Abstract:
:Efficient data compression is essential for practical daily operation of computed radiography (CR) systems. In this study the clinical applicability of type III irreversible high data compression using an FCR 9501 chest unit (Fuji Photo Film, Tokyo, Japan) was evaluated. Sixty-eight normal and 93 various abnormal cases, with an additional 15 cases of lung cancers with solitary lung nodules, were selected from the file. A pair of hard copies of original images and images reconstructed using type III compression was made for each case. Six radiologists evaluated the image quality by visual rating and receiver operating characteristic (ROC) curve analysis. For all five anatomic regions of normal cases, "original equal to compressed" was the most common response, followed by "original significantly better than compressed." When abnormal cases were evaluated for diagnostic information, there was no significant difference between the compressed and original images. ROC curve analysis on lung nodules with lung cancer showed no significant difference between the two. Compressed CR images using the type III irreversible technique are clinically applicable and acceptable despite slight degradation of image quality.
journal_name
J Digit Imagingjournal_title
Journal of digital imagingauthors
Egashira K,Nakata H,Watanabe H,Uchida K,Nakamura K,Ishino Y,Horino K,Yoshikawa Rdoi
10.1007/BF03178080subject
Has Abstractpub_date
1998-11-01 00:00:00pages
176-81issue
4eissn
0897-1889issn
1618-727Xjournal_volume
11pub_type
杂志文章abstract::The authors present an adaptation of the macro recording feature on the Siemens Magic View 1000 workstation, which, with the click of one button, launches a macro that performs 3 clinically useful image manipulations. Using a Magic View 1004 Siemens unix workstation, the following Macro sequence was programmed: (1) se...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-002-5078-x
更新日期:2002-01-01 00:00:00
abstract::To compare hard copies and soft copies processed with linear and nonlinear conversion of skeletal fractures, we performed a receiver-operating characteristics study of 25 digital radiographs. There was no statistical difference between hard copies with linear and nonlinear conversion. However, it may be difficult to d...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168067
更新日期:1995-02-01 00:00:00
abstract::The strategic development and deployment of a health management information technology infrastructure is discussed from two perspectives for radiologists and for other medical technologists: the integrated delivery system (IDS) perspective and a total quality-management (TQM) perspective. On the one hand, an IDS persp...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168176
更新日期:1998-11-01 00:00:00
abstract::Even though facilities using computed radiography (CR) operate in an electronic environment, the production of hard-copy films is still necessary during the transition period, as well as for particular needs following complete implementation. We have implemented a quantitative technique to match the response of printe...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03167622
更新日期:2000-05-01 00:00:00
abstract:INTRODUCTION:To validate a preliminary version of a radiological lexicon (RadLex) against terms found in thoracic CT reports and to index report content in RadLex term categories. MATERIAL AND METHODS:Terms from a random sample of 200 thoracic CT reports were extracted using a text processor and matched against RadLex...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-007-9051-6
更新日期:2008-12-01 00:00:00
abstract::The Fuhrman nuclear grade is a recognized prognostic factor for patients with clear cell renal cell carcinoma (CCRCC) and its pre-treatment evaluation significantly affects decision-making in terms of management. In this study, we aimed to assess the feasibility of a combined approach of radiomics and machine learning...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-020-00336-y
更新日期:2020-08-01 00:00:00
abstract::The objective of this study was to determine the differential cost between film-based radiology and a hospital-wide picture archiving and communication system (PACS) implemented all at once. The cash flow and running costs of PACS and film-based operation were measured over an 8-year time horizon. When the hospital-wi...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-006-0632-6
更新日期:2006-01-01 00:00:00
abstract::While the implementation of Picture Archiving and Communication Systems (PACS) has revolutionized the field of radiology, there has been considerably less utilization of PACS by emergency physicians with point-of-care ultrasound. Benefits of PACS archival of images include improved quality assurance, preservation of i...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-016-9893-x
更新日期:2016-12-01 00:00:00
abstract::In today's radiology workflow, free-text reporting is established as the most common medium to capture, store, and communicate clinical information. Radiologists routinely refer to prior radiology reports of a patient to recall critical information for new diagnosis, which is quite tedious, time consuming, and prone t...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-018-0116-5
更新日期:2019-02-01 00:00:00
abstract::For a region-wide teleradiology network in Germany a vendor-independent Uptime-server concept was defined. The Uptime-server was realized for the availability check and prospective error-detection of the emergency teleradiology servers and clients based on encrypted digital imaging and communication in medicine (DICOM...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-006-1044-3
更新日期:2007-12-01 00:00:00
abstract::Medical image segmentation is the crucial process for three-dimensional (3D) modeling. Many studies have claimed to suggest more accurate ways of segmentation. However, such research seems to have the drawback that it works against the parsimony principle. These methods have to resegment the regions of interest (ROIs)...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03190342
更新日期:2001-06-01 00:00:00
abstract::To evaluate the feasibility of an iPad-based documented patient briefing for Magnetic Resonance Imaging (MRI) examinations. A standard briefing sheet and questionnaire for a MRI scan was converted from paper form into an iPad application. Twenty patients, who had been referred for an MRI scan, were briefed about the e...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-012-9560-9
更新日期:2013-06-01 00:00:00
abstract::An enterprise imaging (EI) strategy is an organized plan to optimize the electronic health record (EHR) so that healthcare providers have intuitive and immediate access to all patient clinical images and their associated documentation, regardless of source. We describe ten steps recommended to achieve the goal of impl...
journal_title:Journal of digital imaging
pub_type: 杂志文章,评审
doi:10.1007/s10278-019-00236-w
更新日期:2019-08-01 00:00:00
abstract::Radiology 2.0: One Night in the ED is an app that presents users with scrollable CT images for common scenarios found in any Emergency Department (ED). A great tool for a junior resident before starting call, it allows the user to build confidence by experiencing a simulated environment of viewing all images of a case...
journal_title:Journal of digital imaging
pub_type: 杂志文章,评审
doi:10.1007/s10278-015-9797-1
更新日期:2015-08-01 00:00:00
abstract::A prior ultrasound study indicated that images with low to moderate levels of JPEG and wavelet compression were acceptable for diagnostic purposes. The purpose of this study is to validate this prior finding using the Joint Photographic Experts Group (JPEG) baseline compression algorithm, at a compression ratio of app...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-002-0003-x
更新日期:2002-03-01 00:00:00
abstract::We introduce a set of worksheets to facilitate standardized comparisons among scheduling systems, hospital information systems, radiology information systems, and picture archiving and communication systems vendors. For each system category, we provide worksheets to evaluate the features, performance, installation req...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168605
更新日期:1996-08-01 00:00:00
abstract::Recent technological innovations have created new opportunities for the increased adoption of virtual reality (VR) and augmented reality (AR) applications in medicine. While medical applications of VR have historically seen greater adoption from patient-as-user applications, the new era of VR/AR technology has created...
journal_title:Journal of digital imaging
pub_type: 杂志文章,评审
doi:10.1007/s10278-018-0122-7
更新日期:2019-02-01 00:00:00
abstract::Scheduling of CT and MR exams requires reasonable estimates for expected scan duration. However, scan-time variability and efficiency gains from combining multiple exams are not quantitatively well characterized. In this work, we developed an informatics approach to quantify typical duration, duration variability, and...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-019-00252-w
更新日期:2020-02-01 00:00:00
abstract::The efficacy of two medical-grade, self-calibrating, gray scale displays were compared with regard to impact on sensitivity and specificity for the detection of interstitial lung disease (ILD) on computed radiographs (CR). The displays were a 5-megapixel (MP) cathode ray tube (CRT) device and a 3-MP liquid crystal dis...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-004-1013-7
更新日期:2004-09-01 00:00:00
abstract::Liquid crystal displays (LCD) are rapidly replacing cathode ray tube displays (CRT) for medical imaging. LCD technology has improved significantly in the last few years and has important advantages over CRT. However, there are still some aspects of LCD that raise questions as to the usefulness of liquid crystal displa...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-005-2939-0
更新日期:2005-09-01 00:00:00
abstract::We evaluated the usefulness of a computerized analysis system in the detection of interstitial lung abnormalities in digitized chest radiography. This system uses the processes of four-directional Laplacian-Gaussian filtering, linear opacity judgment, and linear opacity subtraction. For qualitative analysis, we employ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168557
更新日期:1997-05-01 00:00:00
abstract::Perfusion CT of the liver typically involves scanning the liver at least 20 times, resulting in a large radiation dose. We developed and validated a simplified model of tumor blood supply that can be applied to standard triphasic scans and evaluated whether this can be used to distinguish benign and malignant liver le...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-014-9725-9
更新日期:2015-04-01 00:00:00
abstract::In the UK, physicists and radiographers perform routine quality control (QC) of digital mammography equipment at daily, weekly and monthly intervals. The tests performed and tolerances are specified by standard protocols. The manual nature of many of the tests introduces variability due to the positioning of regions o...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-014-9759-z
更新日期:2015-10-01 00:00:00
abstract::A study was conducted to evaluate the sensitivity of computer-aided detection (CAD) with full-field digital mammography in detection of breast cancer, based on mammographic appearance and histopathology. Retrospectively, CAD sensitivity was assessed in total group of 152 cases for subgroups based on breast density, ma...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-012-9564-5
更新日期:2013-08-01 00:00:00
abstract::Excessive cephalocaudal anatomic (Z-axis) coverage can lead to unnecessary radiation exposure to a patient. In this study, an automated computing model was developed for identifying instances of potentially excessive Z-axis coverage with abdomen-pelvis examinations. Eight patient and imaging attributes including patie...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-014-9743-7
更新日期:2015-06-01 00:00:00
abstract::Computed tomography (CT) scans usually include some disadvantages due to the nature of the imaging procedure, and these handicaps prevent accurate abdomen segmentation. Discontinuous abdomen edges, bed section of CT, patient information, closeness between the edges of the abdomen and CT, poor contrast, and a narrow hi...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-017-0032-0
更新日期:2018-04-01 00:00:00
abstract::There is increasing prevalence of digital diagnostic imaging in veterinary medicine with a progressive need to use medical imaging software. As Digital Imaging and Communications in Medicine (DICOM)-viewers for veterinary use do not require medical device approval in many countries, freeware viewers might be a practic...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-019-00194-3
更新日期:2020-02-01 00:00:00
abstract::The objective of this study was to determine the clinical value of computed tomography (CT) image-based texture analysis in predicting microvascular invasion of primary hepatocellular carcinoma (HCC). CT images of patients with HCC from May 2017 to May 2019 confirmed by surgery and histopathology were retrospectively ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-020-00386-2
更新日期:2020-12-01 00:00:00
abstract::This study tracked a radiology department's conversion from utilization of a Kodak Amber analog system to a Kodak DirectView DR 5100 digital system. Through the use of ProModel Optimization Suite, a workflow simulation software package, significant quantitative information was derived from workflow process data measur...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-006-0770-x
更新日期:2006-01-01 00:00:00
abstract::The goal of this study is to provide the clinical end users of an enterprisewide picture archiving and communication system/Web application with a thorough understanding of the application and education to maintain patient privacy and protection. ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-002-5101-2
更新日期:2002-01-01 00:00:00