A method for computing general sacroiliac screw corridors based on CT scans of the pelvis.

Abstract:

:Sacroiliac (SI) joint dislocations and sacral fractures of the pelvis can be stabilized by SI screws; however, screw insertion into a sacral isthmus region is risky for the adjacent neurovascular structures. Therefore, shape analyses of general SI screw corridors or safety zones are of great surgical interest; however, before such analyses can be conducted, a method for computing 3D models of general SI corridors from routine clinical computed tomography (CT) scans has to be developed. This work describes a method for determining general corridors in pelvic CT data for accurate screw placement into the first sacral body. The method is implemented with the computer language C++. The pelvic CT data are preprocessed before the presented algorithm computes a model of the 3D corridor volume. Additionally, the two most important parameters of the algorithm, the raster step and the virtual SI screw diameter, have been characterized. The result of the work is an algorithm for computing general SI screw corridors and its implementation. Additionally the influences of two important parameters, the raster step and the SI screw diameter, on corridor volume precision and computation time have been quantified for the test sample. We conclude that the method can be used in further corridor shape analyses with a large number of pelvic CT data sets for investigating general SI screw corridors and clinical consequences for the placements of the screws. Implementation of the presented software algorithm could also enhance performance of computer-assisted surgery in the near future.

journal_name

J Digit Imaging

authors

Noser H,Radetzki F,Stock K,Mendel T

doi

10.1007/s10278-010-9327-0

subject

Has Abstract

pub_date

2011-08-01 00:00:00

pages

665-71

issue

4

eissn

0897-1889

issn

1618-727X

journal_volume

24

pub_type

杂志文章
  • Computer-aided diagnosis for detection of lacunar infarcts on MR images: ROC analysis of radiologists' performance.

    abstract::The purpose of this study was to retrospectively evaluate radiologist performance in detection of lacunar infarcts on T1- and T2-weighted images, without and with the use of a computer-aided diagnosis (CAD) scheme. Thirty T1-weighted and 30 T2-weighted MR images obtained from 30 patients were used for assessing observ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9444-4

    authors: Uchiyama Y,Asano T,Kato H,Hara T,Kanematsu M,Hoshi H,Iwama T,Fujita H

    更新日期:2012-08-01 00:00:00

  • A study for watermark methods appropriate to medical images.

    abstract::The network system, including the picture archiving and communication system (PACS), is essential in hospital and medical imaging fields these days. Many medical images are accessed and processed on the web, as well as in PACS. Therefore, any possible accidents caused by the illegal modification of medical images must...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03190332

    authors: Cho Y,Ahn B,Kim JS,Kim IY,Kim SI

    更新日期:2001-06-01 00:00:00

  • Imaging Informatics Fellowship Curriculum: a Survey to Identify Core Topics and Potential Inter-Program Areas of Collaboration.

    abstract::New consumer technologies and interoperability standards have dated the first standardized curriculum for imaging informatics fellowships suggested by the Society for Computer Applications in Radiology (SCAR) in 2004 (Journal of digital imaging 17(4):244-248, 2004). Last year, analysis from this institution characteri...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00292-2

    authors: Makeeva V,Vey B,Cook TS,Nagy P,Filice RW,Wang KC,Balthazar P,Harri P,Safdar NM

    更新日期:2020-04-01 00:00:00

  • App Review Series: CTisus iPearls.

    abstract::Thousands of "pearls" or facts related to radiology or imaging are accessible through a categorically organized user interface. Pearls are divided up into anatomical regions, as well as non-organ-specific categories. Information is easily accessible with an ad-free interface matched with full offline capability. User ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-018-0103-x

    authors: Buro J

    更新日期:2018-12-01 00:00:00

  • A Web simulation of medical image reconstruction and processing as an educational tool.

    abstract::Web educational resources integrating interactive simulation tools provide students with an in-depth understanding of the medical imaging process. The aim of this work was the development of a purely Web-based, open access, interactive application, as an ancillary learning tool in graduate and postgraduate medical ima...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-014-9689-9

    authors: Papamichail D,Pantelis E,Papagiannis P,Karaiskos P,Georgiou E

    更新日期:2015-02-01 00:00:00

  • Integrating patient digital photographs with medical imaging examinations.

    abstract::We introduce the concept, benefits, and general architecture for acquiring, storing, and displaying digital photographs along with medical imaging examinations. We also discuss a specific implementation built around an Android-based system for simultaneously acquiring digital photographs along with portable radiograph...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-013-9579-6

    authors: Ramamurthy S,Bhatti P,Arepalli CD,Salama M,Provenzale JM,Tridandapani S

    更新日期:2013-10-01 00:00:00

  • Translating the IHE Teaching File and Clinical Trial Export (TCE) profile document templates into functional DICOM structured report objects.

    abstract::The Integrating the Healthcare Enterprise (IHE) Teaching File and Clinical Trial Export (TCE) integration profile describes a standard workflow for exporting key images from an image manager/archive to a teaching file, clinical trial, or electronic publication application. Two specific digital imaging and communicatio...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-007-9052-5

    authors: Kamauu AW,DuVall SL,Liimatta AP,Wiggins RH 3rd,Avrin DE

    更新日期:2008-12-01 00:00:00

  • Use of a thin-section archive and enterprise 3D software for long-term storage of thin-slice CT data sets.

    abstract::Rapid advances are changing the technology and applications of multidetector computed tomography (CT) scanners. The major increase in data associated with this new technology, however, breaks most commercial picture archiving and communication system (PACS) architectures by preventing them from delivering data in real...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-0925-9

    authors: Meenan C,Daly B,Toland C,Nagy P

    更新日期:2006-01-01 00:00:00

  • A Narrative Review on Clinical Applications of fNIRS.

    abstract::Functional near-infrared spectroscopy (fNIRS) is a relatively new imaging modality in the functional neuroimaging research arena. The fNIRS modality non-invasively investigates the change of blood oxygenation level in the human brain utilizing the transillumination technique. In the last two decades, the interest in t...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-020-00387-1

    authors: Rahman MA,Siddik AB,Ghosh TK,Khanam F,Ahmad M

    更新日期:2020-10-01 00:00:00

  • A study of radiologists viewing multiple computed tomography examinations using an eyetracking device.

    abstract::Understanding the scan patterns radiologists use to view medical images is critical to the design of image viewing devices. In this study, an eyetracker, a device for recording eye and head movement, was used to determine the scan patterns during the interpretation of single and multiple computed tomographic (CT) exam...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168120

    authors: Beard DV,Johnston RE,Toki O,Wilcox C

    更新日期:1990-11-01 00:00:00

  • Computer-aided detection scheme for sentinel lymph nodes in lymphoscintigrams using symmetrical property around mapped injection point.

    abstract::It is difficult to detect sentinel lymph nodes (SLNs) around an injection point of radiopharmaceuticals mapped in lymphoscintigrams. The purpose of this study was to develop a computer-aided detection (CAD) scheme for SLNs by a subtraction technique using the symmetrical property in the mapped injection point. Our dat...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9396-8

    authors: Nakayama R,Hizukuri A,Yamamoto K,Nakako N,Nagasawa N,Takeda K

    更新日期:2012-02-01 00:00:00

  • CT and MR image fusion scheme in nonsubsampled contourlet transform domain.

    abstract::Fusion of CT and MR images allows simultaneous visualization of details of bony anatomy provided by CT image and details of soft tissue anatomy provided by MR image. This helps the radiologist for the precise diagnosis of disease and for more effective interventional treatment procedures. This paper aims at designing ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9664-x

    authors: Ganasala P,Kumar V

    更新日期:2014-06-01 00:00:00

  • Online availability check of teleradiology components.

    abstract::For a region-wide teleradiology network in Germany a vendor-independent Uptime-server concept was defined. The Uptime-server was realized for the availability check and prospective error-detection of the emergency teleradiology servers and clients based on encrypted digital imaging and communication in medicine (DICOM...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-1044-3

    authors: Weisser G,Ruggiero S,Runa A,Düber C,Neff W,Walz M

    更新日期:2007-12-01 00:00:00

  • Picture archiving and communication systems and related developments in Sweden.

    abstract::Large PACS (Picture Archiving and Communication Systems) installations do not yet exist in Sweden, but some hospitals have had experience with limited PACS activities. At present there are four mini PACS installations in radiology departments and about 12 teleradiology systems in use in Sweden. A couple of small Swedi...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168157

    authors: Olsson S

    更新日期:1991-08-01 00:00:00

  • User and system interface issues in the purchase of imaging and information systems.

    abstract::We introduce a set of worksheets to facilitate standardized comparisons among scheduling systems, hospital information systems, radiology information systems, and picture archiving and communication systems vendors. For each system category, we provide worksheets to evaluate the features, performance, installation req...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168605

    authors: Langer S,Wang J

    更新日期:1996-08-01 00:00:00

  • Can paper replace laser film to communicate the results of wrist radiographs in trauma cases? A reproducibility study of the reading of wrist trauma case radiographs on a PACS workstation, laser film, and paper.

    abstract::The main goal of this study was to determine the reproducibility of the reading of wrist trauma case radiographs using three different media: laser film, a picture archiving and communication systems (PACS) workstation, and paper with an optimized layout. The study was conducted retrospectively in 200 consecutive pati...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9613-8

    authors: Teixeira P,Zabel JP,Baumann C,Albizzati S,Coudane H,Winninger D,Blum A

    更新日期:2013-12-01 00:00:00

  • Precise measurement of vertebral bone density using computed tomography without the use of an external reference phantom.

    abstract::Bone density measurement by quantitative computed tomography (QCT) commonly uses an external reference phantom to decrease scan-to-scan and scanner-to-scanner variability. However, the peripheral location of these phantoms and other phantom variables is also responsible for a measurable degradation in accuracy and pre...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168013

    authors: Boden SD,Goodenough DJ,Stockham CD,Jacobs E,Dina T,Allman RM

    更新日期:1989-02-01 00:00:00

  • Feature-Motivated Simplified Adaptive PCNN-Based Medical Image Fusion Algorithm in NSST Domain.

    abstract::Multimodality medical image fusion plays a vital role in diagnosis, treatment planning, and follow-up studies of various diseases. It provides a composite image containing critical information of source images required for better localization and definition of different organs and lesions. In the state-of-the-art imag...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-015-9806-4

    authors: Ganasala P,Kumar V

    更新日期:2016-02-01 00:00:00

  • Network latency and operator performance in teleradiology applications.

    abstract::Teleradiology applications often use an interactive conferencing mode with remote control mouse pointers. When a telephone is used for voice communication, latencies of the data network can create a temporal discrepancy between the position of the mouse pointer and the verbal communication. To assess the effects of th...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168384

    authors: Stahl JN,Tellis W,Huang HK

    更新日期:2000-08-01 00:00:00

  • Towards an Information Infrastructure for Medical Image Sharing.

    abstract::Information infrastructures involve the notion of a shared, open infrastructure, constituting a space where people, organizations, and technical components associate to develop an activity. The current infrastructure for medical image sharing, based on PACS/DICOM technologies, does not constitute an information infras...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00243-x

    authors: Motta GHMB,Araújo DAB,Lucena-Neto JR,Azevedo-Marques PM,Cordeiro SS,Araújo-Neto SA

    更新日期:2020-02-01 00:00:00

  • Combining fast response and low cost in an intensive care unit viewing station.

    abstract::This paper describes a prototype viewing station for the Intensive Care Unit (ICU) that combines a low cost with a fast response for the primary viewing tasks. A single monitor is used together with the possibility to switch to another image on the same screen instantaneously. To reduce the time for image retrieval an...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168429

    authors: Bellon E,Houtput W,Bijnens B,Suetens P,Marchal G,Lauwers P

    更新日期:1994-05-01 00:00:00

  • Full-Dose PET Image Estimation from Low-Dose PET Image Using Deep Learning: a Pilot Study.

    abstract::Positron emission tomography (PET) imaging is an effective tool used in determining disease stage and lesion malignancy; however, radiation exposure to patients and technicians during PET scans continues to draw concern. One way to minimize radiation exposure is to reduce the dose of radioactive tracer administered in...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0150-3

    authors: Kaplan S,Zhu YM

    更新日期:2019-10-01 00:00:00

  • Online Radiology Reporting with Peer Review as a Learning and Feedback Tool in Radiology; Implementation, Validity, and Student Impressions.

    abstract::Communicating radiological reports to peers has pedagogical value. Students may be uneasy with the process due to a lack of communication and peer review skills or to their failure to see value in the process. We describe a communication exercise with peer review in an undergraduate veterinary radiology course. The co...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-016-9905-x

    authors: McEvoy FJ,Shen NW,Nielsen DH,Buelund LE,Holm P

    更新日期:2017-02-01 00:00:00

  • Toward Automatic Detection of Radiation-Induced Cerebral Microbleeds Using a 3D Deep Residual Network.

    abstract::Cerebral microbleeds, which are small focal hemorrhages in the brain that are prevalent in many diseases, are gaining increasing attention due to their potential as surrogate markers of disease burden, clinical outcomes, and delayed effects of therapy. Manual detection is laborious and automatic detection and labeling...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0146-z

    authors: Chen Y,Villanueva-Meyer JE,Morrison MA,Lupo JM

    更新日期:2019-10-01 00:00:00

  • A Decision-Support Tool for Renal Mass Classification.

    abstract::We investigate the viability of statistical relational machine learning algorithms for the task of identifying malignancy of renal masses using radiomics-based imaging features. Features characterizing the texture, signal intensity, and other relevant metrics of the renal mass were extracted from multiphase contrast-e...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0100-0

    authors: Kunapuli G,Varghese BA,Ganapathy P,Desai B,Cen S,Aron M,Gill I,Duddalwar V

    更新日期:2018-12-01 00:00:00

  • User questionnaire to evaluate the radiological workspace.

    abstract::Over the past few years, an increase in digitalization of radiology departments can be seen, which has a large impact on the work of the radiologists. This impact is not only demonstrated by the increased use of digital images but also by changing demands on the whole reading environment. In this study, we evaluated t...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-0629-1

    authors: van Ooijen PM,Koesoema AP,Oudkerk M

    更新日期:2006-01-01 00:00:00

  • Classification of breast masses using selected shape, edge-sharpness, and texture features with linear and kernel-based classifiers.

    abstract::Breast masses due to benign disease and malignant tumors related to breast cancer differ in terms of shape, edge-sharpness, and texture characteristics. In this study, we evaluate a set of 22 features including 5 shape factors, 3 edge-sharpness measures, and 14 texture features computed from 111 regions in mammograms,...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-007-9102-z

    authors: Mu T,Nandi AK,Rangayyan RM

    更新日期:2008-06-01 00:00:00

  • Impact of digital radiography on clinical workflow and patient satisfaction.

    abstract::Compared to traditional film radiography, digital radiography is believed to improve workflow and patient throughput. Digital radiography permits the technologist to immediately view the quality of the film directly at the modality. Additional workflow improvements, therefore, should be achieved with the integration o...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167662

    authors: Dackiewicz D,Bergsneider C,Piraino D

    更新日期:2000-05-01 00:00:00

  • An effective approach of lesion segmentation within the breast ultrasound image based on the cellular automata principle.

    abstract::In this paper, a novel lesion segmentation within breast ultrasound (BUS) image based on the cellular automata principle is proposed. Its energy transition function is formulated based on global image information difference and local image information difference using different energy transfer strategies. First, an en...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9450-6

    authors: Liu Y,Cheng HD,Huang J,Zhang Y,Tang X

    更新日期:2012-10-01 00:00:00

  • Effect of viewing angle on luminance and contrast for a five-million-pixel monochrome display and a nine-million-pixel color liquid crystal display.

    abstract::Digital imaging systems used in radiology rely on electronic display devices to present images to human observers. Active-matrix liquid crystal displays (AMLCDs) continue to improve and are beginning to be considered for diagnostic image display. In spite of recent progress, AMLCDs are characterized by a change in lum...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-004-1021-7

    authors: Fifadara DH,Averbukh A,Channin DS,Badano A

    更新日期:2004-12-01 00:00:00