Combining fast response and low cost in an intensive care unit viewing station.

Abstract:

:This paper describes a prototype viewing station for the Intensive Care Unit (ICU) that combines a low cost with a fast response for the primary viewing tasks. A single monitor is used together with the possibility to switch to another image on the same screen instantaneously. To reduce the time for image retrieval and display, the viewing station anticipates the need for particular images, and preloads these from the disk into the internal memory whenever the computer has some idle time. Preliminary experience suggests that the use of a single monitor is no fundamental limitation for this application. Most of the time, the system can anticipate which images will be required shortly. This has an important impact on the user efficiency.

journal_name

J Digit Imaging

authors

Bellon E,Houtput W,Bijnens B,Suetens P,Marchal G,Lauwers P

doi

10.1007/BF03168429

subject

Has Abstract

pub_date

1994-05-01 00:00:00

pages

91-4

issue

2

eissn

0897-1889

issn

1618-727X

journal_volume

7

pub_type

杂志文章
  • Adding a microcomputer bar-code network to a minicomputer-based radiology information system.

    abstract::A bar-code terminal network under software control of a microcomputer was added to the minicomputer-based radiology information system at the Medical College of Georgia in Augusta. The bar-code network was specifically installed to address the inherent inaccuracies occurring when procedure information was entered at t...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168107

    authors: David G,Gregory S

    更新日期:1990-02-01 00:00:00

  • An artificial immune-activated neural network applied to brain 3D MRI segmentation.

    abstract::In this paper, a new neural network model inspired by the biological immune system functions is presented. The model, termed Artificial Immune-Activated Neural Network (AIANN), extracts classification knowledge from a training data set, which is then used to classify input patterns or vectors. The AIANN is based on a ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-007-9081-0

    authors: Younis A,Ibrahim M,Kabuka M,John N

    更新日期:2008-10-01 00:00:00

  • DEWEY: the DICOM-enabled workflow engine system.

    abstract::Workflow is a widely used term to describe the sequence of steps to accomplish a task. The use of workflow technology in medicine and medical imaging in particular is limited. In this article, we describe the application of a workflow engine to improve workflow in a radiology department. We implemented a DICOM-enabled...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9661-0

    authors: Erickson BJ,Langer SG,Blezek DJ,Ryan WJ,French TL

    更新日期:2014-06-01 00:00:00

  • Research and teaching access to a large clinical picture archiving and communication system.

    abstract:PURPOSE:To identify practical issues surrounding delivering digital images from picture archiving and communication systems (PACS) for research and teaching purposes. The complexity of Digital Imaging and Communications in Medicine (DICOM) access methods, security, patient confidentiality, PACS database integrity, port...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03190313

    authors: Harrison M,Koh J,Tran S,Mongkolwat P,Channin DS

    更新日期:2001-06-01 00:00:00

  • MABAL: a Novel Deep-Learning Architecture for Machine-Assisted Bone Age Labeling.

    abstract::Bone age assessment (BAA) is a commonly performed diagnostic study in pediatric radiology to assess skeletal maturity. The most commonly utilized method for assessment of BAA is the Greulich and Pyle method (Pediatr Radiol 46.9:1269-1274, 2016; Arch Dis Child 81.2:172-173, 1999) atlas. The evaluation of BAA can be a t...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0053-3

    authors: Mutasa S,Chang PD,Ruzal-Shapiro C,Ayyala R

    更新日期:2018-08-01 00:00:00

  • New picture archiving and communications system plus new facility equals critical path planning challenge.

    abstract::The architectural design and construction of a new imaging department is one of the most complex challenges in healthcare architecture. When a client also plans a simultaneous change in basic operating system technology from film-based to filmless imaging, the challenge for both hospital management and the facility/te...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168779

    authors: Brye PE,Loharikar R,Duda E

    更新日期:1999-05-01 00:00:00

  • An algorithm for automatic segmentation and classification of magnetic resonance brain images.

    abstract::In this article, we describe the development and validation of an automatic algorithm to segment brain from extracranial tissues, and to classify intracranial tissues as cerebrospinal fluid (CSF), gray matter (GM), white matter (WM) or pathology. T1 weighted spin echo, dual echo fast spin echo (T2 weighted and proton ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168729

    authors: Erickson BJ,Avula RT

    更新日期:1998-05-01 00:00:00

  • White matter fiber tracking computation based on diffusion tensor imaging for clinical applications.

    abstract::Fiber tracking allows the in vivo reconstruction of human brain white matter fiber trajectories based on magnetic resonance diffusion tensor imaging (MR-DTI), but its application in the clinical routine is still in its infancy. In this study, we present a new software for fiber tracking, developed on top of a general-...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-0773-7

    authors: Dellani PR,Glaser M,Wille PR,Vucurevic G,Stadie A,Bauermann T,Tropine A,Perneczky A,von Wangenheim A,Stoeter P

    更新日期:2007-03-01 00:00:00

  • A Feasibility Study of Smartphone-Based Telesonography for Evaluating Cardiac Dynamic Function and Diagnosing Acute Appendicitis with Control of the Image Quality of the Transmitted Videos.

    abstract::Our aim was to prove the feasibility of the remote interpretation of real-time transmitted ultrasound videos of dynamic and static organs using a smartphone with control of the image quality given a limited internet connection speed. For this study, 100 cases of echocardiography videos (dynamic organ)-50 with an eject...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-015-9849-6

    authors: Kim C,Cha H,Kang BS,Choi HJ,Lim TH,Oh J

    更新日期:2016-06-01 00:00:00

  • A Decision-Support Tool for Renal Mass Classification.

    abstract::We investigate the viability of statistical relational machine learning algorithms for the task of identifying malignancy of renal masses using radiomics-based imaging features. Features characterizing the texture, signal intensity, and other relevant metrics of the renal mass were extracted from multiphase contrast-e...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0100-0

    authors: Kunapuli G,Varghese BA,Ganapathy P,Desai B,Cen S,Aron M,Gill I,Duddalwar V

    更新日期:2018-12-01 00:00:00

  • NIRViz: 3D visualization software for multimodality optical imaging using visualization toolkit (VTK) and insight segmentation toolkit (ITK).

    abstract::Optical imaging using near-infrared light is used for noninvasive probing of tissues to recover vascular and molecular status of healthy and diseased tissues using hemoglobin contrast arising due to absorption of light. While multimodality optical techniques exist, visualization techniques in this area are limited. Ad...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9362-5

    authors: Taka SJ,Srinivasan S

    更新日期:2011-12-01 00:00:00

  • Online availability check of teleradiology components.

    abstract::For a region-wide teleradiology network in Germany a vendor-independent Uptime-server concept was defined. The Uptime-server was realized for the availability check and prospective error-detection of the emergency teleradiology servers and clients based on encrypted digital imaging and communication in medicine (DICOM...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-1044-3

    authors: Weisser G,Ruggiero S,Runa A,Düber C,Neff W,Walz M

    更新日期:2007-12-01 00:00:00

  • Displaying radiologic images on personal computers.

    abstract::This is the second article of our series for radiologists and imaging scientists on displaying, manipulating, and analyzing radiologic images on personal computers (PCs). The first article discussed the digital image data file, standard PC graphic file formats, and various methods for importing radiologic images into ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168488

    authors: Gillespy T 3rd,Rowberg AH

    更新日期:1993-08-01 00:00:00

  • Can the documented patient briefing be carried out with an iPad app?

    abstract::To evaluate the feasibility of an iPad-based documented patient briefing for Magnetic Resonance Imaging (MRI) examinations. A standard briefing sheet and questionnaire for a MRI scan was converted from paper form into an iPad application. Twenty patients, who had been referred for an MRI scan, were briefed about the e...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9560-9

    authors: Schlechtweg PM,Hammon M,Heberlein C,Giese D,Uder M,Schwab SA

    更新日期:2013-06-01 00:00:00

  • Medical image file formats.

    abstract::Image file format is often a confusing aspect for someone wishing to process medical images. This article presents a demystifying overview of the major file formats currently used in medical imaging: Analyze, Neuroimaging Informatics Technology Initiative (Nifti), Minc, and Digital Imaging and Communications in Medici...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-013-9657-9

    authors: Larobina M,Murino L

    更新日期:2014-04-01 00:00:00

  • Design of a high-speed, high-resolution teleradiology network.

    abstract::A teleradiology system acquires radiographic images from one location and transmits them to one or more distant sites where they are displayed and/or converted to hard-copy film recordings. The long-term goal of teleradiology research is to show that teleradiology systems can provide diagnostically equivalent results ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167763

    authors: Stewart BK,Dwyer SJ 3rd,Kangarloo H

    更新日期:1992-08-01 00:00:00

  • Using the Microsoft Kinect for patient size estimation and radiation dose normalization: proof of concept and initial validation.

    abstract::Monitoring patients' imaging-related radiation is currently a hot topic, but there are many obstacles to accurate, patient-specific dose estimation. While some, such as easier access to dose data and parameters, have been overcome, the challenge remains as to how accurately these dose estimates reflect the actual dose...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9567-2

    authors: Cook TS,Couch G,Couch TJ,Kim W,Boonn WW

    更新日期:2013-08-01 00:00:00

  • Early lung cancer detection using the self-evaluation scoring questionnaire and chest digital radiography: a 3-year follow-up study in China.

    abstract::The standard definition of high-risk individuals for lung cancer was not uniform and the value of chest digital radiography (DR) in lung cancer screening was still unproven. The aim of this study was to assess whether the original questionnaire named as "Self-evaluation Scoring Questionnaire for High-risk Individuals ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9468-4

    authors: Chen B,Wang Y,Cao H,Liu D,Zhang S,Gao J,Yu J,Huang Y,Li W

    更新日期:2013-02-01 00:00:00

  • Classification of hypervascular liver lesions based on hepatic artery and portal vein blood supply coefficients calculated from triphasic CT scans.

    abstract::Perfusion CT of the liver typically involves scanning the liver at least 20 times, resulting in a large radiation dose. We developed and validated a simplified model of tumor blood supply that can be applied to standard triphasic scans and evaluated whether this can be used to distinguish benign and malignant liver le...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-014-9725-9

    authors: Boas FE,Kamaya A,Do B,Desser TS,Beaulieu CF,Vasanawala SS,Hwang GL,Sze DY

    更新日期:2015-04-01 00:00:00

  • Application of temporal subtraction for detection of interval changes on chest radiographs: improvement of subtraction images using automated initial image matching.

    abstract::The authors developed a temporal subtraction scheme based on a nonlinear geometric warping technique to assist radiologists in the detection of interval changes in chest radiographs obtained on different occasions. The performance of the current temporal subtraction scheme is reasonably good; however, severe misregist...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168846

    authors: Ishida T,Ashizawa K,Engelmann R,Katsuragawa S,MacMahon H,Doi K

    更新日期:1999-05-01 00:00:00

  • Panoramic dental radiography using a charge-coupled device receptor.

    abstract::Panoramic radiography using a slit beam and film/screen receptor is standard for the emergency room evaluation of mandibular fractures and also in dentistry. This study compared the spatial resolution, area distortion factors, and the dosage considerations for a panoramic system where standard film/screen and a charge...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168293

    authors: Farman AG,Farman TT

    更新日期:1998-08-01 00:00:00

  • Artifacts found during quality assurance testing of computed radiography and digital radiography detectors.

    abstract::A series of artifact images, obtained over 5 years of performance testing, of both computed radiography (CR) and integrated digital radiographic X-ray imaging detectors are presented. The images presented are all either flat field or test object images and show artifacts previously either undescribed in the existing l...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-008-9109-0

    authors: Honey ID,Mackenzie A

    更新日期:2009-08-01 00:00:00

  • A IHE-Like Approach Method for Quantitative Analysis of PACS Usage.

    abstract::Today, many hospitals have a running enterprise picture archiving and communication system (PACS) and their administrators should have the tools to measure the system activity and, in particular, how much it is used. The information would be valuable for decision-makers to address asset management and the development ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-016-9870-4

    authors: Calabrese R,Beltrame M,Accardo A

    更新日期:2016-12-01 00:00:00

  • Effect of Interventional Program on the Utilization of PACS in Point-of-Care Ultrasound.

    abstract::While the implementation of Picture Archiving and Communication Systems (PACS) has revolutionized the field of radiology, there has been considerably less utilization of PACS by emergency physicians with point-of-care ultrasound. Benefits of PACS archival of images include improved quality assurance, preservation of i...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-016-9893-x

    authors: Kessler R,Stowell JR,Vogel JA,Liao MM,Kendall JL

    更新日期:2016-12-01 00:00:00

  • Solution for nonuniformities and spatial noise in medical LCD displays by using pixel-based correction.

    abstract::Liquid crystal displays (LCD) are rapidly replacing cathode ray tube displays (CRT) for medical imaging. LCD technology has improved significantly in the last few years and has important advantages over CRT. However, there are still some aspects of LCD that raise questions as to the usefulness of liquid crystal displa...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-005-2939-0

    authors: Kimpe T,Xthona A,Matthijs P,De Paepe L

    更新日期:2005-09-01 00:00:00

  • Computer-aided detection scheme for sentinel lymph nodes in lymphoscintigrams using symmetrical property around mapped injection point.

    abstract::It is difficult to detect sentinel lymph nodes (SLNs) around an injection point of radiopharmaceuticals mapped in lymphoscintigrams. The purpose of this study was to develop a computer-aided detection (CAD) scheme for SLNs by a subtraction technique using the symmetrical property in the mapped injection point. Our dat...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9396-8

    authors: Nakayama R,Hizukuri A,Yamamoto K,Nakako N,Nagasawa N,Takeda K

    更新日期:2012-02-01 00:00:00

  • Imaging Informatics Fellowship Curriculum: a Survey to Identify Core Topics and Potential Inter-Program Areas of Collaboration.

    abstract::New consumer technologies and interoperability standards have dated the first standardized curriculum for imaging informatics fellowships suggested by the Society for Computer Applications in Radiology (SCAR) in 2004 (Journal of digital imaging 17(4):244-248, 2004). Last year, analysis from this institution characteri...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00292-2

    authors: Makeeva V,Vey B,Cook TS,Nagy P,Filice RW,Wang KC,Balthazar P,Harri P,Safdar NM

    更新日期:2020-04-01 00:00:00

  • Toward Automatic Detection of Radiation-Induced Cerebral Microbleeds Using a 3D Deep Residual Network.

    abstract::Cerebral microbleeds, which are small focal hemorrhages in the brain that are prevalent in many diseases, are gaining increasing attention due to their potential as surrogate markers of disease burden, clinical outcomes, and delayed effects of therapy. Manual detection is laborious and automatic detection and labeling...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0146-z

    authors: Chen Y,Villanueva-Meyer JE,Morrison MA,Lupo JM

    更新日期:2019-10-01 00:00:00

  • Indexing thoracic CT reports using a preliminary version of a standardized radiological lexicon (RadLex).

    abstract:INTRODUCTION:To validate a preliminary version of a radiological lexicon (RadLex) against terms found in thoracic CT reports and to index report content in RadLex term categories. MATERIAL AND METHODS:Terms from a random sample of 200 thoracic CT reports were extracted using a text processor and matched against RadLex...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-007-9051-6

    authors: Marwede D,Schulz T,Kahn T

    更新日期:2008-12-01 00:00:00

  • Can an Offsite Expert Remotely Evaluate the Visual Estimation of Ejection Fraction via a Social Network Video Call?

    abstract::We aimed to investigate whether an offsite expert could effectively evaluate visually estimated ejection fraction (EF) while watching and guiding the echocardiographic procedure of an onsite novice practitioner using a social network video call. Sixty patients presenting to the intensive care unit and requiring echoca...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-017-9974-5

    authors: Kim C,Hur J,Kang BS,Choi HJ,Shin JH,Kim TH,Chung JH

    更新日期:2017-12-01 00:00:00