Application of temporal subtraction for detection of interval changes on chest radiographs: improvement of subtraction images using automated initial image matching.

Abstract:

:The authors developed a temporal subtraction scheme based on a nonlinear geometric warping technique to assist radiologists in the detection of interval changes in chest radiographs obtained on different occasions. The performance of the current temporal subtraction scheme is reasonably good; however, severe misregistration can occur in some cases. The authors evaluated the quality of 100 chest temporal subtraction images selected from their clinical image database. Severe misregistration was mainly attributable to initial incorrect global matching. Therefore, they attempted to improve the quality of the subtraction images by applying a new initial image matching technique to determine the global shift value between the current and the previous chest images. A cross-correlation method was employed for the initial image matching by use of blurred low-resolution chest images. Nineteen cases (40.4%) among 47 poor registered subtraction images were improved. These results show that the new initial image matching technique is very effective for improving the quality of chest temporal subtraction images, which can greatly enhance subtle changes in chest radiographs.

journal_name

J Digit Imaging

authors

Ishida T,Ashizawa K,Engelmann R,Katsuragawa S,MacMahon H,Doi K

doi

10.1007/BF03168846

subject

Has Abstract

pub_date

1999-05-01 00:00:00

pages

77-86

issue

2

eissn

0897-1889

issn

1618-727X

journal_volume

12

pub_type

杂志文章
  • Computer-aided diagnosis for detection of lacunar infarcts on MR images: ROC analysis of radiologists' performance.

    abstract::The purpose of this study was to retrospectively evaluate radiologist performance in detection of lacunar infarcts on T1- and T2-weighted images, without and with the use of a computer-aided diagnosis (CAD) scheme. Thirty T1-weighted and 30 T2-weighted MR images obtained from 30 patients were used for assessing observ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9444-4

    authors: Uchiyama Y,Asano T,Kato H,Hara T,Kanematsu M,Hoshi H,Iwama T,Fujita H

    更新日期:2012-08-01 00:00:00

  • SCAR R&D Symposium 2003: comparing the efficacy of 5-MP CRT versus 3-MP LCD in the evaluation of interstitial lung disease.

    abstract::The efficacy of two medical-grade, self-calibrating, gray scale displays were compared with regard to impact on sensitivity and specificity for the detection of interstitial lung disease (ILD) on computed radiographs (CR). The displays were a 5-megapixel (MP) cathode ray tube (CRT) device and a 3-MP liquid crystal dis...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-004-1013-7

    authors: Langer S,Bartholmai B,Fetterly K,Harmsen S,Ryan W,Erickson B,Andriole K,Carrino J

    更新日期:2004-09-01 00:00:00

  • Automated pediatric abdominal effective diameter measurements versus age-predicted body size for normalization of CT dose.

    abstract::There has been increasing interest in adjusting CT radiation dose data for patient body size. A method for automated computation of the abdominal effective diameter of a patient from a CT image has previously only been tested in adult patients. In this work, we tested the method on a set of 128 pediatric patients aged...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9623-6

    authors: Cheng PM,Vachon LA,Duddalwar VA

    更新日期:2013-12-01 00:00:00

  • Toward Data-Driven Radiology Education-Early Experience Building Multi-Institutional Academic Trainee Interpretation Log Database (MATILDA).

    abstract::The residency review committee of the Accreditation Council of Graduate Medical Education (ACGME) collects data on resident exam volume and sets minimum requirements. However, this data is not made readily available, and the ACGME does not share their tools or methodology. It is therefore difficult to assess the integ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s10278-016-9872-2

    authors: Chen PH,Loehfelm TW,Kamer AP,Lemmon AB,Cook TS,Kohli MD

    更新日期:2016-12-01 00:00:00

  • Contrast information of digital imaging in laser film digitizer and display monitor.

    abstract::A 10-bit or 12-bit gray scale is provided in commercial laser film digitizers. The true contrast resolution on the digitized image within a laser spot area of 200 microns in diameter is limited by both the quantum mottle and instrumentation noise. In this report, we investigated the mean value, standard deviation, and...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03170571

    authors: Lo SC,Gaskill JW,Mun SK,Krasner BH

    更新日期:1990-05-01 00:00:00

  • Simulation of disaster recovery of a picture archiving and communications system using off-site hierarchal storage management.

    abstract::The purpose of this communication is to report on the testing of the disaster recovery capability of our hierarchical storage management (HSM) system. Disaster recovery implementation is a requirement of every mission-critical information technology project. Picture archiving and communications systems (PACS) certainl...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167652

    authors: Avrin DE,Andriole KP,Yin L,Gould R,Arenson RL

    更新日期:2000-05-01 00:00:00

  • Toward Automatic Detection of Radiation-Induced Cerebral Microbleeds Using a 3D Deep Residual Network.

    abstract::Cerebral microbleeds, which are small focal hemorrhages in the brain that are prevalent in many diseases, are gaining increasing attention due to their potential as surrogate markers of disease burden, clinical outcomes, and delayed effects of therapy. Manual detection is laborious and automatic detection and labeling...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0146-z

    authors: Chen Y,Villanueva-Meyer JE,Morrison MA,Lupo JM

    更新日期:2019-10-01 00:00:00

  • Characterization of monochrome CRT display systems in the field.

    abstract::This article presents a review of image quality assessment methods for monochrome CRTs in the field as opposed to the laboratory. The review includes image quality programs at the University of Washington, the University of Texas at Houston, the University of Michigan, and the University of Arizona. CRT manufacturers ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168851

    authors: Roehrig H,Willis CE,Damento MA

    更新日期:1999-11-01 00:00:00

  • Effect of Interventional Program on the Utilization of PACS in Point-of-Care Ultrasound.

    abstract::While the implementation of Picture Archiving and Communication Systems (PACS) has revolutionized the field of radiology, there has been considerably less utilization of PACS by emergency physicians with point-of-care ultrasound. Benefits of PACS archival of images include improved quality assurance, preservation of i...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-016-9893-x

    authors: Kessler R,Stowell JR,Vogel JA,Liao MM,Kendall JL

    更新日期:2016-12-01 00:00:00

  • PDA-phone-based instant transmission of radiological images over a CDMA network by combining the PACS screen with a Bluetooth-interfaced local wireless link.

    abstract::Remote teleconsultation by specialists is important for timely, correct, and specialized emergency surgical and medical decision making. In this paper, we designed a new personal digital assistant (PDA)-phone-based emergency teleradiology system by combining cellular communication with Bluetooth-interfaced local wirel...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-007-9002-2

    authors: Kim DK,Yoo SK,Park JJ,Kim SH

    更新日期:2007-06-01 00:00:00

  • A perceptual evaluation of JPEG 2000 image compression for digital mammography: contrast-detail characteristics.

    abstract::In this investigation the effect of JPEG 2000 compression on the contrast-detail (CD) characteristics of digital mammography images was studied using an alternative forced choice (AFC) technique. Images of a contrast-detail phantom, acquired using a clinical full-field digital mammography system, were compressed using...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-003-1728-x

    authors: Suryanarayanan S,Karellas A,Vedantham S,Waldrop SM,D'Orsi CJ

    更新日期:2004-03-01 00:00:00

  • MABAL: a Novel Deep-Learning Architecture for Machine-Assisted Bone Age Labeling.

    abstract::Bone age assessment (BAA) is a commonly performed diagnostic study in pediatric radiology to assess skeletal maturity. The most commonly utilized method for assessment of BAA is the Greulich and Pyle method (Pediatr Radiol 46.9:1269-1274, 2016; Arch Dis Child 81.2:172-173, 1999) atlas. The evaluation of BAA can be a t...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0053-3

    authors: Mutasa S,Chang PD,Ruzal-Shapiro C,Ayyala R

    更新日期:2018-08-01 00:00:00

  • A model for achieving total quality-management information technology infrastructure within an integrated delivery system.

    abstract::The strategic development and deployment of a health management information technology infrastructure is discussed from two perspectives for radiologists and for other medical technologists: the integrated delivery system (IDS) perspective and a total quality-management (TQM) perspective. On the one hand, an IDS persp...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168176

    authors: Tan JK

    更新日期:1998-11-01 00:00:00

  • The effect of lossy discrete cosine transform compression on subtle bone fractures.

    abstract::Extensive research efforts have been devoted to the feasibility of picture archiving and communication systems (PACS) in recent years. The advantages of PACS are numerous but mainly include reduced cost and improvement in the operational efficiency of a PACS-based radiology department. In digital radiography, images a...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168839

    authors: Toney MO,Dominguez R,Dao HN,Simmons G

    更新日期:1997-11-01 00:00:00

  • Automated routing of DICOM CT, MR, and CR images: solving the pitfalls of vendor-specific DICOM implementations.

    abstract::This paper details our experience in developing and implementing an automated DICOM Image Router. This workstation serves as a gateway between image acquisition devices and image display and storage devices. Images are checked for demographic input errors and data format inconsistencies between the source and destinat...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168283

    authors: Junck KL,McEachern M,Grandhi S,Lewey G

    更新日期:1998-08-01 00:00:00

  • The Effect of Registration on Voxel-Wise Tofts Model Parameters and Uncertainties from DCE-MRI of Early-Stage Breast Cancer Patients Using 3DSlicer.

    abstract::We quantitatively investigate the influence of image registration, using open-source software (3DSlicer), on kinetic analysis (Tofts model) of dynamic contrast enhanced MRI of early-stage breast cancer patients. We also show that registration computation time can be reduced by reducing the percent sampling (PS) of vox...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-020-00374-6

    authors: Mouawad M,Biernaski H,Brackstone M,Lock M,Kornecki A,Shmuilovich O,Ben-Nachum I,Prato FS,Thompson RT,Gaede S,Gelman N

    更新日期:2020-10-01 00:00:00

  • Who You Gonna Call? Automatically Connecting Radiologists to the Right Clinician.

    abstract::Contacting clinicians to convey critical results is a critical part of radiology workflow, but many obstacles prevent easy and timely communication. Integration of radiology applications and workflow with an EHR-based patient coverage database demonstrated subjective and objective improvement in radiologist workflow a...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-017-9962-9

    authors: Filice R

    更新日期:2017-10-01 00:00:00

  • Estimates of Patient Radiation Doses in Digital Radiography Using DICOM Information at a Large Teaching Hospital in Oman.

    abstract::In this study, we sought to estimate the patient radiation doses in the digital radiography X-ray examinations conducted in a large hospital. The patient exposure factors and kerma-area product (PKA) were retrospectively recorded via the Digital Imaging and Communications in Medicine (DICOM) header for 547 patients. T...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00199-y

    authors: Suliman II

    更新日期:2020-02-01 00:00:00

  • Automated hands-free image manipulation and viewing: a useful macro feature that assists radiologists in the viewing of chest and extremity digital radiographs.

    abstract::The authors present an adaptation of the macro recording feature on the Siemens Magic View 1000 workstation, which, with the click of one button, launches a macro that performs 3 clinically useful image manipulations. Using a Magic View 1004 Siemens unix workstation, the following Macro sequence was programmed: (1) se...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-002-5078-x

    authors: Koenker RM,Grover SA

    更新日期:2002-01-01 00:00:00

  • Fibrous Dysplasia Characterization Using Lacunarity Analysis.

    abstract::Fibrous dysplasia (FD) is a developmental anomaly in which the normal medullary space of the affected bone is replaced by fibro-osseous tissue. This condition is typically encountered in adolescents and young adults. It affects the maxillofacial region and it can often cause severe deformity and asymmetry. Therefore, ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-015-9815-3

    authors: Cordeiro MS,Backes AR,Júnior AF,Gonçalves EH,de Oliveira JX

    更新日期:2016-02-01 00:00:00

  • Large-Scale Assessment of Scan-Time Variability and Multiple-Procedure Efficiency for Cross-Sectional Neuroradiological Exams in Clinical Practice.

    abstract::Scheduling of CT and MR exams requires reasonable estimates for expected scan duration. However, scan-time variability and efficiency gains from combining multiple exams are not quantitatively well characterized. In this work, we developed an informatics approach to quantify typical duration, duration variability, and...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00252-w

    authors: Zhang R,Narra VR,Kansagra AP

    更新日期:2020-02-01 00:00:00

  • Improving Visibility of Stereo-Radiographic Spine Reconstruction with Geometric Inferences.

    abstract::Complex deformities of the spine, like scoliosis, are evaluated more precisely using stereo-radiographic 3D reconstruction techniques. Primarily, it uses six stereo-corresponding points available on the vertebral body for the 3D reconstruction of each vertebra. The wireframe structure obtained in this process has poor...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-015-9841-1

    authors: Kumar S,Nayak KP,Hareesha KS

    更新日期:2016-04-01 00:00:00

  • Precise measurement of vertebral bone density using computed tomography without the use of an external reference phantom.

    abstract::Bone density measurement by quantitative computed tomography (QCT) commonly uses an external reference phantom to decrease scan-to-scan and scanner-to-scanner variability. However, the peripheral location of these phantoms and other phantom variables is also responsible for a measurable degradation in accuracy and pre...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168013

    authors: Boden SD,Goodenough DJ,Stockham CD,Jacobs E,Dina T,Allman RM

    更新日期:1989-02-01 00:00:00

  • A Feasibility Study of Smartphone-Based Telesonography for Evaluating Cardiac Dynamic Function and Diagnosing Acute Appendicitis with Control of the Image Quality of the Transmitted Videos.

    abstract::Our aim was to prove the feasibility of the remote interpretation of real-time transmitted ultrasound videos of dynamic and static organs using a smartphone with control of the image quality given a limited internet connection speed. For this study, 100 cases of echocardiography videos (dynamic organ)-50 with an eject...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-015-9849-6

    authors: Kim C,Cha H,Kang BS,Choi HJ,Lim TH,Oh J

    更新日期:2016-06-01 00:00:00

  • How to create radiology papers and presentations in Windows with Open-Source software.

    abstract::To illustrate the availability, effectiveness, and practical use of Open-Source tools in developing a radiology paper from its beginning to its presentation and publication. Practical use of a complete set of Open-Source applications for writing, e-mail corresponding, slide show, image retrieval, and manipulation is s...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-008-9159-3

    authors: Faccioli N,Perandini S,Barillari M,D'Onofrio M,Mucelli RP

    更新日期:2009-12-01 00:00:00

  • Indexing thoracic CT reports using a preliminary version of a standardized radiological lexicon (RadLex).

    abstract:INTRODUCTION:To validate a preliminary version of a radiological lexicon (RadLex) against terms found in thoracic CT reports and to index report content in RadLex term categories. MATERIAL AND METHODS:Terms from a random sample of 200 thoracic CT reports were extracted using a text processor and matched against RadLex...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-007-9051-6

    authors: Marwede D,Schulz T,Kahn T

    更新日期:2008-12-01 00:00:00

  • An effective approach of lesion segmentation within the breast ultrasound image based on the cellular automata principle.

    abstract::In this paper, a novel lesion segmentation within breast ultrasound (BUS) image based on the cellular automata principle is proposed. Its energy transition function is formulated based on global image information difference and local image information difference using different energy transfer strategies. First, an en...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9450-6

    authors: Liu Y,Cheng HD,Huang J,Zhang Y,Tang X

    更新日期:2012-10-01 00:00:00

  • Financial assessment of a picture archiving and communication system implemented all at once.

    abstract::The objective of this study was to determine the differential cost between film-based radiology and a hospital-wide picture archiving and communication system (PACS) implemented all at once. The cash flow and running costs of PACS and film-based operation were measured over an 8-year time horizon. When the hospital-wi...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-0632-6

    authors: Fang YC,Yang MC,Hsueh YS

    更新日期:2006-01-01 00:00:00

  • Clinical impact of picture archiving and communication systems: evaluation of a prototype system.

    abstract::Opinion surveys were gathered before and 6 months after installation of a prototype picture archiving and communication system (PACS) (PACS/1, Siemens Medical Systems, Iselin, NJ). Median turnaround times and the percent of delayed or missing reports were calculated for 1,026 baseline and 8,438 follow-up studies at 6 ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167836

    authors: Worrell JA,Federspiel CF,Creasy JL,Pickens DR 3rd,Higginbotham K,Patton JA,Partain CL

    更新日期:1992-05-01 00:00:00

  • The Enterprise Imaging Value Proposition.

    abstract::As resources in the healthcare environment continue to wane, leaders are seeking ways to continue to provide quality care bounded by the constraints of a reduced budget. This manuscript synthesizes the experience from a number of institutions to provide the healthcare leadership with an understanding of the value of a...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-019-00293-1

    authors: Petersilge CA

    更新日期:2020-02-01 00:00:00