Abstract:
:Sedation in locations outside the operating room (OR) is common. Guidelines for safe patient monitoring have been updated by the American Society of Anesthesiology to include monitoring of ventilation and/or carbon dioxide (CO2). Although technologies exist to monitor these variables, the quality and/or availability of these measurements in non-OR settings is not optimal. This quality improvement project assessed the value of impedance technology for monitoring minute ventilation (MV) compared to standard end-tidal monitoring of CO2 (ETCO2). Patients undergoing GI exams with moderate sedation provided by anesthesia providers were monitored for MV with a respiratory volume monitor (ExSpiron 1Xi, Respiratory Motion, Waltham, MA) and ETCO2 via nasal cannula (NC). Calibration and baseline data were collected prior to sedation. Continuous MV and ETCO2 data were collected and averaged, providing minute values after sedation medications throughout the procedure. Stable periods of reduced MV were averaged and used in comparison to ETCO2. Data from 20 patients were evaluated. After sedation, the expected decrease in MV after sedation was observed in 18 of 20 patients (average -47.82 %), while an increase in ETCO2 was observed in just 10 of 20 patients (average -5.17 mm Hg). The correlation coefficient between changes in MV and ETCO2 in response to sedation administration was positive and not significant, r = 0.223. Ventilation monitoring may provide an element of safety for earlier and more reliable detection of reduced ventilation compared to a surrogate for hypoventilation, ETCO2, in patients undergoing sedation for GI procedures outside of the OR.
journal_name
J Clin Monit Computjournal_title
Journal of clinical monitoring and computingauthors
Ebert TJ,Middleton AH,Makhija Ndoi
10.1007/s10877-015-9809-1subject
Has Abstractpub_date
2017-02-01 00:00:00pages
53-57issue
1eissn
1387-1307issn
1573-2614pii
10.1007/s10877-015-9809-1journal_volume
31pub_type
杂志文章abstract::Monitors evaluating the electroencephalogram (EEG) to determine depth of anaesthesia use spectral analysis approaches for analysis windows up to 61.5 s as well as additional smoothing algorithms. Stationary EEG is required to reliably apply the index algorithms. Because of rapid physiological changes, artefacts, etc.,...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章,随机对照试验
doi:10.1007/s10877-014-9553-y
更新日期:2014-12-01 00:00:00
abstract::Mathematical models can be deployed to simulate physiological processes of the human organism. Exploiting these simulations, reactions of a patient to changes in the therapy regime can be predicted. Based on these predictions, medical decision support systems (MDSS) can help in optimizing medical therapy. An MDSS desi...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-013-9502-1
更新日期:2014-12-01 00:00:00
abstract::Jaundice of the newborn is a common problem as a consequence of the rapid increment of blood bilirubin in the first days of live. In most cases, it is considered a physiological transient situation, but unmanaged hyperbilirubinemia can lead to death or serious injuries for the survivors. For decades, phototherapy has ...
journal_title:Journal of clinical monitoring and computing
pub_type: 临床试验,杂志文章
doi:10.1007/s10877-006-9016-1
更新日期:2006-06-01 00:00:00
abstract::Heart failure is the main cause of poor outcome following open heart surgery and experimental studies have demonstrated that glucose-insulin-potassium (GIK) infusion exerts cardioprotective effects by reducing myocardial ischemia-reperfusion injuries. This randomized controlled trial was designed to assess the effects...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-019-00280-5
更新日期:2020-02-01 00:00:00
abstract::While the effects of phenylephrine (PE) and ephedrine (E) on cerebral oxygen saturation (rScO2) already has been studied, the effect on paraspinal oxygen saturation (rSpsO2) is still unexplored. This study aims to assess the effect of PE and E on rScO2 and rSpsO2, measured with near-infrared spectroscopy. A randomized...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-019-00328-6
更新日期:2020-04-01 00:00:00
abstract:OBJECTIVES:To determine if wavelet analysis techniques can be used to reliably identify individual breaths from the photoplethysmogram (PPG). METHODS:Photoplethysmograms were obtained from 22 healthy adult volunteers timing their respiration rate in synchronisation with a metronome. A secondary timing signal was obtai...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-005-2697-z
更新日期:2004-12-01 00:00:00
abstract::Changes in expired nitric oxide (NO) occur in airway inflammation and have proved to be important in the monitoring of inflammatory disease processes such as asthma. We set out to develop a novel hand-held NO-analyzer with a performance comparable to the present more costly and complex chemiluminescence instruments. T...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-005-1158-z
更新日期:2004-12-01 00:00:00
abstract::Recent advances in technology have led to the introduction of a variety of innovative devices, each with their own platform for data display, into the operating room (OR). While these innovative applications are expanding the traditional boundaries of the surgical space and enhancing treatment capabilities, the introd...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-006-9017-0
更新日期:2006-06-01 00:00:00
abstract:OBJECTIVE:Artefact detection is an essential feature of automatic EEG monitoring systems used in anaesthesia. Clinical experience indicates that Narcotrend monitoring (MonitorTechnik, Bad Bramstedt, Germany, version 4.0) excludes more EEG epochs because of artefacts than bispectral index monitoring (BIS, Aspect Medical...
journal_title:Journal of clinical monitoring and computing
pub_type: 临床试验,杂志文章
doi:10.1007/s10877-005-2700-8
更新日期:2004-08-01 00:00:00
abstract:OBJECTIVE:The present paper introduces a new perspective on the classical ensemble averaging which can be useful to analyse the Brainstem Auditory Evoked Potentials (BAEPs). The analysis of the dynamics, related to the BAEP, is performed directly after its acquisition from the electroencephalogram (EEG). METHODS:The m...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1023/b:jocm.0000042919.04719.a7
更新日期:2004-06-01 00:00:00
abstract:STUDY OBJECTIVES:Electrical impedance tomography (EIT) is able to reflect physiological parameters such as real-time changes in global and regional lung volume. EIT can aid in the assessment of lung recruitment, and its use has been validated in preliminary studies monitoring mechanical ventilation at the bedside. ICU ...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-006-9021-4
更新日期:2006-06-01 00:00:00
abstract:OBJECTIVE:To compare expert-generated textual summaries of physiological data with trend graphs, in terms of their ability to support neonatal Intensive Care Unit (ICU) staff in making decisions when presented with medical scenarios. METHODS:Forty neonatal ICU staff were recruited for the experiment, eight from each o...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-005-0879-3
更新日期:2005-06-01 00:00:00
abstract::Audible pulse tones, based on a variable-pitch frequency scale, allow the anesthesiologist to determine the patient's oxygen saturation without constant visual examination of the monitor display. The ability to reliably detect oxygen saturation levels based on audible pulse tones may be compromised when multiple pulse...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1023/b:jocm.0000032698.47717.06
更新日期:2004-04-01 00:00:00
abstract::Uncalibrated arterial waveform analysis enables dynamic preload assessment in a minimally invasive fashion. Evidence about the validity of the technique in patients with impaired left ventricular function is scarce, while adequate cardiac preload assessment would be of great value in these patients. The aim of this st...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-015-9743-2
更新日期:2016-08-01 00:00:00
abstract::Ultrasound scanning of bladder volume is used for prevention of postoperative urinary retention (POUR). Accurate assessment of bladder volume is needed to allow clinical decision-making regarding the need for postoperative catheterization. Two commonly used ultrasound devices, the BladderScan® BVI 9400 and the newly r...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-018-0123-6
更新日期:2018-12-01 00:00:00
abstract::This prospective study evaluates haemodynamic and electroencephalographic effects observed when administering four combinations of effect-site concentrations of propofol (CePROP) and remifentanil (CeREMI), all yielding a single predicted probability of tolerance of laryngoscopy of 90% (PTOL = 90%) according to the Bou...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-020-00540-9
更新日期:2020-06-03 00:00:00
abstract::Near-infrared spectrophotometry assesses cerebral oxygen saturation (ScO2) based on the absorption spectra of oxygenated and deoxygenated hemoglobin, and the translucency of biological tissue, in the near-infrared band. There is increasing evidence that optimising cerebral oxygenation, guided by ScO2, is associated wi...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-014-9642-y
更新日期:2015-10-01 00:00:00
abstract::We tested whether the ratio of alveolar dead space to alveolar tidal volume (VD(alv)/VT(alv)) can detect states of low pulmonary blood flow (PBF) in a non-invasive way. Fifteen patients undergoing cardiovascular surgeries with cardiopulmonary bypass (CPB) were studied. CPB is a technique that excludes the lungs from t...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-012-9358-9
更新日期:2012-06-01 00:00:00
abstract::Excessive pressures exerted on the tongue during intubation may be associated with serious complications and may make intubation more difficult. The aim of this study was to evaluate five different intubating devices in the hands of experienced anaesthetists during simulated conditions of reduced cervical spine mobili...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-017-0095-y
更新日期:2018-10-01 00:00:00
abstract::The physiology underlying the intracranial pressure (ICP) curve morphology is not fully understood. Recent research has suggested that the morphology could be dependent on arterial cerebral inflow and the physiological and pathophysiological properties of the intracranial cavity. If understood, the ICP curve could pro...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-019-00342-8
更新日期:2020-06-01 00:00:00
abstract::The eye lens is one of the most sensitive organs for radiation injury and exposure might lead to radiation induced cataract. Eye lens dosimetry in anesthesiology has been published in few clinical trials and an active debate about the causality of radiation induced cataract is still ongoing. Recently, the Internationa...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-016-9857-1
更新日期:2017-04-01 00:00:00
abstract::The quantity of blood arriving at the left side of the heart oscillates throughout the breathing cycle due to the mechanics of breathing. Neurally regulated fluctuations in the length of the heart period act to dampen oscillations of the left ventricular stroke volume entering the aorta. We have reported that stroke v...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-011-9327-8
更新日期:2012-02-01 00:00:00
abstract::It remains to be discovered whether a formula predicting the subglottic transverse diameter measured by ultrasound (SGDformula) for the selection of an appropriate endotracheal tube (ETT) for children without congenital heart disease (CHD) is useful for children with CHD. A formula for predicting SGD was established a...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-018-0203-7
更新日期:2019-08-01 00:00:00
abstract::Arterial stiffness is a reliable prognostic parameter for cardiovascular diseases. The effect of change in arterial stiffness can be measured by the change of the pulse wave velocity (PWV). The Complior system is widely used to measure PWV between the carotid and radial arteries by means of piezoelectric clips placed ...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-018-0165-9
更新日期:2019-04-01 00:00:00
abstract::The use of processed electroencephalography (EEG) using a simple frontal lead system has been made available for assessing the impact of anesthetic medications during surgery. This review discusses the basic principles behind these devices. The foundations of anesthesia monitoring rest on the observations of Guedel wi...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章,评审
doi:10.1007/s10877-006-9044-x
更新日期:2006-12-01 00:00:00
abstract::Recent progress in genomics and experimental biology has brought exponential growth of the biological information available for computational analysis in public genomics databases. However, applying the potentially enormous scientific value of this information to the understanding of biological systems requires comput...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-005-3463-y
更新日期:2005-10-01 00:00:00
abstract::Cigarette smoking is often associated with the development of several respiratory diseases however, if diagnosed early, the changes in the lung tissue caused by smoking may be reversible. Computerised respiratory sounds have shown to be sensitive to detect changes within the lung tissue before any other measure, howev...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-016-9887-8
更新日期:2017-06-01 00:00:00
abstract::Recent advance in imaging modalities used frequently in clinical routine can provide description of the geometrical and hemodynamical properties of the arterial tree in great detail. The combination of such information with models of blood flow of the arterial tree can provide further information, such as details in p...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章,评审
doi:10.1007/s10877-012-9382-9
更新日期:2012-10-01 00:00:00
abstract::Jasiukaitis and Lyon (J Clin Monit Comput, https://doi.org/10.1007/s10877-018-0181-9, 2018) described an motor evoked potential (MEP)amplitude trending system to detect MEP amplitude loss against a background of MEP variability. They found that the end of case value of a running R2 triggered by a set MEP amplitude los...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-019-00272-5
更新日期:2020-02-01 00:00:00
abstract::The operating principles and methods for the continuous determination of aortic blood flow (ABF) with the Dynemo 3000 system are described in detail. The system uses a novel transesophageal ultrasonic Echo-Doppler probe simultaneously to measure aortic diameter and blood flow velocity at the same anatomic level, in re...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1023/a:1009902517388
更新日期:2000-01-01 00:00:00