An ROC study of chest radiographs: 2K Versus 4K high-resolution soft-copy images.

Abstract:

:Computed radiography of chest with a 4K image array was recently introduced. We performed a multiobserver study to compare the diagnostic accuracy of 2K (standard) and 4K (high quality) chest radiographs displayed on a 5-mega-pixel monitor (2K monitor). One hundred cases of posteroanterior chest radiographs (a total of 200 images) were selected by two chest radiologists. Those radiographs included pneumothorax (n = 14), nodules (n = 15), interstitial disease (n = 10), or neither abnormality (n = 61). These were interpreted by four radiologists in two separate sessions. They recorded their confidence scale for the presence or absence of abnormality. Diagnostic accuracy was determined by receiver operating characteristic (ROC) analysis for each observer. ROC analysis showed no statistically significant difference between the 2K and 4K modes for the detection of any of the different abnormalities by individual readers. Our preliminary study suggests that 2K mode would be sufficient for the detection of abnormality on chest radiograph and there is no considerable validity to incline toward the 4K mode in current picture archiving and communication system environment using 2K monitor. However, we think that additional investigation using more subtle parenchymal or rib lesion should be followed.

journal_name

J Digit Imaging

authors

Kim SY,Hwang YJ,Han YH,Seo JW,Lee JY,Kim YH,Cha SJ,Hur G,Lee SS

doi

10.1007/s10278-006-1048-z

subject

Has Abstract

pub_date

2007-12-01 00:00:00

pages

347-51

issue

4

eissn

0897-1889

issn

1618-727X

journal_volume

20

pub_type

杂志文章
  • Demonstration of digital radiographs by means of ink jet-printed paper copies: pilot study.

    abstract::Different digital medical images have been printed on paper with a continuous ink jet printer, and the quality has been evaluated. The emphasis has been on digital chest radiographs from a computed radiography system. The ink jet printing technique is described as well as the handling of the image data from image sour...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167806

    authors: Kirkhorn T,Kehler M,Nilsson J,Lyttkens K,Andersson B,Holmer NG

    更新日期:1992-11-01 00:00:00

  • Use of a thin-section archive and enterprise 3D software for long-term storage of thin-slice CT data sets.

    abstract::Rapid advances are changing the technology and applications of multidetector computed tomography (CT) scanners. The major increase in data associated with this new technology, however, breaks most commercial picture archiving and communication system (PACS) architectures by preventing them from delivering data in real...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-0925-9

    authors: Meenan C,Daly B,Toland C,Nagy P

    更新日期:2006-01-01 00:00:00

  • Classification of breast masses using selected shape, edge-sharpness, and texture features with linear and kernel-based classifiers.

    abstract::Breast masses due to benign disease and malignant tumors related to breast cancer differ in terms of shape, edge-sharpness, and texture characteristics. In this study, we evaluate a set of 22 features including 5 shape factors, 3 edge-sharpness measures, and 14 texture features computed from 111 regions in mammograms,...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-007-9102-z

    authors: Mu T,Nandi AK,Rangayyan RM

    更新日期:2008-06-01 00:00:00

  • Assessing the accuracy factors in the determination of postoperative acetabular cup orientation using hybrid 2D-3D registration.

    abstract::Single standard anteroposterior radiograph-based methods for measuring cup orientation following total hip arthroplasty (THA) are subject to substantial errors if the individual pelvic orientation with respect to X-ray plate is not taken into consideration. Previously, we proposed to use a hybrid 2D-3D registration sc...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-009-9226-4

    authors: Zheng G

    更新日期:2010-12-01 00:00:00

  • An effective approach of lesion segmentation within the breast ultrasound image based on the cellular automata principle.

    abstract::In this paper, a novel lesion segmentation within breast ultrasound (BUS) image based on the cellular automata principle is proposed. Its energy transition function is formulated based on global image information difference and local image information difference using different energy transfer strategies. First, an en...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9450-6

    authors: Liu Y,Cheng HD,Huang J,Zhang Y,Tang X

    更新日期:2012-10-01 00:00:00

  • Elastic registration of x-ray mammograms and three-dimensional magnetic resonance imaging data.

    abstract::Major problems in treating breast cancer are the early detection of tumors and accurate biopsy of small volumes of breast (mamma) tissue. This report presents an elastic registration algorithm of two x-ray mammograms and a corresponding magnetic resonance imaging (MRI) volume. To cope with the soft tissue deformation ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03190295

    authors: Ruiter NV,Müller TO,Stotzka R,Kaiser WA

    更新日期:2001-06-01 00:00:00

  • An algorithm for automatic segmentation and classification of magnetic resonance brain images.

    abstract::In this article, we describe the development and validation of an automatic algorithm to segment brain from extracranial tissues, and to classify intracranial tissues as cerebrospinal fluid (CSF), gray matter (GM), white matter (WM) or pathology. T1 weighted spin echo, dual echo fast spin echo (T2 weighted and proton ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168729

    authors: Erickson BJ,Avula RT

    更新日期:1998-05-01 00:00:00

  • Who You Gonna Call? Automatically Connecting Radiologists to the Right Clinician.

    abstract::Contacting clinicians to convey critical results is a critical part of radiology workflow, but many obstacles prevent easy and timely communication. Integration of radiology applications and workflow with an EHR-based patient coverage database demonstrated subjective and objective improvement in radiologist workflow a...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-017-9962-9

    authors: Filice R

    更新日期:2017-10-01 00:00:00

  • An artificial immune-activated neural network applied to brain 3D MRI segmentation.

    abstract::In this paper, a new neural network model inspired by the biological immune system functions is presented. The model, termed Artificial Immune-Activated Neural Network (AIANN), extracts classification knowledge from a training data set, which is then used to classify input patterns or vectors. The AIANN is based on a ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-007-9081-0

    authors: Younis A,Ibrahim M,Kabuka M,John N

    更新日期:2008-10-01 00:00:00

  • SCAR R&D Symposium 2003: comparing the efficacy of 5-MP CRT versus 3-MP LCD in the evaluation of interstitial lung disease.

    abstract::The efficacy of two medical-grade, self-calibrating, gray scale displays were compared with regard to impact on sensitivity and specificity for the detection of interstitial lung disease (ILD) on computed radiographs (CR). The displays were a 5-megapixel (MP) cathode ray tube (CRT) device and a 3-MP liquid crystal dis...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-004-1013-7

    authors: Langer S,Bartholmai B,Fetterly K,Harmsen S,Ryan W,Erickson B,Andriole K,Carrino J

    更新日期:2004-09-01 00:00:00

  • Combining multi-scale feature fusion with multi-attribute grading, a CNN model for benign and malignant classification of pulmonary nodules.

    abstract::Lung cancer has the highest mortality rate of all cancers, and early detection can improve survival rates. In the recent years, low-dose CT has been widely used to detect lung cancer. However, the diagnosis is limited by the subjective experience of doctors. Therefore, the main purpose of this study is to use convolut...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-020-00333-1

    authors: Zhao J,Zhang C,Li D,Niu J

    更新日期:2020-08-01 00:00:00

  • 3D Brain Imaging in Vascular Segmentation of Cerebral Venous Sinuses.

    abstract::The three-dimensional (3D) visualization of dural venous sinuses (DVS) networks is desired by surgical trainers to create a clear mental picture of the neuroanatomical orientation of the complex cerebral anatomy. Our purpose is to document those identified during routine 3D venography created through 3D models using t...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0125-4

    authors: Karakas AB,Govsa F,Ozer MA,Eraslan C

    更新日期:2019-04-01 00:00:00

  • Effect of Interventional Program on the Utilization of PACS in Point-of-Care Ultrasound.

    abstract::While the implementation of Picture Archiving and Communication Systems (PACS) has revolutionized the field of radiology, there has been considerably less utilization of PACS by emergency physicians with point-of-care ultrasound. Benefits of PACS archival of images include improved quality assurance, preservation of i...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-016-9893-x

    authors: Kessler R,Stowell JR,Vogel JA,Liao MM,Kendall JL

    更新日期:2016-12-01 00:00:00

  • DEWEY: the DICOM-enabled workflow engine system.

    abstract::Workflow is a widely used term to describe the sequence of steps to accomplish a task. The use of workflow technology in medicine and medical imaging in particular is limited. In this article, we describe the application of a workflow engine to improve workflow in a radiology department. We implemented a DICOM-enabled...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9661-0

    authors: Erickson BJ,Langer SG,Blezek DJ,Ryan WJ,French TL

    更新日期:2014-06-01 00:00:00

  • Solution for nonuniformities and spatial noise in medical LCD displays by using pixel-based correction.

    abstract::Liquid crystal displays (LCD) are rapidly replacing cathode ray tube displays (CRT) for medical imaging. LCD technology has improved significantly in the last few years and has important advantages over CRT. However, there are still some aspects of LCD that raise questions as to the usefulness of liquid crystal displa...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-005-2939-0

    authors: Kimpe T,Xthona A,Matthijs P,De Paepe L

    更新日期:2005-09-01 00:00:00

  • Automatically correlating clinical findings and body locations in radiology reports using MedLEE.

    abstract::In this paper, we describe and evaluate a system that extracts clinical findings and body locations from radiology reports and correlates them. The system uses Medical Language Extraction and Encoding System (MedLEE) to map the reports' free text to structured semantic representations of their content. A lightweight r...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9411-0

    authors: Sevenster M,van Ommering R,Qian Y

    更新日期:2012-04-01 00:00:00

  • Online availability check of teleradiology components.

    abstract::For a region-wide teleradiology network in Germany a vendor-independent Uptime-server concept was defined. The Uptime-server was realized for the availability check and prospective error-detection of the emergency teleradiology servers and clients based on encrypted digital imaging and communication in medicine (DICOM...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-1044-3

    authors: Weisser G,Ruggiero S,Runa A,Düber C,Neff W,Walz M

    更新日期:2007-12-01 00:00:00

  • Indexing thoracic CT reports using a preliminary version of a standardized radiological lexicon (RadLex).

    abstract:INTRODUCTION:To validate a preliminary version of a radiological lexicon (RadLex) against terms found in thoracic CT reports and to index report content in RadLex term categories. MATERIAL AND METHODS:Terms from a random sample of 200 thoracic CT reports were extracted using a text processor and matched against RadLex...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-007-9051-6

    authors: Marwede D,Schulz T,Kahn T

    更新日期:2008-12-01 00:00:00

  • Patient-specific three-dimensional composite bone models for teaching and operation planning.

    abstract:BACKGROUND:Orthopedic trauma care relies on two-dimensional radiograms both before and during the operation. Understanding the three-dimensional nature of complex fractures on plain radiograms is challenging. Modern fluoroscopes can acquire three-dimensional volume datasets even during an operation, but the device limi...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-007-9078-8

    authors: Matthews F,Messmer P,Raikov V,Wanner GA,Jacob AL,Regazzoni P,Egli A

    更新日期:2009-10-01 00:00:00

  • A novel medical image quality index.

    abstract::A novel medical image quality index using grey relational coefficient calculation is proposed in this study. Three medical modalities, DR, CT and MRI, using 30 or 60 images with a total of 120 images used for experimentation. These images were first compressed at ten different compression ratios (10 ∼ 100) using a med...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-010-9353-y

    authors: Lin SC,Lin YC,Feng WS,Wu JM,Chen TJ

    更新日期:2011-10-01 00:00:00

  • Integrating patient digital photographs with medical imaging examinations.

    abstract::We introduce the concept, benefits, and general architecture for acquiring, storing, and displaying digital photographs along with medical imaging examinations. We also discuss a specific implementation built around an Android-based system for simultaneously acquiring digital photographs along with portable radiograph...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-013-9579-6

    authors: Ramamurthy S,Bhatti P,Arepalli CD,Salama M,Provenzale JM,Tridandapani S

    更新日期:2013-10-01 00:00:00

  • Scoliosis evaluation by direct digital radiography and computerized post-processing.

    abstract::With the introduction of direct digital radiography into clinical practice, there are opportunities to provide faster and more reliable ways of performing traditional radiological tasks. A technique was developed for evaluating and measuring scoliosis, which involves the computerized stitching of a radiograph of the t...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-002-5033-x

    authors: Berliner L,Kreang-Arekul S,Kaufman L

    更新日期:2002-01-01 00:00:00

  • A Decision-Support Tool for Renal Mass Classification.

    abstract::We investigate the viability of statistical relational machine learning algorithms for the task of identifying malignancy of renal masses using radiomics-based imaging features. Features characterizing the texture, signal intensity, and other relevant metrics of the renal mass were extracted from multiphase contrast-e...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0100-0

    authors: Kunapuli G,Varghese BA,Ganapathy P,Desai B,Cen S,Aron M,Gill I,Duddalwar V

    更新日期:2018-12-01 00:00:00

  • Prostate tissue texture feature extraction for suspicious regions identification on TRUS images.

    abstract::In this work, two different approaches are proposed for region of interest (ROI) segmentation using transrectal ultrasound (TRUS) images. The two methods aim to extract informative features that are able to characterize suspicious regions in the TRUS images. Both proposed methods are based on multi-resolution analysis...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-008-9124-1

    authors: Mohamed SS,Li J,Salama MM,Freeman G

    更新日期:2009-10-01 00:00:00

  • MRI Radiomics for the Prediction of Fuhrman Grade in Clear Cell Renal Cell Carcinoma: a Machine Learning Exploratory Study.

    abstract::The Fuhrman nuclear grade is a recognized prognostic factor for patients with clear cell renal cell carcinoma (CCRCC) and its pre-treatment evaluation significantly affects decision-making in terms of management. In this study, we aimed to assess the feasibility of a combined approach of radiomics and machine learning...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-020-00336-y

    authors: Stanzione A,Ricciardi C,Cuocolo R,Romeo V,Petrone J,Sarnataro M,Mainenti PP,Improta G,De Rosa F,Insabato L,Brunetti A,Maurea S

    更新日期:2020-08-01 00:00:00

  • Characterization of radiologists' search strategies for lung nodule detection: slice-based versus volumetric displays.

    abstract::The goal of this study was to assess whether radiologists' search paths for lung nodule detection in chest computed tomography (CT) between different rendering and display schemes have reliable properties that can be exploited as an indicator of ergonomic efficiency for the purpose of comparing different display parad...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-007-9076-x

    authors: Wang XH,Durick JE,Lu A,Herbert DL,Golla SK,Foley K,Piracha CS,Shinde DD,Shindel BE,Fuhrman CR,Britton CA,Strollo DC,Shang SS,Lacomis JM,Good WF

    更新日期:2008-10-01 00:00:00

  • Minimizing Digital Imaging and Communications in Medicine (DICOM) Modality Worklist patient/study selection errors.

    abstract::Frequently when patient and study identification information (patient name, patient identification, date of birth, sex, and accession number) are manually entered at a modality, typographical errors occur that have to be corrected before the acquired images can be matched to the proper patient and study on a picture a...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03190323

    authors: Kuzmak PM,Dayhoff RE

    更新日期:2001-06-01 00:00:00

  • Should radiology IT be owned by the chief information officer?

    abstract::Considerable debate within the medical community has focused on the optimal location of information technology (IT) support groups on the organizational chart. The challenge has been to marry local accountability and physician acceptance of IT with the benefits gained by the economies of scale achieved by centralized ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-009-9196-6

    authors: Channin DS,Bowers G,Nagy P

    更新日期:2009-06-01 00:00:00

  • CT and MR image fusion scheme in nonsubsampled contourlet transform domain.

    abstract::Fusion of CT and MR images allows simultaneous visualization of details of bony anatomy provided by CT image and details of soft tissue anatomy provided by MR image. This helps the radiologist for the precise diagnosis of disease and for more effective interventional treatment procedures. This paper aims at designing ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9664-x

    authors: Ganasala P,Kumar V

    更新日期:2014-06-01 00:00:00

  • A breast density index for digital mammograms based on radiologists' ranking.

    abstract::The purpose of this study was to develop and evaluate a computerized method of calculating a breast density index (BDI) from digitized mammograms that was designed specifically to model radiologists' perception of breast density. A set of 153 pairs of digitized mammograms (cranio-caudal, CC, and mediolateral oblique, ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168733

    authors: Boone JM,Lindfors KK,Beatty CS,Seibert JA