Large-Scale Assessment of Scan-Time Variability and Multiple-Procedure Efficiency for Cross-Sectional Neuroradiological Exams in Clinical Practice.

Abstract:

:Scheduling of CT and MR exams requires reasonable estimates for expected scan duration. However, scan-time variability and efficiency gains from combining multiple exams are not quantitatively well characterized. In this work, we developed an informatics approach to quantify typical duration, duration variability, and multiple-procedure efficiency on a large scale, and used the approach to analyze 48,766 CT- and MR-based neuroradiological exams performed over one year. We found MR exam durations demonstrated higher absolute variability, but lower relative variability and lower multiple-procedure efficiency, compared to CT exams (p < 0.001). Our approach enables quantification of real-world operational performance and variability to inform optimal patient scheduling, efficient resource utilization, and sustainable service planning.

journal_name

J Digit Imaging

authors

Zhang R,Narra VR,Kansagra AP

doi

10.1007/s10278-019-00252-w

subject

Has Abstract

pub_date

2020-02-01 00:00:00

pages

143-150

issue

1

eissn

0897-1889

issn

1618-727X

pii

10.1007/s10278-019-00252-w

journal_volume

33

pub_type

杂志文章
  • Can Laws Be a Potential PET Image Texture Analysis Approach for Evaluation of Tumor Heterogeneity and Histopathological Characteristics in NSCLC?

    abstract::We investigated the association between the textural features obtained from 18F-FDG images, metabolic parameters (SUVmax, SUVmean, MTV, TLG), and tumor histopathological characteristics (stage and Ki-67 proliferation index) in non-small cell lung cancer (NSCLC). The FDG-PET images of 67 patients with NSCLC were evalua...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-017-9992-3

    authors: Karacavus S,Yılmaz B,Tasdemir A,Kayaaltı Ö,Kaya E,İçer S,Ayyıldız O

    更新日期:2018-04-01 00:00:00

  • One Night in the ED.

    abstract::Radiology 2.0: One Night in the ED is an app that presents users with scrollable CT images for common scenarios found in any Emergency Department (ED). A great tool for a junior resident before starting call, it allows the user to build confidence by experiencing a simulated environment of viewing all images of a case...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-015-9797-1

    authors: Drexler IR

    更新日期:2015-08-01 00:00:00

  • Elastic registration of x-ray mammograms and three-dimensional magnetic resonance imaging data.

    abstract::Major problems in treating breast cancer are the early detection of tumors and accurate biopsy of small volumes of breast (mamma) tissue. This report presents an elastic registration algorithm of two x-ray mammograms and a corresponding magnetic resonance imaging (MRI) volume. To cope with the soft tissue deformation ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03190295

    authors: Ruiter NV,Müller TO,Stotzka R,Kaiser WA

    更新日期:2001-06-01 00:00:00

  • Medical image file formats.

    abstract::Image file format is often a confusing aspect for someone wishing to process medical images. This article presents a demystifying overview of the major file formats currently used in medical imaging: Analyze, Neuroimaging Informatics Technology Initiative (Nifti), Minc, and Digital Imaging and Communications in Medici...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-013-9657-9

    authors: Larobina M,Murino L

    更新日期:2014-04-01 00:00:00

  • An Audio/Video Reporting Workflow to Supplement Standardized Radiology Reports.

    abstract::Radiology studies are inherently visual and the information contained within is best conveyed by visual methodology. Advanced reporting software allows the incorporation of annotated key images into text reports, but such features may be less effective compared with in-person consultations. The use of web technology a...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-015-9821-5

    authors: Balkman JD,Siegel AH

    更新日期:2016-04-01 00:00:00

  • Environmental designs for reading from imaging work stations: ergonomic and architectural features.

    abstract::Despite the rapid progress made in the electronic design of imaging work stations for medicine, much less effort has gone into the design of environments in which such systems will be used. Based on studies of radiologist film reading sessions, considerable time will be spent working at such viewing systems. If the ro...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168035

    authors: Horii SC,Horii HN,Mun SK,Benson HR,Zeman RK

    更新日期:1989-08-01 00:00:00

  • Estimates of Patient Radiation Doses in Digital Radiography Using DICOM Information at a Large Teaching Hospital in Oman.

    abstract::In this study, we sought to estimate the patient radiation doses in the digital radiography X-ray examinations conducted in a large hospital. The patient exposure factors and kerma-area product (PKA) were retrospectively recorded via the Digital Imaging and Communications in Medicine (DICOM) header for 547 patients. T...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00199-y

    authors: Suliman II

    更新日期:2020-02-01 00:00:00

  • The Effect of Registration on Voxel-Wise Tofts Model Parameters and Uncertainties from DCE-MRI of Early-Stage Breast Cancer Patients Using 3DSlicer.

    abstract::We quantitatively investigate the influence of image registration, using open-source software (3DSlicer), on kinetic analysis (Tofts model) of dynamic contrast enhanced MRI of early-stage breast cancer patients. We also show that registration computation time can be reduced by reducing the percent sampling (PS) of vox...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-020-00374-6

    authors: Mouawad M,Biernaski H,Brackstone M,Lock M,Kornecki A,Shmuilovich O,Ben-Nachum I,Prato FS,Thompson RT,Gaede S,Gelman N

    更新日期:2020-10-01 00:00:00

  • A method for computing general sacroiliac screw corridors based on CT scans of the pelvis.

    abstract::Sacroiliac (SI) joint dislocations and sacral fractures of the pelvis can be stabilized by SI screws; however, screw insertion into a sacral isthmus region is risky for the adjacent neurovascular structures. Therefore, shape analyses of general SI screw corridors or safety zones are of great surgical interest; however...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-010-9327-0

    authors: Noser H,Radetzki F,Stock K,Mendel T

    更新日期:2011-08-01 00:00:00

  • Segmentation by evolution for visualization of the lower extremity of the Visible Man.

    abstract::Medical image segmentation is the crucial process for three-dimensional (3D) modeling. Many studies have claimed to suggest more accurate ways of segmentation. However, such research seems to have the drawback that it works against the parsimony principle. These methods have to resegment the regions of interest (ROIs)...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03190342

    authors: Lee JW,Lee J,Kim D,Kim JH,Park KS,Kang HS

    更新日期:2001-06-01 00:00:00

  • Fibrous Dysplasia Characterization Using Lacunarity Analysis.

    abstract::Fibrous dysplasia (FD) is a developmental anomaly in which the normal medullary space of the affected bone is replaced by fibro-osseous tissue. This condition is typically encountered in adolescents and young adults. It affects the maxillofacial region and it can often cause severe deformity and asymmetry. Therefore, ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-015-9815-3

    authors: Cordeiro MS,Backes AR,Júnior AF,Gonçalves EH,de Oliveira JX

    更新日期:2016-02-01 00:00:00

  • Artifacts found during quality assurance testing of computed radiography and digital radiography detectors.

    abstract::A series of artifact images, obtained over 5 years of performance testing, of both computed radiography (CR) and integrated digital radiographic X-ray imaging detectors are presented. The images presented are all either flat field or test object images and show artifacts previously either undescribed in the existing l...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-008-9109-0

    authors: Honey ID,Mackenzie A

    更新日期:2009-08-01 00:00:00

  • A perceptual evaluation of JPEG 2000 image compression for digital mammography: contrast-detail characteristics.

    abstract::In this investigation the effect of JPEG 2000 compression on the contrast-detail (CD) characteristics of digital mammography images was studied using an alternative forced choice (AFC) technique. Images of a contrast-detail phantom, acquired using a clinical full-field digital mammography system, were compressed using...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-003-1728-x

    authors: Suryanarayanan S,Karellas A,Vedantham S,Waldrop SM,D'Orsi CJ

    更新日期:2004-03-01 00:00:00

  • Early lung cancer detection using the self-evaluation scoring questionnaire and chest digital radiography: a 3-year follow-up study in China.

    abstract::The standard definition of high-risk individuals for lung cancer was not uniform and the value of chest digital radiography (DR) in lung cancer screening was still unproven. The aim of this study was to assess whether the original questionnaire named as "Self-evaluation Scoring Questionnaire for High-risk Individuals ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9468-4

    authors: Chen B,Wang Y,Cao H,Liu D,Zhang S,Gao J,Yu J,Huang Y,Li W

    更新日期:2013-02-01 00:00:00

  • Displaying radiologic images on personal computers: practical applications and uses.

    abstract::This is the fifth and final article in our series for radiologists and imaging scientists on displaying, manipulating, and analyzing radiologic images on personal computers (PCs). There are many methods of transferring radiologic images into a PC, including transfer over a network, transfer from an imaging modality st...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168502

    authors: Gillespy T 3rd,Richardson ML,Rowberg AH

    更新日期:1994-08-01 00:00:00

  • White matter fiber tracking computation based on diffusion tensor imaging for clinical applications.

    abstract::Fiber tracking allows the in vivo reconstruction of human brain white matter fiber trajectories based on magnetic resonance diffusion tensor imaging (MR-DTI), but its application in the clinical routine is still in its infancy. In this study, we present a new software for fiber tracking, developed on top of a general-...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-0773-7

    authors: Dellani PR,Glaser M,Wille PR,Vucurevic G,Stadie A,Bauermann T,Tropine A,Perneczky A,von Wangenheim A,Stoeter P

    更新日期:2007-03-01 00:00:00

  • Endowing a Content-Based Medical Image Retrieval System with Perceptual Similarity Using Ensemble Strategy.

    abstract::Content-based medical image retrieval (CBMIR) is a powerful resource to improve differential computer-aided diagnosis. The major problem with CBMIR applications is the semantic gap, a situation in which the system does not follow the users' sense of similarity. This gap can be bridged by the adequate modeling of simil...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-015-9809-1

    authors: Bedo MV,Pereira Dos Santos D,Ponciano-Silva M,de Azevedo-Marques PM,Ferreira de Carvalho AP,Traina C Jr

    更新日期:2016-02-01 00:00:00

  • Stereotactic neurosurgery planning on a personal-computer-based work station.

    abstract::Stereotactic surgery requires knowledge of cerebral structures derived from more than one image source. We have developed a PC-AT-based workstation that accepts patient images, made with the stereotactic frame in place, from CT, MRI, and DSA modalities. Reference markers on the frame are identified in the images to es...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168023

    authors: Peters TM,Clark JA,Pike GB,Henri C,Collins L,Leksell D,Jeppsson O

    更新日期:1989-05-01 00:00:00

  • Ruler Based Automatic C-Arm Image Stitching Without Overlapping Constraint.

    abstract::In this paper, we propose a new method for stitching multiple fluoroscopic images taken by a C-arm instrument. We employ an X-ray radiolucent ruler with numbered graduations while acquiring the images, and the image stitching is based on detecting and matching ruler parts in the images to the corresponding parts of a ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-014-9763-3

    authors: Chen C,Kojcev R,Haschtmann D,Fekete T,Nolte L,Zheng G

    更新日期:2015-08-01 00:00:00

  • CT and MR image fusion scheme in nonsubsampled contourlet transform domain.

    abstract::Fusion of CT and MR images allows simultaneous visualization of details of bony anatomy provided by CT image and details of soft tissue anatomy provided by MR image. This helps the radiologist for the precise diagnosis of disease and for more effective interventional treatment procedures. This paper aims at designing ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9664-x

    authors: Ganasala P,Kumar V

    更新日期:2014-06-01 00:00:00

  • Assessing the accuracy factors in the determination of postoperative acetabular cup orientation using hybrid 2D-3D registration.

    abstract::Single standard anteroposterior radiograph-based methods for measuring cup orientation following total hip arthroplasty (THA) are subject to substantial errors if the individual pelvic orientation with respect to X-ray plate is not taken into consideration. Previously, we proposed to use a hybrid 2D-3D registration sc...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-009-9226-4

    authors: Zheng G

    更新日期:2010-12-01 00:00:00

  • A study for watermark methods appropriate to medical images.

    abstract::The network system, including the picture archiving and communication system (PACS), is essential in hospital and medical imaging fields these days. Many medical images are accessed and processed on the web, as well as in PACS. Therefore, any possible accidents caused by the illegal modification of medical images must...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03190332

    authors: Cho Y,Ahn B,Kim JS,Kim IY,Kim SI

    更新日期:2001-06-01 00:00:00

  • 3D Brain Imaging in Vascular Segmentation of Cerebral Venous Sinuses.

    abstract::The three-dimensional (3D) visualization of dural venous sinuses (DVS) networks is desired by surgical trainers to create a clear mental picture of the neuroanatomical orientation of the complex cerebral anatomy. Our purpose is to document those identified during routine 3D venography created through 3D models using t...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0125-4

    authors: Karakas AB,Govsa F,Ozer MA,Eraslan C

    更新日期:2019-04-01 00:00:00

  • A study of radiologists viewing multiple computed tomography examinations using an eyetracking device.

    abstract::Understanding the scan patterns radiologists use to view medical images is critical to the design of image viewing devices. In this study, an eyetracker, a device for recording eye and head movement, was used to determine the scan patterns during the interpretation of single and multiple computed tomographic (CT) exam...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168120

    authors: Beard DV,Johnston RE,Toki O,Wilcox C

    更新日期:1990-11-01 00:00:00

  • Improvement in Detection of Wrong-Patient Errors When Radiologists Include Patient Photographs in Their Interpretation of Portable Chest Radiographs.

    abstract::This study was conducted to determine whether facial photographs obtained simultaneously with radiographs improve radiologists' detection rate of wrong-patient errors, when they are explicitly asked to include the photographs in their evaluation. Radiograph-photograph combinations were obtained from 28 patients at the...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-015-9808-2

    authors: Tridandapani S,Olsen K,Bhatti P

    更新日期:2015-12-01 00:00:00

  • An effective approach of lesion segmentation within the breast ultrasound image based on the cellular automata principle.

    abstract::In this paper, a novel lesion segmentation within breast ultrasound (BUS) image based on the cellular automata principle is proposed. Its energy transition function is formulated based on global image information difference and local image information difference using different energy transfer strategies. First, an en...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9450-6

    authors: Liu Y,Cheng HD,Huang J,Zhang Y,Tang X

    更新日期:2012-10-01 00:00:00

  • Computer-aided diagnosis for detection of lacunar infarcts on MR images: ROC analysis of radiologists' performance.

    abstract::The purpose of this study was to retrospectively evaluate radiologist performance in detection of lacunar infarcts on T1- and T2-weighted images, without and with the use of a computer-aided diagnosis (CAD) scheme. Thirty T1-weighted and 30 T2-weighted MR images obtained from 30 patients were used for assessing observ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9444-4

    authors: Uchiyama Y,Asano T,Kato H,Hara T,Kanematsu M,Hoshi H,Iwama T,Fujita H

    更新日期:2012-08-01 00:00:00

  • A Narrative Review on Clinical Applications of fNIRS.

    abstract::Functional near-infrared spectroscopy (fNIRS) is a relatively new imaging modality in the functional neuroimaging research arena. The fNIRS modality non-invasively investigates the change of blood oxygenation level in the human brain utilizing the transillumination technique. In the last two decades, the interest in t...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-020-00387-1

    authors: Rahman MA,Siddik AB,Ghosh TK,Khanam F,Ahmad M

    更新日期:2020-10-01 00:00:00

  • Should radiology IT be owned by the chief information officer?

    abstract::Considerable debate within the medical community has focused on the optimal location of information technology (IT) support groups on the organizational chart. The challenge has been to marry local accountability and physician acceptance of IT with the benefits gained by the economies of scale achieved by centralized ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-009-9196-6

    authors: Channin DS,Bowers G,Nagy P

    更新日期:2009-06-01 00:00:00

  • Three monochrome displays from a single, true color video display controller.

    abstract::Some nuclear medicine computer displays, as well as many image processing workstations are "true color" machines characterized by independent memory and grey scale mapping for each of the red, green and blue color channels. Other color image display systems produce a color image from a single grey scale map composed o...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03173872

    authors: Raff U,Spitzer VM

    更新日期:1991-02-01 00:00:00