Abstract:
:Teleradiology applications often use an interactive conferencing mode with remote control mouse pointers. When a telephone is used for voice communication, latencies of the data network can create a temporal discrepancy between the position of the mouse pointer and the verbal communication. To assess the effects of this dissociation, we examined the performance of 5 test persons carrying out simple teleradiology tasks under varying simulated network conditions. When the network latency exceeded 400 milliseconds, the performance of the test persons dropped, and an increasing number of errors were made. This effect was the same for constant latencies, which can occur on the network path, and for variable delays caused by the Nagle algorithm, an internal buffering scheme used by the TCP/IP protocol. Because the Nagle algorithm used in typical TCP/IP implementations causes a latency of about 300 milliseconds even before a data packet is sent, any additional latency in the network of 100 milliseconds or more will result in a decreased operator performance in teleradiology applications. These conditions frequently occur on the public Internet or on overseas connections. For optimal performance, the authors recommend bypassing the Nagle algorithm in teleradiology applications.
journal_name
J Digit Imagingjournal_title
Journal of digital imagingauthors
Stahl JN,Tellis W,Huang HKdoi
10.1007/BF03168384subject
Has Abstractpub_date
2000-08-01 00:00:00pages
119-23issue
3eissn
0897-1889issn
1618-727Xjournal_volume
13pub_type
杂志文章abstract::To illustrate the availability, effectiveness, and practical use of Open-Source tools in developing a radiology paper from its beginning to its presentation and publication. Practical use of a complete set of Open-Source applications for writing, e-mail corresponding, slide show, image retrieval, and manipulation is s...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-008-9159-3
更新日期:2009-12-01 00:00:00
abstract::The standard definition of high-risk individuals for lung cancer was not uniform and the value of chest digital radiography (DR) in lung cancer screening was still unproven. The aim of this study was to assess whether the original questionnaire named as "Self-evaluation Scoring Questionnaire for High-risk Individuals ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-012-9468-4
更新日期:2013-02-01 00:00:00
abstract::This is the second article of our series for radiologists and imaging scientists on displaying, manipulating, and analyzing radiologic images on personal computers (PCs). The first article discussed the digital image data file, standard PC graphic file formats, and various methods for importing radiologic images into ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168488
更新日期:1993-08-01 00:00:00
abstract::A C-language software program has been developed for emulating the image enhancement processing of a storage phosphor plate system. This software has been implemented on a VAX 3400 computer. There are 2,100 lines of C-language code in the program. There are seven parameters used to specify the degree of enhancement. T...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03167825
更新日期:1992-02-01 00:00:00
abstract::Several studies have addressed the implications of filmless radiologic imaging on telemedicine, diagnostic ability, and electronic teaching files. However, many publishers still require authors to submit hard-copy images for publication of articles and textbooks. This study compares the quality digital images directly...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-001-0019-7
更新日期:2001-03-01 00:00:00
abstract::Web educational resources integrating interactive simulation tools provide students with an in-depth understanding of the medical imaging process. The aim of this work was the development of a purely Web-based, open access, interactive application, as an ancillary learning tool in graduate and postgraduate medical ima...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-014-9689-9
更新日期:2015-02-01 00:00:00
abstract::A 10-bit or 12-bit gray scale is provided in commercial laser film digitizers. The true contrast resolution on the digitized image within a laser spot area of 200 microns in diameter is limited by both the quantum mottle and instrumentation noise. In this report, we investigated the mean value, standard deviation, and...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03170571
更新日期:1990-05-01 00:00:00
abstract::Voice recognition (VR) and picture archiving and communication system (PACS) both have advantages and disadvantages in radiologic practice. We describe a fully integrated VR/PACS system running on a single platform. Integration optimizes the positive features of both systems and creates a synergy that is not otherwise...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03190351
更新日期:2001-06-01 00:00:00
abstract::Clinical picture archiving and communications systems provide convenient, efficient access to digital medical images from multiple modalities but can prove challenging to deploy, configure and use. MRIdb is a self-contained image database, particularly suited to the storage and management of magnetic resonance imaging...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-013-9604-9
更新日期:2013-10-01 00:00:00
abstract::Considerable debate within the medical community has focused on the optimal location of information technology (IT) support groups on the organizational chart. The challenge has been to marry local accountability and physician acceptance of IT with the benefits gained by the economies of scale achieved by centralized ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-009-9196-6
更新日期:2009-06-01 00:00:00
abstract::This article describes the design and implementation of a low-cost image archival and management solution on a radiology network consisting of UNIX, IBM personal computer-compatible (IBM, Purchase, NY) and Macintosh (Apple Computer, Cupertino, CA) workstations. The picture archiving and communications system (PACS) is...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168688
更新日期:1997-08-01 00:00:00
abstract::This article presents a review of image quality assessment methods for monochrome CRTs in the field as opposed to the laboratory. The review includes image quality programs at the University of Washington, the University of Texas at Houston, the University of Michigan, and the University of Arizona. CRT manufacturers ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168851
更新日期:1999-11-01 00:00:00
abstract::Academic medical centers, in general, and radiation oncology research, in particular, rely heavily on custom software tools and applications. The code development is typically the responsibility of a single individual or at most a small team. Often these individuals are not professional programmers but physicists, stu...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-009-9271-z
更新日期:2011-02-01 00:00:00
abstract::Electronic imaging clinical implementation strategies and principles need to be developed as we move toward replacement of film-based radiology practices. During an 8-month period (1998 to 1999), an Electronic Imaging Clinical Implementation Work Group (EICIWG) was formed from sections of our department: Informatics L...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168749
更新日期:1999-05-01 00:00:00
abstract::There is continual pressure on the radiology department to increase its productivity. Two important links to productivity in the computed/digital radiography (CR/DR) workflow chain are the postprocessing step by technologists and the primary diagnosis step by radiologists, who may apply additional image enhancements t...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-004-1000-z
更新日期:2004-09-01 00:00:00
abstract::Breast masses due to benign disease and malignant tumors related to breast cancer differ in terms of shape, edge-sharpness, and texture characteristics. In this study, we evaluate a set of 22 features including 5 shape factors, 3 edge-sharpness measures, and 14 texture features computed from 111 regions in mammograms,...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-007-9102-z
更新日期:2008-06-01 00:00:00
abstract::There is increasing prevalence of digital diagnostic imaging in veterinary medicine with a progressive need to use medical imaging software. As Digital Imaging and Communications in Medicine (DICOM)-viewers for veterinary use do not require medical device approval in many countries, freeware viewers might be a practic...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-019-00194-3
更新日期:2020-02-01 00:00:00
abstract::Compared to traditional film radiography, digital radiography is believed to improve workflow and patient throughput. Digital radiography permits the technologist to immediately view the quality of the film directly at the modality. Additional workflow improvements, therefore, should be achieved with the integration o...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03167662
更新日期:2000-05-01 00:00:00
abstract::Efficient data compression is essential for practical daily operation of computed radiography (CR) systems. In this study the clinical applicability of type III irreversible high data compression using an FCR 9501 chest unit (Fuji Photo Film, Tokyo, Japan) was evaluated. Sixty-eight normal and 93 various abnormal case...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03178080
更新日期:1998-11-01 00:00:00
abstract::Positron emission tomography (PET) imaging is an effective tool used in determining disease stage and lesion malignancy; however, radiation exposure to patients and technicians during PET scans continues to draw concern. One way to minimize radiation exposure is to reduce the dose of radioactive tracer administered in...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-018-0150-3
更新日期:2019-10-01 00:00:00
abstract::A long-standing challenge of content-based image retrieval (CBIR) systems is the definition of a suitable distance function to measure the similarity between images in an application context which complies with the human perception of similarity. In this paper, we present a new family of distance functions, called att...
journal_title:Journal of digital imaging
pub_type: 杂志文章,评审
doi:10.1007/s10278-007-9084-x
更新日期:2009-04-01 00:00:00
abstract::A teleradiology system acquires radiographic images from one location and transmits them to one or more distant sites where they are displayed and/or converted to hard-copy film recordings. The long-term goal of teleradiology research is to show that teleradiology systems can provide diagnostically equivalent results ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03167763
更新日期:1992-08-01 00:00:00
abstract::Communicating radiological reports to peers has pedagogical value. Students may be uneasy with the process due to a lack of communication and peer review skills or to their failure to see value in the process. We describe a communication exercise with peer review in an undergraduate veterinary radiology course. The co...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-016-9905-x
更新日期:2017-02-01 00:00:00
abstract::While occupational stress and fatigue have been well described throughout medicine, the radiology community is particularly susceptible due to declining reimbursements, heightened demands for service deliverables, and increasing exam volume and complexity. The resulting occupational stress can be variable in nature an...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-012-9540-0
更新日期:2013-02-01 00:00:00
abstract::The purpose of this study was to investigate the possible effects of section thickness on volume estimations obtained by cone beam computed tomography. Intraosseal cavities representing bone defects on vestibular sides of the two dry sheep mandibles were scanned by a cone beam computed tomography system. Consecutive s...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-012-9480-8
更新日期:2013-02-01 00:00:00
abstract::The goal of this study was to assess whether radiologists' search paths for lung nodule detection in chest computed tomography (CT) between different rendering and display schemes have reliable properties that can be exploited as an indicator of ergonomic efficiency for the purpose of comparing different display parad...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-007-9076-x
更新日期:2008-10-01 00:00:00
abstract::Validation of medical signal and image processing systems requires quality-assured, representative and generally acknowledged databases accompanied by appropriate reference (ground truth) and clinical metadata, which are composed laboriously for each project and are not shared with the scientific community. In our vis...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-011-9428-4
更新日期:2012-04-01 00:00:00
abstract::The purpose of this study was to develop and evaluate a computerized method of calculating a breast density index (BDI) from digitized mammograms that was designed specifically to model radiologists' perception of breast density. A set of 153 pairs of digitized mammograms (cranio-caudal, CC, and mediolateral oblique, ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168733
更新日期:1998-08-01 00:00:00
abstract::The Fuhrman nuclear grade is a recognized prognostic factor for patients with clear cell renal cell carcinoma (CCRCC) and its pre-treatment evaluation significantly affects decision-making in terms of management. In this study, we aimed to assess the feasibility of a combined approach of radiomics and machine learning...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-020-00336-y
更新日期:2020-08-01 00:00:00
abstract::Breast cancer is the most common type of malignancy diagnosed in women. Through early detection and diagnosis, there is a great chance of recovery and thereby reduce the mortality rate. Many preliminary tests like non-invasive radiological diagnosis using ultrasound, mammography, and MRI are widely used for the diagno...
journal_title:Journal of digital imaging
pub_type: 杂志文章,评审
doi:10.1007/s10278-019-00295-z
更新日期:2020-10-01 00:00:00