Abstract:
:Bioreactance is a novel non-invasive method for cardiac output measurement that involves the analysis of blood flow-dependent changes in the phase shifts of electrical currents applied across the chest. The present study (1) compared resting and exercise cardiac outputs determined by bioreactance and bioimpedance methods and those estimated from measured oxygen consumption, (2) determined the relationship between cardiac output and oxygen consumption, and (3) assessed the agreement between the bioreactance and bioimpedance methods. Twelve healthy subjects (aged 30 ± 4 years) performed graded cardiopulmonary exercise test on a recumbent cycle ergometer on two occasions, 1 week apart. Cardiac output was monitored at rest, at 30, 50, 70, 90, 150 W and at peak exercise intensity by bioreactance and bioimpedance and expired gases collected. Resting cardiac output was not significantly different between the bioreactance and bioimpedance methods (6.2 ± 1.4 vs. 6.5 ± 1.4 l min(-1), P = 0.42). During exercise cardiac outputs were correlated with oxygen uptake for both bioreactance (r = 0.84, P < 0.01) and bioimpedance techniques (r = 0.82, P < 0.01). At peak exercise bioimpedance estimated significantly lower cardiac outputs than both bioreactance and theoretically calculated cardiac output (14.3 ± 2.6 vs. 17.5 ± 5.2 vs. 16.9 ± 4.9 l min(-1), P < 0.05). Bland-Altman analyses including data from rest and exercise demonstrated that the bioimpedance method reported ~1.5 l min(-1) lower cardiac output than bioreactance with lower and upper limits of agreement of -2.98 to 5.98 l min(-1). Bioimpedance and bioreactance methods provide different cardiac output estimates, particularly at high exercise intensity, and therefore the two methods cannot be used interchangeably. In contrast with bioimpedance, bioreactance cardiac outputs are similar to those estimated from measured oxygen consumption.
journal_name
J Clin Monit Computjournal_title
Journal of clinical monitoring and computingauthors
Jakovljevic DG,Moore S,Hallsworth K,Fattakhova G,Thoma C,Trenell MIdoi
10.1007/s10877-012-9334-4subject
Has Abstractpub_date
2012-04-01 00:00:00pages
63-8issue
2eissn
1387-1307issn
1573-2614journal_volume
26pub_type
杂志文章abstract::Pulmonary air embolism is a well-known consequence of surgery, trauma, diving, and aviation. This article reviews the physiological effects, means of detection and methods of prevention and treatment of pulmonary air embolism. The primary physiological effects are elevated pulmonary artery pressures, increased ventila...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章,评审
doi:10.1023/a:1011455701892
更新日期:2000-01-01 00:00:00
abstract::Water retention and intercompartmental redistribution occur frequently in association with adverse postoperative outcomes, yet the available strategies for non-invasive assessment are limited. One such approach for evaluating body water composition in various circumstances is bio-electrical impedance analysis (BIA). T...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-019-00334-8
更新日期:2020-06-01 00:00:00
abstract::Near-infrared spectroscopy (NIRS) has been used to detect in vivo microvascular alterations by means of a vascular occlusion test. We sought to analyse by NIRS the microcirculatory profile of patients undergoing prolonged tourniquet-induced bloodless condition for extremity surgery, and compare the results with time o...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-016-9877-x
更新日期:2017-06-01 00:00:00
abstract:OBJECTIVE:This study evaluates a method for calibrating mainstream CO(2) analysers in which CO(2) partial pressure (P (CO2)) is calculated as a function of the outputs of CO(2) and O(2) analysers. METHODS:Three mass flow controllers were used to generate 25 different reference mixtures of O(2), N(2) and CO(2). Referen...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-005-9005-9
更新日期:2006-04-01 00:00:00
abstract::Unnecessary variation in clinical care and clinical research reduces our ability to determine what healthcare interventions are effective. Reducing this unnecessary variation could lead to further healthcare quality improvement and more effective clinical research. We have developed and used electronic decision suppor...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-012-9356-y
更新日期:2012-08-01 00:00:00
abstract::The use of sedation for diagnostic procedures including gastrointestinal endoscopy is rapidly growing. Recovery of cognitive function after sedation is important because it would be important for most patients to resume safe, normal life soon after the procedure. Computerized tests have shown being accurate descriptor...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-018-0134-3
更新日期:2019-02-01 00:00:00
abstract::The test of the inner tube integrity is an important checklist prior to the safe use of Bain's breathing system. This is because the major concern with the use of Bain's circuit is the potential malfunctioning of the circuit due to avulsion of the inner fresh gas delivery tube at the machine end which will turn the ou...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-009-9212-x
更新日期:2010-02-01 00:00:00
abstract:OBJECTIVE:To determine if an automatic algorithm using wavelet analysis techniques can be used to reliably determine respiratory rate from the photoplethysmogram (PPG). METHODS:Photoplethysmograms were obtained from 12 spontaneously breathing healthy adult volunteers. Three related wavelet transforms were automaticall...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-005-9007-7
更新日期:2006-02-01 00:00:00
abstract::The precise relation between heart rate variability (HRV) and autonomic re-innervation has not been established explicitly in patients after orthotopic heart transplantation (OHT), but can be inferred from the fact that the HRV is reduced immediately after OHT and may increase gradually with time. The aim of this stud...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-015-9747-y
更新日期:2016-10-01 00:00:00
abstract::Loss of endotracheal cuff pressure can lead to airway compromise and loss of volume delivery in mechanical ventilation requiring immediate intervention. A 40 years old male posted for bilateral interpositional arthroplasty was intubated nasally with 7.5 mm flexometallic endotracheal tube. In the intraoperative period ...
journal_title:Journal of clinical monitoring and computing
pub_type: 信件
doi:10.1007/s10877-020-00607-7
更新日期:2020-10-23 00:00:00
abstract::Real time information of Hb concentration can guide a tailored patient blood management. The study investigates the accuracy, precision and trending ability of the Pulse CO-Oximeter (SpHb) and blood gas analyzer in measuring the Hb concentration, compared to hematological analysis, in surgery at high risk of hemorrhag...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-019-00337-5
更新日期:2020-06-01 00:00:00
abstract::Low fresh gas flows (FGFs) decrease the use of anesthetic gases, but increase CO2 absorbent usage. CO2 absorbent usage remains poorly quantified. The goal of this study is to determine canister life of 8 commercially available CO2 absorbent prepacks with the Zeus®. Pre-packed CO2 canisters of 8 different brands were t...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-017-0088-x
更新日期:2018-10-01 00:00:00
abstract::In mechanical ventilation, a careful setting of the ventilation parameters in accordance with the current individual state of the lung is crucial to minimize ventilator induced lung injury. Positive end-expiratory pressure (PEEP) has to be set to prevent collapse of the alveoli, however at the same time overdistension...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章,多中心研究
doi:10.1007/s10877-014-9562-x
更新日期:2014-12-01 00:00:00
abstract::Compared with supine positioning, head-up positioning improves preoxygenation and prolongs the time to oxygen desaturation. We reevaluated benefits of head-up positioning using near-infrared spectroscopy (NIRS) with pulse oximetry in a pig model. Six pigs (mean ± SD weight: 25.3 ± 0.6 kg) were anesthetized with isoflu...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-019-00456-z
更新日期:2020-01-02 00:00:00
abstract:OBJECTIVE:The mid-latency auditory evoked potential (MLAEP) has been used to indicate depth of anaesthesia, and is usually analysed in time-domain. This work compares three techniques: Wave Deformation Parameters (PDO), Auditory Evoked Potential Index (AEPidx) and an automatic Nb-wave latency estimator (Nb), in the ass...
journal_title:Journal of clinical monitoring and computing
pub_type: 临床试验,杂志文章
doi:10.1023/a:1024208827407
更新日期:2002-08-01 00:00:00
abstract::Sedation in locations outside the operating room (OR) is common. Guidelines for safe patient monitoring have been updated by the American Society of Anesthesiology to include monitoring of ventilation and/or carbon dioxide (CO2). Although technologies exist to monitor these variables, the quality and/or availability o...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-015-9809-1
更新日期:2017-02-01 00:00:00
abstract::Recent advance in imaging modalities used frequently in clinical routine can provide description of the geometrical and hemodynamical properties of the arterial tree in great detail. The combination of such information with models of blood flow of the arterial tree can provide further information, such as details in p...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章,评审
doi:10.1007/s10877-012-9382-9
更新日期:2012-10-01 00:00:00
abstract::We assessed the effect of re-calibration time on cardiac output estimation and trending performance in a retrospective analysis of an intensive care unit patient population using error grid analyses. Paired thermodilution and arterial blood pressure waveform measurements (N = 2141) from 222 patient records were extrac...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-015-9749-9
更新日期:2016-10-01 00:00:00
abstract:OBJECTIVE:Awareness with recall is a rare but serious complication of general anaesthesia with an incidence ranging from 0.1%-0.7%. In the absence of a reliable depth-of-anaesthesia monitor, attempts have been made to predict awareness from intraoperative haemodynamic monitoring data, with little success. Artificial ne...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1023/a:1015426015547
更新日期:2002-01-01 00:00:00
abstract::Recent advances in technology have brought many kinds of monitoring devices into the operating room (OR). The information gathered by monitors can be channeled to the operating ward information system via a local area network (LAN). Connecting patients to monitors and monitors to the LAN, however, requires a large num...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1023/a:1009911208828
更新日期:2000-01-01 00:00:00
abstract::Supra-sternal Doppler (USCOM Ltd., Sydney, Australia) can be used during anaesthesia to measure cardiac output (CO) and related flow parameters. However, before the USCOM can be used routinely, its utility and limitations need to be fully understood and critical information about its use disseminated. In "Window to th...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-013-9499-5
更新日期:2014-02-01 00:00:00
abstract:OBJECTIVE:We tested whether a newly installed neuromuscular monitoring device (NMT) with a computerized anesthesia recording system, incorporated in all anesthesia stations, could enhance the commitment to objective neuromuscular monitoring in a teaching hospital anesthesia department. METHODS:After 6 months of famili...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-008-9135-y
更新日期:2008-08-01 00:00:00
abstract::The number of high-risk patients undergoing surgery is growing. To maintain adequate hemodynamic functioning as well as oxygen delivery to the vital organs (DO2) amongst this patient population, a rapid assessment of cardiac functioning is essential for the anesthesiologist. Pinpointing any underlying cardiovascular p...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章,评审
doi:10.1007/s10877-020-00534-7
更新日期:2020-05-26 00:00:00
abstract:BACKGROUND AND OBJECTIVE:Ventricular late potentials (LP) recording with signal-averaged electrocar- diogram allow identifying patients at risk of sudden death and ventricular tachycardia. Cardiac surgery with cardiopulmonary bypass (CPB) could predispose to the development of myocardial ischemia related to imperfect c...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-011-9305-1
更新日期:2011-08-01 00:00:00
abstract::Increasing process complexity in the pediatric intensive care unit (PICU) can lead to information overload resulting in missing pertinent information and potential errors during morning rounds. An efficient model using a novel electronic rounding tool was designed as part of a broader critical care decision support sy...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-016-9946-1
更新日期:2017-12-01 00:00:00
abstract::The eye lens is one of the most sensitive organs for radiation injury and exposure might lead to radiation induced cataract. Eye lens dosimetry in anesthesiology has been published in few clinical trials and an active debate about the causality of radiation induced cataract is still ongoing. Recently, the Internationa...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-016-9857-1
更新日期:2017-04-01 00:00:00
abstract::Transesophageal echocardiography of the spine has been difficult to perform, and high-quality images have been difficult to obtain with earlier available technology. New capabilities in hardware and software reconstruction may allow more reliable clinical data to be obtained. We describe an initial successful attempt ...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-014-9576-4
更新日期:2015-02-01 00:00:00
abstract::This report presents a method for tracking Motor Evoked Potential (MEP) amplitudes over the course of a case using a moving least squares linear regression (LSMAs). During a case, newly obtained MEP amplitudes are compared to those predicted by a just previous linear regression (least squares moving average or LSMA). ...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-018-0181-9
更新日期:2019-06-01 00:00:00
abstract::Changes have been made to the AnaConDa device (Sedana Medical, Stockholm, Sweden), decreasing its size to reduce dead space and carbon dioxide (CO2) retention. However, this also involves a decrease in the surface area of the activated carbon filter. The CO2 elimination and sevoflurane (SEV) reflection of the old devi...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-019-00285-0
更新日期:2020-02-01 00:00:00
abstract::Cigarette smoking is often associated with the development of several respiratory diseases however, if diagnosed early, the changes in the lung tissue caused by smoking may be reversible. Computerised respiratory sounds have shown to be sensitive to detect changes within the lung tissue before any other measure, howev...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-016-9887-8
更新日期:2017-06-01 00:00:00