Integrating patient digital photographs with medical imaging examinations.

Abstract:

:We introduce the concept, benefits, and general architecture for acquiring, storing, and displaying digital photographs along with medical imaging examinations. We also discuss a specific implementation built around an Android-based system for simultaneously acquiring digital photographs along with portable radiographs. By an innovative application of radiofrequency identification technology to radiographic cassettes, the system is able to maintain a tight relationship between these photographs and the radiographs within the picture archiving and communications system (PACS) environment. We provide a cost analysis demonstrating the economic feasibility of this technology. Since our architecture naturally integrates with patient identification methods, we also address patient privacy issues.

journal_name

J Digit Imaging

authors

Ramamurthy S,Bhatti P,Arepalli CD,Salama M,Provenzale JM,Tridandapani S

doi

10.1007/s10278-013-9579-6

subject

Has Abstract

pub_date

2013-10-01 00:00:00

pages

875-85

issue

5

eissn

0897-1889

issn

1618-727X

journal_volume

26

pub_type

杂志文章,评审
  • A method for computing general sacroiliac screw corridors based on CT scans of the pelvis.

    abstract::Sacroiliac (SI) joint dislocations and sacral fractures of the pelvis can be stabilized by SI screws; however, screw insertion into a sacral isthmus region is risky for the adjacent neurovascular structures. Therefore, shape analyses of general SI screw corridors or safety zones are of great surgical interest; however...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-010-9327-0

    authors: Noser H,Radetzki F,Stock K,Mendel T

    更新日期:2011-08-01 00:00:00

  • Novel computer-aided diagnosis algorithms on ultrasound image: effects on solid breast masses discrimination.

    abstract::The objective of this study is to retrospectively investigate whether using the newly developed algorithms would improve radiologists' accuracy for discriminating malignant masses from benign ones on ultrasonographic (US) images. Five radiologists blinded to the histological results and clinical history independently ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-009-9245-1

    authors: Wang Y,Wang H,Guo Y,Ning C,Liu B,Cheng HD,Tian J

    更新日期:2010-10-01 00:00:00

  • Towards a repository for standardized medical image and signal case data annotated with ground truth.

    abstract::Validation of medical signal and image processing systems requires quality-assured, representative and generally acknowledged databases accompanied by appropriate reference (ground truth) and clinical metadata, which are composed laboriously for each project and are not shared with the scientific community. In our vis...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9428-4

    authors: Deserno TM,Welter P,Horsch A

    更新日期:2012-04-01 00:00:00

  • Early lung cancer detection using the self-evaluation scoring questionnaire and chest digital radiography: a 3-year follow-up study in China.

    abstract::The standard definition of high-risk individuals for lung cancer was not uniform and the value of chest digital radiography (DR) in lung cancer screening was still unproven. The aim of this study was to assess whether the original questionnaire named as "Self-evaluation Scoring Questionnaire for High-risk Individuals ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9468-4

    authors: Chen B,Wang Y,Cao H,Liu D,Zhang S,Gao J,Yu J,Huang Y,Li W

    更新日期:2013-02-01 00:00:00

  • Segmentation by evolution for visualization of the lower extremity of the Visible Man.

    abstract::Medical image segmentation is the crucial process for three-dimensional (3D) modeling. Many studies have claimed to suggest more accurate ways of segmentation. However, such research seems to have the drawback that it works against the parsimony principle. These methods have to resegment the regions of interest (ROIs)...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03190342

    authors: Lee JW,Lee J,Kim D,Kim JH,Park KS,Kang HS

    更新日期:2001-06-01 00:00:00

  • Sophisticated hospital information system/radiology information system/picture archiving and communications system (PACS) integration in a large-scale traumatology PACS.

    abstract::Picture archiving and communications system (PACS) in the context of an outpatient trauma care center asks for a high level of interaction between information systems to guarantee rapid image acquisition and distribution to the surgeon. During installation of the Innsbruck PACS, special aspects of traumatology had to ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168769

    authors: Peer S,Vogl R,Peer R,Jaschke W

    更新日期:1999-05-01 00:00:00

  • Enhancement of storage phosphor plate images: a C-language program.

    abstract::A C-language software program has been developed for emulating the image enhancement processing of a storage phosphor plate system. This software has been implemented on a VAX 3400 computer. There are 2,100 lines of C-language code in the program. There are seven parameters used to specify the degree of enhancement. T...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167825

    authors: Templeton AW,Wetzel LH,Cook LT,Harrison LA,Eckard DA,Anderson WH,Hensley KS

    更新日期:1992-02-01 00:00:00

  • Stereoscopic interpretation of low-dose breast tomosynthesis projection images.

    abstract::The purpose of this study was to evaluate stereoscopic perception of low-dose breast tomosynthesis projection images. In this Institutional Review Board exempt study, craniocaudal breast tomosynthesis cases (N = 47), consisting of 23 biopsy-proven malignant mass cases and 24 normal cases, were retrospectively reviewed...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9648-x

    authors: Muralidhar GS,Markey MK,Bovik AC,Haygood TM,Stephens TW,Geiser WR,Garg N,Adrada BE,Dogan BE,Carkaci S,Khisty R,Whitman GJ

    更新日期:2014-04-01 00:00:00

  • Ruler Based Automatic C-Arm Image Stitching Without Overlapping Constraint.

    abstract::In this paper, we propose a new method for stitching multiple fluoroscopic images taken by a C-arm instrument. We employ an X-ray radiolucent ruler with numbered graduations while acquiring the images, and the image stitching is based on detecting and matching ruler parts in the images to the corresponding parts of a ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-014-9763-3

    authors: Chen C,Kojcev R,Haschtmann D,Fekete T,Nolte L,Zheng G

    更新日期:2015-08-01 00:00:00

  • Comparison of algorithms to enhance spicules of spiculated masses on mammography.

    abstract::We have developed an algorithm for enhancement of spicules of spiculated masses, which uses the discrete radon transform. Previously, we employed a commonly used method to compute the discrete radon transform, which we refer to as the DRT. Recently, a new, more exact method to compute the discrete radon transform was ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-007-9015-x

    authors: Sampat MP,Whitman GJ,Bovik AC,Markey MK

    更新日期:2008-03-01 00:00:00

  • Optimizing technology development and adoption in medical imaging using the principles of innovation diffusion, part II: practical applications.

    abstract::Successful adoption of new technology development can be accentuated by learning and applying the scientific principles of innovation diffusion. This is of particular importance to areas within the medical imaging practice which have lagged in innovation; perhaps, the most notable of which is reporting which has remai...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-011-9409-7

    authors: Reiner BI

    更新日期:2012-02-01 00:00:00

  • MRIdb: medical image management for biobank research.

    abstract::Clinical picture archiving and communications systems provide convenient, efficient access to digital medical images from multiple modalities but can prove challenging to deploy, configure and use. MRIdb is a self-contained image database, particularly suited to the storage and management of magnetic resonance imaging...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9604-9

    authors: Woodbridge M,Fagiolo G,O'Regan DP

    更新日期:2013-10-01 00:00:00

  • User questionnaire to evaluate the radiological workspace.

    abstract::Over the past few years, an increase in digitalization of radiology departments can be seen, which has a large impact on the work of the radiologists. This impact is not only demonstrated by the increased use of digital images but also by changing demands on the whole reading environment. In this study, we evaluated t...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-0629-1

    authors: van Ooijen PM,Koesoema AP,Oudkerk M

    更新日期:2006-01-01 00:00:00

  • Towards Portable Large-Scale Image Processing with High-Performance Computing.

    abstract::High-throughput, large-scale medical image computing demands tight integration of high-performance computing (HPC) infrastructure for data storage, job distribution, and image processing. The Vanderbilt University Institute for Imaging Science (VUIIS) Center for Computational Imaging (CCI) has constructed a large-scal...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-018-0080-0

    authors: Huo Y,Blaber J,Damon SM,Boyd BD,Bao S,Parvathaneni P,Noguera CB,Chaganti S,Nath V,Greer JM,Lyu I,French WR,Newton AT,Rogers BP,Landman BA

    更新日期:2018-06-01 00:00:00

  • Analog to digital workflow improvement: a quantitative study.

    abstract::This study tracked a radiology department's conversion from utilization of a Kodak Amber analog system to a Kodak DirectView DR 5100 digital system. Through the use of ProModel Optimization Suite, a workflow simulation software package, significant quantitative information was derived from workflow process data measur...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-0770-x

    authors: Wideman C,Gallet J

    更新日期:2006-01-01 00:00:00

  • Environmental designs for reading from imaging work stations: ergonomic and architectural features.

    abstract::Despite the rapid progress made in the electronic design of imaging work stations for medicine, much less effort has gone into the design of environments in which such systems will be used. Based on studies of radiologist film reading sessions, considerable time will be spent working at such viewing systems. If the ro...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168035

    authors: Horii SC,Horii HN,Mun SK,Benson HR,Zeman RK

    更新日期:1989-08-01 00:00:00

  • Integrating an Ontology of Radiology Differential Diagnosis with ICD-10-CM, RadLex, and SNOMED CT.

    abstract::An ontology offers a human-readable and machine-computable representation of the concepts in a domain and the relationships among them. Mappings between ontologies enable the reuse and interoperability of biomedical knowledge. We sought to map concepts of the Radiology Gamuts Ontology (RGO), an ontology that links dis...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00186-3

    authors: Filice RW,Kahn CE Jr

    更新日期:2019-04-01 00:00:00

  • Estimation of Radiation Dose in CT Based on Projection Data.

    abstract::Managing and optimizing radiation dose has become a core problem for the CT community. As a fundamental step for dose optimization, accurate and computationally efficient dose estimates are crucial. The purpose of this study was to devise a computationally efficient projection-based dose metric. The absorbed energy an...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-016-9869-x

    authors: Tian X,Yin Z,De Man B,Samei E

    更新日期:2016-10-01 00:00:00

  • Volumetric Assessment of Pediatric Vascular Malformations Using a Rapid, Hand-Held Three-Dimensional Imaging System.

    abstract::The effect of percutaneous, surgical, and medical therapies for vascular malformations (VMs) is often difficult to quantify volumetrically using cross-sectional imaging. Volumetric measurement is often estimated with serial, expensive MRI examinations which may require sedation or anesthesia. We aim to explore whether...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00183-6

    authors: Speir EJ,Matthew Hawkins C,Weiler MJ,Briones M,Swerdlin R,Park S,Brandon Dixon J

    更新日期:2019-04-01 00:00:00

  • Medical applications of digital image morphing.

    abstract::The authors present a unique medical technical application for illustrating the success and/or failure of the physiological healing process as a dynamically morphed video. Two examples used in this report include the healing of a severely fractured humerus from an explosion in Iraq and the other of dramatic tissue des...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-1050-5

    authors: Penska K,Folio L,Bunger R

    更新日期:2007-09-01 00:00:00

  • Of Mice and Roentgen: Radiologist Satisfaction with a Non-conventional 13-Button Mouse-One Institution's Experience.

    abstract::Increasing radiologic exam volume and complexity necessitates leveraging advanced hardware solutions to optimize workflow efficiency. We evaluated radiologist satisfaction of a programmable 13-button non-conventional mouse compared to a conventional three-button mouse in daily interpretation workflow following a brief...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0094-7

    authors: Denton K,Haider I,Hill J,Hunt SL,Ash R

    更新日期:2018-12-01 00:00:00

  • Detection of breast cancer with a computer-aided detection applied to full-field digital mammography.

    abstract::A study was conducted to evaluate the sensitivity of computer-aided detection (CAD) with full-field digital mammography in detection of breast cancer, based on mammographic appearance and histopathology. Retrospectively, CAD sensitivity was assessed in total group of 152 cases for subgroups based on breast density, ma...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9564-5

    authors: Murakami R,Kumita S,Tani H,Yoshida T,Sugizaki K,Kuwako T,Kiriyama T,Hakozaki K,Okazaki E,Yanagihara K,Iida S,Haga S,Tsuchiya S

    更新日期:2013-08-01 00:00:00

  • Translating the IHE Teaching File and Clinical Trial Export (TCE) profile document templates into functional DICOM structured report objects.

    abstract::The Integrating the Healthcare Enterprise (IHE) Teaching File and Clinical Trial Export (TCE) integration profile describes a standard workflow for exporting key images from an image manager/archive to a teaching file, clinical trial, or electronic publication application. Two specific digital imaging and communicatio...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-007-9052-5

    authors: Kamauu AW,DuVall SL,Liimatta AP,Wiggins RH 3rd,Avrin DE

    更新日期:2008-12-01 00:00:00

  • Artifacts found during quality assurance testing of computed radiography and digital radiography detectors.

    abstract::A series of artifact images, obtained over 5 years of performance testing, of both computed radiography (CR) and integrated digital radiographic X-ray imaging detectors are presented. The images presented are all either flat field or test object images and show artifacts previously either undescribed in the existing l...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-008-9109-0

    authors: Honey ID,Mackenzie A

    更新日期:2009-08-01 00:00:00

  • Computed radiography: user-programmable features and capabilities.

    abstract::Digital or computed radiography (CR) using photostimulable storage phosphor plate technology is becoming increasingly popular in certain clinical applications, such as bedside radiography, where it possesses clear advantages over conventional screen-film imaging. The majority of CR systems in clinical use have been ma...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168504

    authors: Gingold EL,Tucker DM,Barnes GT

    更新日期:1994-08-01 00:00:00

  • A novel medical image quality index.

    abstract::A novel medical image quality index using grey relational coefficient calculation is proposed in this study. Three medical modalities, DR, CT and MRI, using 30 or 60 images with a total of 120 images used for experimentation. These images were first compressed at ten different compression ratios (10 ∼ 100) using a med...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-010-9353-y

    authors: Lin SC,Lin YC,Feng WS,Wu JM,Chen TJ

    更新日期:2011-10-01 00:00:00

  • Precise measurement of vertebral bone density using computed tomography without the use of an external reference phantom.

    abstract::Bone density measurement by quantitative computed tomography (QCT) commonly uses an external reference phantom to decrease scan-to-scan and scanner-to-scanner variability. However, the peripheral location of these phantoms and other phantom variables is also responsible for a measurable degradation in accuracy and pre...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168013

    authors: Boden SD,Goodenough DJ,Stockham CD,Jacobs E,Dina T,Allman RM

    更新日期:1989-02-01 00:00:00

  • Medical image file formats.

    abstract::Image file format is often a confusing aspect for someone wishing to process medical images. This article presents a demystifying overview of the major file formats currently used in medical imaging: Analyze, Neuroimaging Informatics Technology Initiative (Nifti), Minc, and Digital Imaging and Communications in Medici...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-013-9657-9

    authors: Larobina M,Murino L

    更新日期:2014-04-01 00:00:00

  • A Web simulation of medical image reconstruction and processing as an educational tool.

    abstract::Web educational resources integrating interactive simulation tools provide students with an in-depth understanding of the medical imaging process. The aim of this work was the development of a purely Web-based, open access, interactive application, as an ancillary learning tool in graduate and postgraduate medical ima...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-014-9689-9

    authors: Papamichail D,Pantelis E,Papagiannis P,Karaiskos P,Georgiou E

    更新日期:2015-02-01 00:00:00

  • Deep Convolutional Neural Networks for Endotracheal Tube Position and X-ray Image Classification: Challenges and Opportunities.

    abstract::The goal of this study is to evaluate the efficacy of deep convolutional neural networks (DCNNs) in differentiating subtle, intermediate, and more obvious image differences in radiography. Three different datasets were created, which included presence/absence of the endotracheal (ET) tube (n = 300), low/normal positio...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-017-9980-7

    authors: Lakhani P

    更新日期:2017-08-01 00:00:00