Abstract:
:Cardiovascular disease is the leading cause of global mortality, yet its early detection remains a vexing problem of modern medicine. Although the computed tomography (CT) calcium score predicts cardiovascular risk, relatively high cost ($250-400) and radiation dose (1-3 mSv) limit its universal utility as a screening tool. Dual-energy digital subtraction radiography (DE; <$60, 0.07 mSv) enables detection of calcified structures with high sensitivity. In this pilot study, we examined DE radiography's ability to quantify coronary artery calcification (CAC). We identified 25 patients who underwent non-contrast CT and DE chest imaging performed within 12 months using documented CAC as the major inclusion criteria. A DE calcium score was developed based on pixel intensity multiplied by the area of the calcified plaque. DE scores were plotted against CT scores. Subsequently, a validation cohort of 14 additional patients was independently evaluated to confirm the accuracy and precision of CAC quantification, yielding a total of 39 subjects. Among all subjects (n = 39), the DE score demonstrated a correlation coefficient of 0.87 (p < 0.0001) when compared with the CT score. For the 13 patients with CT scores of <400, the correlation coefficient was -0.26. For the 26 patients with CT scores of ≥400, the correlation coefficient yielded 0.86. This pilot study demonstrates the feasibility of DE radiography to identify patients at the highest cardiovascular risk. DE radiography's accuracy at lower scores remains unclear. Further evaluation of DE radiography as an inexpensive and low-radiation imaging tool to diagnose cardiovascular disease appears warranted.
journal_name
J Digit Imagingjournal_title
Journal of digital imagingauthors
Mafi JN,Fei B,Roble S,Dota A,Katrapati P,Bezerra HG,Wang H,Wang W,Ciancibello L,Costa M,Simon DI,Orringer CE,Gilkeson RCdoi
10.1007/s10278-011-9385-ysubject
Has Abstractpub_date
2012-02-01 00:00:00pages
129-36issue
1eissn
0897-1889issn
1618-727Xjournal_volume
25pub_type
杂志文章abstract::In this article, we describe the development and validation of an automatic algorithm to segment brain from extracranial tissues, and to classify intracranial tissues as cerebrospinal fluid (CSF), gray matter (GM), white matter (WM) or pathology. T1 weighted spin echo, dual echo fast spin echo (T2 weighted and proton ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168729
更新日期:1998-05-01 00:00:00
abstract::A long-standing challenge of content-based image retrieval (CBIR) systems is the definition of a suitable distance function to measure the similarity between images in an application context which complies with the human perception of similarity. In this paper, we present a new family of distance functions, called att...
journal_title:Journal of digital imaging
pub_type: 杂志文章,评审
doi:10.1007/s10278-007-9084-x
更新日期:2009-04-01 00:00:00
abstract::Sacroiliac (SI) joint dislocations and sacral fractures of the pelvis can be stabilized by SI screws; however, screw insertion into a sacral isthmus region is risky for the adjacent neurovascular structures. Therefore, shape analyses of general SI screw corridors or safety zones are of great surgical interest; however...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-010-9327-0
更新日期:2011-08-01 00:00:00
abstract::A teleradiology system acquires radiographic images from one location and transmits them to one or more distant sites where they are displayed and/or converted to hard-copy film recordings. The long-term goal of teleradiology research is to show that teleradiology systems can provide diagnostically equivalent results ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03167763
更新日期:1992-08-01 00:00:00
abstract::Excessive cephalocaudal anatomic (Z-axis) coverage can lead to unnecessary radiation exposure to a patient. In this study, an automated computing model was developed for identifying instances of potentially excessive Z-axis coverage with abdomen-pelvis examinations. Eight patient and imaging attributes including patie...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-014-9743-7
更新日期:2015-06-01 00:00:00
abstract::The authors developed a temporal subtraction scheme based on a nonlinear geometric warping technique to assist radiologists in the detection of interval changes in chest radiographs obtained on different occasions. The performance of the current temporal subtraction scheme is reasonably good; however, severe misregist...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168846
更新日期:1999-05-01 00:00:00
abstract::To compare hard copies and soft copies processed with linear and nonlinear conversion of skeletal fractures, we performed a receiver-operating characteristics study of 25 digital radiographs. There was no statistical difference between hard copies with linear and nonlinear conversion. However, it may be difficult to d...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168067
更新日期:1995-02-01 00:00:00
abstract::Automatic bone segmentation of computed tomography (CT) images is an important step in image-guided surgery that requires both high accuracy and minimal user interaction. Previous attempts include global thresholding, region growing, region competition, watershed segmentation, and parametric active contour (AC) approa...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-009-9210-z
更新日期:2010-12-01 00:00:00
abstract::In this investigation the effect of JPEG 2000 compression on the contrast-detail (CD) characteristics of digital mammography images was studied using an alternative forced choice (AFC) technique. Images of a contrast-detail phantom, acquired using a clinical full-field digital mammography system, were compressed using...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-003-1728-x
更新日期:2004-03-01 00:00:00
abstract::Bone density measurement by quantitative computed tomography (QCT) commonly uses an external reference phantom to decrease scan-to-scan and scanner-to-scanner variability. However, the peripheral location of these phantoms and other phantom variables is also responsible for a measurable degradation in accuracy and pre...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168013
更新日期:1989-02-01 00:00:00
abstract::In this paper, a simplified yet efficient architecture of a deep convolutional neural network is presented for lung image classification. The images used for classification are computed tomography (CT) scan images obtained from two scientifically used databases available publicly. Six external shape-based features, vi...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-019-00245-9
更新日期:2020-02-01 00:00:00
abstract::A 10-bit or 12-bit gray scale is provided in commercial laser film digitizers. The true contrast resolution on the digitized image within a laser spot area of 200 microns in diameter is limited by both the quantum mottle and instrumentation noise. In this report, we investigated the mean value, standard deviation, and...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03170571
更新日期:1990-05-01 00:00:00
abstract::A prior ultrasound study indicated that images with low to moderate levels of JPEG and wavelet compression were acceptable for diagnostic purposes. The purpose of this study is to validate this prior finding using the Joint Photographic Experts Group (JPEG) baseline compression algorithm, at a compression ratio of app...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-002-0003-x
更新日期:2002-03-01 00:00:00
abstract::Understanding the scan patterns radiologists use to view medical images is critical to the design of image viewing devices. In this study, an eyetracker, a device for recording eye and head movement, was used to determine the scan patterns during the interpretation of single and multiple computed tomographic (CT) exam...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168120
更新日期:1990-11-01 00:00:00
abstract::Statistics show that the risk of autism spectrum disorder (ASD) is increasing in the world. Early diagnosis is most important factor in treatment of ASD. Thus far, the childhood diagnosis of ASD has been done based on clinical interviews and behavioral observations. There is a significant need to reduce the use of tra...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-019-00196-1
更新日期:2019-12-01 00:00:00
abstract::Electronic imaging clinical implementation strategies and principles need to be developed as we move toward replacement of film-based radiology practices. During an 8-month period (1998 to 1999), an Electronic Imaging Clinical Implementation Work Group (EICIWG) was formed from sections of our department: Informatics L...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168749
更新日期:1999-05-01 00:00:00
abstract::We have developed an algorithm for enhancement of spicules of spiculated masses, which uses the discrete radon transform. Previously, we employed a commonly used method to compute the discrete radon transform, which we refer to as the DRT. Recently, a new, more exact method to compute the discrete radon transform was ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-007-9015-x
更新日期:2008-03-01 00:00:00
abstract::This study was conducted to determine whether facial photographs obtained simultaneously with radiographs improve radiologists' detection rate of wrong-patient errors, when they are explicitly asked to include the photographs in their evaluation. Radiograph-photograph combinations were obtained from 28 patients at the...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-015-9808-2
更新日期:2015-12-01 00:00:00
abstract::A novel medical image quality index using grey relational coefficient calculation is proposed in this study. Three medical modalities, DR, CT and MRI, using 30 or 60 images with a total of 120 images used for experimentation. These images were first compressed at ten different compression ratios (10 ∼ 100) using a med...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-010-9353-y
更新日期:2011-10-01 00:00:00
abstract::The architectural design and construction of a new imaging department is one of the most complex challenges in healthcare architecture. When a client also plans a simultaneous change in basic operating system technology from film-based to filmless imaging, the challenge for both hospital management and the facility/te...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168779
更新日期:1999-05-01 00:00:00
abstract::To improve radiology access to full uncompressed Digital Imaging and Communications in Medicine (DICOM) data sets, we evaluated satellite access to a DICOM server. Radiologists' home computers were connected by satellite to a Medweb DICOM server (Medweb, San Francisco, CA). A 10.2-kb data set containing a 19-image hea...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168799
更新日期:1999-05-01 00:00:00
abstract::Clinical picture archiving and communications systems provide convenient, efficient access to digital medical images from multiple modalities but can prove challenging to deploy, configure and use. MRIdb is a self-contained image database, particularly suited to the storage and management of magnetic resonance imaging...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-013-9604-9
更新日期:2013-10-01 00:00:00
abstract::Considerable debate within the medical community has focused on the optimal location of information technology (IT) support groups on the organizational chart. The challenge has been to marry local accountability and physician acceptance of IT with the benefits gained by the economies of scale achieved by centralized ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-009-9196-6
更新日期:2009-06-01 00:00:00
abstract::While occupational stress and fatigue have been well described throughout medicine, the radiology community is particularly susceptible due to declining reimbursements, heightened demands for service deliverables, and increasing exam volume and complexity. The resulting occupational stress can be variable in nature an...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-012-9540-0
更新日期:2013-02-01 00:00:00
abstract::The objective of this study was to determine the clinical value of computed tomography (CT) image-based texture analysis in predicting microvascular invasion of primary hepatocellular carcinoma (HCC). CT images of patients with HCC from May 2017 to May 2019 confirmed by surgery and histopathology were retrospectively ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-020-00386-2
更新日期:2020-12-01 00:00:00
abstract::As resources in the healthcare environment continue to wane, leaders are seeking ways to continue to provide quality care bounded by the constraints of a reduced budget. This manuscript synthesizes the experience from a number of institutions to provide the healthcare leadership with an understanding of the value of a...
journal_title:Journal of digital imaging
pub_type: 杂志文章,评审
doi:10.1007/s10278-019-00293-1
更新日期:2020-02-01 00:00:00
abstract::Radiology studies are inherently visual and the information contained within is best conveyed by visual methodology. Advanced reporting software allows the incorporation of annotated key images into text reports, but such features may be less effective compared with in-person consultations. The use of web technology a...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-015-9821-5
更新日期:2016-04-01 00:00:00
abstract::Fiber tracking allows the in vivo reconstruction of human brain white matter fiber trajectories based on magnetic resonance diffusion tensor imaging (MR-DTI), but its application in the clinical routine is still in its infancy. In this study, we present a new software for fiber tracking, developed on top of a general-...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-006-0773-7
更新日期:2007-03-01 00:00:00
abstract::As hospitals convert from conventional film-based imaging to picture archival and communications systems (PACS), methods for managing an enormous library of images must change considerably. While most hospitals are required to retain general, nonmammographic, radiologic images for 7 years beyond the examination date, ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03190304
更新日期:2001-06-01 00:00:00
abstract::With the introduction of digital imaging in radiology, CD-Rs are increasingly used to distribute patient materials. This study investigates the application of a new software package and work protocol to integrate out-hospital data into the local PACS (picture archive and communication system) archive, which is hampere...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-005-5158-9
更新日期:2005-09-01 00:00:00