Assessing the accuracy factors in the determination of postoperative acetabular cup orientation using hybrid 2D-3D registration.

Abstract:

:Single standard anteroposterior radiograph-based methods for measuring cup orientation following total hip arthroplasty (THA) are subject to substantial errors if the individual pelvic orientation with respect to X-ray plate is not taken into consideration. Previously, we proposed to use a hybrid 2D-3D registration scheme to determine the postoperative acetabular cup orientation and developed an object-oriented cross-program called "HipMatch." However, its accuracy and robustness have not been fully investigated. To assess the potential factors that may affect the accuracy and robustness of the hybrid 2D-3D registration scheme in determining the postoperative acetabular cup orientation, a comprehensive validation study using a cadaver pelvis was performed. Nine X-ray radiographs taken from different pelvic positions relative to the X-ray plate and two computed tomography volumes of the pelvis with one acquired before the cup implantation and the other acquired after the cup implantation were used in the validation study. Potential factors that may affect the accuracy and robustness of the hybrid 2D-3D registration scheme were experimentally determined. Our experimental results demonstrate that (1) the plain radiograph-based method is not accurate; (2) the hybrid 2D-3D registration scheme helps to improve the estimation accuracy; (3) the hybrid 2D-3D registration scheme can robustly and accurately estimate the cup orientation even when a big portion of the radiograph is occluded; and (4) image resolution has minor effect on the estimation accuracy. The hybrid 2D-3D registration scheme is an accurate and robust method to measure exact cup orientation in THA. It holds the promise to be a valuable tool for clinical routine usage for providing evidence-based information.

journal_name

J Digit Imaging

authors

Zheng G

doi

10.1007/s10278-009-9226-4

subject

Has Abstract

pub_date

2010-12-01 00:00:00

pages

769-79

issue

6

eissn

0897-1889

issn

1618-727X

journal_volume

23

pub_type

杂志文章
  • Clinical evaluation of irreversible data compression for computed radiography of the chest.

    abstract::Efficient data compression is essential for practical daily operation of computed radiography (CR) systems. In this study the clinical applicability of type III irreversible high data compression using an FCR 9501 chest unit (Fuji Photo Film, Tokyo, Japan) was evaluated. Sixty-eight normal and 93 various abnormal case...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03178080

    authors: Egashira K,Nakata H,Watanabe H,Uchida K,Nakamura K,Ishino Y,Horino K,Yoshikawa R

    更新日期:1998-11-01 00:00:00

  • Classification of CT Scan Images of Lungs Using Deep Convolutional Neural Network with External Shape-Based Features.

    abstract::In this paper, a simplified yet efficient architecture of a deep convolutional neural network is presented for lung image classification. The images used for classification are computed tomography (CT) scan images obtained from two scientifically used databases available publicly. Six external shape-based features, vi...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00245-9

    authors: Srivastava V,Purwar RK

    更新日期:2020-02-01 00:00:00

  • Programming in the small.

    abstract::Academic medical centers, in general, and radiation oncology research, in particular, rely heavily on custom software tools and applications. The code development is typically the responsibility of a single individual or at most a small team. Often these individuals are not professional programmers but physicists, stu...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-009-9271-z

    authors: Gersten DB,Langer SG

    更新日期:2011-02-01 00:00:00

  • Detection of microcalcifications by means of multiscale methods and statistical techniques.

    abstract::The detection of clustered microcalcifications can help the radiologist to detect early breast cancer. Microcalcifications exhibit some important characteristics, such as small size and high luminosity. Use of a computer-aided diagnosis (CAD) method can prevent them being overlooked. In this report, a multiresolution ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167672

    authors: Mata Campos R,Vidal EM,Nava E,Martínez-Morillo M,Sendra F

    更新日期:2000-05-01 00:00:00

  • An Efficient Pipeline for Abdomen Segmentation in CT Images.

    abstract::Computed tomography (CT) scans usually include some disadvantages due to the nature of the imaging procedure, and these handicaps prevent accurate abdomen segmentation. Discontinuous abdomen edges, bed section of CT, patient information, closeness between the edges of the abdomen and CT, poor contrast, and a narrow hi...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-017-0032-0

    authors: Koyuncu H,Ceylan R,Sivri M,Erdogan H

    更新日期:2018-04-01 00:00:00

  • New picture archiving and communications system plus new facility equals critical path planning challenge.

    abstract::The architectural design and construction of a new imaging department is one of the most complex challenges in healthcare architecture. When a client also plans a simultaneous change in basic operating system technology from film-based to filmless imaging, the challenge for both hospital management and the facility/te...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168779

    authors: Brye PE,Loharikar R,Duda E

    更新日期:1999-05-01 00:00:00

  • A segmentation technique to detect masses in dense breast digitized mammograms.

    abstract::This article describes a segmentation technique that uses the watershed transformation to provide mass detection in dense breast digitized images. The technique consists of four steps: preprocessing, which isolates the breast from the image background; histogram equalization to enhance the contrast; watershed transfor...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-002-5071-4

    authors: Santos VT,Schiabel H,Góes CE,Benatti RH

    更新日期:2002-01-01 00:00:00

  • Joint segmentation and groupwise registration of cardiac perfusion images using temporal information.

    abstract::We propose a joint segmentation and groupwise registration method for dynamic cardiac perfusion images that uses temporal information. The nature of perfusion images makes groupwise registration especially attractive as the temporal information from the entire image sequence can be used. Registration aims to maximize ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9497-z

    authors: Mahapatra D

    更新日期:2013-04-01 00:00:00

  • Ruler Based Automatic C-Arm Image Stitching Without Overlapping Constraint.

    abstract::In this paper, we propose a new method for stitching multiple fluoroscopic images taken by a C-arm instrument. We employ an X-ray radiolucent ruler with numbered graduations while acquiring the images, and the image stitching is based on detecting and matching ruler parts in the images to the corresponding parts of a ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-014-9763-3

    authors: Chen C,Kojcev R,Haschtmann D,Fekete T,Nolte L,Zheng G

    更新日期:2015-08-01 00:00:00

  • Enhancement of storage phosphor plate images: a C-language program.

    abstract::A C-language software program has been developed for emulating the image enhancement processing of a storage phosphor plate system. This software has been implemented on a VAX 3400 computer. There are 2,100 lines of C-language code in the program. There are seven parameters used to specify the degree of enhancement. T...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167825

    authors: Templeton AW,Wetzel LH,Cook LT,Harrison LA,Eckard DA,Anderson WH,Hensley KS

    更新日期:1992-02-01 00:00:00

  • App Review Series: CTisus iPearls.

    abstract::Thousands of "pearls" or facts related to radiology or imaging are accessible through a categorically organized user interface. Pearls are divided up into anatomical regions, as well as non-organ-specific categories. Information is easily accessible with an ad-free interface matched with full offline capability. User ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-018-0103-x

    authors: Buro J

    更新日期:2018-12-01 00:00:00

  • NIRViz: 3D visualization software for multimodality optical imaging using visualization toolkit (VTK) and insight segmentation toolkit (ITK).

    abstract::Optical imaging using near-infrared light is used for noninvasive probing of tissues to recover vascular and molecular status of healthy and diseased tissues using hemoglobin contrast arising due to absorption of light. While multimodality optical techniques exist, visualization techniques in this area are limited. Ad...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9362-5

    authors: Taka SJ,Srinivasan S

    更新日期:2011-12-01 00:00:00

  • A perceptual evaluation of JPEG 2000 image compression for digital mammography: contrast-detail characteristics.

    abstract::In this investigation the effect of JPEG 2000 compression on the contrast-detail (CD) characteristics of digital mammography images was studied using an alternative forced choice (AFC) technique. Images of a contrast-detail phantom, acquired using a clinical full-field digital mammography system, were compressed using...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-003-1728-x

    authors: Suryanarayanan S,Karellas A,Vedantham S,Waldrop SM,D'Orsi CJ

    更新日期:2004-03-01 00:00:00

  • Medical applications of digital image morphing.

    abstract::The authors present a unique medical technical application for illustrating the success and/or failure of the physiological healing process as a dynamically morphed video. Two examples used in this report include the healing of a severely fractured humerus from an explosion in Iraq and the other of dramatic tissue des...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-1050-5

    authors: Penska K,Folio L,Bunger R

    更新日期:2007-09-01 00:00:00

  • Classification of breast masses using selected shape, edge-sharpness, and texture features with linear and kernel-based classifiers.

    abstract::Breast masses due to benign disease and malignant tumors related to breast cancer differ in terms of shape, edge-sharpness, and texture characteristics. In this study, we evaluate a set of 22 features including 5 shape factors, 3 edge-sharpness measures, and 14 texture features computed from 111 regions in mammograms,...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-007-9102-z

    authors: Mu T,Nandi AK,Rangayyan RM

    更新日期:2008-06-01 00:00:00

  • Improvement in Detection of Wrong-Patient Errors When Radiologists Include Patient Photographs in Their Interpretation of Portable Chest Radiographs.

    abstract::This study was conducted to determine whether facial photographs obtained simultaneously with radiographs improve radiologists' detection rate of wrong-patient errors, when they are explicitly asked to include the photographs in their evaluation. Radiograph-photograph combinations were obtained from 28 patients at the...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-015-9808-2

    authors: Tridandapani S,Olsen K,Bhatti P

    更新日期:2015-12-01 00:00:00

  • An assessment of the iPad 2 as a CT teleradiology tool using brain CT with subtle intracranial hemorrhage under conventional illumination.

    abstract::We examined the potential of the iPad 2 as a teleradiologic tool for evaluating brain computed tomography (CT) with subtle hemorrhage in the conventional lighting conditions which are common situations in the remote CT reading. The comparison of the clinician's performance was undertaken through detecting hemorrhage b...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9580-0

    authors: Park JB,Choi HJ,Lee JH,Kang BS

    更新日期:2013-08-01 00:00:00

  • Displaying radiologic images on personal computers: practical applications and uses.

    abstract::This is the fifth and final article in our series for radiologists and imaging scientists on displaying, manipulating, and analyzing radiologic images on personal computers (PCs). There are many methods of transferring radiologic images into a PC, including transfer over a network, transfer from an imaging modality st...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168502

    authors: Gillespy T 3rd,Richardson ML,Rowberg AH

    更新日期:1994-08-01 00:00:00

  • A study for watermark methods appropriate to medical images.

    abstract::The network system, including the picture archiving and communication system (PACS), is essential in hospital and medical imaging fields these days. Many medical images are accessed and processed on the web, as well as in PACS. Therefore, any possible accidents caused by the illegal modification of medical images must...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03190332

    authors: Cho Y,Ahn B,Kim JS,Kim IY,Kim SI

    更新日期:2001-06-01 00:00:00

  • Precise measurement of vertebral bone density using computed tomography without the use of an external reference phantom.

    abstract::Bone density measurement by quantitative computed tomography (QCT) commonly uses an external reference phantom to decrease scan-to-scan and scanner-to-scanner variability. However, the peripheral location of these phantoms and other phantom variables is also responsible for a measurable degradation in accuracy and pre...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168013

    authors: Boden SD,Goodenough DJ,Stockham CD,Jacobs E,Dina T,Allman RM

    更新日期:1989-02-01 00:00:00

  • Integrating multiple clinical information systems using the Java Message Service framework.

    abstract::This article describes an application for capturing, delivering, and tracking urgent radiology exam results. Urgent exam findings are entered using a Web form embedded within the Picture archiving and communication system (PACS) display station. The findings are then accessible via soft copy using the PACS display sta...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-003-1717-0

    authors: Tellis WM,Andriole KP

    更新日期:2004-06-01 00:00:00

  • The effect of slice thickness on the assessment of bone defect volumes by the Cavalieri principle using cone beam computed tomography.

    abstract::The purpose of this study was to investigate the possible effects of section thickness on volume estimations obtained by cone beam computed tomography. Intraosseal cavities representing bone defects on vestibular sides of the two dry sheep mandibles were scanned by a cone beam computed tomography system. Consecutive s...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9480-8

    authors: Sezgin OS,Kayıpmaz S,Sahin B

    更新日期:2013-02-01 00:00:00

  • Effect of viewing angle on luminance and contrast for a five-million-pixel monochrome display and a nine-million-pixel color liquid crystal display.

    abstract::Digital imaging systems used in radiology rely on electronic display devices to present images to human observers. Active-matrix liquid crystal displays (AMLCDs) continue to improve and are beginning to be considered for diagnostic image display. In spite of recent progress, AMLCDs are characterized by a change in lum...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-004-1021-7

    authors: Fifadara DH,Averbukh A,Channin DS,Badano A

    更新日期:2004-12-01 00:00:00

  • A Novel Texture-Quantization-Based Reversible Multiple Watermarking Scheme Applied to Health Information System.

    abstract::The recent innovations in information and communication technologies have appreciably changed the panorama of health information system (HIS). These advances provide new means to process, handle, and share medical images and also augment the medical image security issues in terms of confidentiality, reliability, and i...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-017-0024-0

    authors: Turuk M,Dhande A

    更新日期:2018-04-01 00:00:00

  • Stereotactic neurosurgery planning on a personal-computer-based work station.

    abstract::Stereotactic surgery requires knowledge of cerebral structures derived from more than one image source. We have developed a PC-AT-based workstation that accepts patient images, made with the stereotactic frame in place, from CT, MRI, and DSA modalities. Reference markers on the frame are identified in the images to es...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168023

    authors: Peters TM,Clark JA,Pike GB,Henri C,Collins L,Leksell D,Jeppsson O

    更新日期:1989-05-01 00:00:00

  • Environmental designs for reading from imaging work stations: ergonomic and architectural features.

    abstract::Despite the rapid progress made in the electronic design of imaging work stations for medicine, much less effort has gone into the design of environments in which such systems will be used. Based on studies of radiologist film reading sessions, considerable time will be spent working at such viewing systems. If the ro...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168035

    authors: Horii SC,Horii HN,Mun SK,Benson HR,Zeman RK

    更新日期:1989-08-01 00:00:00

  • Computed radiography: user-programmable features and capabilities.

    abstract::Digital or computed radiography (CR) using photostimulable storage phosphor plate technology is becoming increasingly popular in certain clinical applications, such as bedside radiography, where it possesses clear advantages over conventional screen-film imaging. The majority of CR systems in clinical use have been ma...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168504

    authors: Gingold EL,Tucker DM,Barnes GT

    更新日期:1994-08-01 00:00:00

  • Prostate tissue texture feature extraction for suspicious regions identification on TRUS images.

    abstract::In this work, two different approaches are proposed for region of interest (ROI) segmentation using transrectal ultrasound (TRUS) images. The two methods aim to extract informative features that are able to characterize suspicious regions in the TRUS images. Both proposed methods are based on multi-resolution analysis...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-008-9124-1

    authors: Mohamed SS,Li J,Salama MM,Freeman G

    更新日期:2009-10-01 00:00:00

  • The normal mode analysis shape detection method for automated shape determination of lung nodules.

    abstract::Surface morphology and shape in general are important predictors for the behavior of solid-type lung nodules detected on CT. More broadly, shape analysis is useful in many areas of computer-aided diagnosis and essentially all scientific and engineering disciplines. Automated methods for shape detection have all previo...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-014-9732-x

    authors: Stember JN

    更新日期:2015-04-01 00:00:00

  • Automated pediatric abdominal effective diameter measurements versus age-predicted body size for normalization of CT dose.

    abstract::There has been increasing interest in adjusting CT radiation dose data for patient body size. A method for automated computation of the abdominal effective diameter of a patient from a CT image has previously only been tested in adult patients. In this work, we tested the method on a set of 128 pediatric patients aged...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9623-6

    authors: Cheng PM,Vachon LA,Duddalwar VA

    更新日期:2013-12-01 00:00:00