Abstract:
:The objective of this study was to determine the clinical value of computed tomography (CT) image-based texture analysis in predicting microvascular invasion of primary hepatocellular carcinoma (HCC). CT images of patients with HCC from May 2017 to May 2019 confirmed by surgery and histopathology were retrospectively analyzed. Image features including tumor margin, tumor capsule, peritumoral enhancement, hypoattenuating halo, intratumoral arteries, and tumor-liver differences were assessed. All patients were divided into microvascular invasion (MVI)-negative group (n = 34) and MVI-positive group (n = 68). Preoperative CT images were further imported into MaZda software, where the regions of interest of the lesions were manually delineated. Texture features of lesions based on pre-contrast, arterial, portal, and equilibrium phase CT images were extracted. Thirty optimal texture parameters were selected from each phase by Fisher's coefficient (Fisher), classification error probability combined with average correlation coefficient (POE+ACC), and mutual information (MI). Finally, receiver operating characteristic curve analysis was performed. The results showed that the Edmonson-Steiner grades, tumor size, tumor margin, and intratumoral artery characteristics were significantly different between the two groups (P = 0.012, < 0.001, < 0.001, = 0.003, respectively). There were 58 parameters with significant differences between the MVI-negative and MVI-positive groups (P < 0.001 for all). Among them, 12, 14, 17, and 15 parameters were derived from the pre-contrast phase, arterial phase, portal phase, and equilibrium phase respectively. According to the ROC analysis, optimal texture parameters based on the pre-contrast, arterial, portal, and equilibrium phases were 135dr_GLevNonU (AUC, 0.766; the cutoff value, 1055.00), Vertl_RLNonUni (AUC, 0.764; the cutoff value, 5974.38), 45dgr_GLevNonU (AUC, 0.762; the cutoff value, 924.34), and Vertl_RLNonUni (AUC, 0.754; the cutoff value, 4868.80), respectively. Texture analysis of preoperative CT images may be used as a non-invasive method to predict microvascular invasion in patients with primary hepatocellular carcinomas, and further to guide the treatment and evaluate prognosis. The most valuable parameters were derived from the gray-level run-length matrix.
journal_name
J Digit Imagingjournal_title
Journal of digital imagingauthors
Li Y,Xu X,Weng S,Yan C,Chen J,Ye Rdoi
10.1007/s10278-020-00386-2subject
Has Abstractpub_date
2020-12-01 00:00:00pages
1365-1375issue
6eissn
0897-1889issn
1618-727Xpii
10.1007/s10278-020-00386-2journal_volume
33pub_type
杂志文章abstract::We propose the design of a teaching system named Interpretation and Diagnosis of Mammograms (INDIAM) for training students in the interpretation of mammograms and diagnosis of breast cancer. The proposed system integrates an illustrated tutorial on radiology of the breast, that is, mammography, which uses education te...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-008-9111-6
更新日期:2009-08-01 00:00:00
abstract::Different digital medical images have been printed on paper with a continuous ink jet printer, and the quality has been evaluated. The emphasis has been on digital chest radiographs from a computed radiography system. The ink jet printing technique is described as well as the handling of the image data from image sour...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03167806
更新日期:1992-11-01 00:00:00
abstract::The standard definition of high-risk individuals for lung cancer was not uniform and the value of chest digital radiography (DR) in lung cancer screening was still unproven. The aim of this study was to assess whether the original questionnaire named as "Self-evaluation Scoring Questionnaire for High-risk Individuals ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-012-9468-4
更新日期:2013-02-01 00:00:00
abstract::New consumer technologies and interoperability standards have dated the first standardized curriculum for imaging informatics fellowships suggested by the Society for Computer Applications in Radiology (SCAR) in 2004 (Journal of digital imaging 17(4):244-248, 2004). Last year, analysis from this institution characteri...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-019-00292-2
更新日期:2020-04-01 00:00:00
abstract::Today, many hospitals have a running enterprise picture archiving and communication system (PACS) and their administrators should have the tools to measure the system activity and, in particular, how much it is used. The information would be valuable for decision-makers to address asset management and the development ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-016-9870-4
更新日期:2016-12-01 00:00:00
abstract::Understanding the scan patterns radiologists use to view medical images is critical to the design of image viewing devices. In this study, an eyetracker, a device for recording eye and head movement, was used to determine the scan patterns during the interpretation of single and multiple computed tomographic (CT) exam...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168120
更新日期:1990-11-01 00:00:00
abstract::Perfusion CT of the liver typically involves scanning the liver at least 20 times, resulting in a large radiation dose. We developed and validated a simplified model of tumor blood supply that can be applied to standard triphasic scans and evaluated whether this can be used to distinguish benign and malignant liver le...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-014-9725-9
更新日期:2015-04-01 00:00:00
abstract::This paper details our experience in developing and implementing an automated DICOM Image Router. This workstation serves as a gateway between image acquisition devices and image display and storage devices. Images are checked for demographic input errors and data format inconsistencies between the source and destinat...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168283
更新日期:1998-08-01 00:00:00
abstract::The authors present an adaptation of the macro recording feature on the Siemens Magic View 1000 workstation, which, with the click of one button, launches a macro that performs 3 clinically useful image manipulations. Using a Magic View 1004 Siemens unix workstation, the following Macro sequence was programmed: (1) se...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-002-5078-x
更新日期:2002-01-01 00:00:00
abstract::A traditional radiological workflow is compared with one based on radiology information system/picture archiving and communication system (RIS/PACS). X-ray workflow process was considered in both radiology departments. First, the study identified the main phases of the research work as follows: Process Analysis, Data ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-006-0858-3
更新日期:2006-01-01 00:00:00
abstract::The authors present a unique medical technical application for illustrating the success and/or failure of the physiological healing process as a dynamically morphed video. Two examples used in this report include the healing of a severely fractured humerus from an explosion in Iraq and the other of dramatic tissue des...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-006-1050-5
更新日期:2007-09-01 00:00:00
abstract::Numerous articles have offered instructions for working with advanced radiology images in Microsoft PowerPoint (Redmond, WA); however, no articles have detailed instructions to do the same on alternative presentation software. Apple Macintosh (Cupertino, CA) computers are gaining popularity with many radiologists, due...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-010-9345-y
更新日期:2011-10-01 00:00:00
abstract::In this article, we describe the development and validation of an automatic algorithm to segment brain from extracranial tissues, and to classify intracranial tissues as cerebrospinal fluid (CSF), gray matter (GM), white matter (WM) or pathology. T1 weighted spin echo, dual echo fast spin echo (T2 weighted and proton ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168729
更新日期:1998-05-01 00:00:00
abstract::This paper presents our solution for supporting radiologists' interpretation of digital images by automating image presentation during sequential interpretation steps. We extended current hanging protocols with support for "stages" which reflect the presentation of digital information required to complete a single ste...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-004-1906-5
更新日期:2005-06-01 00:00:00
abstract::To solve the problems of image displays in filmless radiology conferences for the purpose of teaching, we made an experimental design of a conference system with dual 50-in. plasma monitors for displaying larger images and a shared folder containing shortcuts to images for quick display during conferences on the deskt...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-007-9095-7
更新日期:2009-12-01 00:00:00
abstract::We introduce a set of worksheets to facilitate standardized comparisons among scheduling systems, hospital information systems, radiology information systems, and picture archiving and communication systems vendors. For each system category, we provide worksheets to evaluate the features, performance, installation req...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168605
更新日期:1996-08-01 00:00:00
abstract::We aimed to investigate whether an offsite expert could effectively evaluate visually estimated ejection fraction (EF) while watching and guiding the echocardiographic procedure of an onsite novice practitioner using a social network video call. Sixty patients presenting to the intensive care unit and requiring echoca...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-017-9974-5
更新日期:2017-12-01 00:00:00
abstract::Computed tomography (CT) scans usually include some disadvantages due to the nature of the imaging procedure, and these handicaps prevent accurate abdomen segmentation. Discontinuous abdomen edges, bed section of CT, patient information, closeness between the edges of the abdomen and CT, poor contrast, and a narrow hi...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-017-0032-0
更新日期:2018-04-01 00:00:00
abstract::The study investigates the effect of a substantial dose reduction on the variability of lung nodule volume measurements by assessing and comparing nodule volumes using a dedicated semiautomated segmentation software on ultralow-dose computed tomography (ULD-CT) and standard-dose computed tomography (SD-CT) data. In 20...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-008-9157-5
更新日期:2010-02-01 00:00:00
abstract::Fusion of CT and MR images allows simultaneous visualization of details of bony anatomy provided by CT image and details of soft tissue anatomy provided by MR image. This helps the radiologist for the precise diagnosis of disease and for more effective interventional treatment procedures. This paper aims at designing ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-013-9664-x
更新日期:2014-06-01 00:00:00
abstract::Computed radiography of chest with a 4K image array was recently introduced. We performed a multiobserver study to compare the diagnostic accuracy of 2K (standard) and 4K (high quality) chest radiographs displayed on a 5-mega-pixel monitor (2K monitor). One hundred cases of posteroanterior chest radiographs (a total o...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-006-1048-z
更新日期:2007-12-01 00:00:00
abstract::Breast cancer is the most common type of malignancy diagnosed in women. Through early detection and diagnosis, there is a great chance of recovery and thereby reduce the mortality rate. Many preliminary tests like non-invasive radiological diagnosis using ultrasound, mammography, and MRI are widely used for the diagno...
journal_title:Journal of digital imaging
pub_type: 杂志文章,评审
doi:10.1007/s10278-019-00295-z
更新日期:2020-10-01 00:00:00
abstract::Under typical dark chest radiography reading room conditions, a radiologist's pupils contract and dilate as their visual focus intermittently shifts between the high luminance monitor and the darker background wall, resulting in increased visual fatigue and degradation of diagnostic performance. A controlled increase ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-012-9459-5
更新日期:2012-08-01 00:00:00
abstract::A bar-code terminal network under software control of a microcomputer was added to the minicomputer-based radiology information system at the Medical College of Georgia in Augusta. The bar-code network was specifically installed to address the inherent inaccuracies occurring when procedure information was entered at t...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168107
更新日期:1990-02-01 00:00:00
abstract::Despite the rapid progress made in the electronic design of imaging work stations for medicine, much less effort has gone into the design of environments in which such systems will be used. Based on studies of radiologist film reading sessions, considerable time will be spent working at such viewing systems. If the ro...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168035
更新日期:1989-08-01 00:00:00
abstract::In this investigation the effect of JPEG 2000 compression on the contrast-detail (CD) characteristics of digital mammography images was studied using an alternative forced choice (AFC) technique. Images of a contrast-detail phantom, acquired using a clinical full-field digital mammography system, were compressed using...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-003-1728-x
更新日期:2004-03-01 00:00:00
abstract::Rather than perpetuating the struggle, "who controls the PACS, Radiology or Information Technology (IT)," Community Hospital of the Monterey Peninsula (CHOMP) took the approach of incorporating IT support within the Radiology Department. CHOMP faced the challenge of staffing Radiology computer systems and networks by ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-002-5048-3
更新日期:2002-01-01 00:00:00
abstract::The need for tools to monitor imaging-related radiation has grown dramatically in recent years. RADIANCE, a freely available open-source dose-monitoring tool, was developed in response to the need for an informatics solution in this realm. A number of open-source as well as commercial solutions have since been develop...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-013-9570-2
更新日期:2013-08-01 00:00:00
abstract::Image file format is often a confusing aspect for someone wishing to process medical images. This article presents a demystifying overview of the major file formats currently used in medical imaging: Analyze, Neuroimaging Informatics Technology Initiative (Nifti), Minc, and Digital Imaging and Communications in Medici...
journal_title:Journal of digital imaging
pub_type: 杂志文章,评审
doi:10.1007/s10278-013-9657-9
更新日期:2014-04-01 00:00:00
abstract::The recognizability of facial images extracted from publically available medical scans raises patient privacy concerns. This study examined how accurately facial images extracted from computed tomography (CT) scans are objectively matched with corresponding photographs of the scanned individuals. The test subjects wer...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-016-9932-7
更新日期:2017-04-01 00:00:00