Non-invasive cardiac output monitoring by aortic blood flow measurement with the Dynemo 3000.

Abstract:

:The operating principles and methods for the continuous determination of aortic blood flow (ABF) with the Dynemo 3000 system are described in detail. The system uses a novel transesophageal ultrasonic Echo-Doppler probe simultaneously to measure aortic diameter and blood flow velocity at the same anatomic level, in real-time. Non-invasive ABF measurement is combined with vital sign data from standard monitors to provide a composite hemodynamic profile including volume, afterload and contractility data used by the physician to optimize therapy. A review of the clinical validation and comparison to thermodilution measurements showing a significant positive correlation over a wide range of clinical flow situations is also briefly presented.

journal_name

J Clin Monit Comput

authors

Boulnois JL,Pechoux T

doi

10.1023/a:1009902517388

subject

Has Abstract

pub_date

2000-01-01 00:00:00

pages

127-40

issue

2

eissn

1387-1307

issn

1573-2614

journal_volume

16

pub_type

杂志文章
  • Observational study of newborn infant parasympathetic evaluation as a comfort system in awake patients admitted to a pediatric intensive care unit.

    abstract::To compare the newborn infant parasympathetic evaluation system (NIPE) scores with a validated clinical scale using two different nebulizers in children with bronchiolitis admitted to a PICU. Comfort was evaluated using the COMFORT-behavior scale (CBS) before (T1), during (T2) and after (T3) each nebulization. In orde...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10877-019-00268-1

    authors: Valencia-Ramos J,Arnaez J,Calvo S,Gomez F,Del Blanco I

    更新日期:2019-10-01 00:00:00

  • Computerised respiratory sounds can differentiate smokers and non-smokers.

    abstract::Cigarette smoking is often associated with the development of several respiratory diseases however, if diagnosed early, the changes in the lung tissue caused by smoking may be reversible. Computerised respiratory sounds have shown to be sensitive to detect changes within the lung tissue before any other measure, howev...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-016-9887-8

    authors: Oliveira A,Sen I,Kahya YP,Afreixo V,Marques A

    更新日期:2017-06-01 00:00:00

  • Comparison of cardiac output optimization with an automated closed-loop goal-directed fluid therapy versus non standardized manual fluid administration during elective abdominal surgery: first prospective randomized controlled trial.

    abstract::An intraoperative automated closed-loop system for goal-directed fluid therapy has been successfully tested in silico, in vivo and in a clinical case-control matching. This trial compared intraoperative cardiac output (CO) in patients managed with this closed-loop system versus usual practice in an academic medical ce...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10877-018-0106-7

    authors: Lilot M,Bellon A,Gueugnon M,Laplace MC,Baffeleuf B,Hacquard P,Barthomeuf F,Parent C,Tran T,Soubirou JL,Robinson P,Bouvet L,Vassal O,Lehot JJ,Piriou V

    更新日期:2018-12-01 00:00:00

  • Evaluation of a computerized system for mechanical ventilation of infants.

    abstract:OBJECTIVE:To evaluate a computerized system for mechanical ventilation of infants. METHODS:FLEX is a computerized system that includes the features of a patented mode known as adaptive-support ventilation (ASV). In addition, it has many other features including adjustment of positive end-expiratory pressure (PEEP), fr...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-009-9170-3

    authors: Tehrani FT,Abbasi S

    更新日期:2009-04-01 00:00:00

  • Comparison of an ultrasound-guided technique versus a landmark-guided technique for internal jugular vein cannulation.

    abstract::Central venous cannulation is a commonly preformed procedure in many branches of medicine, particularly in anaesthesia and intensive care medicine. The purpose of this study was to compare the landmark-guided technique to the ultrasound-guided technique for internal jugular vein cannulation in cardiovascular surgery p...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10877-014-9585-3

    authors: Dolu H,Goksu S,Sahin L,Ozen O,Eken L

    更新日期:2015-02-01 00:00:00

  • Predictive data mining on monitoring data from the intensive care unit.

    abstract::The widespread implementation of computerized medical files in intensive care units (ICUs) over recent years has made available large databases of clinical data for the purpose of developing clinical prediction models. The typical intensive care unit has several information sources from which data is electronically co...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-012-9416-3

    authors: Güiza F,Van Eyck J,Meyfroidt G

    更新日期:2013-08-01 00:00:00

  • Electrical impedance tomography's correlation to lung volume is not influenced by anthropometric parameters.

    abstract:STUDY OBJECTIVES:Electrical impedance tomography (EIT) is able to reflect physiological parameters such as real-time changes in global and regional lung volume. EIT can aid in the assessment of lung recruitment, and its use has been validated in preliminary studies monitoring mechanical ventilation at the bedside. ICU ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-006-9021-4

    authors: Marquis F,Coulombe N,Costa R,Gagnon H,Guardo R,Skrobik Y

    更新日期:2006-06-01 00:00:00

  • Simulating physiological interactions in a hybrid system of mathematical models.

    abstract::Mathematical models can be deployed to simulate physiological processes of the human organism. Exploiting these simulations, reactions of a patient to changes in the therapy regime can be predicted. Based on these predictions, medical decision support systems (MDSS) can help in optimizing medical therapy. An MDSS desi...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-013-9502-1

    authors: Kretschmer J,Haunsberger T,Drost E,Koch E,Möller K

    更新日期:2014-12-01 00:00:00

  • A comparison of ventricular systolic function indices provided by VolumeView/EV1000™ and left ventricular ejection fraction by echocardiography among septic shock patients.

    abstract::The aim of this study was to compare the cardiac function index (CFI) and global ejection fraction (GEF) obtained by VolumeView/EV1000™, with the left ventricular ejection fraction (LVEF) by echocardiography in septic shock patients. A prospective observational study was conducted in a medical intensive care unit of a...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-018-0152-1

    authors: Nakwan N,Chichareon P,Khwannimit B

    更新日期:2019-04-01 00:00:00

  • Journal of Clinical Monitoring and Computing 2019 end of year summary: monitoring tissue oxygenation and perfusion and its autoregulation.

    abstract::Tissue perfusion monitoring is increasingly being employed clinically in a non-invasive fashion. In this end-of-year summary of the Journal of Clinical Monitoring and Computing, we take a closer look at the papers published recently on this subject in the journal. Most of these papers focus on monitoring cerebral perf...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,评审

    doi:10.1007/s10877-020-00504-z

    authors: Sahinovic MM,Vos JJ,Scheeren TWL

    更新日期:2020-06-01 00:00:00

  • Comparison between two mathematical methods to estimate arterial occlusion pressure and tourniquet effectiveness in lower limb surgery: a prospective, randomized, double blind, comparative study.

    abstract::The effectiveness of two different methods for calculating the arterial occlusion pressure (AOP) to set tourniquet inflation pressures were assessed in patients underwent knee arthroscopy. Eighty patients were included in this study. Tourniquet inflation pressure was set by adding 20 mmHg of safety margin above the AO...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00366-0

    authors: Kasem SA,Al Menesy T,Badawy AA,Abd Elmawgoud A,Adel G,Badawy YA

    更新日期:2020-08-01 00:00:00

  • Continuous hemoglobin and plethysmography variability index monitoring can modify blood transfusion practice and is associated with lower mortality.

    abstract::To determine the effect of implementing an algorithm of fluid and blood administration based on continuous monitoring of hemoglobin (SpHb) and PVI (plethysmography variability index) on mortality and transfusion on a whole hospital scale. This single-center quality program compared transfusion at 48 h and mortality at...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00367-z

    authors: Cros J,Dalmay F,Yonnet S,Charpentier M,Tran-Van-Ho J,Renaudeau F,Drouet A,Guilbaut P,Marin B,Nathan N

    更新日期:2020-08-01 00:00:00

  • The pressure exerted on the tongue during intubation with simultaneous cervical spine immobilisation: a comparison between four videolaryngoscopes and the Macintosh laryngoscope-a manikin study.

    abstract::Excessive pressures exerted on the tongue during intubation may be associated with serious complications and may make intubation more difficult. The aim of this study was to evaluate five different intubating devices in the hands of experienced anaesthetists during simulated conditions of reduced cervical spine mobili...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-017-0095-y

    authors: Aleksandrowicz D,Gaszyński T

    更新日期:2018-10-01 00:00:00

  • Heart rate variability analysis during central hypovolemia using wavelet transformation.

    abstract::Detection of hypovolemia prior to overt hemodynamic decompensation remains an elusive goal in the treatment of critically injured patients in both civilian and combat settings. Monitoring of heart rate variability has been advocated as a potential means to monitor the rapid changes in the physiological state of hemorr...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-013-9434-9

    authors: Ji SY,Belle A,Ward KR,Ryan KL,Rickards CA,Convertino VA,Najarian K

    更新日期:2013-06-01 00:00:00

  • Non-invasive electrical cardiometry cardiac output monitoring during prehospital helicopter emergency medical care: a feasibility study.

    abstract:PURPOSE:Introducing advanced hemodynamic monitoring might be beneficial during Helicopter Emergency Medical Service (HEMS) care. However, it should not increase the on-scene-time, it should be easy to use and should be non-invasive. The goal of this study was to investigate the feasibility of non-invasive cardiac outpu...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-021-00657-5

    authors: Slagt C,Servaas S,Ketelaars R,van Geffen GJ,Tacken MCT,Verrips CA,Baggen LAM,Scheffer GJ,van Eijk LT

    更新日期:2021-01-23 00:00:00

  • Detection of intratracheal accumulation of thick secretions by using continuous monitoring of respiratory acoustic spectrum: a preliminary analysis.

    abstract::The accumulation of tracheobronchial secretions may contribute to a deterioration in pulmonary function and its early detection is important. In this study, we analyzed the respiratory sound spectrum in patients with intratracheal secretion, and compared acoustic characteristics before and after therapeutic endotrache...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00359-z

    authors: Moon YJ,Bechtel AJ,Kim SH,Kim JW,Thiele RH,Blank RS

    更新日期:2020-08-01 00:00:00

  • Assessment of the 50 % and 95 % effective paratracheal forces for occluding the esophagus in anesthetized patients.

    abstract::This study aimed to evaluate the 50% and 95% effective paratracheal forces for occluding the esophagus in anesthetized patients. In 46 anesthetized patients, the upper esophagus was examined using ultrasonography, and the lower paratracheal area over the esophagus just above the clavicle was marked. Manual paratrachea...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-021-00652-w

    authors: Kim H,Mondal S,Choi CG,Hwang JY

    更新日期:2021-01-26 00:00:00

  • Computerized recording of neuromuscular monitoring and the risk of residual paralysis at the time of extubation.

    abstract:OBJECTIVE:We tested whether a newly installed neuromuscular monitoring device (NMT) with a computerized anesthesia recording system, incorporated in all anesthesia stations, could enhance the commitment to objective neuromuscular monitoring in a teaching hospital anesthesia department. METHODS:After 6 months of famili...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-008-9135-y

    authors: Motamed C,Bourgain JL

    更新日期:2008-08-01 00:00:00

  • Cardioplegia and ventricular late potentials in cardiac surgical patients.

    abstract:BACKGROUND AND OBJECTIVE:Ventricular late potentials (LP) recording with signal-averaged electrocar- diogram allow identifying patients at risk of sudden death and ventricular tachycardia. Cardiac surgery with cardiopulmonary bypass (CPB) could predispose to the development of myocardial ischemia related to imperfect c...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-011-9305-1

    authors: Schütz N,Romand JA,Yanez ND,Treggiari MM,Bendjelid K

    更新日期:2011-08-01 00:00:00

  • The American Society of Neurophysiological Monitoring position statements project.

    abstract::The American Society of Neurophysiological Monitoring (ASNM) is developing position statements aimed at assisting practitioners and others in making decisions regarding neurophysiological monitoring practice. This paper describes the procedures used in drafting these documents. ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-005-9000-1

    authors: Morledge DE,Stecker M

    更新日期:2006-02-01 00:00:00

  • A comparison of graphical and textual presentations of time series data to support medical decision making in the neonatal intensive care unit.

    abstract:OBJECTIVE:To compare expert-generated textual summaries of physiological data with trend graphs, in terms of their ability to support neonatal Intensive Care Unit (ICU) staff in making decisions when presented with medical scenarios. METHODS:Forty neonatal ICU staff were recruited for the experiment, eight from each o...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-005-0879-3

    authors: Law AS,Freer Y,Hunter J,Logie RH,McIntosh N,Quinn J

    更新日期:2005-06-01 00:00:00

  • Performance of a capnodynamic method estimating effective pulmonary blood flow during transient and sustained hypercapnia.

    abstract::The capnodynamic method is a minimally invasive method continuously calculating effective pulmonary blood flow (COEPBF), equivalent to cardiac output when intra pulmonary shunt flow is low. The capnodynamic equation joined with a ventilator pattern containing cyclic reoccurring expiratory holds, provides breath to bre...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-017-0021-3

    authors: Sigmundsson TS,Öhman T,Hallbäck M,Redondo E,Sipmann FS,Wallin M,Oldner A,Hällsjö Sander C,Björne H

    更新日期:2018-04-01 00:00:00

  • Machine learning applied to multi-sensor information to reduce false alarm rate in the ICU.

    abstract::Studies reveal that the false alarm rate (FAR) demonstrated by intensive care unit (ICU) vital signs monitors ranges from 0.72 to 0.99. We applied machine learning (ML) to ICU multi-sensor information to imitate a medical specialist in diagnosing patient condition. We hypothesized that applying this data-driven approa...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00307-x

    authors: Hever G,Cohen L,O'Connor MF,Matot I,Lerner B,Bitan Y

    更新日期:2020-04-01 00:00:00

  • Right ventricular function in late-onset Pompe disease.

    abstract::Pompe's disease is a glycogen storage disease (type II) characterized by inherited autosomal recessive transmission. The right ventricular (RV) function is a determinant parameter of clinical outcome in patients with heart failure. We sought to characterize the RV function using Doppler-echocardiography completed by D...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-014-9551-0

    authors: Fayssoil A,Nardi O,Annane D,Orlikowski D

    更新日期:2014-08-01 00:00:00

  • Estimation of pulse pressure variation and cardiac output in patients having major abdominal surgery: a comparison between a mobile application for snapshot pulse wave analysis and invasive pulse wave analysis.

    abstract::Pulse pressure variation (PPV) and cardiac output (CO) can guide perioperative fluid management. Capstesia (Galenic App, Vitoria-Gasteiz, Spain) is a mobile application for snapshot pulse wave analysis (PWAsnap) and estimates PPV and CO using pulse wave analysis of a snapshot of the arterial blood pressure waveform di...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00572-1

    authors: Hoppe P,Gleibs F,Briesenick L,Joosten A,Saugel B

    更新日期:2020-08-04 00:00:00

  • Comparison of cardiac output determined by bioimpedance and bioreactance methods at rest and during exercise.

    abstract::Bioreactance is a novel non-invasive method for cardiac output measurement that involves the analysis of blood flow-dependent changes in the phase shifts of electrical currents applied across the chest. The present study (1) compared resting and exercise cardiac outputs determined by bioreactance and bioimpedance meth...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-012-9334-4

    authors: Jakovljevic DG,Moore S,Hallsworth K,Fattakhova G,Thoma C,Trenell MI

    更新日期:2012-04-01 00:00:00

  • Changes in cerebral and renal oxygenation during laparoscopic pyloromyotomy.

    abstract::Although a laparoscopic approach may be preferred over open procedures for abdominal surgery, there are limited data on the effect of laparoscopic procedures on cerebral and renal oxygenation in neonates and young infants. Here, we evaluated the effect in neonates and infants. In this two-center prospective observatio...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00356-2

    authors: Kamata M,Hakim M,Walia H,Tumin D,Tobias JD

    更新日期:2020-08-01 00:00:00

  • Validation of a photoplethysmography device for detection of obstructive sleep apnea in the perioperative setting.

    abstract::Obstructive sleep apnea (OSA) is a risk factor for perioperative complications, but many OSA patients present undiagnosed. While polysomnography (PSG) is the "gold standard" for diagnosis, its application is technology-intense, time-consuming, expensive, and requires specialists, often delaying surgery. Thus, miniatur...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-018-0151-2

    authors: Faßbender P,Haddad A,Bürgener S,Peters J

    更新日期:2019-04-01 00:00:00

  • Evaluating the efficiency of desflurane reflection in two commercially available reflectors.

    abstract::With the AnaConDa™ and the MIRUS™ system, volatile anesthetics can be administered for inhalation sedation in intensive care units. Instead of a circle system, both devices use anesthetic reflectors to save on the anesthetic agent. We studied the efficiency of desflurane reflection with both devices using different ti...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-016-9902-0

    authors: Bomberg H,Wessendorf M,Bellgardt M,Veddeler M,Wagenpfeil S,Volk T,Groesdonk HV,Meiser A

    更新日期:2018-08-01 00:00:00

  • Assessment of the benefits of head-up preoxygenation using near-infrared spectroscopy with pulse oximetry in a swine model.

    abstract::Compared with supine positioning, head-up positioning improves preoxygenation and prolongs the time to oxygen desaturation. We reevaluated benefits of head-up positioning using near-infrared spectroscopy (NIRS) with pulse oximetry in a pig model. Six pigs (mean ± SD weight: 25.3 ± 0.6 kg) were anesthetized with isoflu...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00456-z

    authors: Kurita T,Kawashima S,Morita K,Nakajima Y

    更新日期:2020-01-02 00:00:00