Computed radiography printing problems: a quantitative, observer-independent solution.

Abstract:

:Even though facilities using computed radiography (CR) operate in an electronic environment, the production of hard-copy films is still necessary during the transition period, as well as for particular needs following complete implementation. We have implemented a quantitative technique to match the response of printed CR film with that of previous screen/film combinations. A stepwedge is radiographed using the conventional system. The same stepwedge is then radiographed (same geometry and technique) using the CR system. Following processing and printing, the plot of optical density versus step for the CR system is compared with that of the screen/film system. Adjustments are made to the printing parameters until the response curves are identical. All other translation tables in the system are set to be linear. This has proven to be a valuable technique for us and provides CR printed image quality that is equivalent to that of our previous screen/film combinations.

journal_name

J Digit Imaging

authors

Hildestad CA,Morin RL

doi

10.1007/BF03167622

subject

Has Abstract

pub_date

2000-05-01 00:00:00

pages

43-4

issue

2 Suppl 1

eissn

0897-1889

issn

1618-727X

journal_volume

13

pub_type

杂志文章
  • A content-boosted collaborative filtering algorithm for personalized training in interpretation of radiological imaging.

    abstract::Devising a method that can select cases based on the performance levels of trainees and the characteristics of cases is essential for developing a personalized training program in radiology education. In this paper, we propose a novel hybrid prediction algorithm called content-boosted collaborative filtering (CBCF) to...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-014-9678-z

    authors: Lin H,Yang X,Wang W

    更新日期:2014-08-01 00:00:00

  • Computed radiography in pediatrics.

    abstract::Computed radiography (CR) has various advantages such as dynamic range. Diagnostic accuracy with CR using reduced radiation dose is considered comparable with that of conventional film-screen radiography in diagnosing apparent chest abnormalities. In addition to reducing the radiation dose, delineation of the various ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168076

    authors: Aoki K

    更新日期:1995-02-01 00:00:00

  • Computed radiography: user-programmable features and capabilities.

    abstract::Digital or computed radiography (CR) using photostimulable storage phosphor plate technology is becoming increasingly popular in certain clinical applications, such as bedside radiography, where it possesses clear advantages over conventional screen-film imaging. The majority of CR systems in clinical use have been ma...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168504

    authors: Gingold EL,Tucker DM,Barnes GT

    更新日期:1994-08-01 00:00:00

  • A comparison of hard and soft copies processed with linear conversion and nonlinear conversion of skeletal fractures--a preliminary study.

    abstract::To compare hard copies and soft copies processed with linear and nonlinear conversion of skeletal fractures, we performed a receiver-operating characteristics study of 25 digital radiographs. There was no statistical difference between hard copies with linear and nonlinear conversion. However, it may be difficult to d...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168067

    authors: Kaji T,Katayama M,Kosuda S,Kusano S

    更新日期:1995-02-01 00:00:00

  • Detection of breast cancer with a computer-aided detection applied to full-field digital mammography.

    abstract::A study was conducted to evaluate the sensitivity of computer-aided detection (CAD) with full-field digital mammography in detection of breast cancer, based on mammographic appearance and histopathology. Retrospectively, CAD sensitivity was assessed in total group of 152 cases for subgroups based on breast density, ma...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9564-5

    authors: Murakami R,Kumita S,Tani H,Yoshida T,Sugizaki K,Kuwako T,Kiriyama T,Hakozaki K,Okazaki E,Yanagihara K,Iida S,Haga S,Tsuchiya S

    更新日期:2013-08-01 00:00:00

  • Displaying radiologic images on personal computers: practical applications and uses.

    abstract::This is the fifth and final article in our series for radiologists and imaging scientists on displaying, manipulating, and analyzing radiologic images on personal computers (PCs). There are many methods of transferring radiologic images into a PC, including transfer over a network, transfer from an imaging modality st...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168502

    authors: Gillespy T 3rd,Richardson ML,Rowberg AH

    更新日期:1994-08-01 00:00:00

  • Combining fast response and low cost in an intensive care unit viewing station.

    abstract::This paper describes a prototype viewing station for the Intensive Care Unit (ICU) that combines a low cost with a fast response for the primary viewing tasks. A single monitor is used together with the possibility to switch to another image on the same screen instantaneously. To reduce the time for image retrieval an...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168429

    authors: Bellon E,Houtput W,Bijnens B,Suetens P,Marchal G,Lauwers P

    更新日期:1994-05-01 00:00:00

  • An assessment of the iPad 2 as a CT teleradiology tool using brain CT with subtle intracranial hemorrhage under conventional illumination.

    abstract::We examined the potential of the iPad 2 as a teleradiologic tool for evaluating brain computed tomography (CT) with subtle hemorrhage in the conventional lighting conditions which are common situations in the remote CT reading. The comparison of the clinician's performance was undertaken through detecting hemorrhage b...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9580-0

    authors: Park JB,Choi HJ,Lee JH,Kang BS

    更新日期:2013-08-01 00:00:00

  • A Narrative Review on Clinical Applications of fNIRS.

    abstract::Functional near-infrared spectroscopy (fNIRS) is a relatively new imaging modality in the functional neuroimaging research arena. The fNIRS modality non-invasively investigates the change of blood oxygenation level in the human brain utilizing the transillumination technique. In the last two decades, the interest in t...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-020-00387-1

    authors: Rahman MA,Siddik AB,Ghosh TK,Khanam F,Ahmad M

    更新日期:2020-10-01 00:00:00

  • Improving Visibility of Stereo-Radiographic Spine Reconstruction with Geometric Inferences.

    abstract::Complex deformities of the spine, like scoliosis, are evaluated more precisely using stereo-radiographic 3D reconstruction techniques. Primarily, it uses six stereo-corresponding points available on the vertebral body for the 3D reconstruction of each vertebra. The wireframe structure obtained in this process has poor...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-015-9841-1

    authors: Kumar S,Nayak KP,Hareesha KS

    更新日期:2016-04-01 00:00:00

  • Network latency and operator performance in teleradiology applications.

    abstract::Teleradiology applications often use an interactive conferencing mode with remote control mouse pointers. When a telephone is used for voice communication, latencies of the data network can create a temporal discrepancy between the position of the mouse pointer and the verbal communication. To assess the effects of th...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168384

    authors: Stahl JN,Tellis W,Huang HK

    更新日期:2000-08-01 00:00:00

  • Strategic thinking for radiology.

    abstract::We have now analyzed the use and benefits of four Strategic Thinking Tools for Radiology: the Vision Statement, the High Five, the Two-by-Two, and Real-Win-Worth. Additional tools will be provided during the tutorial. The tools provided above should be considered as examples. They all contain the 10 benefits outlined ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168638

    authors: Schilling RB

    更新日期:1997-08-01 00:00:00

  • Efficacy of a checklist-style structured radiology reporting template in reducing resident misses on cervical spine computed tomography examinations.

    abstract::The increasing use of medical checklists to promote patient safety raises the question of their utility in diagnostic radiology. This study evaluates the efficacy of a checklist-style reporting template in reducing resident misses on cervical spine CT examinations. A checklist-style reporting template for cervical spi...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-014-9703-2

    authors: Lin E,Powell DK,Kagetsu NJ

    更新日期:2014-10-01 00:00:00

  • MRI Radiomics for the Prediction of Fuhrman Grade in Clear Cell Renal Cell Carcinoma: a Machine Learning Exploratory Study.

    abstract::The Fuhrman nuclear grade is a recognized prognostic factor for patients with clear cell renal cell carcinoma (CCRCC) and its pre-treatment evaluation significantly affects decision-making in terms of management. In this study, we aimed to assess the feasibility of a combined approach of radiomics and machine learning...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-020-00336-y

    authors: Stanzione A,Ricciardi C,Cuocolo R,Romeo V,Petrone J,Sarnataro M,Mainenti PP,Improta G,De Rosa F,Insabato L,Brunetti A,Maurea S

    更新日期:2020-08-01 00:00:00

  • A heuristic approach to automated nipple detection in digital mammograms.

    abstract::In this paper, a heuristic approach to automated nipple detection in digital mammograms is presented. A multithresholding algorithm is first applied to segment the mammogram and separate the breast region from the background region. Next, the problem is considered separately for craniocaudal (CC) and mediolateral-obli...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9575-x

    authors: Jas M,Mukhopadhyay S,Chakraborty J,Sadhu A,Khandelwal N

    更新日期:2013-10-01 00:00:00

  • A Decision-Support Tool for Renal Mass Classification.

    abstract::We investigate the viability of statistical relational machine learning algorithms for the task of identifying malignancy of renal masses using radiomics-based imaging features. Features characterizing the texture, signal intensity, and other relevant metrics of the renal mass were extracted from multiphase contrast-e...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0100-0

    authors: Kunapuli G,Varghese BA,Ganapathy P,Desai B,Cen S,Aron M,Gill I,Duddalwar V

    更新日期:2018-12-01 00:00:00

  • An Audio/Video Reporting Workflow to Supplement Standardized Radiology Reports.

    abstract::Radiology studies are inherently visual and the information contained within is best conveyed by visual methodology. Advanced reporting software allows the incorporation of annotated key images into text reports, but such features may be less effective compared with in-person consultations. The use of web technology a...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-015-9821-5

    authors: Balkman JD,Siegel AH

    更新日期:2016-04-01 00:00:00

  • The effect of slice thickness on the assessment of bone defect volumes by the Cavalieri principle using cone beam computed tomography.

    abstract::The purpose of this study was to investigate the possible effects of section thickness on volume estimations obtained by cone beam computed tomography. Intraosseal cavities representing bone defects on vestibular sides of the two dry sheep mandibles were scanned by a cone beam computed tomography system. Consecutive s...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9480-8

    authors: Sezgin OS,Kayıpmaz S,Sahin B

    更新日期:2013-02-01 00:00:00

  • A method for computing general sacroiliac screw corridors based on CT scans of the pelvis.

    abstract::Sacroiliac (SI) joint dislocations and sacral fractures of the pelvis can be stabilized by SI screws; however, screw insertion into a sacral isthmus region is risky for the adjacent neurovascular structures. Therefore, shape analyses of general SI screw corridors or safety zones are of great surgical interest; however...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-010-9327-0

    authors: Noser H,Radetzki F,Stock K,Mendel T

    更新日期:2011-08-01 00:00:00

  • Characterization of monochrome CRT display systems in the field.

    abstract::This article presents a review of image quality assessment methods for monochrome CRTs in the field as opposed to the laboratory. The review includes image quality programs at the University of Washington, the University of Texas at Houston, the University of Michigan, and the University of Arizona. CRT manufacturers ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168851

    authors: Roehrig H,Willis CE,Damento MA

    更新日期:1999-11-01 00:00:00

  • A new family of distance functions for perceptual similarity retrieval of medical images.

    abstract::A long-standing challenge of content-based image retrieval (CBIR) systems is the definition of a suitable distance function to measure the similarity between images in an application context which complies with the human perception of similarity. In this paper, we present a new family of distance functions, called att...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-007-9084-x

    authors: Felipe JC,Traina C Jr,Traina AJ

    更新日期:2009-04-01 00:00:00

  • Towards a repository for standardized medical image and signal case data annotated with ground truth.

    abstract::Validation of medical signal and image processing systems requires quality-assured, representative and generally acknowledged databases accompanied by appropriate reference (ground truth) and clinical metadata, which are composed laboriously for each project and are not shared with the scientific community. In our vis...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9428-4

    authors: Deserno TM,Welter P,Horsch A

    更新日期:2012-04-01 00:00:00

  • Computer-Aided Histopathological Image Analysis Techniques for Automated Nuclear Atypia Scoring of Breast Cancer: a Review.

    abstract::Breast cancer is the most common type of malignancy diagnosed in women. Through early detection and diagnosis, there is a great chance of recovery and thereby reduce the mortality rate. Many preliminary tests like non-invasive radiological diagnosis using ultrasound, mammography, and MRI are widely used for the diagno...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-019-00295-z

    authors: Das A,Nair MS,Peter SD

    更新日期:2020-10-01 00:00:00

  • Characterization of radiologists' search strategies for lung nodule detection: slice-based versus volumetric displays.

    abstract::The goal of this study was to assess whether radiologists' search paths for lung nodule detection in chest computed tomography (CT) between different rendering and display schemes have reliable properties that can be exploited as an indicator of ergonomic efficiency for the purpose of comparing different display parad...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-007-9076-x

    authors: Wang XH,Durick JE,Lu A,Herbert DL,Golla SK,Foley K,Piracha CS,Shinde DD,Shindel BE,Fuhrman CR,Britton CA,Strollo DC,Shang SS,Lacomis JM,Good WF

    更新日期:2008-10-01 00:00:00

  • Automated routing of DICOM CT, MR, and CR images: solving the pitfalls of vendor-specific DICOM implementations.

    abstract::This paper details our experience in developing and implementing an automated DICOM Image Router. This workstation serves as a gateway between image acquisition devices and image display and storage devices. Images are checked for demographic input errors and data format inconsistencies between the source and destinat...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168283

    authors: Junck KL,McEachern M,Grandhi S,Lewey G

    更新日期:1998-08-01 00:00:00

  • Estimation of Radiation Dose in CT Based on Projection Data.

    abstract::Managing and optimizing radiation dose has become a core problem for the CT community. As a fundamental step for dose optimization, accurate and computationally efficient dose estimates are crucial. The purpose of this study was to devise a computationally efficient projection-based dose metric. The absorbed energy an...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-016-9869-x

    authors: Tian X,Yin Z,De Man B,Samei E

    更新日期:2016-10-01 00:00:00

  • Detection of microcalcifications by means of multiscale methods and statistical techniques.

    abstract::The detection of clustered microcalcifications can help the radiologist to detect early breast cancer. Microcalcifications exhibit some important characteristics, such as small size and high luminosity. Use of a computer-aided diagnosis (CAD) method can prevent them being overlooked. In this report, a multiresolution ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167672

    authors: Mata Campos R,Vidal EM,Nava E,Martínez-Morillo M,Sendra F

    更新日期:2000-05-01 00:00:00

  • Understanding Clinical Mammographic Breast Density Assessment: a Deep Learning Perspective.

    abstract::Mammographic breast density has been established as an independent risk marker for developing breast cancer. Breast density assessment is a routine clinical need in breast cancer screening and current standard is using the Breast Imaging and Reporting Data System (BI-RADS) criteria including four qualitative categorie...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-017-0022-2

    authors: Mohamed AA,Luo Y,Peng H,Jankowitz RC,Wu S

    更新日期:2018-08-01 00:00:00

  • Displaying radiologic images on personal computers.

    abstract::This is the second article of our series for radiologists and imaging scientists on displaying, manipulating, and analyzing radiologic images on personal computers (PCs). The first article discussed the digital image data file, standard PC graphic file formats, and various methods for importing radiologic images into ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168488

    authors: Gillespy T 3rd,Rowberg AH

    更新日期:1993-08-01 00:00:00

  • Sophisticated hospital information system/radiology information system/picture archiving and communications system (PACS) integration in a large-scale traumatology PACS.

    abstract::Picture archiving and communications system (PACS) in the context of an outpatient trauma care center asks for a high level of interaction between information systems to guarantee rapid image acquisition and distribution to the surgeon. During installation of the Innsbruck PACS, special aspects of traumatology had to ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168769

    authors: Peer S,Vogl R,Peer R,Jaschke W

    更新日期:1999-05-01 00:00:00