Comparison of algorithms to enhance spicules of spiculated masses on mammography.

Abstract:

:We have developed an algorithm for enhancement of spicules of spiculated masses, which uses the discrete radon transform. Previously, we employed a commonly used method to compute the discrete radon transform, which we refer to as the DRT. Recently, a new, more exact method to compute the discrete radon transform was developed by Averbuch et al, which is called the fast slant stack (FSS) method. Our hypothesis was that this new formulation would help to improve our enhancement algorithm. To test this idea, we conducted multiple two-alternative-forced-choice observer studies and found that most observers preferred the enhanced images generated with the FSS method.

journal_name

J Digit Imaging

authors

Sampat MP,Whitman GJ,Bovik AC,Markey MK

doi

10.1007/s10278-007-9015-x

subject

Has Abstract

pub_date

2008-03-01 00:00:00

pages

9-17

issue

1

eissn

0897-1889

issn

1618-727X

journal_volume

21

pub_type

杂志文章
  • Clinical evaluation of irreversible data compression for computed radiography of the chest.

    abstract::Efficient data compression is essential for practical daily operation of computed radiography (CR) systems. In this study the clinical applicability of type III irreversible high data compression using an FCR 9501 chest unit (Fuji Photo Film, Tokyo, Japan) was evaluated. Sixty-eight normal and 93 various abnormal case...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03178080

    authors: Egashira K,Nakata H,Watanabe H,Uchida K,Nakamura K,Ishino Y,Horino K,Yoshikawa R

    更新日期:1998-11-01 00:00:00

  • Extraction of microcalcifications in digital mammograms using regional watershed.

    abstract::In this report, a novel technique is proposed for computer-aided automatic extraction of microcalcifications in a digital mammogram. First, the microcalcifications are detected by morphological filtering, followed by entropy-based thresholding. Next, the microcalcifications are segmented by computing regional watershe...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167642

    authors: Bhajammanavar VM,Keong KC,Krishnan SM

    更新日期:2000-05-01 00:00:00

  • An ROC study of chest radiographs: 2K Versus 4K high-resolution soft-copy images.

    abstract::Computed radiography of chest with a 4K image array was recently introduced. We performed a multiobserver study to compare the diagnostic accuracy of 2K (standard) and 4K (high quality) chest radiographs displayed on a 5-mega-pixel monitor (2K monitor). One hundred cases of posteroanterior chest radiographs (a total o...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-1048-z

    authors: Kim SY,Hwang YJ,Han YH,Seo JW,Lee JY,Kim YH,Cha SJ,Hur G,Lee SS

    更新日期:2007-12-01 00:00:00

  • Variability of semiautomated lung nodule volumetry on ultralow-dose CT: comparison with nodule volumetry on standard-dose CT.

    abstract::The study investigates the effect of a substantial dose reduction on the variability of lung nodule volume measurements by assessing and comparing nodule volumes using a dedicated semiautomated segmentation software on ultralow-dose computed tomography (ULD-CT) and standard-dose computed tomography (SD-CT) data. In 20...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-008-9157-5

    authors: Hein PA,Romano VC,Rogalla P,Klessen C,Lembcke A,Bornemann L,Dicken V,Hamm B,Bauknecht HC

    更新日期:2010-02-01 00:00:00

  • Classification of breast masses using selected shape, edge-sharpness, and texture features with linear and kernel-based classifiers.

    abstract::Breast masses due to benign disease and malignant tumors related to breast cancer differ in terms of shape, edge-sharpness, and texture characteristics. In this study, we evaluate a set of 22 features including 5 shape factors, 3 edge-sharpness measures, and 14 texture features computed from 111 regions in mammograms,...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-007-9102-z

    authors: Mu T,Nandi AK,Rangayyan RM

    更新日期:2008-06-01 00:00:00

  • NIRViz: 3D visualization software for multimodality optical imaging using visualization toolkit (VTK) and insight segmentation toolkit (ITK).

    abstract::Optical imaging using near-infrared light is used for noninvasive probing of tissues to recover vascular and molecular status of healthy and diseased tissues using hemoglobin contrast arising due to absorption of light. While multimodality optical techniques exist, visualization techniques in this area are limited. Ad...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9362-5

    authors: Taka SJ,Srinivasan S

    更新日期:2011-12-01 00:00:00

  • CT and MR image fusion scheme in nonsubsampled contourlet transform domain.

    abstract::Fusion of CT and MR images allows simultaneous visualization of details of bony anatomy provided by CT image and details of soft tissue anatomy provided by MR image. This helps the radiologist for the precise diagnosis of disease and for more effective interventional treatment procedures. This paper aims at designing ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9664-x

    authors: Ganasala P,Kumar V

    更新日期:2014-06-01 00:00:00

  • Can the documented patient briefing be carried out with an iPad app?

    abstract::To evaluate the feasibility of an iPad-based documented patient briefing for Magnetic Resonance Imaging (MRI) examinations. A standard briefing sheet and questionnaire for a MRI scan was converted from paper form into an iPad application. Twenty patients, who had been referred for an MRI scan, were briefed about the e...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9560-9

    authors: Schlechtweg PM,Hammon M,Heberlein C,Giese D,Uder M,Schwab SA

    更新日期:2013-06-01 00:00:00

  • Effect of viewing angle on luminance and contrast for a five-million-pixel monochrome display and a nine-million-pixel color liquid crystal display.

    abstract::Digital imaging systems used in radiology rely on electronic display devices to present images to human observers. Active-matrix liquid crystal displays (AMLCDs) continue to improve and are beginning to be considered for diagnostic image display. In spite of recent progress, AMLCDs are characterized by a change in lum...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-004-1021-7

    authors: Fifadara DH,Averbukh A,Channin DS,Badano A

    更新日期:2004-12-01 00:00:00

  • Characterization of monochrome CRT display systems in the field.

    abstract::This article presents a review of image quality assessment methods for monochrome CRTs in the field as opposed to the laboratory. The review includes image quality programs at the University of Washington, the University of Texas at Houston, the University of Michigan, and the University of Arizona. CRT manufacturers ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168851

    authors: Roehrig H,Willis CE,Damento MA

    更新日期:1999-11-01 00:00:00

  • Detection of breast cancer with a computer-aided detection applied to full-field digital mammography.

    abstract::A study was conducted to evaluate the sensitivity of computer-aided detection (CAD) with full-field digital mammography in detection of breast cancer, based on mammographic appearance and histopathology. Retrospectively, CAD sensitivity was assessed in total group of 152 cases for subgroups based on breast density, ma...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9564-5

    authors: Murakami R,Kumita S,Tani H,Yoshida T,Sugizaki K,Kuwako T,Kiriyama T,Hakozaki K,Okazaki E,Yanagihara K,Iida S,Haga S,Tsuchiya S

    更新日期:2013-08-01 00:00:00

  • Financial assessment of a picture archiving and communication system implemented all at once.

    abstract::The objective of this study was to determine the differential cost between film-based radiology and a hospital-wide picture archiving and communication system (PACS) implemented all at once. The cash flow and running costs of PACS and film-based operation were measured over an 8-year time horizon. When the hospital-wi...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-0632-6

    authors: Fang YC,Yang MC,Hsueh YS

    更新日期:2006-01-01 00:00:00

  • One Night in the ED.

    abstract::Radiology 2.0: One Night in the ED is an app that presents users with scrollable CT images for common scenarios found in any Emergency Department (ED). A great tool for a junior resident before starting call, it allows the user to build confidence by experiencing a simulated environment of viewing all images of a case...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-015-9797-1

    authors: Drexler IR

    更新日期:2015-08-01 00:00:00

  • Expanding the functionality of speech recognition in radiology: creating a real-time methodology for measurement and analysis of occupational stress and fatigue.

    abstract::While occupational stress and fatigue have been well described throughout medicine, the radiology community is particularly susceptible due to declining reimbursements, heightened demands for service deliverables, and increasing exam volume and complexity. The resulting occupational stress can be variable in nature an...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9540-0

    authors: Reiner BI

    更新日期:2013-02-01 00:00:00

  • Classification of hypervascular liver lesions based on hepatic artery and portal vein blood supply coefficients calculated from triphasic CT scans.

    abstract::Perfusion CT of the liver typically involves scanning the liver at least 20 times, resulting in a large radiation dose. We developed and validated a simplified model of tumor blood supply that can be applied to standard triphasic scans and evaluated whether this can be used to distinguish benign and malignant liver le...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-014-9725-9

    authors: Boas FE,Kamaya A,Do B,Desser TS,Beaulieu CF,Vasanawala SS,Hwang GL,Sze DY

    更新日期:2015-04-01 00:00:00

  • Computer-aided detection scheme for sentinel lymph nodes in lymphoscintigrams using symmetrical property around mapped injection point.

    abstract::It is difficult to detect sentinel lymph nodes (SLNs) around an injection point of radiopharmaceuticals mapped in lymphoscintigrams. The purpose of this study was to develop a computer-aided detection (CAD) scheme for SLNs by a subtraction technique using the symmetrical property in the mapped injection point. Our dat...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9396-8

    authors: Nakayama R,Hizukuri A,Yamamoto K,Nakako N,Nagasawa N,Takeda K

    更新日期:2012-02-01 00:00:00

  • MRIdb: medical image management for biobank research.

    abstract::Clinical picture archiving and communications systems provide convenient, efficient access to digital medical images from multiple modalities but can prove challenging to deploy, configure and use. MRIdb is a self-contained image database, particularly suited to the storage and management of magnetic resonance imaging...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9604-9

    authors: Woodbridge M,Fagiolo G,O'Regan DP

    更新日期:2013-10-01 00:00:00

  • Estimates of Patient Radiation Doses in Digital Radiography Using DICOM Information at a Large Teaching Hospital in Oman.

    abstract::In this study, we sought to estimate the patient radiation doses in the digital radiography X-ray examinations conducted in a large hospital. The patient exposure factors and kerma-area product (PKA) were retrospectively recorded via the Digital Imaging and Communications in Medicine (DICOM) header for 547 patients. T...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00199-y

    authors: Suliman II

    更新日期:2020-02-01 00:00:00

  • An effective approach of lesion segmentation within the breast ultrasound image based on the cellular automata principle.

    abstract::In this paper, a novel lesion segmentation within breast ultrasound (BUS) image based on the cellular automata principle is proposed. Its energy transition function is formulated based on global image information difference and local image information difference using different energy transfer strategies. First, an en...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9450-6

    authors: Liu Y,Cheng HD,Huang J,Zhang Y,Tang X

    更新日期:2012-10-01 00:00:00

  • Computed radiography in pediatrics.

    abstract::Computed radiography (CR) has various advantages such as dynamic range. Diagnostic accuracy with CR using reduced radiation dose is considered comparable with that of conventional film-screen radiography in diagnosing apparent chest abnormalities. In addition to reducing the radiation dose, delineation of the various ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168076

    authors: Aoki K

    更新日期:1995-02-01 00:00:00

  • Automated pediatric abdominal effective diameter measurements versus age-predicted body size for normalization of CT dose.

    abstract::There has been increasing interest in adjusting CT radiation dose data for patient body size. A method for automated computation of the abdominal effective diameter of a patient from a CT image has previously only been tested in adult patients. In this work, we tested the method on a set of 128 pediatric patients aged...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9623-6

    authors: Cheng PM,Vachon LA,Duddalwar VA

    更新日期:2013-12-01 00:00:00

  • PDA-phone-based instant transmission of radiological images over a CDMA network by combining the PACS screen with a Bluetooth-interfaced local wireless link.

    abstract::Remote teleconsultation by specialists is important for timely, correct, and specialized emergency surgical and medical decision making. In this paper, we designed a new personal digital assistant (PDA)-phone-based emergency teleradiology system by combining cellular communication with Bluetooth-interfaced local wirel...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-007-9002-2

    authors: Kim DK,Yoo SK,Park JJ,Kim SH

    更新日期:2007-06-01 00:00:00

  • Integrating an Ontology of Radiology Differential Diagnosis with ICD-10-CM, RadLex, and SNOMED CT.

    abstract::An ontology offers a human-readable and machine-computable representation of the concepts in a domain and the relationships among them. Mappings between ontologies enable the reuse and interoperability of biomedical knowledge. We sought to map concepts of the Radiology Gamuts Ontology (RGO), an ontology that links dis...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00186-3

    authors: Filice RW,Kahn CE Jr

    更新日期:2019-04-01 00:00:00

  • Scoliosis evaluation by direct digital radiography and computerized post-processing.

    abstract::With the introduction of direct digital radiography into clinical practice, there are opportunities to provide faster and more reliable ways of performing traditional radiological tasks. A technique was developed for evaluating and measuring scoliosis, which involves the computerized stitching of a radiograph of the t...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-002-5033-x

    authors: Berliner L,Kreang-Arekul S,Kaufman L

    更新日期:2002-01-01 00:00:00

  • The impact of networking on image acquisition system design.

    abstract::Widespread integration of networking technology will change the hospital imaging environment, making computational, archiving, and film production services available to network-connected modalities. This change will be reflected in the designs of the image acquisition modalities themselves. A view of the future is pre...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168154

    authors: Perry JH

    更新日期:1991-11-01 00:00:00

  • Endowing a Content-Based Medical Image Retrieval System with Perceptual Similarity Using Ensemble Strategy.

    abstract::Content-based medical image retrieval (CBMIR) is a powerful resource to improve differential computer-aided diagnosis. The major problem with CBMIR applications is the semantic gap, a situation in which the system does not follow the users' sense of similarity. This gap can be bridged by the adequate modeling of simil...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-015-9809-1

    authors: Bedo MV,Pereira Dos Santos D,Ponciano-Silva M,de Azevedo-Marques PM,Ferreira de Carvalho AP,Traina C Jr

    更新日期:2016-02-01 00:00:00

  • Deep Convolutional Neural Networks for Endotracheal Tube Position and X-ray Image Classification: Challenges and Opportunities.

    abstract::The goal of this study is to evaluate the efficacy of deep convolutional neural networks (DCNNs) in differentiating subtle, intermediate, and more obvious image differences in radiography. Three different datasets were created, which included presence/absence of the endotracheal (ET) tube (n = 300), low/normal positio...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-017-9980-7

    authors: Lakhani P

    更新日期:2017-08-01 00:00:00

  • 3D Brain Imaging in Vascular Segmentation of Cerebral Venous Sinuses.

    abstract::The three-dimensional (3D) visualization of dural venous sinuses (DVS) networks is desired by surgical trainers to create a clear mental picture of the neuroanatomical orientation of the complex cerebral anatomy. Our purpose is to document those identified during routine 3D venography created through 3D models using t...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0125-4

    authors: Karakas AB,Govsa F,Ozer MA,Eraslan C

    更新日期:2019-04-01 00:00:00

  • Artifacts found during quality assurance testing of computed radiography and digital radiography detectors.

    abstract::A series of artifact images, obtained over 5 years of performance testing, of both computed radiography (CR) and integrated digital radiographic X-ray imaging detectors are presented. The images presented are all either flat field or test object images and show artifacts previously either undescribed in the existing l...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-008-9109-0

    authors: Honey ID,Mackenzie A

    更新日期:2009-08-01 00:00:00

  • Panoramic dental radiography using a charge-coupled device receptor.

    abstract::Panoramic radiography using a slit beam and film/screen receptor is standard for the emergency room evaluation of mandibular fractures and also in dentistry. This study compared the spatial resolution, area distortion factors, and the dosage considerations for a panoramic system where standard film/screen and a charge...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168293

    authors: Farman AG,Farman TT

    更新日期:1998-08-01 00:00:00