:The use of sedation for diagnostic procedures including gastrointestinal endoscopy is rapidly growing. Recovery of cognitive function after sedation is important because it would be important for most patients to resume safe, normal life soon after the procedure. Computerized tests have shown being accurate descriptors of cognitive function. The purpose of the present study was to evaluate the time course of cognitive function recovery after sedation with propofol and remifentanil. A prospective observational double blind clinical study conducted in 34 young healthy adults undergoing elective outpatient colonoscopy under sedation with the combination of propofol and remifentanil using a target controlled infusion system. Cognitive function was measured using a validated battery of computerized cognitive tests (Cogstate™, Melbourne, Australia) at different predefined times: prior to starting sedation (Tbaseline), and then 10 min (T10), 40 min (T40) and 120 min (T120) after the end of colonoscopy. Tests included the assessment of psychomotor function, attention, visual memory and working memory. All colonoscopies were completed (median time: 26 min) without significant adverse events. Patients received a median total dose of propofol and remifentanil of 149 mg and 98 µg, respectively. Psychomotor function and attention declined at T10 but were back to baseline values at T40 for all patients. The magnitude of psychomotor task reduction was large (d = 0.81) however 100% of patients were recovered at T40. Memory related tasks were not affected 10 min after ending sedation. Cognitive impairment in attention and psychomotor function after propofol and remifentanil sedation was significant and large and could be easily detected by computerized cognitive tests. Even though, patients were fully recovered 40 min after ending the procedure. From a cognitive recovery point of view, larger studies should be undertaken to propose adequate criteria for discharge after sedation.
journal_name
J Clin Monit Computjournal_title
Journal of clinical monitoring and computingauthors
Borrat X,Ubre M,Risco R,Gambús PL,Pedroso A,Iglesias A,Fernandez-Esparrach G,Ginés À,Balust J,Martínez-Palli Gdoi
10.1007/s10877-018-0134-3subject
Has Abstractpub_date
2019-02-01 00:00:00pages
107-113issue
1eissn
1387-1307issn
1573-2614pii
10.1007/s10877-018-0134-3journal_volume
33pub_type
杂志文章abstract::From home to intensive care units, innovations in pulse oximetry are susceptible to improve the monitoring and management of patients developing acute respiratory failure, and particularly those with the coronavirus disease 2019 (COVID-19). They include self-monitoring of oxygen saturation (SpO2) from home, continuous...
journal_title:Journal of clinical monitoring and computing
pub_type: 社论
doi:10.1007/s10877-020-00550-7
更新日期:2020-06-23 00:00:00
abstract::The composite auditory evoked potentials index (cAAI) uses both cortical electroencephalogram (EEG) and response to auditory stimuli, while the bispectral index (BIS) uses only the cortical EEG and auditory evoked potentials index (AAI) uses only response to auditory stimuli. We expected that the cAAI was more useful ...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章,随机对照试验
doi:10.1007/s10877-013-9441-x
更新日期:2013-06-01 00:00:00
abstract::Microvascular function may be modulated by various anesthetics. Desflurane and propofol anesthesia have different effects on microvascular function. However, there are few reports on the effects of sevoflurane and desflurane on microvascular function during cardiac surgery. We compared the effects of sevoflurane and d...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-020-00587-8
更新日期:2020-09-11 00:00:00
abstract::Auditory steady state responses (ASSR) may offer an alternative to brainstem auditory evoked potentials for monitoring of the auditory nerve during surgical procedures. In the current study, we evaluated the influence of noise on ASSR characteristics in total intravenous anesthesia (TIVA). Simulated ASSR in real noise...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-016-9837-5
更新日期:2017-02-01 00:00:00
abstract:OBJECTIVE:To further elucidate temperature related changes in subcortical components of somatosensory evoked potentials (SEP) in intraoperative monitoring. METHODS:Intraoperative monitoring of subcortical median nerve SEP under deep hypothermia is described in a patient undergoing intracranial giant aneurysm surgery. ...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1023/a:1020792729242
更新日期:2002-04-01 00:00:00
abstract:OBJECTIVE:An atypical "tails-up" capnograph pattern was noticed in a patient during the use of an accidentally crushed sampling tube with a slit-like hole. We investigated the mechanics involved in the observed capnograph pattern. METHODS:Forty consenting ASA I patients of both sexes presenting for tonsillectomy were ...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1023/a:1009990210114
更新日期:2000-01-01 00:00:00
abstract::The aim of this study was to compare the cardiac function index (CFI) and global ejection fraction (GEF) obtained by VolumeView/EV1000™, with the left ventricular ejection fraction (LVEF) by echocardiography in septic shock patients. A prospective observational study was conducted in a medical intensive care unit of a...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-018-0152-1
更新日期:2019-04-01 00:00:00
abstract:OBJECTIVES:This study was conducted to determine the response time of the Opti-Q continuous cardiac output (CCO) device to a step change in cardiac. DESIGN:Prospective study. SETTING:University hospital animal lab. MODEL:Female sheep. INTERVENTIONS:In ten animals, cardiac output was altered suddenly by opening and ...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1023/a:1009934112134
更新日期:1999-12-01 00:00:00
abstract::Central venous pressure (CVP) is an important clinical parameter for physicians but only the absolute CVP value is typically monitored in the intensive care unit (ICU). In this study, we propose a novel mathematical method to present and analyze CVP signals. A total of 44 suitable samples were chosen from a total of 6...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-016-9882-0
更新日期:2017-06-01 00:00:00
abstract::This prospective study evaluates haemodynamic and electroencephalographic effects observed when administering four combinations of effect-site concentrations of propofol (CePROP) and remifentanil (CeREMI), all yielding a single predicted probability of tolerance of laryngoscopy of 90% (PTOL = 90%) according to the Bou...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-020-00540-9
更新日期:2020-06-03 00:00:00
abstract::Patient-ventilator asynchrony is associated with intolerance to noninvasive ventilation (NIV) and worsened outcomes. Our goal was to develop a tool to determine a patient needs for intervention by a practitioner due to the presence of patient-ventilator asynchrony. We postulated that a clinician can determine when a ...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-019-00408-7
更新日期:2020-10-01 00:00:00
abstract::FloTrac/Vigileo™ system is based on arterial pressure waveform analysis arterial pressure-based CO (APCO). Therefore, systemic vascular resistance (SVR) can influence the accuracy of APCO. The purpose of this study is to evaluate the relationship between SVR and the accuracy of APCO. We managed 50 consecutive patients...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-013-9481-2
更新日期:2013-12-01 00:00:00
abstract::The Sensmart Model X-100 (Nonin Medical Inc, Plymouth, MN, USA) is a relatively new device that possesses two sets of emitters and detectors and uses near infrared spectroscopy (NIRS) to measure regional cerebral oxygen saturation (rSO2). The value of rSO2 obtained by other NIRS devices is affected by physiological an...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-020-00567-y
更新日期:2020-07-31 00:00:00
abstract::The Nexfin device allows for non-invasive beat-to-beat blood pressure monitoring (BP(NXF)). Perioperative hypotension and hypertension have been shown to be associated with poor clinical outcomes. The goal of the present study was to assess the ability of this device to decrease the duration of significant intraoperat...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-012-9344-2
更新日期:2012-04-01 00:00:00
abstract::One of the main goals of hemodynamic support is to preserve tissue perfusion. However issue perfusion is related more to microvascular perfusion than aortic blood flow. Monitoring the microcirculation has long been difficult. Recent technologic advances have made feasible monitoring of the microcirculation at bedside ...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章,评审
doi:10.1007/s10877-012-9383-8
更新日期:2012-10-01 00:00:00
abstract:OBJECTIVE:To develop an ergonomically designed computerized recordkeeping tool for anesthesiologists that allows the clinician to maintain visual contact with the patient while performing recordkeeping. METHODS:To simplify the human interface software, we developed two general use software components. All purpose menu...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1023/a:1009972223750
更新日期:1999-08-01 00:00:00
abstract:BACKGROUND:The value of the impedance cardiography (IC) method for measuring cardiac output (CO) with the subject in the left lateral position has not yet been established. We compared the CO after a 30 degrees head-up tilt with the subjects in the supine and left lateral position. METHODS:Thirty healthy young volunte...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1023/a:1009968513512
更新日期:1999-12-01 00:00:00
abstract::An intraoperative automated closed-loop system for goal-directed fluid therapy has been successfully tested in silico, in vivo and in a clinical case-control matching. This trial compared intraoperative cardiac output (CO) in patients managed with this closed-loop system versus usual practice in an academic medical ce...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章,随机对照试验
doi:10.1007/s10877-018-0106-7
更新日期:2018-12-01 00:00:00
abstract:OBJECTIVE:Upper airway obstruction is the most rapid and clinically relevant cause of hypoxia during sedation and anesthesia. This study was designed to determine if respiratory inductance plethysmography (RIP) could quantify the degree of upper airway obstruction caused by induction of general anesthesia. METHODS:RIP...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1023/a:1021246119194
更新日期:2002-07-01 00:00:00
abstract:OBJECTIVE:Transcranial Motor Evoked Potentials (TcMEPs) are sometimes used during lumbar spine surgery in order to detect and prevent an intraoperative nerve root injury. Typically, a fixed stimulus is applied, and one monitors for changes in response amplitude from several myotomes. Increased stimulating voltage may o...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-010-9269-6
更新日期:2010-12-01 00:00:00
abstract::We compare the sensitivity and specificity of clinician visual waveform analysis against an automated system's waveform analysis in detecting ineffective triggering in mechanically ventilated intensive care unit patients when compared against a reference label set based upon analysis of respiratory muscle activity. El...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-019-00442-5
更新日期:2020-12-01 00:00:00
abstract::Recent progress in genomics and experimental biology has brought exponential growth of the biological information available for computational analysis in public genomics databases. However, applying the potentially enormous scientific value of this information to the understanding of biological systems requires comput...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-005-3463-y
更新日期:2005-10-01 00:00:00
abstract:BACKGROUND:The ventricular stroke work refers to the work done by the left or right ventricle to eject the volume of blood during one cardiac cycle, called stroke volume. Sarnoff and Berglund were one of the first to calculate the stroke work from the pressure volume diagram in 1954. However, they published a wrong uni...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章,评审
doi:10.1007/s10877-010-9234-4
更新日期:2010-06-01 00:00:00
abstract:OBJECTIVE:To compare expert-generated textual summaries of physiological data with trend graphs, in terms of their ability to support neonatal Intensive Care Unit (ICU) staff in making decisions when presented with medical scenarios. METHODS:Forty neonatal ICU staff were recruited for the experiment, eight from each o...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-005-0879-3
更新日期:2005-06-01 00:00:00
abstract::Alarms in the operating room remain a major source of annoyance and confusion. Nearly all alarms result from a transgression of certain alarm limits. We surveyed manufacturers at a major meeting of anesthesiologists for their default alarm limits. We also conducted a mail survey of anesthesiologists in the United Stat...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1023/a:1009992830942
更新日期:1999-02-01 00:00:00
abstract::The physiology underlying the intracranial pressure (ICP) curve morphology is not fully understood. Recent research has suggested that the morphology could be dependent on arterial cerebral inflow and the physiological and pathophysiological properties of the intracranial cavity. If understood, the ICP curve could pro...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-019-00342-8
更新日期:2020-06-01 00:00:00
abstract:OBJECTIVE:To demonstrate the usefulness of rectus femoris muscle MEPs monitoring in a paraparetic neuromuscular scoliosis case. METHODS:Multiple monitoring modalities including SEPs, MEPs and EMG were performed for an anterior and posterior correction surgery for a neuromuscular scoliosis patient with no motor and sen...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-011-9325-x
更新日期:2012-02-01 00:00:00
abstract:OBJECTIVE:To present a decision support system for optimising mechanical ventilation in patients residing in the intensive care unit. METHODS:Mathematical models of oxygen transport, carbon dioxide transport and lung mechanics are combined with penalty functions describing clinical preference toward the goals and side...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-006-9049-5
更新日期:2006-12-01 00:00:00
abstract::The aim was, to identify an estimate of left ventricular contractility derived from the aortic pressure wave without load changing manoeuvres. For this purpose, left ventricular contractility was assessed with several aortic pressure wave form derived parameters and was compared to standard parameters of left ventricu...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-008-9145-9
更新日期:2008-10-01 00:00:00
abstract::To develop and validate a mathematical model for predicting intracranial pressure (ICP) noninvasively using phase-contrast cine MRI (PC-MRI). We performed a retrospective analysis of PC-MRI from patients with communicating hydrocephalus (n = 138). The patients were recruited from Shenzhen Second People's Hospital betw...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-020-00598-5
更新日期:2020-10-01 00:00:00