Abstract:
:To solve the problems of image displays in filmless radiology conferences for the purpose of teaching, we made an experimental design of a conference system with dual 50-in. plasma monitors for displaying larger images and a shared folder containing shortcuts to images for quick display during conferences on the desktop of each client computer in a picture archival and communication system. The image quality of the monitors was evaluated using the TG18-QC test pattern. The display time of images was measured in 20 cases when the shared folder was used and when it was not. Monitor screen size and image quality, operability, display time of images, and overall impression given by the system were evaluated subjectively by five radiologists. Although the image quality of the monitor was not as high as that of the high-resolution monitors used for diagnostic radiology, its performance was good enough for teaching. The average display time using the shared folder (2.6 +/- 0.39 s) was significantly shorter than without it (16.9 +/- 5.04 s; p = 2.85 x 10(-6)). Despite the need for certain improvements in monitor size and in the operability of the system, the radiologists considered the system suitable for radiology teaching conferences. We believe that this system is useful for institutions that intend to introduce a filmless system for filmless radiology teaching conferences.
journal_name
J Digit Imagingjournal_title
Journal of digital imagingauthors
Abe K,Narata M,Tanaka I,Takahashi M,Igarashi A,Sasaki T,Matsuyama K,Tohi N,Kosuda Sdoi
10.1007/s10278-007-9095-7subject
Has Abstractpub_date
2009-12-01 00:00:00pages
598-604issue
6eissn
0897-1889issn
1618-727Xjournal_volume
22pub_type
杂志文章abstract::The purpose of this study is to assess the accuracy, precision, and rapidity of liver volumes calculated by using a freehand electromagnetic pen tablet contourtracing method as compared with the volumes calculated by using the standard optical mouse contourtracing method. The imaging data used as input for accuracy an...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-010-9291-8
更新日期:2011-04-01 00:00:00
abstract::This article presents a review of image quality assessment methods for monochrome CRTs in the field as opposed to the laboratory. The review includes image quality programs at the University of Washington, the University of Texas at Houston, the University of Michigan, and the University of Arizona. CRT manufacturers ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168851
更新日期:1999-11-01 00:00:00
abstract::Thousands of "pearls" or facts related to radiology or imaging are accessible through a categorically organized user interface. Pearls are divided up into anatomical regions, as well as non-organ-specific categories. Information is easily accessible with an ad-free interface matched with full offline capability. User ...
journal_title:Journal of digital imaging
pub_type: 杂志文章,评审
doi:10.1007/s10278-018-0103-x
更新日期:2018-12-01 00:00:00
abstract::Fusion of CT and MR images allows simultaneous visualization of details of bony anatomy provided by CT image and details of soft tissue anatomy provided by MR image. This helps the radiologist for the precise diagnosis of disease and for more effective interventional treatment procedures. This paper aims at designing ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-013-9664-x
更新日期:2014-06-01 00:00:00
abstract::Increasing radiologic exam volume and complexity necessitates leveraging advanced hardware solutions to optimize workflow efficiency. We evaluated radiologist satisfaction of a programmable 13-button non-conventional mouse compared to a conventional three-button mouse in daily interpretation workflow following a brief...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-018-0094-7
更新日期:2018-12-01 00:00:00
abstract::There has been increasing interest in adjusting CT radiation dose data for patient body size. A method for automated computation of the abdominal effective diameter of a patient from a CT image has previously only been tested in adult patients. In this work, we tested the method on a set of 128 pediatric patients aged...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-013-9623-6
更新日期:2013-12-01 00:00:00
abstract::Positron emission tomography (PET) imaging is an effective tool used in determining disease stage and lesion malignancy; however, radiation exposure to patients and technicians during PET scans continues to draw concern. One way to minimize radiation exposure is to reduce the dose of radioactive tracer administered in...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-018-0150-3
更新日期:2019-10-01 00:00:00
abstract::The interfacing of digital image acquisition modalities to the picture archiving and communication system (PACS) plays a major part in the conversion from a traditional film-based radiology practice to one that relies almost entirely on soft-copy reading. The Baltimore Veterans Affairs Medical Center (VAMC) is one of ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03167632
更新日期:2000-05-01 00:00:00
abstract::Optical imaging using near-infrared light is used for noninvasive probing of tissues to recover vascular and molecular status of healthy and diseased tissues using hemoglobin contrast arising due to absorption of light. While multimodality optical techniques exist, visualization techniques in this area are limited. Ad...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-011-9362-5
更新日期:2011-12-01 00:00:00
abstract::Computed tomography (CT) scans usually include some disadvantages due to the nature of the imaging procedure, and these handicaps prevent accurate abdomen segmentation. Discontinuous abdomen edges, bed section of CT, patient information, closeness between the edges of the abdomen and CT, poor contrast, and a narrow hi...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-017-0032-0
更新日期:2018-04-01 00:00:00
abstract::Emission tomographic image reconstruction is an ill-posed problem due to limited and noisy data and various image-degrading effects affecting the data and leads to noisy reconstructions. Explicit regularization, through iterative reconstruction methods, is considered better to compensate for reconstruction-based noise...
journal_title:Journal of digital imaging
pub_type: 杂志文章,评审
doi:10.1007/s10278-015-9853-x
更新日期:2016-06-01 00:00:00
abstract::The network system, including the picture archiving and communication system (PACS), is essential in hospital and medical imaging fields these days. Many medical images are accessed and processed on the web, as well as in PACS. Therefore, any possible accidents caused by the illegal modification of medical images must...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03190332
更新日期:2001-06-01 00:00:00
abstract::The objective of this study is to retrospectively investigate whether using the newly developed algorithms would improve radiologists' accuracy for discriminating malignant masses from benign ones on ultrasonographic (US) images. Five radiologists blinded to the histological results and clinical history independently ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-009-9245-1
更新日期:2010-10-01 00:00:00
abstract::In this paper, we compare five common classifier families in their ability to categorize six lung tissue patterns in high-resolution computed tomography (HRCT) images of patients affected with interstitial lung diseases (ILD) and with healthy tissue. The evaluated classifiers are naive Bayes, k-nearest neighbor, J48 d...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-008-9158-4
更新日期:2010-02-01 00:00:00
abstract::Workflow is a widely used term to describe the sequence of steps to accomplish a task. The use of workflow technology in medicine and medical imaging in particular is limited. In this article, we describe the application of a workflow engine to improve workflow in a radiology department. We implemented a DICOM-enabled...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-013-9661-0
更新日期:2014-06-01 00:00:00
abstract::While occupational stress and fatigue have been well described throughout medicine, the radiology community is particularly susceptible due to declining reimbursements, heightened demands for service deliverables, and increasing exam volume and complexity. The resulting occupational stress can be variable in nature an...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-012-9540-0
更新日期:2013-02-01 00:00:00
abstract::Digital modalities such as CT, MRI, Ultrasound and Computerized Radiography systems, generating softcopy images to be used by a Picture Archiving and Communication System (PACS), need to identify the images properly in order to retrieve and manage them. In many cases, a technologist re-enters patient demographic and s...
journal_title:Journal of digital imaging
pub_type: 杂志文章,评审
doi:10.1007/BF03168256
更新日期:1998-08-01 00:00:00
abstract::Recent technological innovations have created new opportunities for the increased adoption of virtual reality (VR) and augmented reality (AR) applications in medicine. While medical applications of VR have historically seen greater adoption from patient-as-user applications, the new era of VR/AR technology has created...
journal_title:Journal of digital imaging
pub_type: 杂志文章,评审
doi:10.1007/s10278-018-0122-7
更新日期:2019-02-01 00:00:00
abstract::A teleradiology system acquires radiographic images from one location and transmits them to one or more distant sites where they are displayed and/or converted to hard-copy film recordings. The long-term goal of teleradiology research is to show that teleradiology systems can provide diagnostically equivalent results ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03167763
更新日期:1992-08-01 00:00:00
abstract::Rapid advances are changing the technology and applications of multidetector computed tomography (CT) scanners. The major increase in data associated with this new technology, however, breaks most commercial picture archiving and communication system (PACS) architectures by preventing them from delivering data in real...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-006-0925-9
更新日期:2006-01-01 00:00:00
abstract::Picture archiving and communications system (PACS) in the context of an outpatient trauma care center asks for a high level of interaction between information systems to guarantee rapid image acquisition and distribution to the surgeon. During installation of the Innsbruck PACS, special aspects of traumatology had to ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168769
更新日期:1999-05-01 00:00:00
abstract::High-throughput, large-scale medical image computing demands tight integration of high-performance computing (HPC) infrastructure for data storage, job distribution, and image processing. The Vanderbilt University Institute for Imaging Science (VUIIS) Center for Computational Imaging (CCI) has constructed a large-scal...
journal_title:Journal of digital imaging
pub_type: 杂志文章,评审
doi:10.1007/s10278-018-0080-0
更新日期:2018-06-01 00:00:00
abstract::We quantitatively investigate the influence of image registration, using open-source software (3DSlicer), on kinetic analysis (Tofts model) of dynamic contrast enhanced MRI of early-stage breast cancer patients. We also show that registration computation time can be reduced by reducing the percent sampling (PS) of vox...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-020-00374-6
更新日期:2020-10-01 00:00:00
abstract::To improve radiology access to full uncompressed Digital Imaging and Communications in Medicine (DICOM) data sets, we evaluated satellite access to a DICOM server. Radiologists' home computers were connected by satellite to a Medweb DICOM server (Medweb, San Francisco, CA). A 10.2-kb data set containing a 19-image hea...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168799
更新日期:1999-05-01 00:00:00
abstract::An integrated picture archiving and communication system (PACS) is a large investment in both money and resources. With all of the components and systems contained in the PACS, a methodical set of protocols and procedures must be developed to test all aspects of the PACS within the short time allocated for contract co...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168789
更新日期:1999-05-01 00:00:00
abstract::The purpose of this communication is to report on the testing of the disaster recovery capability of our hierarchical storage management (HSM) system. Disaster recovery implementation is a requirement of every mission-critical information technology project. Picture archiving and communications systems (PACS) certainl...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03167652
更新日期:2000-05-01 00:00:00
abstract::We introduce a set of worksheets to facilitate standardized comparisons among scheduling systems, hospital information systems, radiology information systems, and picture archiving and communication systems vendors. For each system category, we provide worksheets to evaluate the features, performance, installation req...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168605
更新日期:1996-08-01 00:00:00
abstract::For a region-wide teleradiology network in Germany a vendor-independent Uptime-server concept was defined. The Uptime-server was realized for the availability check and prospective error-detection of the emergency teleradiology servers and clients based on encrypted digital imaging and communication in medicine (DICOM...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-006-1044-3
更新日期:2007-12-01 00:00:00
abstract::In the UK, physicists and radiographers perform routine quality control (QC) of digital mammography equipment at daily, weekly and monthly intervals. The tests performed and tolerances are specified by standard protocols. The manual nature of many of the tests introduces variability due to the positioning of regions o...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-014-9759-z
更新日期:2015-10-01 00:00:00
abstract::After several years of continuous operation, the utility of digital viewing stations as assessed by bedside clinicians has been investigated through the distribution of questionnaires to past and present users. The results of the questionnaire have indicated that the bedside physicians prefer using the workstations ov...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168415
更新日期:1993-02-01 00:00:00