Scoliosis evaluation by direct digital radiography and computerized post-processing.

Abstract:

:With the introduction of direct digital radiography into clinical practice, there are opportunities to provide faster and more reliable ways of performing traditional radiological tasks. A technique was developed for evaluating and measuring scoliosis, which involves the computerized stitching of a radiograph of the thoracic spine with a radiograph of the lumbar spine. A technique is provided for real-time, graphic feedback during the stitching process, as well as during calculation and display of the Cobb angle to ensure accuracy. Initial data indicates an accuracy within 1 to 2 degrees. The time required to stitch the two images and measure the Cobb angle is on the average of 5 minutes per case. Using computerized techniques of image stitching and angle calculation, with real-time graphical feedback, the task of scoliosis evaluation is more accurate, less time consuming, and prone to fewer human errors. The requirement for special film cassettes is also eliminated.

journal_name

J Digit Imaging

authors

Berliner L,Kreang-Arekul S,Kaufman L

doi

10.1007/s10278-002-5033-x

subject

Has Abstract

pub_date

2002-01-01 00:00:00

pages

270-4

eissn

0897-1889

issn

1618-727X

journal_volume

15 Suppl 1

pub_type

杂志文章
  • What is a wiki, and how can it be used in resident education?

    abstract::Training as a radiology resident is a complex task. Residents frequently encounter multiple hospital systems, each with unique workflow patterns and heterogenous information systems. We identified an opportunity to ease some of the resulting anxiety and frustration by centralizing high-quality resources using a wiki. ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-010-9292-7

    authors: Kohli MD,Bradshaw JK

    更新日期:2011-02-01 00:00:00

  • Contrast information of digital imaging in laser film digitizer and display monitor.

    abstract::A 10-bit or 12-bit gray scale is provided in commercial laser film digitizers. The true contrast resolution on the digitized image within a laser spot area of 200 microns in diameter is limited by both the quantum mottle and instrumentation noise. In this report, we investigated the mean value, standard deviation, and...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03170571

    authors: Lo SC,Gaskill JW,Mun SK,Krasner BH

    更新日期:1990-05-01 00:00:00

  • NIRViz: 3D visualization software for multimodality optical imaging using visualization toolkit (VTK) and insight segmentation toolkit (ITK).

    abstract::Optical imaging using near-infrared light is used for noninvasive probing of tissues to recover vascular and molecular status of healthy and diseased tissues using hemoglobin contrast arising due to absorption of light. While multimodality optical techniques exist, visualization techniques in this area are limited. Ad...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9362-5

    authors: Taka SJ,Srinivasan S

    更新日期:2011-12-01 00:00:00

  • Interactive image enhancement of CR and DR images.

    abstract::There is continual pressure on the radiology department to increase its productivity. Two important links to productivity in the computed/digital radiography (CR/DR) workflow chain are the postprocessing step by technologists and the primary diagnosis step by radiologists, who may apply additional image enhancements t...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-004-1000-z

    authors: Thomas MA,Rowberg AH,Langer SG,Kim Y

    更新日期:2004-09-01 00:00:00

  • A study for watermark methods appropriate to medical images.

    abstract::The network system, including the picture archiving and communication system (PACS), is essential in hospital and medical imaging fields these days. Many medical images are accessed and processed on the web, as well as in PACS. Therefore, any possible accidents caused by the illegal modification of medical images must...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03190332

    authors: Cho Y,Ahn B,Kim JS,Kim IY,Kim SI

    更新日期:2001-06-01 00:00:00

  • Toward Data-Driven Radiology Education-Early Experience Building Multi-Institutional Academic Trainee Interpretation Log Database (MATILDA).

    abstract::The residency review committee of the Accreditation Council of Graduate Medical Education (ACGME) collects data on resident exam volume and sets minimum requirements. However, this data is not made readily available, and the ACGME does not share their tools or methodology. It is therefore difficult to assess the integ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s10278-016-9872-2

    authors: Chen PH,Loehfelm TW,Kamer AP,Lemmon AB,Cook TS,Kohli MD

    更新日期:2016-12-01 00:00:00

  • DEWEY: the DICOM-enabled workflow engine system.

    abstract::Workflow is a widely used term to describe the sequence of steps to accomplish a task. The use of workflow technology in medicine and medical imaging in particular is limited. In this article, we describe the application of a workflow engine to improve workflow in a radiology department. We implemented a DICOM-enabled...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9661-0

    authors: Erickson BJ,Langer SG,Blezek DJ,Ryan WJ,French TL

    更新日期:2014-06-01 00:00:00

  • Feature-Motivated Simplified Adaptive PCNN-Based Medical Image Fusion Algorithm in NSST Domain.

    abstract::Multimodality medical image fusion plays a vital role in diagnosis, treatment planning, and follow-up studies of various diseases. It provides a composite image containing critical information of source images required for better localization and definition of different organs and lesions. In the state-of-the-art imag...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-015-9806-4

    authors: Ganasala P,Kumar V

    更新日期:2016-02-01 00:00:00

  • Towards an Information Infrastructure for Medical Image Sharing.

    abstract::Information infrastructures involve the notion of a shared, open infrastructure, constituting a space where people, organizations, and technical components associate to develop an activity. The current infrastructure for medical image sharing, based on PACS/DICOM technologies, does not constitute an information infras...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00243-x

    authors: Motta GHMB,Araújo DAB,Lucena-Neto JR,Azevedo-Marques PM,Cordeiro SS,Araújo-Neto SA

    更新日期:2020-02-01 00:00:00

  • CT and MR image fusion scheme in nonsubsampled contourlet transform domain.

    abstract::Fusion of CT and MR images allows simultaneous visualization of details of bony anatomy provided by CT image and details of soft tissue anatomy provided by MR image. This helps the radiologist for the precise diagnosis of disease and for more effective interventional treatment procedures. This paper aims at designing ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9664-x

    authors: Ganasala P,Kumar V

    更新日期:2014-06-01 00:00:00

  • Thresholding histogram equalization.

    abstract::The drawbacks of adaptive histogram equalization techniques are the loss of definition on the edges of the object and overenhancement of noise in the images. These drawbacks can be avoided if the noise is excluded in the equalization transformation function computation. A method has been developed to separate the hist...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-001-0103-z

    authors: Chuang KS,Chen S,Hwang IM

    更新日期:2001-12-01 00:00:00

  • Automated pediatric abdominal effective diameter measurements versus age-predicted body size for normalization of CT dose.

    abstract::There has been increasing interest in adjusting CT radiation dose data for patient body size. A method for automated computation of the abdominal effective diameter of a patient from a CT image has previously only been tested in adult patients. In this work, we tested the method on a set of 128 pediatric patients aged...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9623-6

    authors: Cheng PM,Vachon LA,Duddalwar VA

    更新日期:2013-12-01 00:00:00

  • Enhancement of storage phosphor plate images: a C-language program.

    abstract::A C-language software program has been developed for emulating the image enhancement processing of a storage phosphor plate system. This software has been implemented on a VAX 3400 computer. There are 2,100 lines of C-language code in the program. There are seven parameters used to specify the degree of enhancement. T...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167825

    authors: Templeton AW,Wetzel LH,Cook LT,Harrison LA,Eckard DA,Anderson WH,Hensley KS

    更新日期:1992-02-01 00:00:00

  • Strategic thinking for radiology.

    abstract::We have now analyzed the use and benefits of four Strategic Thinking Tools for Radiology: the Vision Statement, the High Five, the Two-by-Two, and Real-Win-Worth. Additional tools will be provided during the tutorial. The tools provided above should be considered as examples. They all contain the 10 benefits outlined ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168638

    authors: Schilling RB

    更新日期:1997-08-01 00:00:00

  • A method for computing general sacroiliac screw corridors based on CT scans of the pelvis.

    abstract::Sacroiliac (SI) joint dislocations and sacral fractures of the pelvis can be stabilized by SI screws; however, screw insertion into a sacral isthmus region is risky for the adjacent neurovascular structures. Therefore, shape analyses of general SI screw corridors or safety zones are of great surgical interest; however...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-010-9327-0

    authors: Noser H,Radetzki F,Stock K,Mendel T

    更新日期:2011-08-01 00:00:00

  • Demonstration of digital radiographs by means of ink jet-printed paper copies: pilot study.

    abstract::Different digital medical images have been printed on paper with a continuous ink jet printer, and the quality has been evaluated. The emphasis has been on digital chest radiographs from a computed radiography system. The ink jet printing technique is described as well as the handling of the image data from image sour...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167806

    authors: Kirkhorn T,Kehler M,Nilsson J,Lyttkens K,Andersson B,Holmer NG

    更新日期:1992-11-01 00:00:00

  • Detection of microcalcifications by means of multiscale methods and statistical techniques.

    abstract::The detection of clustered microcalcifications can help the radiologist to detect early breast cancer. Microcalcifications exhibit some important characteristics, such as small size and high luminosity. Use of a computer-aided diagnosis (CAD) method can prevent them being overlooked. In this report, a multiresolution ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167672

    authors: Mata Campos R,Vidal EM,Nava E,Martínez-Morillo M,Sendra F

    更新日期:2000-05-01 00:00:00

  • Of Mice and Roentgen: Radiologist Satisfaction with a Non-conventional 13-Button Mouse-One Institution's Experience.

    abstract::Increasing radiologic exam volume and complexity necessitates leveraging advanced hardware solutions to optimize workflow efficiency. We evaluated radiologist satisfaction of a programmable 13-button non-conventional mouse compared to a conventional three-button mouse in daily interpretation workflow following a brief...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-018-0094-7

    authors: Denton K,Haider I,Hill J,Hunt SL,Ash R

    更新日期:2018-12-01 00:00:00

  • Classification of CT Scan Images of Lungs Using Deep Convolutional Neural Network with External Shape-Based Features.

    abstract::In this paper, a simplified yet efficient architecture of a deep convolutional neural network is presented for lung image classification. The images used for classification are computed tomography (CT) scan images obtained from two scientifically used databases available publicly. Six external shape-based features, vi...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00245-9

    authors: Srivastava V,Purwar RK

    更新日期:2020-02-01 00:00:00

  • Distributing digital imaging and communications in medicine data and optimizing access over satellite networks.

    abstract::To improve radiology access to full uncompressed Digital Imaging and Communications in Medicine (DICOM) data sets, we evaluated satellite access to a DICOM server. Radiologists' home computers were connected by satellite to a Medweb DICOM server (Medweb, San Francisco, CA). A 10.2-kb data set containing a 19-image hea...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168799

    authors: Ernst RD,Kawashima A,Shepherd W,Tamm EP,Sandler CM

    更新日期:1999-05-01 00:00:00

  • Quantifying Analysis of Uncertainty in Medical Reporting: Creation of User and Context-Specific Uncertainty Profiles.

    abstract::While uncertainty is ubiquitous in medical practice, minimal work to date has been performed to analyze the cause and effect relationship between uncertainty and patient outcomes. In medical imaging practice, uncertainty in the radiology report has been well documented to be a source of clinician dissatisfaction. Befo...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-018-0057-z

    authors: Reiner BI

    更新日期:2018-08-01 00:00:00

  • Analog to digital workflow improvement: a quantitative study.

    abstract::This study tracked a radiology department's conversion from utilization of a Kodak Amber analog system to a Kodak DirectView DR 5100 digital system. Through the use of ProModel Optimization Suite, a workflow simulation software package, significant quantitative information was derived from workflow process data measur...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-0770-x

    authors: Wideman C,Gallet J

    更新日期:2006-01-01 00:00:00

  • The effects of ambient lighting in chest radiology reading rooms.

    abstract::Under typical dark chest radiography reading room conditions, a radiologist's pupils contract and dilate as their visual focus intermittently shifts between the high luminance monitor and the darker background wall, resulting in increased visual fatigue and degradation of diagnostic performance. A controlled increase ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9459-5

    authors: Pollard BJ,Samei E,Chawla AS,Beam C,Heyneman LE,Koweek LM,Martinez-Jimenez S,Washington L,Hashimoto N,McAdams HP

    更新日期:2012-08-01 00:00:00

  • Adding a microcomputer bar-code network to a minicomputer-based radiology information system.

    abstract::A bar-code terminal network under software control of a microcomputer was added to the minicomputer-based radiology information system at the Medical College of Georgia in Augusta. The bar-code network was specifically installed to address the inherent inaccuracies occurring when procedure information was entered at t...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168107

    authors: David G,Gregory S

    更新日期:1990-02-01 00:00:00

  • A content-boosted collaborative filtering algorithm for personalized training in interpretation of radiological imaging.

    abstract::Devising a method that can select cases based on the performance levels of trainees and the characteristics of cases is essential for developing a personalized training program in radiology education. In this paper, we propose a novel hybrid prediction algorithm called content-boosted collaborative filtering (CBCF) to...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-014-9678-z

    authors: Lin H,Yang X,Wang W

    更新日期:2014-08-01 00:00:00

  • Towards a repository for standardized medical image and signal case data annotated with ground truth.

    abstract::Validation of medical signal and image processing systems requires quality-assured, representative and generally acknowledged databases accompanied by appropriate reference (ground truth) and clinical metadata, which are composed laboriously for each project and are not shared with the scientific community. In our vis...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9428-4

    authors: Deserno TM,Welter P,Horsch A

    更新日期:2012-04-01 00:00:00

  • Sophisticated hospital information system/radiology information system/picture archiving and communications system (PACS) integration in a large-scale traumatology PACS.

    abstract::Picture archiving and communications system (PACS) in the context of an outpatient trauma care center asks for a high level of interaction between information systems to guarantee rapid image acquisition and distribution to the surgeon. During installation of the Innsbruck PACS, special aspects of traumatology had to ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168769

    authors: Peer S,Vogl R,Peer R,Jaschke W

    更新日期:1999-05-01 00:00:00

  • The effect of lossy discrete cosine transform compression on subtle bone fractures.

    abstract::Extensive research efforts have been devoted to the feasibility of picture archiving and communication systems (PACS) in recent years. The advantages of PACS are numerous but mainly include reduced cost and improvement in the operational efficiency of a PACS-based radiology department. In digital radiography, images a...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168839

    authors: Toney MO,Dominguez R,Dao HN,Simmons G

    更新日期:1997-11-01 00:00:00

  • Diagnostic accuracy of film-based, TIFF, and wavelet compressed digital temporomandibular joint images.

    abstract::The purpose of this research was to determine if digitization and the application of various compression routines to digital images of temporomandibular joint (TMJ) radiographs would diminish observer accuracy in the detection of specific osseous characteristics associated with TMJ degenerative joint disease (DJD). Ni...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168339

    authors: Trapnell CJ,Scarfe WC,Cook JH,Silvejra AM,Regennitter FJ,Haskell BS

    更新日期:2000-02-01 00:00:00

  • Endowing a Content-Based Medical Image Retrieval System with Perceptual Similarity Using Ensemble Strategy.

    abstract::Content-based medical image retrieval (CBMIR) is a powerful resource to improve differential computer-aided diagnosis. The major problem with CBMIR applications is the semantic gap, a situation in which the system does not follow the users' sense of similarity. This gap can be bridged by the adequate modeling of simil...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-015-9809-1

    authors: Bedo MV,Pereira Dos Santos D,Ponciano-Silva M,de Azevedo-Marques PM,Ferreira de Carvalho AP,Traina C Jr

    更新日期:2016-02-01 00:00:00