A study of radiologists viewing multiple computed tomography examinations using an eyetracking device.

Abstract:

:Understanding the scan patterns radiologists use to view medical images is critical to the design of image viewing devices. In this study, an eyetracker, a device for recording eye and head movement, was used to determine the scan patterns during the interpretation of single and multiple computed tomographic (CT) examinations presented on a four-over-four viewbox. CT examinations were used because they represent complex viewing situations. In two separate studies, radiologists viewed patient folders containing single or multiple CT chest examinations and dictated a report. Eye movement was recorded with an eyetracker and video camera. After mounting the films in order, radiologists generally started with a sequential scan through the entire examination, followed by careful viewing of two to four clusters of three to six images, followed by dictation. These results indicate that a well designed radiology workstation should provide an image index, sufficient display area to simultaneously view 10 or more images, random and sequential movement through the examination, image comparison, and image marking.

journal_name

J Digit Imaging

authors

Beard DV,Johnston RE,Toki O,Wilcox C

doi

10.1007/BF03168120

subject

Has Abstract

pub_date

1990-11-01 00:00:00

pages

230-7

issue

4

eissn

0897-1889

issn

1618-727X

journal_volume

3

pub_type

杂志文章
  • Development of a research dedicated archival system (TARAS) in a university hospital.

    abstract::Recent healthcare policies have influenced the manner in which patient data is handled in research projects, and the regulations concerning protected health information have become significantly tighter. Thus, new procedures are needed to facilitate research while protecting the confidentiality of patient data and ens...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-010-9350-1

    authors: Rajala T,Savio S,Penttinen J,Dastidar P,Kähönen M,Eskola H,Miettunen R,Turjanmaa V,Järvenpää R

    更新日期:2011-10-01 00:00:00

  • A heuristic approach to automated nipple detection in digital mammograms.

    abstract::In this paper, a heuristic approach to automated nipple detection in digital mammograms is presented. A multithresholding algorithm is first applied to segment the mammogram and separate the breast region from the background region. Next, the problem is considered separately for craniocaudal (CC) and mediolateral-obli...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9575-x

    authors: Jas M,Mukhopadhyay S,Chakraborty J,Sadhu A,Khandelwal N

    更新日期:2013-10-01 00:00:00

  • A segmentation technique to detect masses in dense breast digitized mammograms.

    abstract::This article describes a segmentation technique that uses the watershed transformation to provide mass detection in dense breast digitized images. The technique consists of four steps: preprocessing, which isolates the breast from the image background; histogram equalization to enhance the contrast; watershed transfor...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-002-5071-4

    authors: Santos VT,Schiabel H,Góes CE,Benatti RH

    更新日期:2002-01-01 00:00:00

  • One Night in the ED.

    abstract::Radiology 2.0: One Night in the ED is an app that presents users with scrollable CT images for common scenarios found in any Emergency Department (ED). A great tool for a junior resident before starting call, it allows the user to build confidence by experiencing a simulated environment of viewing all images of a case...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-015-9797-1

    authors: Drexler IR

    更新日期:2015-08-01 00:00:00

  • Full-Dose PET Image Estimation from Low-Dose PET Image Using Deep Learning: a Pilot Study.

    abstract::Positron emission tomography (PET) imaging is an effective tool used in determining disease stage and lesion malignancy; however, radiation exposure to patients and technicians during PET scans continues to draw concern. One way to minimize radiation exposure is to reduce the dose of radioactive tracer administered in...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0150-3

    authors: Kaplan S,Zhu YM

    更新日期:2019-10-01 00:00:00

  • White matter fiber tracking computation based on diffusion tensor imaging for clinical applications.

    abstract::Fiber tracking allows the in vivo reconstruction of human brain white matter fiber trajectories based on magnetic resonance diffusion tensor imaging (MR-DTI), but its application in the clinical routine is still in its infancy. In this study, we present a new software for fiber tracking, developed on top of a general-...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-0773-7

    authors: Dellani PR,Glaser M,Wille PR,Vucurevic G,Stadie A,Bauermann T,Tropine A,Perneczky A,von Wangenheim A,Stoeter P

    更新日期:2007-03-01 00:00:00

  • Touch Surgery: a Twenty-First Century Platform for Surgical Training.

    abstract::This manuscript reviews Touch Surgery, a novel online platform geared towards innovating professional training for surgical procedures. In other industries, such as aviation, simulation has already been shown to reduce costs and improve outcomes in crisis (JETS 3(4):348-352, 2010). Studies involving simulation-based l...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-018-0102-y

    authors: Mandler AG

    更新日期:2018-10-01 00:00:00

  • Assessment of coronary artery calcium using dual-energy subtraction digital radiography.

    abstract::Cardiovascular disease is the leading cause of global mortality, yet its early detection remains a vexing problem of modern medicine. Although the computed tomography (CT) calcium score predicts cardiovascular risk, relatively high cost ($250-400) and radiation dose (1-3 mSv) limit its universal utility as a screening...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9385-y

    authors: Mafi JN,Fei B,Roble S,Dota A,Katrapati P,Bezerra HG,Wang H,Wang W,Ciancibello L,Costa M,Simon DI,Orringer CE,Gilkeson RC

    更新日期:2012-02-01 00:00:00

  • Comparative performance analysis of state-of-the-art classification algorithms applied to lung tissue categorization.

    abstract::In this paper, we compare five common classifier families in their ability to categorize six lung tissue patterns in high-resolution computed tomography (HRCT) images of patients affected with interstitial lung diseases (ILD) and with healthy tissue. The evaluated classifiers are naive Bayes, k-nearest neighbor, J48 d...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-008-9158-4

    authors: Depeursinge A,Iavindrasana J,Hidki A,Cohen G,Geissbuhler A,Platon A,Poletti PA,Müller H

    更新日期:2010-02-01 00:00:00

  • PDA-phone-based instant transmission of radiological images over a CDMA network by combining the PACS screen with a Bluetooth-interfaced local wireless link.

    abstract::Remote teleconsultation by specialists is important for timely, correct, and specialized emergency surgical and medical decision making. In this paper, we designed a new personal digital assistant (PDA)-phone-based emergency teleradiology system by combining cellular communication with Bluetooth-interfaced local wirel...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-007-9002-2

    authors: Kim DK,Yoo SK,Park JJ,Kim SH

    更新日期:2007-06-01 00:00:00

  • Incorporating out-patient data from CD-R into the local PACS using DICOM worklist features.

    abstract::With the introduction of digital imaging in radiology, CD-Rs are increasingly used to distribute patient materials. This study investigates the application of a new software package and work protocol to integrate out-hospital data into the local PACS (picture archive and communication system) archive, which is hampere...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-005-5158-9

    authors: van Ooijen PM,Guignot J,Mevel G,Oudkerk M

    更新日期:2005-09-01 00:00:00

  • Cell Nuclei Segmentation in Cytological Images Using Convolutional Neural Network and Seeded Watershed Algorithm.

    abstract::Morphometric analysis of nuclei is crucial in cytological examinations. Unfortunately, nuclei segmentation presents many challenges because they usually create complex clusters in cytological samples. To deal with this problem, we are proposing an approach, which combines convolutional neural network and watershed tra...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00200-8

    authors: Kowal M,Żejmo M,Skobel M,Korbicz J,Monczak R

    更新日期:2020-02-01 00:00:00

  • Patient-specific three-dimensional composite bone models for teaching and operation planning.

    abstract:BACKGROUND:Orthopedic trauma care relies on two-dimensional radiograms both before and during the operation. Understanding the three-dimensional nature of complex fractures on plain radiograms is challenging. Modern fluoroscopes can acquire three-dimensional volume datasets even during an operation, but the device limi...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-007-9078-8

    authors: Matthews F,Messmer P,Raikov V,Wanner GA,Jacob AL,Regazzoni P,Egli A

    更新日期:2009-10-01 00:00:00

  • INDIAM--an e-learning system for the interpretation of mammograms.

    abstract::We propose the design of a teaching system named Interpretation and Diagnosis of Mammograms (INDIAM) for training students in the interpretation of mammograms and diagnosis of breast cancer. The proposed system integrates an illustrated tutorial on radiology of the breast, that is, mammography, which uses education te...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-008-9111-6

    authors: Guliato D,Bôaventura RS,Maia MA,Rangayyan RM,Simedo MS,Macedo TA

    更新日期:2009-08-01 00:00:00

  • Increasing the number of gray shades in medical display systems--how much is enough?

    abstract::Medical images produced by x-ray detectors, computed tomography (CT) scanners, and other modalities typically contain between 12-16 bits/pixel, which corresponds to 4,096-65,536 shades of gray. On the other hand, we see that these images are visualized by means of medical displays that have much lower available number...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-1052-3

    authors: Kimpe T,Tuytschaever T

    更新日期:2007-12-01 00:00:00

  • Computed radiography in pediatrics.

    abstract::Computed radiography (CR) has various advantages such as dynamic range. Diagnostic accuracy with CR using reduced radiation dose is considered comparable with that of conventional film-screen radiography in diagnosing apparent chest abnormalities. In addition to reducing the radiation dose, delineation of the various ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168076

    authors: Aoki K

    更新日期:1995-02-01 00:00:00

  • Freehand liver volumetry by using an electromagnetic pen tablet: accuracy, precision, and rapidity.

    abstract::The purpose of this study is to assess the accuracy, precision, and rapidity of liver volumes calculated by using a freehand electromagnetic pen tablet contourtracing method as compared with the volumes calculated by using the standard optical mouse contourtracing method. The imaging data used as input for accuracy an...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-010-9291-8

    authors: Perandini S,Faccioli N,Inama M,Pozzi Mucelli R

    更新日期:2011-04-01 00:00:00

  • Integrating an Ontology of Radiology Differential Diagnosis with ICD-10-CM, RadLex, and SNOMED CT.

    abstract::An ontology offers a human-readable and machine-computable representation of the concepts in a domain and the relationships among them. Mappings between ontologies enable the reuse and interoperability of biomedical knowledge. We sought to map concepts of the Radiology Gamuts Ontology (RGO), an ontology that links dis...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00186-3

    authors: Filice RW,Kahn CE Jr

    更新日期:2019-04-01 00:00:00

  • Toward Data-Driven Radiology Education-Early Experience Building Multi-Institutional Academic Trainee Interpretation Log Database (MATILDA).

    abstract::The residency review committee of the Accreditation Council of Graduate Medical Education (ACGME) collects data on resident exam volume and sets minimum requirements. However, this data is not made readily available, and the ACGME does not share their tools or methodology. It is therefore difficult to assess the integ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s10278-016-9872-2

    authors: Chen PH,Loehfelm TW,Kamer AP,Lemmon AB,Cook TS,Kohli MD

    更新日期:2016-12-01 00:00:00

  • SCAR R&D Symposium 2003: comparing the efficacy of 5-MP CRT versus 3-MP LCD in the evaluation of interstitial lung disease.

    abstract::The efficacy of two medical-grade, self-calibrating, gray scale displays were compared with regard to impact on sensitivity and specificity for the detection of interstitial lung disease (ILD) on computed radiographs (CR). The displays were a 5-megapixel (MP) cathode ray tube (CRT) device and a 3-MP liquid crystal dis...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-004-1013-7

    authors: Langer S,Bartholmai B,Fetterly K,Harmsen S,Ryan W,Erickson B,Andriole K,Carrino J

    更新日期:2004-09-01 00:00:00

  • A study for watermark methods appropriate to medical images.

    abstract::The network system, including the picture archiving and communication system (PACS), is essential in hospital and medical imaging fields these days. Many medical images are accessed and processed on the web, as well as in PACS. Therefore, any possible accidents caused by the illegal modification of medical images must...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03190332

    authors: Cho Y,Ahn B,Kim JS,Kim IY,Kim SI

    更新日期:2001-06-01 00:00:00

  • Analysis of the X-ray work flow in two diagnostic imaging departments with and without a RIS/PACS system.

    abstract::A traditional radiological workflow is compared with one based on radiology information system/picture archiving and communication system (RIS/PACS). X-ray workflow process was considered in both radiology departments. First, the study identified the main phases of the research work as follows: Process Analysis, Data ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-0858-3

    authors: Mariani C,Tronchi A,Oncini L,Pirani O,Murri R

    更新日期:2006-01-01 00:00:00

  • The effects of ambient lighting in chest radiology reading rooms.

    abstract::Under typical dark chest radiography reading room conditions, a radiologist's pupils contract and dilate as their visual focus intermittently shifts between the high luminance monitor and the darker background wall, resulting in increased visual fatigue and degradation of diagnostic performance. A controlled increase ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9459-5

    authors: Pollard BJ,Samei E,Chawla AS,Beam C,Heyneman LE,Koweek LM,Martinez-Jimenez S,Washington L,Hashimoto N,McAdams HP

    更新日期:2012-08-01 00:00:00

  • Prostate tissue texture feature extraction for suspicious regions identification on TRUS images.

    abstract::In this work, two different approaches are proposed for region of interest (ROI) segmentation using transrectal ultrasound (TRUS) images. The two methods aim to extract informative features that are able to characterize suspicious regions in the TRUS images. Both proposed methods are based on multi-resolution analysis...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-008-9124-1

    authors: Mohamed SS,Li J,Salama MM,Freeman G

    更新日期:2009-10-01 00:00:00

  • Elastic registration of x-ray mammograms and three-dimensional magnetic resonance imaging data.

    abstract::Major problems in treating breast cancer are the early detection of tumors and accurate biopsy of small volumes of breast (mamma) tissue. This report presents an elastic registration algorithm of two x-ray mammograms and a corresponding magnetic resonance imaging (MRI) volume. To cope with the soft tissue deformation ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03190295

    authors: Ruiter NV,Müller TO,Stotzka R,Kaiser WA

    更新日期:2001-06-01 00:00:00

  • An interactive RADIANCE toolkit for customizable CT dose monitoring and reporting.

    abstract::The need for tools to monitor imaging-related radiation has grown dramatically in recent years. RADIANCE, a freely available open-source dose-monitoring tool, was developed in response to the need for an informatics solution in this realm. A number of open-source as well as commercial solutions have since been develop...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9570-2

    authors: Cook TS,Sundaram A,Boonn WW,Kim W

    更新日期:2013-08-01 00:00:00

  • A Narrative Review on Clinical Applications of fNIRS.

    abstract::Functional near-infrared spectroscopy (fNIRS) is a relatively new imaging modality in the functional neuroimaging research arena. The fNIRS modality non-invasively investigates the change of blood oxygenation level in the human brain utilizing the transillumination technique. In the last two decades, the interest in t...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-020-00387-1

    authors: Rahman MA,Siddik AB,Ghosh TK,Khanam F,Ahmad M

    更新日期:2020-10-01 00:00:00

  • Application of temporal subtraction for detection of interval changes on chest radiographs: improvement of subtraction images using automated initial image matching.

    abstract::The authors developed a temporal subtraction scheme based on a nonlinear geometric warping technique to assist radiologists in the detection of interval changes in chest radiographs obtained on different occasions. The performance of the current temporal subtraction scheme is reasonably good; however, severe misregist...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168846

    authors: Ishida T,Ashizawa K,Engelmann R,Katsuragawa S,MacMahon H,Doi K

    更新日期:1999-05-01 00:00:00

  • DEWEY: the DICOM-enabled workflow engine system.

    abstract::Workflow is a widely used term to describe the sequence of steps to accomplish a task. The use of workflow technology in medicine and medical imaging in particular is limited. In this article, we describe the application of a workflow engine to improve workflow in a radiology department. We implemented a DICOM-enabled...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9661-0

    authors: Erickson BJ,Langer SG,Blezek DJ,Ryan WJ,French TL

    更新日期:2014-06-01 00:00:00

  • Diagnostic accuracy of film-based, TIFF, and wavelet compressed digital temporomandibular joint images.

    abstract::The purpose of this research was to determine if digitization and the application of various compression routines to digital images of temporomandibular joint (TMJ) radiographs would diminish observer accuracy in the detection of specific osseous characteristics associated with TMJ degenerative joint disease (DJD). Ni...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168339

    authors: Trapnell CJ,Scarfe WC,Cook JH,Silvejra AM,Regennitter FJ,Haskell BS

    更新日期:2000-02-01 00:00:00