Analog to digital workflow improvement: a quantitative study.

Abstract:

:This study tracked a radiology department's conversion from utilization of a Kodak Amber analog system to a Kodak DirectView DR 5100 digital system. Through the use of ProModel Optimization Suite, a workflow simulation software package, significant quantitative information was derived from workflow process data measured before and after the change to a digital system. Once the digital room was fully operational and the radiology staff comfortable with the new system, average patient examination time was reduced from 9.24 to 5.28 min, indicating that a higher patient throughput could be achieved. Compared to the analog system, chest examination time for modality specific activities was reduced by 43%. The percentage of repeat examinations experienced with the digital system also decreased to 8% vs. the level of 9.5% experienced with the analog system. The study indicated that it is possible to quantitatively study clinical workflow and productivity by using commercially available software.

journal_name

J Digit Imaging

authors

Wideman C,Gallet J

doi

10.1007/s10278-006-0770-x

subject

Has Abstract

pub_date

2006-01-01 00:00:00

pages

29-34

eissn

0897-1889

issn

1618-727X

journal_volume

19 Suppl 1

pub_type

杂志文章
  • Prostate tissue texture feature extraction for suspicious regions identification on TRUS images.

    abstract::In this work, two different approaches are proposed for region of interest (ROI) segmentation using transrectal ultrasound (TRUS) images. The two methods aim to extract informative features that are able to characterize suspicious regions in the TRUS images. Both proposed methods are based on multi-resolution analysis...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-008-9124-1

    authors: Mohamed SS,Li J,Salama MM,Freeman G

    更新日期:2009-10-01 00:00:00

  • Thresholding histogram equalization.

    abstract::The drawbacks of adaptive histogram equalization techniques are the loss of definition on the edges of the object and overenhancement of noise in the images. These drawbacks can be avoided if the noise is excluded in the equalization transformation function computation. A method has been developed to separate the hist...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-001-0103-z

    authors: Chuang KS,Chen S,Hwang IM

    更新日期:2001-12-01 00:00:00

  • Estimates of Patient Radiation Doses in Digital Radiography Using DICOM Information at a Large Teaching Hospital in Oman.

    abstract::In this study, we sought to estimate the patient radiation doses in the digital radiography X-ray examinations conducted in a large hospital. The patient exposure factors and kerma-area product (PKA) were retrospectively recorded via the Digital Imaging and Communications in Medicine (DICOM) header for 547 patients. T...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00199-y

    authors: Suliman II

    更新日期:2020-02-01 00:00:00

  • App Review Series: CTisus iPearls.

    abstract::Thousands of "pearls" or facts related to radiology or imaging are accessible through a categorically organized user interface. Pearls are divided up into anatomical regions, as well as non-organ-specific categories. Information is easily accessible with an ad-free interface matched with full offline capability. User ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-018-0103-x

    authors: Buro J

    更新日期:2018-12-01 00:00:00

  • Minimizing Digital Imaging and Communications in Medicine (DICOM) Modality Worklist patient/study selection errors.

    abstract::Frequently when patient and study identification information (patient name, patient identification, date of birth, sex, and accession number) are manually entered at a modality, typographical errors occur that have to be corrected before the acquired images can be matched to the proper patient and study on a picture a...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03190323

    authors: Kuzmak PM,Dayhoff RE

    更新日期:2001-06-01 00:00:00

  • Effect of viewing angle on luminance and contrast for a five-million-pixel monochrome display and a nine-million-pixel color liquid crystal display.

    abstract::Digital imaging systems used in radiology rely on electronic display devices to present images to human observers. Active-matrix liquid crystal displays (AMLCDs) continue to improve and are beginning to be considered for diagnostic image display. In spite of recent progress, AMLCDs are characterized by a change in lum...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-004-1021-7

    authors: Fifadara DH,Averbukh A,Channin DS,Badano A

    更新日期:2004-12-01 00:00:00

  • Solution for nonuniformities and spatial noise in medical LCD displays by using pixel-based correction.

    abstract::Liquid crystal displays (LCD) are rapidly replacing cathode ray tube displays (CRT) for medical imaging. LCD technology has improved significantly in the last few years and has important advantages over CRT. However, there are still some aspects of LCD that raise questions as to the usefulness of liquid crystal displa...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-005-2939-0

    authors: Kimpe T,Xthona A,Matthijs P,De Paepe L

    更新日期:2005-09-01 00:00:00

  • A study on the feasibility of active contours on automatic CT bone segmentation.

    abstract::Automatic bone segmentation of computed tomography (CT) images is an important step in image-guided surgery that requires both high accuracy and minimal user interaction. Previous attempts include global thresholding, region growing, region competition, watershed segmentation, and parametric active contour (AC) approa...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-009-9210-z

    authors: Truc PT,Kim TS,Lee S,Lee YK

    更新日期:2010-12-01 00:00:00

  • Optimizing technology development and adoption in medical imaging using the principles of innovation diffusion, part II: practical applications.

    abstract::Successful adoption of new technology development can be accentuated by learning and applying the scientific principles of innovation diffusion. This is of particular importance to areas within the medical imaging practice which have lagged in innovation; perhaps, the most notable of which is reporting which has remai...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-011-9409-7

    authors: Reiner BI

    更新日期:2012-02-01 00:00:00

  • Enhancement of storage phosphor plate images: a C-language program.

    abstract::A C-language software program has been developed for emulating the image enhancement processing of a storage phosphor plate system. This software has been implemented on a VAX 3400 computer. There are 2,100 lines of C-language code in the program. There are seven parameters used to specify the degree of enhancement. T...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167825

    authors: Templeton AW,Wetzel LH,Cook LT,Harrison LA,Eckard DA,Anderson WH,Hensley KS

    更新日期:1992-02-01 00:00:00

  • A Feasibility Study of Smartphone-Based Telesonography for Evaluating Cardiac Dynamic Function and Diagnosing Acute Appendicitis with Control of the Image Quality of the Transmitted Videos.

    abstract::Our aim was to prove the feasibility of the remote interpretation of real-time transmitted ultrasound videos of dynamic and static organs using a smartphone with control of the image quality given a limited internet connection speed. For this study, 100 cases of echocardiography videos (dynamic organ)-50 with an eject...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-015-9849-6

    authors: Kim C,Cha H,Kang BS,Choi HJ,Lim TH,Oh J

    更新日期:2016-06-01 00:00:00

  • Clinical impact of picture archiving and communication systems: evaluation of a prototype system.

    abstract::Opinion surveys were gathered before and 6 months after installation of a prototype picture archiving and communication system (PACS) (PACS/1, Siemens Medical Systems, Iselin, NJ). Median turnaround times and the percent of delayed or missing reports were calculated for 1,026 baseline and 8,438 follow-up studies at 6 ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167836

    authors: Worrell JA,Federspiel CF,Creasy JL,Pickens DR 3rd,Higginbotham K,Patton JA,Partain CL

    更新日期:1992-05-01 00:00:00

  • Interactive image enhancement of CR and DR images.

    abstract::There is continual pressure on the radiology department to increase its productivity. Two important links to productivity in the computed/digital radiography (CR/DR) workflow chain are the postprocessing step by technologists and the primary diagnosis step by radiologists, who may apply additional image enhancements t...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-004-1000-z

    authors: Thomas MA,Rowberg AH,Langer SG,Kim Y

    更新日期:2004-09-01 00:00:00

  • Online Radiology Reporting with Peer Review as a Learning and Feedback Tool in Radiology; Implementation, Validity, and Student Impressions.

    abstract::Communicating radiological reports to peers has pedagogical value. Students may be uneasy with the process due to a lack of communication and peer review skills or to their failure to see value in the process. We describe a communication exercise with peer review in an undergraduate veterinary radiology course. The co...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-016-9905-x

    authors: McEvoy FJ,Shen NW,Nielsen DH,Buelund LE,Holm P

    更新日期:2017-02-01 00:00:00

  • A comparison of hard and soft copies processed with linear conversion and nonlinear conversion of skeletal fractures--a preliminary study.

    abstract::To compare hard copies and soft copies processed with linear and nonlinear conversion of skeletal fractures, we performed a receiver-operating characteristics study of 25 digital radiographs. There was no statistical difference between hard copies with linear and nonlinear conversion. However, it may be difficult to d...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168067

    authors: Kaji T,Katayama M,Kosuda S,Kusano S

    更新日期:1995-02-01 00:00:00

  • CD-based image archival and management on a hybrid radiology intranet.

    abstract::This article describes the design and implementation of a low-cost image archival and management solution on a radiology network consisting of UNIX, IBM personal computer-compatible (IBM, Purchase, NY) and Macintosh (Apple Computer, Cupertino, CA) workstations. The picture archiving and communications system (PACS) is...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168688

    authors: Cox RD,Henri CJ,Bret PM

    更新日期:1997-08-01 00:00:00

  • Stereotactic neurosurgery planning on a personal-computer-based work station.

    abstract::Stereotactic surgery requires knowledge of cerebral structures derived from more than one image source. We have developed a PC-AT-based workstation that accepts patient images, made with the stereotactic frame in place, from CT, MRI, and DSA modalities. Reference markers on the frame are identified in the images to es...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168023

    authors: Peters TM,Clark JA,Pike GB,Henri C,Collins L,Leksell D,Jeppsson O

    更新日期:1989-05-01 00:00:00

  • Designing better radiology workstations: impact of two user interfaces on interpretation errors and user satisfaction.

    abstract::This paper presents our solution for supporting radiologists' interpretation of digital images by automating image presentation during sequential interpretation steps. We extended current hanging protocols with support for "stages" which reflect the presentation of digital information required to complete a single ste...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-004-1906-5

    authors: Moise A,Atkins MS

    更新日期:2005-06-01 00:00:00

  • A Pilot Study on the Development of Remote Quality Control of Digital Mammography Systems in the NHS Breast Screening Programme.

    abstract::In the UK, physicists and radiographers perform routine quality control (QC) of digital mammography equipment at daily, weekly and monthly intervals. The tests performed and tolerances are specified by standard protocols. The manual nature of many of the tests introduces variability due to the positioning of regions o...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-014-9759-z

    authors: Looney P,Halling-Brown MD,Oduko JM,Young KC

    更新日期:2015-10-01 00:00:00

  • Assessing the accuracy factors in the determination of postoperative acetabular cup orientation using hybrid 2D-3D registration.

    abstract::Single standard anteroposterior radiograph-based methods for measuring cup orientation following total hip arthroplasty (THA) are subject to substantial errors if the individual pelvic orientation with respect to X-ray plate is not taken into consideration. Previously, we proposed to use a hybrid 2D-3D registration sc...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-009-9226-4

    authors: Zheng G

    更新日期:2010-12-01 00:00:00

  • Integration of computer-assembled digital images and text data as evidence for the oncological record.

    abstract::Digitally created visual images of pertinent patient data have been integrated with text information to formulate a visual evaluation and summary sheet (VESS) using computer processing. The VESS incorporates images of a patient's physical appearance, radiological images, pharmacokinetic graphs, and text information in...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168369

    authors: Liu JM,Wu HW,Chen WS,Lin WC,Chao Y,Lui WY,Whang-Peng J

    更新日期:2000-05-01 00:00:00

  • Variability of semiautomated lung nodule volumetry on ultralow-dose CT: comparison with nodule volumetry on standard-dose CT.

    abstract::The study investigates the effect of a substantial dose reduction on the variability of lung nodule volume measurements by assessing and comparing nodule volumes using a dedicated semiautomated segmentation software on ultralow-dose computed tomography (ULD-CT) and standard-dose computed tomography (SD-CT) data. In 20...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-008-9157-5

    authors: Hein PA,Romano VC,Rogalla P,Klessen C,Lembcke A,Bornemann L,Dicken V,Hamm B,Bauknecht HC

    更新日期:2010-02-01 00:00:00

  • Improvement in Detection of Wrong-Patient Errors When Radiologists Include Patient Photographs in Their Interpretation of Portable Chest Radiographs.

    abstract::This study was conducted to determine whether facial photographs obtained simultaneously with radiographs improve radiologists' detection rate of wrong-patient errors, when they are explicitly asked to include the photographs in their evaluation. Radiograph-photograph combinations were obtained from 28 patients at the...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-015-9808-2

    authors: Tridandapani S,Olsen K,Bhatti P

    更新日期:2015-12-01 00:00:00

  • Computer-aided detection scheme for sentinel lymph nodes in lymphoscintigrams using symmetrical property around mapped injection point.

    abstract::It is difficult to detect sentinel lymph nodes (SLNs) around an injection point of radiopharmaceuticals mapped in lymphoscintigrams. The purpose of this study was to develop a computer-aided detection (CAD) scheme for SLNs by a subtraction technique using the symmetrical property in the mapped injection point. Our dat...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9396-8

    authors: Nakayama R,Hizukuri A,Yamamoto K,Nakako N,Nagasawa N,Takeda K

    更新日期:2012-02-01 00:00:00

  • A content-boosted collaborative filtering algorithm for personalized training in interpretation of radiological imaging.

    abstract::Devising a method that can select cases based on the performance levels of trainees and the characteristics of cases is essential for developing a personalized training program in radiology education. In this paper, we propose a novel hybrid prediction algorithm called content-boosted collaborative filtering (CBCF) to...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-014-9678-z

    authors: Lin H,Yang X,Wang W

    更新日期:2014-08-01 00:00:00

  • DICOM versus HL7 for modality interfacing.

    abstract::Digital modalities such as CT, MRI, Ultrasound and Computerized Radiography systems, generating softcopy images to be used by a Picture Archiving and Communication System (PACS), need to identify the images properly in order to retrieve and manage them. In many cases, a technologist re-enters patient demographic and s...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/BF03168256

    authors: Oosterwijk H

    更新日期:1998-08-01 00:00:00

  • Efficacy of a checklist-style structured radiology reporting template in reducing resident misses on cervical spine computed tomography examinations.

    abstract::The increasing use of medical checklists to promote patient safety raises the question of their utility in diagnostic radiology. This study evaluates the efficacy of a checklist-style reporting template in reducing resident misses on cervical spine CT examinations. A checklist-style reporting template for cervical spi...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-014-9703-2

    authors: Lin E,Powell DK,Kagetsu NJ

    更新日期:2014-10-01 00:00:00

  • Joint segmentation and groupwise registration of cardiac perfusion images using temporal information.

    abstract::We propose a joint segmentation and groupwise registration method for dynamic cardiac perfusion images that uses temporal information. The nature of perfusion images makes groupwise registration especially attractive as the temporal information from the entire image sequence can be used. Registration aims to maximize ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9497-z

    authors: Mahapatra D

    更新日期:2013-04-01 00:00:00

  • Toward Data-Driven Radiology Education-Early Experience Building Multi-Institutional Academic Trainee Interpretation Log Database (MATILDA).

    abstract::The residency review committee of the Accreditation Council of Graduate Medical Education (ACGME) collects data on resident exam volume and sets minimum requirements. However, this data is not made readily available, and the ACGME does not share their tools or methodology. It is therefore difficult to assess the integ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s10278-016-9872-2

    authors: Chen PH,Loehfelm TW,Kamer AP,Lemmon AB,Cook TS,Kohli MD

    更新日期:2016-12-01 00:00:00

  • Information retrieval for teaching files: a preliminary study.

    abstract::A computer algorithm for information retrieval from an electronic teaching file has been developed. This index enables the user to retrieve cases from a teaching file, based on the input of a combination of features. The algorithm is based on nearest neighbor analysis, and is programmed in the "C" language. A teaching...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167602

    authors: Bramble JM,Insana MF,Dwyer SJ 3rd

    更新日期:1990-08-01 00:00:00