Right ventricular function in late-onset Pompe disease.

Abstract:

:Pompe's disease is a glycogen storage disease (type II) characterized by inherited autosomal recessive transmission. The right ventricular (RV) function is a determinant parameter of clinical outcome in patients with heart failure. We sought to characterize the RV function using Doppler-echocardiography completed by Doppler tissular imaging and tricuspid annular plane systolic excursion (TAPSE) measurement. We analyzed retrospectively clinical and Doppler-echocardiographic data of patients with adult late onset Pompe disease and compared to a control group. Ten patients with late onset Pompe disease were included in our study and were compared to a control group (seven patients). Mean age was 56.7 ± 10.2 years in late onset Pompe disease versus 55 ± 21 years in control group (p  = 0.65). Left ventricular ejection fraction (LVEF) was similar in the two groups (LVEF 63.7 ± 9 vs 63.7 ± 6.6 % in control group p  = 0.99). LV end diastolic diameter was 40.8 ± 6 mm in Pompe disease versus 45.8 ± 6 mm in control group (p  = 0.11). Mean TAPSE was similar in the two groups (25.6 ± 6.2 vs 21.5 ± 2.7 mm p = 0.23). Mean peak systolic RV velocity Sm was not significantly different in the two groups (17.11 ± 3.4 cm/s in Pompe disease vs 16.14 ± 3.8 cm/s in control group p = 0.61). Mean peak early diastolic Ea velocity in the RV were not significantly different in the two groups (15.6 ± 5.6 vs 18.2 ± 4.9 cm/s p = 0.34). According to our data, RV systolic function seems preserved in late-onset Pompe disease.

journal_name

J Clin Monit Comput

authors

Fayssoil A,Nardi O,Annane D,Orlikowski D

doi

10.1007/s10877-014-9551-0

subject

Has Abstract

pub_date

2014-08-01 00:00:00

pages

419-21

issue

4

eissn

1387-1307

issn

1573-2614

journal_volume

28

pub_type

杂志文章
  • Are automated blood pressure monitors accurate enough to calculate the ankle brachial pressure index?

    abstract:OBJECTIVE:Conventional sphygmomanometers are being replaced by automated devices; can they be used to accurately calculate ABPI? METHOD:Thirty-six volunteers (72 legs) attending a vascular clinic had their ankle, brachial blood pressure and ABPIs calculated using each of these 3 methods. (1) Conventional aneuroid BP c...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-008-9146-8

    authors: MacDonald E,Froggatt P,Lawrence G,Blair S

    更新日期:2008-10-01 00:00:00

  • Ventilator-associated pneumonia: current status and future recommendations.

    abstract:OBJECTIVE:Ventilator-associated pneumonia (VAP) is a common hazardous complication in ICU patients. The aim of the current review is to give an update on the current status and future recommendations for VAP prevention. METHODS:This article gives an updated review of the current literature on VAP. The first part brief...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,meta分析,评审

    doi:10.1007/s10877-010-9228-2

    authors: Efrati S,Deutsch I,Antonelli M,Hockey PM,Rozenblum R,Gurman GM

    更新日期:2010-04-01 00:00:00

  • Correlation between preoperative somatosensory evoked potentials and intraoperative neurophysiological monitoring in spinal cord tumors.

    abstract::Intraoperative neurophysiological monitoring (IONM) is widely used in spinal cord tumors (SCTs) removal surgery. This study mainly hypothesized that patients with prolonged latency of preoperative somatosensory evoked potentials (preSEPLat) would have more deteriorated intraoperative evoked potentials. Among 506 patie...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00584-x

    authors: Park J,Cho YE,Park M,Lee J,Kim D,Park YG

    更新日期:2020-09-29 00:00:00

  • Continuous glucose monitoring system in the operating room and intensive care unit: any difference according to measurement sites?

    abstract::Given the benefit of glucose control in the perioperative period, we evaluated the accuracy and performance of the continuous glucose monitoring system (CGMS) depending on different measurement sites in the operating room (OR) and in the intensive care unit (ICU). Patients over 18 years of age scheduled for elective s...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-015-9804-6

    authors: Song IK,Lee JH,Kang JE,Park YH,Kim HS,Kim JT

    更新日期:2017-02-01 00:00:00

  • A mathematical model for predicting intracranial pressure based on noninvasively acquired PC-MRI parameters in communicating hydrocephalus.

    abstract::To develop and validate a mathematical model for predicting intracranial pressure (ICP) noninvasively using phase-contrast cine MRI (PC-MRI). We performed a retrospective analysis of PC-MRI from patients with communicating hydrocephalus (n = 138). The patients were recruited from Shenzhen Second People's Hospital betw...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00598-5

    authors: Long J,Sun D,Zhou X,Huang X,Hu J,Xia J,Yang G

    更新日期:2020-10-01 00:00:00

  • Trans-ocular brain impedance index for assessment of cerebral autoregulation in a porcine model of cerebral hemodynamic perturbation.

    abstract::Cerebrovascular autoregulation (CA) is often impaired following traumatic brain injury. Established technologies and metrics used to assess CA are invasive and conducive for measurement, but not for continuous monitoring. We developed a trans-ocular brain impedance (TOBI) method that may provide non-invasive and conti...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00556-1

    authors: Tiba MH,McCracken BM,Leander DC,Colmenero CI,Cummings BC,Greer NL,Picton P,Williamson CA,Ward KR

    更新日期:2020-07-14 00:00:00

  • Surrogate indices of aortic peak systolic velocity variation to monitor fluid responsiveness in pediatric non-cardiac surgery: a prospective observational study.

    abstract::Aortic peak systolic velocity variation (ΔVpeakAo) is a reliable dynamic indicator of preload in mechanically ventilated children. However, easily measurable alternative parameters like carotid peak systolic velocity variation (ΔVpeakCa) and suprasternal peak systolic velocity variation (ΔVpeakSs) are not well evaluat...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00431-8

    authors: Niyogi SG,Sen IM,Jayant A,Mandal B,Bhardwaj N,Yaddanapudi S,Mathew P

    更新日期:2020-12-01 00:00:00

  • Using physiological models and decision theory for selecting appropriate ventilator settings.

    abstract:OBJECTIVE:To present a decision support system for optimising mechanical ventilation in patients residing in the intensive care unit. METHODS:Mathematical models of oxygen transport, carbon dioxide transport and lung mechanics are combined with penalty functions describing clinical preference toward the goals and side...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-006-9049-5

    authors: Rees SE,Allerød C,Murley D,Zhao Y,Smith BW,Kjaergaard S,Thorgaard P,Andreassen S

    更新日期:2006-12-01 00:00:00

  • Leakage of sevoflurane from vaporizer detected by air monitoring system: a case report.

    abstract::Leakage of inhalational anesthetic gases is an important issue not only to staff health but awareness during general anesthesia. After inhalation of sevoflurane commenced, the audible and visible alarm of our custom-made air monitoring system was activated. The system measured 2-4 ppm of sevoflurane. A thorough search...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-013-9479-9

    authors: Tanaka M,Yamaura K,Higashi M,Hoka S

    更新日期:2013-12-01 00:00:00

  • Importance of re-calibration time on pulse contour analysis agreement with thermodilution measurements of cardiac output: a retrospective analysis of intensive care unit patients.

    abstract::We assessed the effect of re-calibration time on cardiac output estimation and trending performance in a retrospective analysis of an intensive care unit patient population using error grid analyses. Paired thermodilution and arterial blood pressure waveform measurements (N = 2141) from 222 patient records were extrac...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-015-9749-9

    authors: Scully CG,Gomatam S,Forrest S,Strauss DG

    更新日期:2016-10-01 00:00:00

  • The evolution of eProtocols that enable reproducible clinical research and care methods.

    abstract::Unnecessary variation in clinical care and clinical research reduces our ability to determine what healthcare interventions are effective. Reducing this unnecessary variation could lead to further healthcare quality improvement and more effective clinical research. We have developed and used electronic decision suppor...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-012-9356-y

    authors: Blagev DP,Hirshberg EL,Sward K,Thompson BT,Brower R,Truwit J,Hite D,Steingrub J,Orme JF Jr,Clemmer TP,Weaver LK,Thomas F,Grissom CK,Sorenson D,Sittig DF,Wallace CJ,East TD,Warner HR,Morris AH

    更新日期:2012-08-01 00:00:00

  • Performance of a capnodynamic method estimating effective pulmonary blood flow during transient and sustained hypercapnia.

    abstract::The capnodynamic method is a minimally invasive method continuously calculating effective pulmonary blood flow (COEPBF), equivalent to cardiac output when intra pulmonary shunt flow is low. The capnodynamic equation joined with a ventilator pattern containing cyclic reoccurring expiratory holds, provides breath to bre...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-017-0021-3

    authors: Sigmundsson TS,Öhman T,Hallbäck M,Redondo E,Sipmann FS,Wallin M,Oldner A,Hällsjö Sander C,Björne H

    更新日期:2018-04-01 00:00:00

  • Spinal cord stimulation: principles of past, present and future practice: a review.

    abstract::Electric energy have been in use for the treatment of various ailments, including pain, since the time of Pharaohs. The theoretical basis of electrotherapy of pain was provided by the Gate Control Theory of Melzak and Wall. In 1965, Shealey et al. first introduced electrical stimulation of spinal cord for treating pai...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,评审

    doi:10.1007/s10877-009-9201-0

    authors: Kunnumpurath S,Srinivasagopalan R,Vadivelu N

    更新日期:2009-10-01 00:00:00

  • Validation of an automated system for detecting ineffective triggering asynchronies during mechanical ventilation: a retrospective study.

    abstract::We compare the sensitivity and specificity of clinician visual waveform analysis against an automated system's waveform analysis in detecting ineffective triggering in mechanically ventilated intensive care unit patients when compared against a reference label set based upon analysis of respiratory muscle activity. El...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00442-5

    authors: Phan TS,Costa R,Haddad WM,Mullis JC,Price LT,Cason AD,Bailey JM,Gholami B

    更新日期:2020-12-01 00:00:00

  • The initial tangent of the aortic pressure increase is an estimate of left ventricular contractility in pigs.

    abstract::The aim was, to identify an estimate of left ventricular contractility derived from the aortic pressure wave without load changing manoeuvres. For this purpose, left ventricular contractility was assessed with several aortic pressure wave form derived parameters and was compared to standard parameters of left ventricu...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-008-9145-9

    authors: Kisch-Wedel H,Kemming G,Meisner F,Flondor M,Bruhn S,Koehler C,Zwissler B

    更新日期:2008-10-01 00:00:00

  • A new calibration method that compensates for the effects of O2 and N2 on infrared CO2 analysers.

    abstract:OBJECTIVE:This study evaluates a method for calibrating mainstream CO(2) analysers in which CO(2) partial pressure (P (CO2)) is calculated as a function of the outputs of CO(2) and O(2) analysers. METHODS:Three mass flow controllers were used to generate 25 different reference mixtures of O(2), N(2) and CO(2). Referen...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-005-9005-9

    authors: Tang Y,Turner MJ,Baker AB

    更新日期:2006-04-01 00:00:00

  • Accuracy and trending ability of hemoglobin measurement by the Pulse CO-Oximeter during vascular surgery.

    abstract::Real time information of Hb concentration can guide a tailored patient blood management. The study investigates the accuracy, precision and trending ability of the Pulse CO-Oximeter (SpHb) and blood gas analyzer in measuring the Hb concentration, compared to hematological analysis, in surgery at high risk of hemorrhag...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00337-5

    authors: De Rosa RC,Romano GM,Abbate R,Corcione A,De Robertis E

    更新日期:2020-06-01 00:00:00

  • Ventilation monitoring during moderate sedation in GI patients.

    abstract::Sedation in locations outside the operating room (OR) is common. Guidelines for safe patient monitoring have been updated by the American Society of Anesthesiology to include monitoring of ventilation and/or carbon dioxide (CO2). Although technologies exist to monitor these variables, the quality and/or availability o...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-015-9809-1

    authors: Ebert TJ,Middleton AH,Makhija N

    更新日期:2017-02-01 00:00:00

  • Assessment of pulmonary mechanics in mechanical ventilation: effects of imprecise breath detection, phase shift and noise.

    abstract:OBJECTIVE:In mechanical ventilation, the assessment of pulmonary mechanics, mainly of total compliance (Crs), total resistance (Rrs), and intrinsic positive end-expiratory pressure (PEEPint), is clinically important. By using airway pressure (Paw) and flow (V'aw), the least squares fit (LSF) method allows the continuou...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1007457829405

    authors: Stegmaier PA,Zollinger A,Brunner JX,Pasch T

    更新日期:1998-02-01 00:00:00

  • Comparison of Univent tube and EZ blocker in one lung ventilation; airway pressures and gas exchange.

    abstract::Univent tube (UT) and EZ-blocker were used for one-lung ventilation (OLV). UT is a single lumen tube with a small separate lumen containing a bronchial blocker. EZ-blocker differs with its unique y-shaped double-cuffed distal end. We aimed to compare these two airway devices effects on airway pressures, oxygenation, v...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10877-017-0028-9

    authors: Hoşten T,Aksu C,Kuş A,Cesur S,Türkyılmaz N,Solak M

    更新日期:2018-04-01 00:00:00

  • Effects of a sigh on the respiratory mechanical properties in ali patients.

    abstract:OBJECTIVES:The application of sighs during baseline ventilation was found to improve alveolar recruitment and oxygenation in patients with acute respiratory distress syndrome (ARDS). The present investigation evaluates if respiratory mechanics can be modified by a sigh. METHODS:Ten consecutive patients with acute lung...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10877-006-9028-x

    authors: Antonaglia V,Pascotto S,Simoni LD,Zin WA

    更新日期:2006-08-01 00:00:00

  • Effects of ultrasound-guided stellate-ganglion block on sleep and regional cerebral oxygen saturation in patients undergoing breast cancer surgery: a randomized, controlled, double-blinded trial.

    abstract::Numerous factors could contribute to sleep disturbances in women with breast cancer. We hypothesized that stellate ganglion block (SGB) during surgery would preserve sleep after surgery and increase intraoperative regional cerebral oxygen saturation (rSO2) on the blocked side in patients undergoing breast cancer surge...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10877-017-0074-3

    authors: Jin F,Li XQ,Tan WF,Ma H,Fang B,Tian AY,Lu HW

    更新日期:2018-10-01 00:00:00

  • Predictive data mining on monitoring data from the intensive care unit.

    abstract::The widespread implementation of computerized medical files in intensive care units (ICUs) over recent years has made available large databases of clinical data for the purpose of developing clinical prediction models. The typical intensive care unit has several information sources from which data is electronically co...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-012-9416-3

    authors: Güiza F,Van Eyck J,Meyfroidt G

    更新日期:2013-08-01 00:00:00

  • COVID-19: Pulse oximeters in the spotlight.

    abstract::From home to intensive care units, innovations in pulse oximetry are susceptible to improve the monitoring and management of patients developing acute respiratory failure, and particularly those with the coronavirus disease 2019 (COVID-19). They include self-monitoring of oxygen saturation (SpO2) from home, continuous...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 社论

    doi:10.1007/s10877-020-00550-7

    authors: Michard F,Shelley K,L'Her E

    更新日期:2020-06-23 00:00:00

  • Computerised respiratory sounds can differentiate smokers and non-smokers.

    abstract::Cigarette smoking is often associated with the development of several respiratory diseases however, if diagnosed early, the changes in the lung tissue caused by smoking may be reversible. Computerised respiratory sounds have shown to be sensitive to detect changes within the lung tissue before any other measure, howev...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-016-9887-8

    authors: Oliveira A,Sen I,Kahya YP,Afreixo V,Marques A

    更新日期:2017-06-01 00:00:00

  • A motor evoked potential trending system may discriminate outcome: retrospective application with three cases.

    abstract::This report presents a method for tracking Motor Evoked Potential (MEP) amplitudes over the course of a case using a moving least squares linear regression (LSMAs). During a case, newly obtained MEP amplitudes are compared to those predicted by a just previous linear regression (least squares moving average or LSMA). ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-018-0181-9

    authors: Jasiukaitis P,Lyon R

    更新日期:2019-06-01 00:00:00

  • The comparison of the technical parameters in endotracheal intubation devices: the Cmac, the Vividtrac, the McGrath Mac and the Kingvision.

    abstract::Currently, there are plenty of videolaryngoscopes that appear on the market. They have different specifications. Some of these features favor the fact that they are more suited for educational purposes of future operators and others can be characterized with an excellent clinical use. In this study we compared four ty...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-015-9727-2

    authors: Cierniak M,Timler D,Wieczorek A,Sekalski P,Borkowska N,Gaszynski T

    更新日期:2016-08-01 00:00:00

  • Transcranial Doppler monitoring compared with invasive monitoring of intracranial pressure during acute intracranial hypertension.

    abstract:OBJECTIVE:To determine whether a simple transcanial Doppler waveform variable-pulsatility difference (systolic - diastolic blood flow velocity) can serve as a measure of critical changes in cerebral perfusion. METHODS:Thirteen pigs were anesthetized (anesthesia maintained with halothane) and ventilated to maintain nor...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009993232534

    authors: Sidi A,Messinger G,Mahla ME

    更新日期:1999-05-01 00:00:00

  • EEG-derived pain threshold index for prediction of postoperative pain in patients undergoing laparoscopic urological surgery: a comparison with surgical pleth index.

    abstract::Recently a novel pain recognition indicator derived from electroencephalogram(EEG) signals, pain threshold index(PTI) has been developed. The aim of this study was to determine whether PTI can be used for prediction of postoperative acute pain while surgical pleth index(SPI) applied as control. Eighty patients undergo...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00604-w

    authors: Wang R,Deng Y,Zhou S,Zhang J

    更新日期:2020-10-12 00:00:00

  • Comparison of clinical performance of size 1.5 Supreme™ LMA and Proseal™ LMA among Asian children: a randomized controlled trial.

    abstract::To date, most of the studies on safety and efficacy of supraglottic airway devices were done in Caucasian patients, and the results may not be extrapolated to Asian patients due to the different airway anatomy. We conducted this study to compare Supreme™ LMA (SLMA) and Proseal™ LMA (PLMA) size 1.5 in anaesthetized chi...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10877-018-0109-4

    authors: Chaw SH,Shariffuddin II,Foo LL,Lee PK,Paran RM,Cheang PC,Chan L

    更新日期:2018-12-01 00:00:00