Medical image file formats.

Abstract:

:Image file format is often a confusing aspect for someone wishing to process medical images. This article presents a demystifying overview of the major file formats currently used in medical imaging: Analyze, Neuroimaging Informatics Technology Initiative (Nifti), Minc, and Digital Imaging and Communications in Medicine (Dicom). Concepts common to all file formats, such as pixel depth, photometric interpretation, metadata, and pixel data, are first presented. Then, the characteristics and strengths of the various formats are discussed. The review concludes with some predictive considerations about the future trends in medical image file formats.

journal_name

J Digit Imaging

authors

Larobina M,Murino L

doi

10.1007/s10278-013-9657-9

subject

Has Abstract

pub_date

2014-04-01 00:00:00

pages

200-6

issue

2

eissn

0897-1889

issn

1618-727X

journal_volume

27

pub_type

杂志文章,评审
  • Extraction of microcalcifications in digital mammograms using regional watershed.

    abstract::In this report, a novel technique is proposed for computer-aided automatic extraction of microcalcifications in a digital mammogram. First, the microcalcifications are detected by morphological filtering, followed by entropy-based thresholding. Next, the microcalcifications are segmented by computing regional watershe...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167642

    authors: Bhajammanavar VM,Keong KC,Krishnan SM

    更新日期:2000-05-01 00:00:00

  • Application of temporal subtraction for detection of interval changes on chest radiographs: improvement of subtraction images using automated initial image matching.

    abstract::The authors developed a temporal subtraction scheme based on a nonlinear geometric warping technique to assist radiologists in the detection of interval changes in chest radiographs obtained on different occasions. The performance of the current temporal subtraction scheme is reasonably good; however, severe misregist...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168846

    authors: Ishida T,Ashizawa K,Engelmann R,Katsuragawa S,MacMahon H,Doi K

    更新日期:1999-05-01 00:00:00

  • What is a wiki, and how can it be used in resident education?

    abstract::Training as a radiology resident is a complex task. Residents frequently encounter multiple hospital systems, each with unique workflow patterns and heterogenous information systems. We identified an opportunity to ease some of the resulting anxiety and frustration by centralizing high-quality resources using a wiki. ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-010-9292-7

    authors: Kohli MD,Bradshaw JK

    更新日期:2011-02-01 00:00:00

  • A novel medical image quality index.

    abstract::A novel medical image quality index using grey relational coefficient calculation is proposed in this study. Three medical modalities, DR, CT and MRI, using 30 or 60 images with a total of 120 images used for experimentation. These images were first compressed at ten different compression ratios (10 ∼ 100) using a med...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-010-9353-y

    authors: Lin SC,Lin YC,Feng WS,Wu JM,Chen TJ

    更新日期:2011-10-01 00:00:00

  • Computed radiography in pediatrics.

    abstract::Computed radiography (CR) has various advantages such as dynamic range. Diagnostic accuracy with CR using reduced radiation dose is considered comparable with that of conventional film-screen radiography in diagnosing apparent chest abnormalities. In addition to reducing the radiation dose, delineation of the various ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168076

    authors: Aoki K

    更新日期:1995-02-01 00:00:00

  • Automated routing of DICOM CT, MR, and CR images: solving the pitfalls of vendor-specific DICOM implementations.

    abstract::This paper details our experience in developing and implementing an automated DICOM Image Router. This workstation serves as a gateway between image acquisition devices and image display and storage devices. Images are checked for demographic input errors and data format inconsistencies between the source and destinat...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168283

    authors: Junck KL,McEachern M,Grandhi S,Lewey G

    更新日期:1998-08-01 00:00:00

  • A heuristic approach to automated nipple detection in digital mammograms.

    abstract::In this paper, a heuristic approach to automated nipple detection in digital mammograms is presented. A multithresholding algorithm is first applied to segment the mammogram and separate the breast region from the background region. Next, the problem is considered separately for craniocaudal (CC) and mediolateral-obli...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9575-x

    authors: Jas M,Mukhopadhyay S,Chakraborty J,Sadhu A,Khandelwal N

    更新日期:2013-10-01 00:00:00

  • PDA-phone-based instant transmission of radiological images over a CDMA network by combining the PACS screen with a Bluetooth-interfaced local wireless link.

    abstract::Remote teleconsultation by specialists is important for timely, correct, and specialized emergency surgical and medical decision making. In this paper, we designed a new personal digital assistant (PDA)-phone-based emergency teleradiology system by combining cellular communication with Bluetooth-interfaced local wirel...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-007-9002-2

    authors: Kim DK,Yoo SK,Park JJ,Kim SH

    更新日期:2007-06-01 00:00:00

  • Medicolegal considerations in the implementation of a PACS web application.

    abstract::The goal of this study is to provide the clinical end users of an enterprisewide picture archiving and communication system/Web application with a thorough understanding of the application and education to maintain patient privacy and protection. ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-002-5101-2

    authors: Cook K

    更新日期:2002-01-01 00:00:00

  • Ruler Based Automatic C-Arm Image Stitching Without Overlapping Constraint.

    abstract::In this paper, we propose a new method for stitching multiple fluoroscopic images taken by a C-arm instrument. We employ an X-ray radiolucent ruler with numbered graduations while acquiring the images, and the image stitching is based on detecting and matching ruler parts in the images to the corresponding parts of a ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-014-9763-3

    authors: Chen C,Kojcev R,Haschtmann D,Fekete T,Nolte L,Zheng G

    更新日期:2015-08-01 00:00:00

  • A Decision-Support Tool for Renal Mass Classification.

    abstract::We investigate the viability of statistical relational machine learning algorithms for the task of identifying malignancy of renal masses using radiomics-based imaging features. Features characterizing the texture, signal intensity, and other relevant metrics of the renal mass were extracted from multiphase contrast-e...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0100-0

    authors: Kunapuli G,Varghese BA,Ganapathy P,Desai B,Cen S,Aron M,Gill I,Duddalwar V

    更新日期:2018-12-01 00:00:00

  • Classification of breast masses using selected shape, edge-sharpness, and texture features with linear and kernel-based classifiers.

    abstract::Breast masses due to benign disease and malignant tumors related to breast cancer differ in terms of shape, edge-sharpness, and texture characteristics. In this study, we evaluate a set of 22 features including 5 shape factors, 3 edge-sharpness measures, and 14 texture features computed from 111 regions in mammograms,...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-007-9102-z

    authors: Mu T,Nandi AK,Rangayyan RM

    更新日期:2008-06-01 00:00:00

  • Development of a research dedicated archival system (TARAS) in a university hospital.

    abstract::Recent healthcare policies have influenced the manner in which patient data is handled in research projects, and the regulations concerning protected health information have become significantly tighter. Thus, new procedures are needed to facilitate research while protecting the confidentiality of patient data and ens...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-010-9350-1

    authors: Rajala T,Savio S,Penttinen J,Dastidar P,Kähönen M,Eskola H,Miettunen R,Turjanmaa V,Järvenpää R

    更新日期:2011-10-01 00:00:00

  • Effect of viewing angle on luminance and contrast for a five-million-pixel monochrome display and a nine-million-pixel color liquid crystal display.

    abstract::Digital imaging systems used in radiology rely on electronic display devices to present images to human observers. Active-matrix liquid crystal displays (AMLCDs) continue to improve and are beginning to be considered for diagnostic image display. In spite of recent progress, AMLCDs are characterized by a change in lum...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-004-1021-7

    authors: Fifadara DH,Averbukh A,Channin DS,Badano A

    更新日期:2004-12-01 00:00:00

  • Enhancement of storage phosphor plate images: a C-language program.

    abstract::A C-language software program has been developed for emulating the image enhancement processing of a storage phosphor plate system. This software has been implemented on a VAX 3400 computer. There are 2,100 lines of C-language code in the program. There are seven parameters used to specify the degree of enhancement. T...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167825

    authors: Templeton AW,Wetzel LH,Cook LT,Harrison LA,Eckard DA,Anderson WH,Hensley KS

    更新日期:1992-02-01 00:00:00

  • Thresholding histogram equalization.

    abstract::The drawbacks of adaptive histogram equalization techniques are the loss of definition on the edges of the object and overenhancement of noise in the images. These drawbacks can be avoided if the noise is excluded in the equalization transformation function computation. A method has been developed to separate the hist...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-001-0103-z

    authors: Chuang KS,Chen S,Hwang IM

    更新日期:2001-12-01 00:00:00

  • An algorithm for automatic segmentation and classification of magnetic resonance brain images.

    abstract::In this article, we describe the development and validation of an automatic algorithm to segment brain from extracranial tissues, and to classify intracranial tissues as cerebrospinal fluid (CSF), gray matter (GM), white matter (WM) or pathology. T1 weighted spin echo, dual echo fast spin echo (T2 weighted and proton ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168729

    authors: Erickson BJ,Avula RT

    更新日期:1998-05-01 00:00:00

  • A breast density index for digital mammograms based on radiologists' ranking.

    abstract::The purpose of this study was to develop and evaluate a computerized method of calculating a breast density index (BDI) from digitized mammograms that was designed specifically to model radiologists' perception of breast density. A set of 153 pairs of digitized mammograms (cranio-caudal, CC, and mediolateral oblique, ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168733

    authors: Boone JM,Lindfors KK,Beatty CS,Seibert JA

    更新日期:1998-08-01 00:00:00

  • An artificial immune-activated neural network applied to brain 3D MRI segmentation.

    abstract::In this paper, a new neural network model inspired by the biological immune system functions is presented. The model, termed Artificial Immune-Activated Neural Network (AIANN), extracts classification knowledge from a training data set, which is then used to classify input patterns or vectors. The AIANN is based on a ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-007-9081-0

    authors: Younis A,Ibrahim M,Kabuka M,John N

    更新日期:2008-10-01 00:00:00

  • A Novel Texture-Quantization-Based Reversible Multiple Watermarking Scheme Applied to Health Information System.

    abstract::The recent innovations in information and communication technologies have appreciably changed the panorama of health information system (HIS). These advances provide new means to process, handle, and share medical images and also augment the medical image security issues in terms of confidentiality, reliability, and i...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-017-0024-0

    authors: Turuk M,Dhande A

    更新日期:2018-04-01 00:00:00

  • Stereoscopic interpretation of low-dose breast tomosynthesis projection images.

    abstract::The purpose of this study was to evaluate stereoscopic perception of low-dose breast tomosynthesis projection images. In this Institutional Review Board exempt study, craniocaudal breast tomosynthesis cases (N = 47), consisting of 23 biopsy-proven malignant mass cases and 24 normal cases, were retrospectively reviewed...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9648-x

    authors: Muralidhar GS,Markey MK,Bovik AC,Haygood TM,Stephens TW,Geiser WR,Garg N,Adrada BE,Dogan BE,Carkaci S,Khisty R,Whitman GJ

    更新日期:2014-04-01 00:00:00

  • The impact of networking on image acquisition system design.

    abstract::Widespread integration of networking technology will change the hospital imaging environment, making computational, archiving, and film production services available to network-connected modalities. This change will be reflected in the designs of the image acquisition modalities themselves. A view of the future is pre...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168154

    authors: Perry JH

    更新日期:1991-11-01 00:00:00

  • SCAR R&D Symposium 2003: comparing the efficacy of 5-MP CRT versus 3-MP LCD in the evaluation of interstitial lung disease.

    abstract::The efficacy of two medical-grade, self-calibrating, gray scale displays were compared with regard to impact on sensitivity and specificity for the detection of interstitial lung disease (ILD) on computed radiographs (CR). The displays were a 5-megapixel (MP) cathode ray tube (CRT) device and a 3-MP liquid crystal dis...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-004-1013-7

    authors: Langer S,Bartholmai B,Fetterly K,Harmsen S,Ryan W,Erickson B,Andriole K,Carrino J

    更新日期:2004-09-01 00:00:00

  • A new family of distance functions for perceptual similarity retrieval of medical images.

    abstract::A long-standing challenge of content-based image retrieval (CBIR) systems is the definition of a suitable distance function to measure the similarity between images in an application context which complies with the human perception of similarity. In this paper, we present a new family of distance functions, called att...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-007-9084-x

    authors: Felipe JC,Traina C Jr,Traina AJ

    更新日期:2009-04-01 00:00:00

  • A Feasibility Study of Smartphone-Based Telesonography for Evaluating Cardiac Dynamic Function and Diagnosing Acute Appendicitis with Control of the Image Quality of the Transmitted Videos.

    abstract::Our aim was to prove the feasibility of the remote interpretation of real-time transmitted ultrasound videos of dynamic and static organs using a smartphone with control of the image quality given a limited internet connection speed. For this study, 100 cases of echocardiography videos (dynamic organ)-50 with an eject...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-015-9849-6

    authors: Kim C,Cha H,Kang BS,Choi HJ,Lim TH,Oh J

    更新日期:2016-06-01 00:00:00

  • Variability of semiautomated lung nodule volumetry on ultralow-dose CT: comparison with nodule volumetry on standard-dose CT.

    abstract::The study investigates the effect of a substantial dose reduction on the variability of lung nodule volume measurements by assessing and comparing nodule volumes using a dedicated semiautomated segmentation software on ultralow-dose computed tomography (ULD-CT) and standard-dose computed tomography (SD-CT) data. In 20...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-008-9157-5

    authors: Hein PA,Romano VC,Rogalla P,Klessen C,Lembcke A,Bornemann L,Dicken V,Hamm B,Bauknecht HC

    更新日期:2010-02-01 00:00:00

  • Classification of hypervascular liver lesions based on hepatic artery and portal vein blood supply coefficients calculated from triphasic CT scans.

    abstract::Perfusion CT of the liver typically involves scanning the liver at least 20 times, resulting in a large radiation dose. We developed and validated a simplified model of tumor blood supply that can be applied to standard triphasic scans and evaluated whether this can be used to distinguish benign and malignant liver le...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-014-9725-9

    authors: Boas FE,Kamaya A,Do B,Desser TS,Beaulieu CF,Vasanawala SS,Hwang GL,Sze DY

    更新日期:2015-04-01 00:00:00

  • Integrating patient digital photographs with medical imaging examinations.

    abstract::We introduce the concept, benefits, and general architecture for acquiring, storing, and displaying digital photographs along with medical imaging examinations. We also discuss a specific implementation built around an Android-based system for simultaneously acquiring digital photographs along with portable radiograph...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-013-9579-6

    authors: Ramamurthy S,Bhatti P,Arepalli CD,Salama M,Provenzale JM,Tridandapani S

    更新日期:2013-10-01 00:00:00

  • Solution for nonuniformities and spatial noise in medical LCD displays by using pixel-based correction.

    abstract::Liquid crystal displays (LCD) are rapidly replacing cathode ray tube displays (CRT) for medical imaging. LCD technology has improved significantly in the last few years and has important advantages over CRT. However, there are still some aspects of LCD that raise questions as to the usefulness of liquid crystal displa...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-005-2939-0

    authors: Kimpe T,Xthona A,Matthijs P,De Paepe L

    更新日期:2005-09-01 00:00:00

  • Prostate tissue texture feature extraction for suspicious regions identification on TRUS images.

    abstract::In this work, two different approaches are proposed for region of interest (ROI) segmentation using transrectal ultrasound (TRUS) images. The two methods aim to extract informative features that are able to characterize suspicious regions in the TRUS images. Both proposed methods are based on multi-resolution analysis...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-008-9124-1

    authors: Mohamed SS,Li J,Salama MM,Freeman G

    更新日期:2009-10-01 00:00:00