Precise measurement of vertebral bone density using computed tomography without the use of an external reference phantom.

Abstract:

:Bone density measurement by quantitative computed tomography (QCT) commonly uses an external reference phantom to decrease scan-to-scan and scanner-to-scanner variability. However, the peripheral location of these phantoms and other phantom variables is also responsible for a measurable degradation in accuracy and precision. Due to non-uniform artifacts such as beam hardening, scatter, and volume averaging, the ideal reference phantom should be as close to the target tissue as possible. This investigation developed and tested a computer program that uses paraspinal muscle and fat tissue as internal reference standards in an effort to eliminate the need for an external phantom. Because of their proximity, these internal reference tissues can be assumed to reflect more accurately the local changes in the x-ray spectra and scatter distribution at the target tissue. A user interactive computerized histogram plotting technique enabled the derivation of reproducible CT numbers for muscle, fat, and trabecular bone. Preliminary results indicate that the use of internal reference tissues with the histogram technique may improve reproducibility of scan-to-scan measurements as well as inter-scanner precision. Reproducibility studies on 165 images with intentional region-of-interest (ROI) mispositioning of 1.5, 2.5, or 3.5 mm yielded a precision of better than 1% for normals and 1% to 2% for osteoporotic patients--a twofold improvement over the precision from similar tests using the standard technique with an external reference phantom. Such improvements in precision are essential for QCT to be clinically useful as a noninvasive modality for measurement of the very small annual changes in bone mineral density.

journal_name

J Digit Imaging

authors

Boden SD,Goodenough DJ,Stockham CD,Jacobs E,Dina T,Allman RM

doi

10.1007/BF03168013

subject

Has Abstract

pub_date

1989-02-01 00:00:00

pages

31-8

issue

1

eissn

0897-1889

issn

1618-727X

journal_volume

2

pub_type

杂志文章
  • Picture archiving and communication systems and related developments in Sweden.

    abstract::Large PACS (Picture Archiving and Communication Systems) installations do not yet exist in Sweden, but some hospitals have had experience with limited PACS activities. At present there are four mini PACS installations in radiology departments and about 12 teleradiology systems in use in Sweden. A couple of small Swedi...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168157

    authors: Olsson S

    更新日期:1991-08-01 00:00:00

  • PDA-phone-based instant transmission of radiological images over a CDMA network by combining the PACS screen with a Bluetooth-interfaced local wireless link.

    abstract::Remote teleconsultation by specialists is important for timely, correct, and specialized emergency surgical and medical decision making. In this paper, we designed a new personal digital assistant (PDA)-phone-based emergency teleradiology system by combining cellular communication with Bluetooth-interfaced local wirel...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-007-9002-2

    authors: Kim DK,Yoo SK,Park JJ,Kim SH

    更新日期:2007-06-01 00:00:00

  • Prostate tissue texture feature extraction for suspicious regions identification on TRUS images.

    abstract::In this work, two different approaches are proposed for region of interest (ROI) segmentation using transrectal ultrasound (TRUS) images. The two methods aim to extract informative features that are able to characterize suspicious regions in the TRUS images. Both proposed methods are based on multi-resolution analysis...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-008-9124-1

    authors: Mohamed SS,Li J,Salama MM,Freeman G

    更新日期:2009-10-01 00:00:00

  • DEWEY: the DICOM-enabled workflow engine system.

    abstract::Workflow is a widely used term to describe the sequence of steps to accomplish a task. The use of workflow technology in medicine and medical imaging in particular is limited. In this article, we describe the application of a workflow engine to improve workflow in a radiology department. We implemented a DICOM-enabled...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9661-0

    authors: Erickson BJ,Langer SG,Blezek DJ,Ryan WJ,French TL

    更新日期:2014-06-01 00:00:00

  • MRIdb: medical image management for biobank research.

    abstract::Clinical picture archiving and communications systems provide convenient, efficient access to digital medical images from multiple modalities but can prove challenging to deploy, configure and use. MRIdb is a self-contained image database, particularly suited to the storage and management of magnetic resonance imaging...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9604-9

    authors: Woodbridge M,Fagiolo G,O'Regan DP

    更新日期:2013-10-01 00:00:00

  • The effects of ambient lighting in chest radiology reading rooms.

    abstract::Under typical dark chest radiography reading room conditions, a radiologist's pupils contract and dilate as their visual focus intermittently shifts between the high luminance monitor and the darker background wall, resulting in increased visual fatigue and degradation of diagnostic performance. A controlled increase ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-012-9459-5

    authors: Pollard BJ,Samei E,Chawla AS,Beam C,Heyneman LE,Koweek LM,Martinez-Jimenez S,Washington L,Hashimoto N,McAdams HP

    更新日期:2012-08-01 00:00:00

  • One Night in the ED.

    abstract::Radiology 2.0: One Night in the ED is an app that presents users with scrollable CT images for common scenarios found in any Emergency Department (ED). A great tool for a junior resident before starting call, it allows the user to build confidence by experiencing a simulated environment of viewing all images of a case...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-015-9797-1

    authors: Drexler IR

    更新日期:2015-08-01 00:00:00

  • A perceptual evaluation of JPEG 2000 image compression for digital mammography: contrast-detail characteristics.

    abstract::In this investigation the effect of JPEG 2000 compression on the contrast-detail (CD) characteristics of digital mammography images was studied using an alternative forced choice (AFC) technique. Images of a contrast-detail phantom, acquired using a clinical full-field digital mammography system, were compressed using...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-003-1728-x

    authors: Suryanarayanan S,Karellas A,Vedantham S,Waldrop SM,D'Orsi CJ

    更新日期:2004-03-01 00:00:00

  • Integrating an Ontology of Radiology Differential Diagnosis with ICD-10-CM, RadLex, and SNOMED CT.

    abstract::An ontology offers a human-readable and machine-computable representation of the concepts in a domain and the relationships among them. Mappings between ontologies enable the reuse and interoperability of biomedical knowledge. We sought to map concepts of the Radiology Gamuts Ontology (RGO), an ontology that links dis...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00186-3

    authors: Filice RW,Kahn CE Jr

    更新日期:2019-04-01 00:00:00

  • Optimizing technology development and adoption in medical imaging using the principles of innovation diffusion, part II: practical applications.

    abstract::Successful adoption of new technology development can be accentuated by learning and applying the scientific principles of innovation diffusion. This is of particular importance to areas within the medical imaging practice which have lagged in innovation; perhaps, the most notable of which is reporting which has remai...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-011-9409-7

    authors: Reiner BI

    更新日期:2012-02-01 00:00:00

  • Comparative performance analysis of state-of-the-art classification algorithms applied to lung tissue categorization.

    abstract::In this paper, we compare five common classifier families in their ability to categorize six lung tissue patterns in high-resolution computed tomography (HRCT) images of patients affected with interstitial lung diseases (ILD) and with healthy tissue. The evaluated classifiers are naive Bayes, k-nearest neighbor, J48 d...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-008-9158-4

    authors: Depeursinge A,Iavindrasana J,Hidki A,Cohen G,Geissbuhler A,Platon A,Poletti PA,Müller H

    更新日期:2010-02-01 00:00:00

  • Extraction of microcalcifications in digital mammograms using regional watershed.

    abstract::In this report, a novel technique is proposed for computer-aided automatic extraction of microcalcifications in a digital mammogram. First, the microcalcifications are detected by morphological filtering, followed by entropy-based thresholding. Next, the microcalcifications are segmented by computing regional watershe...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167642

    authors: Bhajammanavar VM,Keong KC,Krishnan SM

    更新日期:2000-05-01 00:00:00

  • Information retrieval for teaching files: a preliminary study.

    abstract::A computer algorithm for information retrieval from an electronic teaching file has been developed. This index enables the user to retrieve cases from a teaching file, based on the input of a combination of features. The algorithm is based on nearest neighbor analysis, and is programmed in the "C" language. A teaching...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167602

    authors: Bramble JM,Insana MF,Dwyer SJ 3rd

    更新日期:1990-08-01 00:00:00

  • CT and MR image fusion scheme in nonsubsampled contourlet transform domain.

    abstract::Fusion of CT and MR images allows simultaneous visualization of details of bony anatomy provided by CT image and details of soft tissue anatomy provided by MR image. This helps the radiologist for the precise diagnosis of disease and for more effective interventional treatment procedures. This paper aims at designing ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-013-9664-x

    authors: Ganasala P,Kumar V

    更新日期:2014-06-01 00:00:00

  • Large-Scale Assessment of Scan-Time Variability and Multiple-Procedure Efficiency for Cross-Sectional Neuroradiological Exams in Clinical Practice.

    abstract::Scheduling of CT and MR exams requires reasonable estimates for expected scan duration. However, scan-time variability and efficiency gains from combining multiple exams are not quantitatively well characterized. In this work, we developed an informatics approach to quantify typical duration, duration variability, and...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00252-w

    authors: Zhang R,Narra VR,Kansagra AP

    更新日期:2020-02-01 00:00:00

  • Challenges associated with interfacing computed tomography to a picture archiving and communication system at the Baltimore Veterans Affairs Medical Center--a historical perspective.

    abstract::The interfacing of digital image acquisition modalities to the picture archiving and communication system (PACS) plays a major part in the conversion from a traditional film-based radiology practice to one that relies almost entirely on soft-copy reading. The Baltimore Veterans Affairs Medical Center (VAMC) is one of ...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03167632

    authors: Kuzmak PM,Reiner BI,Siegel EL,Severance SM,Dayhoff RE

    更新日期:2000-05-01 00:00:00

  • Digital processing of radiographic images from PACS to publishing.

    abstract::Several studies have addressed the implications of filmless radiologic imaging on telemedicine, diagnostic ability, and electronic teaching files. However, many publishers still require authors to submit hard-copy images for publication of articles and textbooks. This study compares the quality digital images directly...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-001-0019-7

    authors: Christian ME,Davidson HC,Wiggins RH 3rd,Berges G,Cannon G,Jackson G,Chapman B,Harnsberger HR

    更新日期:2001-03-01 00:00:00

  • Panoramic dental radiography using a charge-coupled device receptor.

    abstract::Panoramic radiography using a slit beam and film/screen receptor is standard for the emergency room evaluation of mandibular fractures and also in dentistry. This study compared the spatial resolution, area distortion factors, and the dosage considerations for a panoramic system where standard film/screen and a charge...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168293

    authors: Farman AG,Farman TT

    更新日期:1998-08-01 00:00:00

  • A filmless radiology teaching conference system for pertinent displaying and image searching.

    abstract::To solve the problems of image displays in filmless radiology conferences for the purpose of teaching, we made an experimental design of a conference system with dual 50-in. plasma monitors for displaying larger images and a shared folder containing shortcuts to images for quick display during conferences on the deskt...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-007-9095-7

    authors: Abe K,Narata M,Tanaka I,Takahashi M,Igarashi A,Sasaki T,Matsuyama K,Tohi N,Kosuda S

    更新日期:2009-12-01 00:00:00

  • Distributing digital imaging and communications in medicine data and optimizing access over satellite networks.

    abstract::To improve radiology access to full uncompressed Digital Imaging and Communications in Medicine (DICOM) data sets, we evaluated satellite access to a DICOM server. Radiologists' home computers were connected by satellite to a Medweb DICOM server (Medweb, San Francisco, CA). A 10.2-kb data set containing a 19-image hea...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168799

    authors: Ernst RD,Kawashima A,Shepherd W,Tamm EP,Sandler CM

    更新日期:1999-05-01 00:00:00

  • Towards an Information Infrastructure for Medical Image Sharing.

    abstract::Information infrastructures involve the notion of a shared, open infrastructure, constituting a space where people, organizations, and technical components associate to develop an activity. The current infrastructure for medical image sharing, based on PACS/DICOM technologies, does not constitute an information infras...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00243-x

    authors: Motta GHMB,Araújo DAB,Lucena-Neto JR,Azevedo-Marques PM,Cordeiro SS,Araújo-Neto SA

    更新日期:2020-02-01 00:00:00

  • MRI Radiomics for the Prediction of Fuhrman Grade in Clear Cell Renal Cell Carcinoma: a Machine Learning Exploratory Study.

    abstract::The Fuhrman nuclear grade is a recognized prognostic factor for patients with clear cell renal cell carcinoma (CCRCC) and its pre-treatment evaluation significantly affects decision-making in terms of management. In this study, we aimed to assess the feasibility of a combined approach of radiomics and machine learning...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-020-00336-y

    authors: Stanzione A,Ricciardi C,Cuocolo R,Romeo V,Petrone J,Sarnataro M,Mainenti PP,Improta G,De Rosa F,Insabato L,Brunetti A,Maurea S

    更新日期:2020-08-01 00:00:00

  • Thresholding histogram equalization.

    abstract::The drawbacks of adaptive histogram equalization techniques are the loss of definition on the edges of the object and overenhancement of noise in the images. These drawbacks can be avoided if the noise is excluded in the equalization transformation function computation. A method has been developed to separate the hist...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-001-0103-z

    authors: Chuang KS,Chen S,Hwang IM

    更新日期:2001-12-01 00:00:00

  • Increasing the number of gray shades in medical display systems--how much is enough?

    abstract::Medical images produced by x-ray detectors, computed tomography (CT) scanners, and other modalities typically contain between 12-16 bits/pixel, which corresponds to 4,096-65,536 shades of gray. On the other hand, we see that these images are visualized by means of medical displays that have much lower available number...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-006-1052-3

    authors: Kimpe T,Tuytschaever T

    更新日期:2007-12-01 00:00:00

  • Computer-aided detection scheme for sentinel lymph nodes in lymphoscintigrams using symmetrical property around mapped injection point.

    abstract::It is difficult to detect sentinel lymph nodes (SLNs) around an injection point of radiopharmaceuticals mapped in lymphoscintigrams. The purpose of this study was to develop a computer-aided detection (CAD) scheme for SLNs by a subtraction technique using the symmetrical property in the mapped injection point. Our dat...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-011-9396-8

    authors: Nakayama R,Hizukuri A,Yamamoto K,Nakako N,Nagasawa N,Takeda K

    更新日期:2012-02-01 00:00:00

  • An Efficient Pipeline for Abdomen Segmentation in CT Images.

    abstract::Computed tomography (CT) scans usually include some disadvantages due to the nature of the imaging procedure, and these handicaps prevent accurate abdomen segmentation. Discontinuous abdomen edges, bed section of CT, patient information, closeness between the edges of the abdomen and CT, poor contrast, and a narrow hi...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-017-0032-0

    authors: Koyuncu H,Ceylan R,Sivri M,Erdogan H

    更新日期:2018-04-01 00:00:00

  • Estimates of Patient Radiation Doses in Digital Radiography Using DICOM Information at a Large Teaching Hospital in Oman.

    abstract::In this study, we sought to estimate the patient radiation doses in the digital radiography X-ray examinations conducted in a large hospital. The patient exposure factors and kerma-area product (PKA) were retrospectively recorded via the Digital Imaging and Communications in Medicine (DICOM) header for 547 patients. T...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-019-00199-y

    authors: Suliman II

    更新日期:2020-02-01 00:00:00

  • Application of temporal subtraction for detection of interval changes on chest radiographs: improvement of subtraction images using automated initial image matching.

    abstract::The authors developed a temporal subtraction scheme based on a nonlinear geometric warping technique to assist radiologists in the detection of interval changes in chest radiographs obtained on different occasions. The performance of the current temporal subtraction scheme is reasonably good; however, severe misregist...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/BF03168846

    authors: Ishida T,Ashizawa K,Engelmann R,Katsuragawa S,MacMahon H,Doi K

    更新日期:1999-05-01 00:00:00

  • Quantifying Analysis of Uncertainty in Medical Reporting: Creation of User and Context-Specific Uncertainty Profiles.

    abstract::While uncertainty is ubiquitous in medical practice, minimal work to date has been performed to analyze the cause and effect relationship between uncertainty and patient outcomes. In medical imaging practice, uncertainty in the radiology report has been well documented to be a source of clinician dissatisfaction. Befo...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章,评审

    doi:10.1007/s10278-018-0057-z

    authors: Reiner BI

    更新日期:2018-08-01 00:00:00

  • Freehand liver volumetry by using an electromagnetic pen tablet: accuracy, precision, and rapidity.

    abstract::The purpose of this study is to assess the accuracy, precision, and rapidity of liver volumes calculated by using a freehand electromagnetic pen tablet contourtracing method as compared with the volumes calculated by using the standard optical mouse contourtracing method. The imaging data used as input for accuracy an...

    journal_title:Journal of digital imaging

    pub_type: 杂志文章

    doi:10.1007/s10278-010-9291-8

    authors: Perandini S,Faccioli N,Inama M,Pozzi Mucelli R

    更新日期:2011-04-01 00:00:00