will change the hospital imaging environment, making computational, archiving, and film production services available to network-connected modalities. This change will be reflected in the designs of the image acquisition modalities themselves. A view of the future is pre...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168154

    authors: Perry JH

    更新日期:1991-11-01 00:00:00

  • A content-boosted collaborative filtering algorithm for personalized training in interpretation of radiological imaging.

    abstract::Devising a method that can select cases based on the performance levels of trainees and the characteristics of cases is essential for developing a personalized training program in radiology education. In this paper, we propose a novel hybrid prediction algorithm called content-boosted collaborative filtering (CBCF) to...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-014-9678-z

    authors: Lin H,Yang X,Wang W

    更新日期:2014-08-01 00:00:00

  • Medicolegal considerations in the implementation of a PACS web application.

    abstract::The goal of this study is to provide the clinical end users of an enterprisewide picture archiving and communication system/Web application with a thorough understanding of the application and education to maintain patient privacy and protection. ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-002-5101-2

    authors: Cook K

    更新日期:2002-01-01 00:00:00

  • MRI Radiomics for the Prediction of Fuhrman Grade in Clear Cell Renal Cell Carcinoma: a Machine Learning Exploratory Study.

    abstract::The Fuhrman nuclear grade is a recognized prognostic factor for patients with clear cell renal cell carcinoma (CCRCC) and its pre-treatment evaluation significantly affects decision-making in terms of management. In this study, we aimed to assess the feasibility of a combined approach of radiomics and machine learning...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-020-00336-y

    authors: Stanzione A,Ricciardi C,Cuocolo R,Romeo V,Petrone J,Sarnataro M,Mainenti PP,Improta G,De Rosa F,Insabato L,Brunetti A,Maurea S

    更新日期:2020-08-01 00:00:00

  • Financial assessment of a picture archiving and communication system implemented all at once.

    abstract::The objective of this study was to determine the differential cost between film-based radiology and a hospital-wide picture archiving and communication system (PACS) implemented all at once. The cash flow and running costs of PACS and film-based operation were measured over an 8-year time horizon. When the hospital-wi...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-0632-6

    authors: Fang YC,Yang MC,Hsueh YS

    更新日期:2006-01-01 00:00:00

  • Assessing the accuracy factors in the determination of postoperative acetabular cup orientation using hybrid 2D-3D registration.

    abstract::Single standard anteroposterior radiograph-based methods for measuring cup orientation following total hip arthroplasty (THA) are subject to substantial errors if the individual pelvic orientation with respect to X-ray plate is not taken into consideration. Previously, we proposed to use a hybrid 2D-3D registration sc...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-009-9226-4

    authors: Zheng G

    更新日期:2010-12-01 00:00:00

  • Image terminal series of Hokkaido University picture archiving communication system.

    abstract::In Hokkaido University Hospital, the large-scale PACS has been in clinical use since 1989. We developed various kinds of imaging terminals such as the image input terminal and the image display terminal for this system. This article presents detailed description of these terminals. ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168146

    authors: Ozaki Y,Miyasaka K

    更新日期:1991-11-01 00:00:00

  • An Audio/Video Reporting Workflow to Supplement Standardized Radiology Reports.

    abstract::Radiology studies are inherently visual and the information contained within is best conveyed by visual methodology. Advanced reporting software allows the incorporation of annotated key images into text reports, but such features may be less effective compared with in-person consultations. The use of web technology a...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-015-9821-5

    authors: Balkman JD,Siegel AH

    更新日期:2016-04-01 00:00:00

  • Sophisticated hospital information system/radiology information system/picture archiving and communications system (PACS) integration in a large-scale traumatology PACS.

    abstract::Picture archiving and communications system (PACS) in the context of an outpatient trauma care center asks for a high level of interaction between information systems to guarantee rapid image acquisition and distribution to the surgeon. During installation of the Innsbruck PACS, special aspects of traumatology had to ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168769

    authors: Peer S,Vogl R,Peer R,Jaschke W

    更新日期:1999-05-01 00:00:00

  • Characterization of monochrome CRT display systems in the field.

    abstract::This article presents a review of image quality assessment methods for monochrome CRTs in the field as opposed to the laboratory. The review includes image quality programs at the University of Washington, the University of Texas at Houston, the University of Michigan, and the University of Arizona. CRT manufacturers ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168851

    authors: Roehrig H,Willis CE,Damento MA

    更新日期:1999-11-01 00:00:00

  • A comparison of hard and soft copies processed with linear conversion and nonlinear conversion of skeletal fractures--a preliminary study.

    abstract::To compare hard copies and soft copies processed with linear and nonlinear conversion of skeletal fractures, we performed a receiver-operating characteristics study of 25 digital radiographs. There was no statistical difference between hard copies with linear and nonlinear conversion. However, it may be difficult to d...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168067

    authors: Kaji T,Katayama M,Kosuda S,Kusano S

    更新日期:1995-02-01 00:00:00

  • A heuristic approach to automated nipple detection in digital mammograms.

    abstract::In this paper, a heuristic approach to automated nipple detection in digital mammograms is presented. A multithresholding algorithm is first applied to segment the mammogram and separate the breast region from the background region. Next, the problem is considered separately for craniocaudal (CC) and mediolateral-obli...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9575-x

    authors: Jas M,Mukhopadhyay S,Chakraborty J,Sadhu A,Khandelwal N

    更新日期:2013-10-01 00:00:00

  • Early lung cancer detection using the self-evaluation scoring questionnaire and chest digital radiography: a 3-year follow-up study in China.

    abstract::The standard definition of high-risk individuals for lung cancer was not uniform and the value of chest digital radiography (DR) in lung cancer screening was still unproven. The aim of this study was to assess whether the original questionnaire named as "Self-evaluation Scoring Questionnaire for High-risk Individuals ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9468-4

    authors: Chen B,Wang Y,Cao H,Liu D,Zhang S,Gao J,Yu J,Huang Y,Li W

    更新日期:2013-02-01 00:00:00

  • Assessment of coronary artery calcium using dual-energy subtraction digital radiography.

    abstract::Cardiovascular disease is the leading cause of global mortality, yet its early detection remains a vexing problem of modern medicine. Although the computed tomography (CT) calcium score predicts cardiovascular risk, relatively high cost ($250-400) and radiation dose (1-3 mSv) limit its universal utility as a screening...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9385-y

    authors: Mafi JN,Fei B,Roble S,Dota A,Katrapati P,Bezerra HG,Wang H,Wang W,Ciancibello L,Costa M,Simon DI,Orringer CE,Gilkeson RC

    更新日期:2012-02-01 00:00:00

  • Optimizing technology development and adoption in medical imaging using the principles of innovation diffusion, part II: practical applications.

    abstract::Successful adoption of new technology development can be accentuated by learning and applying the scientific principles of innovation diffusion. This is of particular importance to areas within the medical imaging practice which have lagged in innovation; perhaps, the most notable of which is reporting which has remai...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-011-9409-7

    authors: Reiner BI

    更新日期:2012-02-01 00:00:00

  • A Feasibility Study of Smartphone-Based Telesonography for Evaluating Cardiac Dynamic Function and Diagnosing Acute Appendicitis with Control of the Image Quality of the Transmitted Videos.

    abstract::Our aim was to prove the feasibility of the remote interpretation of real-time transmitted ultrasound videos of dynamic and static organs using a smartphone with control of the image quality given a limited internet connection speed. For this study, 100 cases of echocardiography videos (dynamic organ)-50 with an eject...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-015-9849-6

    authors: Kim C,Cha H,Kang BS,Choi HJ,Lim TH,Oh J

    更新日期:2016-06-01 00:00:00

  • Variability of semiautomated lung nodule volumetry on ultralow-dose CT: comparison with nodule volumetry on standard-dose CT.

    abstract::The study investigates the effect of a substantial dose reduction on the variability of lung nodule volume measurements by assessing and comparing nodule volumes using a dedicated semiautomated segmentation software on ultralow-dose computed tomography (ULD-CT) and standard-dose computed tomography (SD-CT) data. In 20...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-008-9157-5

    authors: Hein PA,Romano VC,Rogalla P,Klessen C,Lembcke A,Bornemann L,Dicken V,Hamm B,Bauknecht HC

    更新日期:2010-02-01 00:00:00

  • What is a wiki, and how can it be used in resident education?

    abstract::Training as a radiology resident is a complex task. Residents frequently encounter multiple hospital systems, each with unique workflow patterns and heterogenous information systems. We identified an opportunity to ease some of the resulting anxiety and frustration by centralizing high-quality resources using a wiki. ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-010-9292-7

    authors: Kohli MD,Bradshaw JK

    更新日期:2011-02-01 00:00:00

  • Digital processing of radiographic images from PACS to publishing.

    abstract::Several studies have addressed the implications of filmless radiologic imaging on telemedicine, diagnostic ability, and electronic teaching files. However, many publishers still require authors to submit hard-copy images for publication of articles and textbooks. This study compares the quality digital images directly...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-001-0019-7

    authors: Christian ME,Davidson HC,Wiggins RH 3rd,Berges G,Cannon G,Jackson G,Chapman B,Harnsberger HR

    更新日期:2001-03-01 00:00:00

  • Demonstration of digital radiographs by means of ink jet-printed paper copies: pilot study.

    abstract::Different digital medical images have been printed on paper with a continuous ink jet printer, and the quality has been evaluated. The emphasis has been on digital chest radiographs from a computed radiography system. The ink jet printing technique is described as well as the handling of the image data from image sour...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167806

    authors: Kirkhorn T,Kehler M,Nilsson J,Lyttkens K,Andersson B,Holmer NG

    更新日期:1992-11-01 00:00:00

  • Free DICOM-Viewers for Veterinary Medicine : Survey and Comparison of Functionality and User-Friendliness of Medical Imaging PACS-DICOM-Viewer Freeware for Specific Use in Veterinary Medicine Practices.

    abstract::There is increasing prevalence of digital diagnostic imaging in veterinary medicine with a progressive need to use medical imaging software. As Digital Imaging and Communications in Medicine (DICOM)-viewers for veterinary use do not require medical device approval in many countries, freeware viewers might be a practic...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00194-3

    authors: Brühschwein A,Klever J,Hoffmann AS,Huber D,Kaufmann E,Reese S,Meyer-Lindenberg A

    更新日期:2020-02-01 00:00:00

  • A IHE-Like Approach Method for Quantitative Analysis of PACS Usage.

    abstract::Today, many hospitals have a running enterprise picture archiving and communication system (PACS) and their administrators should have the tools to measure the system activity and, in particular, how much it is used. The information would be valuable for decision-makers to address asset management and the development ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-016-9870-4

    authors: Calabrese R,Beltrame M,Accardo A

    更新日期:2016-12-01 00:00:00