Abstract:
:The purpose of this study was to retrospectively evaluate radiologist performance in detection of lacunar infarcts on T1- and T2-weighted images, without and with the use of a computer-aided diagnosis (CAD) scheme. Thirty T1-weighted and 30 T2-weighted MR images obtained from 30 patients were used for assessing observer performance. These images were acquired using the fast spin-echo sequence with a 1.5-T MR imaging scanner. The group included 15 patients (age range, 48-83 years; mean age, 67.2 years; 10 men and five women) with a lacunar infarct and 15 patients (age range, 39-76 years; mean age, 64.0 years; eight men and seven women) without lacunar infarcts. Nine radiologists participated in the study. The radiologists initially interpreted the T1- and T2-weighted images without and then with the use of CAD, which indicated their confidence levels regarding the presence (or absence) of lacunar infarcts and the most likely position of a lesion on each MR scan. The observers' performance without and with the computer output was evaluated by performing receiver operating characteristic analysis. For the nine radiologists, the mean area under the best-fit binormal receiver operating characteristic curve plotted for unit square values of radiologists who interpreted the images without and with the scheme were 0.891 and 0.937, respectively. The performance of the radiologists improved significantly when they used the computer output (p=0.032). The CAD scheme has potential to improve the accuracy of radiologists' performance in detection of lacunar infarcts.
journal_name
J Digit Imagingjournal_title
Journal of digital imagingauthors
Uchiyama Y,Asano T,Kato H,Hara T,Kanematsu M,Hoshi H,Iwama T,Fujita Hdoi
10.1007/s10278-011-9444-4subject
Has Abstractpub_date
2012-08-01 00:00:00pages
497-503issue
4eissn
0897-1889issn
1618-727Xjournal_volume
25pub_type
杂志文章abstract::The purpose of this study is to assess the accuracy, precision, and rapidity of liver volumes calculated by using a freehand electromagnetic pen tablet contourtracing method as compared with the volumes calculated by using the standard optical mouse contourtracing method. The imaging data used as input for accuracy an...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-010-9291-8
更新日期:2011-04-01 00:00:00
abstract::This is the second article of our series for radiologists and imaging scientists on displaying, manipulating, and analyzing radiologic images on personal computers (PCs). The first article discussed the digital image data file, standard PC graphic file formats, and various methods for importing radiologic images into ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168488
更新日期:1993-08-01 00:00:00
abstract::Rapid advances are changing the technology and applications of multidetector computed tomography (CT) scanners. The major increase in data associated with this new technology, however, breaks most commercial picture archiving and communication system (PACS) architectures by preventing them from delivering data in real...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-006-0925-9
更新日期:2006-01-01 00:00:00
abstract::To solve the problems of image displays in filmless radiology conferences for the purpose of teaching, we made an experimental design of a conference system with dual 50-in. plasma monitors for displaying larger images and a shared folder containing shortcuts to images for quick display during conferences on the deskt...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-007-9095-7
更新日期:2009-12-01 00:00:00
abstract::We examined the potential of the iPad 2 as a teleradiologic tool for evaluating brain computed tomography (CT) with subtle hemorrhage in the conventional lighting conditions which are common situations in the remote CT reading. The comparison of the clinician's performance was undertaken through detecting hemorrhage b...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-013-9580-0
更新日期:2013-08-01 00:00:00
abstract::Medical images produced by x-ray detectors, computed tomography (CT) scanners, and other modalities typically contain between 12-16 bits/pixel, which corresponds to 4,096-65,536 shades of gray. On the other hand, we see that these images are visualized by means of medical displays that have much lower available number...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-006-1052-3
更新日期:2007-12-01 00:00:00
abstract::Mammographic breast density has been established as an independent risk marker for developing breast cancer. Breast density assessment is a routine clinical need in breast cancer screening and current standard is using the Breast Imaging and Reporting Data System (BI-RADS) criteria including four qualitative categorie...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-017-0022-2
更新日期:2018-08-01 00:00:00
abstract::Sacroiliac (SI) joint dislocations and sacral fractures of the pelvis can be stabilized by SI screws; however, screw insertion into a sacral isthmus region is risky for the adjacent neurovascular structures. Therefore, shape analyses of general SI screw corridors or safety zones are of great surgical interest; however...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-010-9327-0
更新日期:2011-08-01 00:00:00
abstract::This paper details our experience in developing and implementing an automated DICOM Image Router. This workstation serves as a gateway between image acquisition devices and image display and storage devices. Images are checked for demographic input errors and data format inconsistencies between the source and destinat...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168283
更新日期:1998-08-01 00:00:00
abstract::This is the fifth and final article in our series for radiologists and imaging scientists on displaying, manipulating, and analyzing radiologic images on personal computers (PCs). There are many methods of transferring radiologic images into a PC, including transfer over a network, transfer from an imaging modality st...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168502
更新日期:1994-08-01 00:00:00
abstract::A study was conducted to evaluate the sensitivity of computer-aided detection (CAD) with full-field digital mammography in detection of breast cancer, based on mammographic appearance and histopathology. Retrospectively, CAD sensitivity was assessed in total group of 152 cases for subgroups based on breast density, ma...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-012-9564-5
更新日期:2013-08-01 00:00:00
abstract::The aim of this study was to design a tele-radiology imaging system for rapid emergency care via mobile networks and to assess the diagnostic feasibility of the Joint Photographic Experts Group 2000 (JPEG2000) radiological imaging using portable devices. Rapid patient information and image exchange is helpful to make ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-010-9335-0
更新日期:2011-08-01 00:00:00
abstract::There is increasing prevalence of digital diagnostic imaging in veterinary medicine with a progressive need to use medical imaging software. As Digital Imaging and Communications in Medicine (DICOM)-viewers for veterinary use do not require medical device approval in many countries, freeware viewers might be a practic...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-019-00194-3
更新日期:2020-02-01 00:00:00
abstract::Emission tomographic image reconstruction is an ill-posed problem due to limited and noisy data and various image-degrading effects affecting the data and leads to noisy reconstructions. Explicit regularization, through iterative reconstruction methods, is considered better to compensate for reconstruction-based noise...
journal_title:Journal of digital imaging
pub_type: 杂志文章,评审
doi:10.1007/s10278-015-9853-x
更新日期:2016-06-01 00:00:00
abstract::Computed radiography (CR) has various advantages such as dynamic range. Diagnostic accuracy with CR using reduced radiation dose is considered comparable with that of conventional film-screen radiography in diagnosing apparent chest abnormalities. In addition to reducing the radiation dose, delineation of the various ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168076
更新日期:1995-02-01 00:00:00
abstract::An integrated picture archiving and communication system (PACS) is a large investment in both money and resources. With all of the components and systems contained in the PACS, a methodical set of protocols and procedures must be developed to test all aspects of the PACS within the short time allocated for contract co...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168789
更新日期:1999-05-01 00:00:00
abstract::This article describes the design and implementation of a low-cost image archival and management solution on a radiology network consisting of UNIX, IBM personal computer-compatible (IBM, Purchase, NY) and Macintosh (Apple Computer, Cupertino, CA) workstations. The picture archiving and communications system (PACS) is...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168688
更新日期:1997-08-01 00:00:00
abstract::The need for tools to monitor imaging-related radiation has grown dramatically in recent years. RADIANCE, a freely available open-source dose-monitoring tool, was developed in response to the need for an informatics solution in this realm. A number of open-source as well as commercial solutions have since been develop...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-013-9570-2
更新日期:2013-08-01 00:00:00
abstract::Remote teleconsultation by specialists is important for timely, correct, and specialized emergency surgical and medical decision making. In this paper, we designed a new personal digital assistant (PDA)-phone-based emergency teleradiology system by combining cellular communication with Bluetooth-interfaced local wirel...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-007-9002-2
更新日期:2007-06-01 00:00:00
abstract::The three-dimensional (3D) visualization of dural venous sinuses (DVS) networks is desired by surgical trainers to create a clear mental picture of the neuroanatomical orientation of the complex cerebral anatomy. Our purpose is to document those identified during routine 3D venography created through 3D models using t...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-018-0125-4
更新日期:2019-04-01 00:00:00
abstract::In this investigation the effect of JPEG 2000 compression on the contrast-detail (CD) characteristics of digital mammography images was studied using an alternative forced choice (AFC) technique. Images of a contrast-detail phantom, acquired using a clinical full-field digital mammography system, were compressed using...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-003-1728-x
更新日期:2004-03-01 00:00:00
abstract::While occupational stress and fatigue have been well described throughout medicine, the radiology community is particularly susceptible due to declining reimbursements, heightened demands for service deliverables, and increasing exam volume and complexity. The resulting occupational stress can be variable in nature an...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-012-9540-0
更新日期:2013-02-01 00:00:00
abstract::In this paper, we propose a new method for stitching multiple fluoroscopic images taken by a C-arm instrument. We employ an X-ray radiolucent ruler with numbered graduations while acquiring the images, and the image stitching is based on detecting and matching ruler parts in the images to the corresponding parts of a ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-014-9763-3
更新日期:2015-08-01 00:00:00
abstract::This study was conducted to determine whether facial photographs obtained simultaneously with radiographs improve radiologists' detection rate of wrong-patient errors, when they are explicitly asked to include the photographs in their evaluation. Radiograph-photograph combinations were obtained from 28 patients at the...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-015-9808-2
更新日期:2015-12-01 00:00:00
abstract::Considerable debate within the medical community has focused on the optimal location of information technology (IT) support groups on the organizational chart. The challenge has been to marry local accountability and physician acceptance of IT with the benefits gained by the economies of scale achieved by centralized ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-009-9196-6
更新日期:2009-06-01 00:00:00
abstract::A prior ultrasound study indicated that images with low to moderate levels of JPEG and wavelet compression were acceptable for diagnostic purposes. The purpose of this study is to validate this prior finding using the Joint Photographic Experts Group (JPEG) baseline compression algorithm, at a compression ratio of app...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-002-0003-x
更新日期:2002-03-01 00:00:00
abstract::Successful adoption of new technology development can be accentuated by learning and applying the scientific principles of innovation diffusion. This is of particular importance to areas within the medical imaging practice which have lagged in innovation; perhaps, the most notable of which is reporting which has remai...
journal_title:Journal of digital imaging
pub_type: 杂志文章,评审
doi:10.1007/s10278-011-9409-7
更新日期:2012-02-01 00:00:00
abstract::This article describes a segmentation technique that uses the watershed transformation to provide mass detection in dense breast digitized images. The technique consists of four steps: preprocessing, which isolates the breast from the image background; histogram equalization to enhance the contrast; watershed transfor...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-002-5071-4
更新日期:2002-01-01 00:00:00
abstract::Complex deformities of the spine, like scoliosis, are evaluated more precisely using stereo-radiographic 3D reconstruction techniques. Primarily, it uses six stereo-corresponding points available on the vertebral body for the 3D reconstruction of each vertebra. The wireframe structure obtained in this process has poor...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-015-9841-1
更新日期:2016-04-01 00:00:00
abstract::The residency review committee of the Accreditation Council of Graduate Medical Education (ACGME) collects data on resident exam volume and sets minimum requirements. However, this data is not made readily available, and the ACGME does not share their tools or methodology. It is therefore difficult to assess the integ...
journal_title:Journal of digital imaging
pub_type: 杂志文章,多中心研究
doi:10.1007/s10278-016-9872-2
更新日期:2016-12-01 00:00:00