Abstract:
:Our aim was to prove the feasibility of the remote interpretation of real-time transmitted ultrasound videos of dynamic and static organs using a smartphone with control of the image quality given a limited internet connection speed. For this study, 100 cases of echocardiography videos (dynamic organ)-50 with an ejection fraction (EF) of ≥50 s and 50 with EF <50 %-and 100 cases of suspected pediatric appendicitis (static organ)-50 with signs of acute appendicitis and 50 with no findings of appendicitis-were consecutively selected. Twelve reviewers reviewed the original videos using the liquid crystal display (LCD) monitor of an ultrasound machine and using a smartphone, to which the images were transmitted from the ultrasound machine. The resolution of the transmitted echocardiography videos was reduced by approximately 20 % to increase the frame rate of transmission given the limited internet speed. The differences in diagnostic performance between the two devices when evaluating left ventricular (LV) systolic function by measuring the EF and when evaluating the presence of acute appendicitis were investigated using a five-point Likert scale. The average areas under the receiver operating characteristic curves for each reviewer's interpretations using the LCD monitor and smartphone were respectively 0.968 (0.949-0.986) and 0.963 (0.945-0.982) (P = 0.548) for echocardiography and 0.972 (0.954-0.989) and 0.966 (0.947-0.984) (P = 0.175) for abdominal ultrasonography. We confirmed the feasibility of remotely interpreting ultrasound images using smartphones, specifically for evaluating LV function and diagnosing pediatric acute appendicitis; the images were transferred from the ultrasound machine using image quality-controlled telesonography.
journal_name
J Digit Imagingjournal_title
Journal of digital imagingauthors
Kim C,Cha H,Kang BS,Choi HJ,Lim TH,Oh Jdoi
10.1007/s10278-015-9849-6subject
Has Abstractpub_date
2016-06-01 00:00:00pages
347-56issue
3eissn
0897-1889issn
1618-727Xpii
10.1007/s10278-015-9849-6journal_volume
29pub_type
杂志文章abstract::Rapid advances are changing the technology and applications of multidetector computed tomography (CT) scanners. The major increase in data associated with this new technology, however, breaks most commercial picture archiving and communication system (PACS) architectures by preventing them from delivering data in real...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-006-0925-9
更新日期:2006-01-01 00:00:00
abstract::Web educational resources integrating interactive simulation tools provide students with an in-depth understanding of the medical imaging process. The aim of this work was the development of a purely Web-based, open access, interactive application, as an ancillary learning tool in graduate and postgraduate medical ima...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-014-9689-9
更新日期:2015-02-01 00:00:00
abstract::The objective of this study was to determine the differential cost between film-based radiology and a hospital-wide picture archiving and communication system (PACS) implemented all at once. The cash flow and running costs of PACS and film-based operation were measured over an 8-year time horizon. When the hospital-wi...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-006-0632-6
更新日期:2006-01-01 00:00:00
abstract::In this report, a novel technique is proposed for computer-aided automatic extraction of microcalcifications in a digital mammogram. First, the microcalcifications are detected by morphological filtering, followed by entropy-based thresholding. Next, the microcalcifications are segmented by computing regional watershe...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03167642
更新日期:2000-05-01 00:00:00
abstract::We evaluated the usefulness of a computerized analysis system in the detection of interstitial lung abnormalities in digitized chest radiography. This system uses the processes of four-directional Laplacian-Gaussian filtering, linear opacity judgment, and linear opacity subtraction. For qualitative analysis, we employ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168557
更新日期:1997-05-01 00:00:00
abstract::In this investigation the effect of JPEG 2000 compression on the contrast-detail (CD) characteristics of digital mammography images was studied using an alternative forced choice (AFC) technique. Images of a contrast-detail phantom, acquired using a clinical full-field digital mammography system, were compressed using...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-003-1728-x
更新日期:2004-03-01 00:00:00
abstract::In today's radiology workflow, free-text reporting is established as the most common medium to capture, store, and communicate clinical information. Radiologists routinely refer to prior radiology reports of a patient to recall critical information for new diagnosis, which is quite tedious, time consuming, and prone t...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-018-0116-5
更新日期:2019-02-01 00:00:00
abstract::Breast masses due to benign disease and malignant tumors related to breast cancer differ in terms of shape, edge-sharpness, and texture characteristics. In this study, we evaluate a set of 22 features including 5 shape factors, 3 edge-sharpness measures, and 14 texture features computed from 111 regions in mammograms,...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-007-9102-z
更新日期:2008-06-01 00:00:00
abstract::The purpose of this communication is to report on the testing of the disaster recovery capability of our hierarchical storage management (HSM) system. Disaster recovery implementation is a requirement of every mission-critical information technology project. Picture archiving and communications systems (PACS) certainl...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03167652
更新日期:2000-05-01 00:00:00
abstract::Mammographic breast density has been established as an independent risk marker for developing breast cancer. Breast density assessment is a routine clinical need in breast cancer screening and current standard is using the Breast Imaging and Reporting Data System (BI-RADS) criteria including four qualitative categorie...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-017-0022-2
更新日期:2018-08-01 00:00:00
abstract::This article describes an application for capturing, delivering, and tracking urgent radiology exam results. Urgent exam findings are entered using a Web form embedded within the Picture archiving and communication system (PACS) display station. The findings are then accessible via soft copy using the PACS display sta...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-003-1717-0
更新日期:2004-06-01 00:00:00
abstract::This is the fifth and final article in our series for radiologists and imaging scientists on displaying, manipulating, and analyzing radiologic images on personal computers (PCs). There are many methods of transferring radiologic images into a PC, including transfer over a network, transfer from an imaging modality st...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168502
更新日期:1994-08-01 00:00:00
abstract::In this work, two different approaches are proposed for region of interest (ROI) segmentation using transrectal ultrasound (TRUS) images. The two methods aim to extract informative features that are able to characterize suspicious regions in the TRUS images. Both proposed methods are based on multi-resolution analysis...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-008-9124-1
更新日期:2009-10-01 00:00:00
abstract::Lung cancer has the highest mortality rate of all cancers, and early detection can improve survival rates. In the recent years, low-dose CT has been widely used to detect lung cancer. However, the diagnosis is limited by the subjective experience of doctors. Therefore, the main purpose of this study is to use convolut...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-020-00333-1
更新日期:2020-08-01 00:00:00
abstract::This paper presents our solution for supporting radiologists' interpretation of digital images by automating image presentation during sequential interpretation steps. We extended current hanging protocols with support for "stages" which reflect the presentation of digital information required to complete a single ste...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-004-1906-5
更新日期:2005-06-01 00:00:00
abstract::Today, many hospitals have a running enterprise picture archiving and communication system (PACS) and their administrators should have the tools to measure the system activity and, in particular, how much it is used. The information would be valuable for decision-makers to address asset management and the development ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-016-9870-4
更新日期:2016-12-01 00:00:00
abstract::As resources in the healthcare environment continue to wane, leaders are seeking ways to continue to provide quality care bounded by the constraints of a reduced budget. This manuscript synthesizes the experience from a number of institutions to provide the healthcare leadership with an understanding of the value of a...
journal_title:Journal of digital imaging
pub_type: 杂志文章,评审
doi:10.1007/s10278-019-00293-1
更新日期:2020-02-01 00:00:00
abstract::There is increasing prevalence of digital diagnostic imaging in veterinary medicine with a progressive need to use medical imaging software. As Digital Imaging and Communications in Medicine (DICOM)-viewers for veterinary use do not require medical device approval in many countries, freeware viewers might be a practic...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-019-00194-3
更新日期:2020-02-01 00:00:00
abstract::Workflow is a widely used term to describe the sequence of steps to accomplish a task. The use of workflow technology in medicine and medical imaging in particular is limited. In this article, we describe the application of a workflow engine to improve workflow in a radiology department. We implemented a DICOM-enabled...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-013-9661-0
更新日期:2014-06-01 00:00:00
abstract::Digital imaging systems used in radiology rely on electronic display devices to present images to human observers. Active-matrix liquid crystal displays (AMLCDs) continue to improve and are beginning to be considered for diagnostic image display. In spite of recent progress, AMLCDs are characterized by a change in lum...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-004-1021-7
更新日期:2004-12-01 00:00:00
abstract::The objective of this study is to retrospectively investigate whether using the newly developed algorithms would improve radiologists' accuracy for discriminating malignant masses from benign ones on ultrasonographic (US) images. Five radiologists blinded to the histological results and clinical history independently ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-009-9245-1
更新日期:2010-10-01 00:00:00
abstract::This article describes the design and implementation of a low-cost image archival and management solution on a radiology network consisting of UNIX, IBM personal computer-compatible (IBM, Purchase, NY) and Macintosh (Apple Computer, Cupertino, CA) workstations. The picture archiving and communications system (PACS) is...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168688
更新日期:1997-08-01 00:00:00
abstract::Complex deformities of the spine, like scoliosis, are evaluated more precisely using stereo-radiographic 3D reconstruction techniques. Primarily, it uses six stereo-corresponding points available on the vertebral body for the 3D reconstruction of each vertebra. The wireframe structure obtained in this process has poor...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-015-9841-1
更新日期:2016-04-01 00:00:00
abstract::Surface morphology and shape in general are important predictors for the behavior of solid-type lung nodules detected on CT. More broadly, shape analysis is useful in many areas of computer-aided diagnosis and essentially all scientific and engineering disciplines. Automated methods for shape detection have all previo...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-014-9732-x
更新日期:2015-04-01 00:00:00
abstract::As hospitals convert from conventional image processing to picture archiving and communication systems (PACS) technology, new job opportunities arose for PACS analysts, PACS system administrators, PACS operators, and PACS trainers. To support a PACS, these positions require education in computer information systems an...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-002-5095-9
更新日期:2002-01-01 00:00:00
abstract::Positron emission tomography (PET) imaging is an effective tool used in determining disease stage and lesion malignancy; however, radiation exposure to patients and technicians during PET scans continues to draw concern. One way to minimize radiation exposure is to reduce the dose of radioactive tracer administered in...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-018-0150-3
更新日期:2019-10-01 00:00:00
abstract::An integrated picture archiving and communication system (PACS) is a large investment in both money and resources. With all of the components and systems contained in the PACS, a methodical set of protocols and procedures must be developed to test all aspects of the PACS within the short time allocated for contract co...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168789
更新日期:1999-05-01 00:00:00
abstract::Extensive research efforts have been devoted to the feasibility of picture archiving and communication systems (PACS) in recent years. The advantages of PACS are numerous but mainly include reduced cost and improvement in the operational efficiency of a PACS-based radiology department. In digital radiography, images a...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168839
更新日期:1997-11-01 00:00:00
abstract::Computed radiography of chest with a 4K image array was recently introduced. We performed a multiobserver study to compare the diagnostic accuracy of 2K (standard) and 4K (high quality) chest radiographs displayed on a 5-mega-pixel monitor (2K monitor). One hundred cases of posteroanterior chest radiographs (a total o...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-006-1048-z
更新日期:2007-12-01 00:00:00
abstract::Functional near-infrared spectroscopy (fNIRS) is a relatively new imaging modality in the functional neuroimaging research arena. The fNIRS modality non-invasively investigates the change of blood oxygenation level in the human brain utilizing the transillumination technique. In the last two decades, the interest in t...
journal_title:Journal of digital imaging
pub_type: 杂志文章,评审
doi:10.1007/s10278-020-00387-1
更新日期:2020-10-01 00:00:00