An Efficient Pipeline for Abdomen Segmentation in CT Images.

Abstract:

:Computed tomography (CT) scans usually include some disadvantages due to the nature of the imaging procedure, and these handicaps prevent accurate abdomen segmentation. Discontinuous abdomen edges, bed section of CT, patient information, closeness between the edges of the abdomen and CT, poor contrast, and a narrow histogram can be regarded as the most important handicaps that occur in abdominal CT scans. Currently, one or more handicaps can arise and prevent technicians obtaining abdomen images through simple segmentation techniques. In other words, CT scans can include the bed section of CT, a patient's diagnostic information, low-quality abdomen edges, low-level contrast, and narrow histogram, all in one scan. These phenomena constitute a challenge, and an efficient pipeline that is unaffected by handicaps is required. In addition, analysis such as segmentation, feature selection, and classification has meaning for a real-time diagnosis system in cases where the abdomen section is directly used with a specific size. A statistical pipeline is designed in this study that is unaffected by the handicaps mentioned above. Intensity-based approaches, morphological processes, and histogram-based procedures are utilized to design an efficient structure. Performance evaluation is realized in experiments on 58 CT images (16 training, 16 test, and 26 validation) that include the abdomen and one or more disadvantage(s). The first part of the data (16 training images) is used to detect the pipeline's optimum parameters, while the second and third parts are utilized to evaluate and to confirm the segmentation performance. The segmentation results are presented as the means of six performance metrics. Thus, the proposed method achieves remarkable average rates for training/test/validation of 98.95/99.36/99.57% (jaccard), 99.47/99.67/99.79% (dice), 100/99.91/99.91% (sensitivity), 98.47/99.23/99.85% (specificity), 99.38/99.63/99.87% (classification accuracy), and 98.98/99.45/99.66% (precision). In summary, a statistical pipeline performing the task of abdomen segmentation is achieved that is not affected by the disadvantages, and the most detailed abdomen segmentation study is performed for the use before organ and tumor segmentation, feature extraction, and classification.

journal_name

J Digit Imaging

authors

Koyuncu H,Ceylan R,Sivri M,Erdogan H

doi

10.1007/s10278-017-0032-0

subject

Has Abstract

pub_date

2018-04-01 00:00:00

pages

262-274

issue

2

eissn

0897-1889

issn

1618-727X

pii

10.1007/s10278-017-0032-0

journal_volume

31

pub_type

杂志文章
  • A study for watermark methods appropriate to medical images.

    abstract::The network system, including the picture archiving and communication system (PACS), is essential in hospital and medical imaging fields these days. Many medical images are accessed and processed on the web, as well as in PACS. Therefore, any possible accidents caused by the illegal modification of medical images must...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03190332

    authors: Cho Y,Ahn B,Kim JS,Kim IY,Kim SI

    更新日期:2001-06-01 00:00:00

  • Detection of breast cancer with a computer-aided detection applied to full-field digital mammography.

    abstract::A study was conducted to evaluate the sensitivity of computer-aided detection (CAD) with full-field digital mammography in detection of breast cancer, based on mammographic appearance and histopathology. Retrospectively, CAD sensitivity was assessed in total group of 152 cases for subgroups based on breast density, ma...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9564-5

    authors: Murakami R,Kumita S,Tani H,Yoshida T,Sugizaki K,Kuwako T,Kiriyama T,Hakozaki K,Okazaki E,Yanagihara K,Iida S,Haga S,Tsuchiya S

    更新日期:2013-08-01 00:00:00

  • Detection of microcalcifications by means of multiscale methods and statistical techniques.

    abstract::The detection of clustered microcalcifications can help the radiologist to detect early breast cancer. Microcalcifications exhibit some important characteristics, such as small size and high luminosity. Use of a computer-aided diagnosis (CAD) method can prevent them being overlooked. In this report, a multiresolution ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167672

    authors: Mata Campos R,Vidal EM,Nava E,Martínez-Morillo M,Sendra F

    更新日期:2000-05-01 00:00:00

  • Interactive image enhancement of CR and DR images.

    abstract::There is continual pressure on the radiology department to increase its productivity. Two important links to productivity in the computed/digital radiography (CR/DR) workflow chain are the postprocessing step by technologists and the primary diagnosis step by radiologists, who may apply additional image enhancements t...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-004-1000-z

    authors: Thomas MA,Rowberg AH,Langer SG,Kim Y

    更新日期:2004-09-01 00:00:00

  • A mobile tele-radiology imaging system with JPEG2000 for an emergency care.

    abstract::The aim of this study was to design a tele-radiology imaging system for rapid emergency care via mobile networks and to assess the diagnostic feasibility of the Joint Photographic Experts Group 2000 (JPEG2000) radiological imaging using portable devices. Rapid patient information and image exchange is helpful to make ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-010-9335-0

    authors: Kim DK,Kim EY,Yang KH,Lee CK,Yoo SK

    更新日期:2011-08-01 00:00:00

  • An effective approach of lesion segmentation within the breast ultrasound image based on the cellular automata principle.

    abstract::In this paper, a novel lesion segmentation within breast ultrasound (BUS) image based on the cellular automata principle is proposed. Its energy transition function is formulated based on global image information difference and local image information difference using different energy transfer strategies. First, an en...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9450-6

    authors: Liu Y,Cheng HD,Huang J,Zhang Y,Tang X

    更新日期:2012-10-01 00:00:00

  • Automated detection of z-axis coverage with abdomen-pelvis computed tomography examinations.

    abstract::Excessive cephalocaudal anatomic (Z-axis) coverage can lead to unnecessary radiation exposure to a patient. In this study, an automated computing model was developed for identifying instances of potentially excessive Z-axis coverage with abdomen-pelvis examinations. Eight patient and imaging attributes including patie...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-014-9743-7

    authors: Zhang M,Wellnitz C,Cui C,Pavlicek W,Wu T

    更新日期:2015-06-01 00:00:00

  • Physician experience with viewing digital radiographs in an intensive care unit environment.

    abstract::After several years of continuous operation, the utility of digital viewing stations as assessed by bedside clinicians has been investigated through the distribution of questionnaires to past and present users. The results of the questionnaire have indicated that the bedside physicians prefer using the workstations ov...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168415

    authors: Humphrey LM,Fitzpatrick K,Paine SS,Ravin CE

    更新日期:1993-02-01 00:00:00

  • Comparative performance analysis of state-of-the-art classification algorithms applied to lung tissue categorization.

    abstract::In this paper, we compare five common classifier families in their ability to categorize six lung tissue patterns in high-resolution computed tomography (HRCT) images of patients affected with interstitial lung diseases (ILD) and with healthy tissue. The evaluated classifiers are naive Bayes, k-nearest neighbor, J48 d...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-008-9158-4

    authors: Depeursinge A,Iavindrasana J,Hidki A,Cohen G,Geissbuhler A,Platon A,Poletti PA,Müller H

    更新日期:2010-02-01 00:00:00

  • Evaluation of irreversible JPEG compression for a clinical ultrasound practice.

    abstract::A prior ultrasound study indicated that images with low to moderate levels of JPEG and wavelet compression were acceptable for diagnostic purposes. The purpose of this study is to validate this prior finding using the Joint Photographic Experts Group (JPEG) baseline compression algorithm, at a compression ratio of app...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-002-0003-x

    authors: Persons KR,Hangiandreou NJ,Charboneau NT,Charboneau J,James E,Douglas BR,Salmon AP,Knudsen JM,Erickson BJ

    更新日期:2002-03-01 00:00:00

  • Feature-Motivated Simplified Adaptive PCNN-Based Medical Image Fusion Algorithm in NSST Domain.

    abstract::Multimodality medical image fusion plays a vital role in diagnosis, treatment planning, and follow-up studies of various diseases. It provides a composite image containing critical information of source images required for better localization and definition of different organs and lesions. In the state-of-the-art imag...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-015-9806-4

    authors: Ganasala P,Kumar V

    更新日期:2016-02-01 00:00:00

  • NIRViz: 3D visualization software for multimodality optical imaging using visualization toolkit (VTK) and insight segmentation toolkit (ITK).

    abstract::Optical imaging using near-infrared light is used for noninvasive probing of tissues to recover vascular and molecular status of healthy and diseased tissues using hemoglobin contrast arising due to absorption of light. While multimodality optical techniques exist, visualization techniques in this area are limited. Ad...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9362-5

    authors: Taka SJ,Srinivasan S

    更新日期:2011-12-01 00:00:00

  • A heuristic approach to automated nipple detection in digital mammograms.

    abstract::In this paper, a heuristic approach to automated nipple detection in digital mammograms is presented. A multithresholding algorithm is first applied to segment the mammogram and separate the breast region from the background region. Next, the problem is considered separately for craniocaudal (CC) and mediolateral-obli...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9575-x

    authors: Jas M,Mukhopadhyay S,Chakraborty J,Sadhu A,Khandelwal N

    更新日期:2013-10-01 00:00:00

  • Environmental designs for reading from imaging work stations: ergonomic and architectural features.

    abstract::Despite the rapid progress made in the electronic design of imaging work stations for medicine, much less effort has gone into the design of environments in which such systems will be used. Based on studies of radiologist film reading sessions, considerable time will be spent working at such viewing systems. If the ro...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168035

    authors: Horii SC,Horii HN,Mun SK,Benson HR,Zeman RK

    更新日期:1989-08-01 00:00:00

  • Hybrid Airway Segmentation Using Multi-Scale Tubular Structure Filters and Texture Analysis on 3D Chest CT Scans.

    abstract::Airway diseases are frequently related to morphological changes that may influence lung physiology. Accurate airway region segmentation may be useful for quantitative evaluation of disease prognosis and therapy efficacy. The information can also be applied to understand the fundamental mechanisms of various lung disea...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0158-8

    authors: Lee M,Lee JG,Kim N,Seo JB,Lee SM

    更新日期:2019-10-01 00:00:00

  • Management of the picture archiving and communications system archive at Texas Children's Hospital.

    abstract::As hospitals convert from conventional film-based imaging to picture archival and communications systems (PACS), methods for managing an enormous library of images must change considerably. While most hospitals are required to retain general, nonmammographic, radiologic images for 7 years beyond the examination date, ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03190304

    authors: Blado ME

    更新日期:2001-06-01 00:00:00

  • Stereoscopic interpretation of low-dose breast tomosynthesis projection images.

    abstract::The purpose of this study was to evaluate stereoscopic perception of low-dose breast tomosynthesis projection images. In this Institutional Review Board exempt study, craniocaudal breast tomosynthesis cases (N = 47), consisting of 23 biopsy-proven malignant mass cases and 24 normal cases, were retrospectively reviewed...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9648-x

    authors: Muralidhar GS,Markey MK,Bovik AC,Haygood TM,Stephens TW,Geiser WR,Garg N,Adrada BE,Dogan BE,Carkaci S,Khisty R,Whitman GJ

    更新日期:2014-04-01 00:00:00

  • Estimates of Patient Radiation Doses in Digital Radiography Using DICOM Information at a Large Teaching Hospital in Oman.

    abstract::In this study, we sought to estimate the patient radiation doses in the digital radiography X-ray examinations conducted in a large hospital. The patient exposure factors and kerma-area product (PKA) were retrospectively recorded via the Digital Imaging and Communications in Medicine (DICOM) header for 547 patients. T...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00199-y

    authors: Suliman II

    更新日期:2020-02-01 00:00:00

  • Of Mice and Roentgen: Radiologist Satisfaction with a Non-conventional 13-Button Mouse-One Institution's Experience.

    abstract::Increasing radiologic exam volume and complexity necessitates leveraging advanced hardware solutions to optimize workflow efficiency. We evaluated radiologist satisfaction of a programmable 13-button non-conventional mouse compared to a conventional three-button mouse in daily interpretation workflow following a brief...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0094-7

    authors: Denton K,Haider I,Hill J,Hunt SL,Ash R

    更新日期:2018-12-01 00:00:00

  • A breast density index for digital mammograms based on radiologists' ranking.

    abstract::The purpose of this study was to develop and evaluate a computerized method of calculating a breast density index (BDI) from digitized mammograms that was designed specifically to model radiologists' perception of breast density. A set of 153 pairs of digitized mammograms (cranio-caudal, CC, and mediolateral oblique, ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168733

    authors: Boone JM,Lindfors KK,Beatty CS,Seibert JA

    更新日期:1998-08-01 00:00:00

  • Cell Nuclei Segmentation in Cytological Images Using Convolutional Neural Network and Seeded Watershed Algorithm.

    abstract::Morphometric analysis of nuclei is crucial in cytological examinations. Unfortunately, nuclei segmentation presents many challenges because they usually create complex clusters in cytological samples. To deal with this problem, we are proposing an approach, which combines convolutional neural network and watershed tra...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00200-8

    authors: Kowal M,Żejmo M,Skobel M,Korbicz J,Monczak R

    更新日期:2020-02-01 00:00:00

  • Impact of digital radiography on clinical workflow and patient satisfaction.

    abstract::Compared to traditional film radiography, digital radiography is believed to improve workflow and patient throughput. Digital radiography permits the technologist to immediately view the quality of the film directly at the modality. Additional workflow improvements, therefore, should be achieved with the integration o...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167662

    authors: Dackiewicz D,Bergsneider C,Piraino D

    更新日期:2000-05-01 00:00:00

  • Contrast information of digital imaging in laser film digitizer and display monitor.

    abstract::A 10-bit or 12-bit gray scale is provided in commercial laser film digitizers. The true contrast resolution on the digitized image within a laser spot area of 200 microns in diameter is limited by both the quantum mottle and instrumentation noise. In this report, we investigated the mean value, standard deviation, and...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03170571

    authors: Lo SC,Gaskill JW,Mun SK,Krasner BH

    更新日期:1990-05-01 00:00:00

  • Comparison of algorithms to enhance spicules of spiculated masses on mammography.

    abstract::We have developed an algorithm for enhancement of spicules of spiculated masses, which uses the discrete radon transform. Previously, we employed a commonly used method to compute the discrete radon transform, which we refer to as the DRT. Recently, a new, more exact method to compute the discrete radon transform was ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-007-9015-x

    authors: Sampat MP,Whitman GJ,Bovik AC,Markey MK

    更新日期:2008-03-01 00:00:00

  • Medicolegal considerations in the implementation of a PACS web application.

    abstract::The goal of this study is to provide the clinical end users of an enterprisewide picture archiving and communication system/Web application with a thorough understanding of the application and education to maintain patient privacy and protection. ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-002-5101-2

    authors: Cook K

    更新日期:2002-01-01 00:00:00

  • One Night in the ED.

    abstract::Radiology 2.0: One Night in the ED is an app that presents users with scrollable CT images for common scenarios found in any Emergency Department (ED). A great tool for a junior resident before starting call, it allows the user to build confidence by experiencing a simulated environment of viewing all images of a case...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-015-9797-1

    authors: Drexler IR

    更新日期:2015-08-01 00:00:00

  • Effect of viewing angle on luminance and contrast for a five-million-pixel monochrome display and a nine-million-pixel color liquid crystal display.

    abstract::Digital imaging systems used in radiology rely on electronic display devices to present images to human observers. Active-matrix liquid crystal displays (AMLCDs) continue to improve and are beginning to be considered for diagnostic image display. In spite of recent progress, AMLCDs are characterized by a change in lum...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-004-1021-7

    authors: Fifadara DH,Averbukh A,Channin DS,Badano A

    更新日期:2004-12-01 00:00:00

  • Early lung cancer detection using the self-evaluation scoring questionnaire and chest digital radiography: a 3-year follow-up study in China.

    abstract::The standard definition of high-risk individuals for lung cancer was not uniform and the value of chest digital radiography (DR) in lung cancer screening was still unproven. The aim of this study was to assess whether the original questionnaire named as "Self-evaluation Scoring Questionnaire for High-risk Individuals ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9468-4

    authors: Chen B,Wang Y,Cao H,Liu D,Zhang S,Gao J,Yu J,Huang Y,Li W

    更新日期:2013-02-01 00:00:00

  • Design of a high-speed, high-resolution teleradiology network.

    abstract::A teleradiology system acquires radiographic images from one location and transmits them to one or more distant sites where they are displayed and/or converted to hard-copy film recordings. The long-term goal of teleradiology research is to show that teleradiology systems can provide diagnostically equivalent results ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167763

    authors: Stewart BK,Dwyer SJ 3rd,Kangarloo H

    更新日期:1992-08-01 00:00:00

  • Defining the role of a PACS technologist.

    abstract::As hospitals convert from conventional image processing to picture archiving and communication systems (PACS) technology, new job opportunities arose for PACS analysts, PACS system administrators, PACS operators, and PACS trainers. To support a PACS, these positions require education in computer information systems an...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-002-5095-9

    authors: Cabrera A

    更新日期:2002-01-01 00:00:00