A motor evoked potential trending system may discriminate outcome: retrospective application with three cases.

Abstract:

:This report presents a method for tracking Motor Evoked Potential (MEP) amplitudes over the course of a case using a moving least squares linear regression (LSMAs). During a case, newly obtained MEP amplitudes are compared to those predicted by a just previous linear regression (least squares moving average or LSMA). When detected by this comparison, a set criterion amplitude loss will then trigger linear regression of ensuing MEP amplitudes on an expanding step function which tracks the persistence of the amplitude loss for the remainder of the case. Three cases are presented. One in which the patient woke up with a newly acquired weakness in the left tibialis anterior and another in which MEP amplitudes were suddenly lost from the right foot, but after intervention, they were restored again. In a third case the patient again woke up with a new post-operative deficit, but MEP trial sampling had been more limited and variable than in the first two cases. When the linear trending method was applied to the affected myotome in the first case, the expanding step function regression was triggered after the moment of MEP loss and remained at a high level until the end of case. In the second case, the expanding step function regression was also triggered in the relevant myotome at the time of the reported MEP change, but diminished by end of case. In the third case the tracking method again successfully triggered a predictive R-Square despite the limited number of pre-event trials. The R-Square value of the expanding step function regression appears to have discriminative capability with regard to new post-op deficit. Given the importance of the intra-operative MEP for monitoring motor functioning and the high degree of variability that can affect it, the development of new quantitative, statistical methods to detect real from apparent MEP change will be necessary.

journal_name

J Clin Monit Comput

authors

Jasiukaitis P,Lyon R

doi

10.1007/s10877-018-0181-9

subject

Has Abstract

pub_date

2019-06-01 00:00:00

pages

481-491

issue

3

eissn

1387-1307

issn

1573-2614

pii

10.1007/s10877-018-0181-9

journal_volume

33

pub_type

杂志文章
  • Selection of cuffed endotracheal tube for children with congenital heart disease based on an ultrasound-based linear regression formula.

    abstract::It remains to be discovered whether a formula predicting the subglottic transverse diameter measured by ultrasound (SGDformula) for the selection of an appropriate endotracheal tube (ETT) for children without congenital heart disease (CHD) is useful for children with CHD. A formula for predicting SGD was established a...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-018-0203-7

    authors: Zhang K,Ma RJ,Zheng JJ,Chen YQ,Zhang MZ

    更新日期:2019-08-01 00:00:00

  • COVID-19: Pulse oximeters in the spotlight.

    abstract::From home to intensive care units, innovations in pulse oximetry are susceptible to improve the monitoring and management of patients developing acute respiratory failure, and particularly those with the coronavirus disease 2019 (COVID-19). They include self-monitoring of oxygen saturation (SpO2) from home, continuous...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 社论

    doi:10.1007/s10877-020-00550-7

    authors: Michard F,Shelley K,L'Her E

    更新日期:2020-06-23 00:00:00

  • Time-variant investigation of quadratic phase couplings caused by amplitude modulation in electroencephalic burst-suppression patterns.

    abstract:OBJECTIVE:Several studies suggest that parameters derived from bispectral analysis of the EEG can be used to characterize specific cortical activation states represented by non linear interaction between brain electrical oscillations. For example, it was shown that so-called bispectral indices can be used to assess the...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1016362209175

    authors: Arnold M,Witte H,Schelenz C

    更新日期:2002-02-01 00:00:00

  • Accuracy and trending ability of hemoglobin measurement by the Pulse CO-Oximeter during vascular surgery.

    abstract::Real time information of Hb concentration can guide a tailored patient blood management. The study investigates the accuracy, precision and trending ability of the Pulse CO-Oximeter (SpHb) and blood gas analyzer in measuring the Hb concentration, compared to hematological analysis, in surgery at high risk of hemorrhag...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00337-5

    authors: De Rosa RC,Romano GM,Abbate R,Corcione A,De Robertis E

    更新日期:2020-06-01 00:00:00

  • Analysis of central venous pressure (CVP) signals using mathematical methods.

    abstract::Central venous pressure (CVP) is an important clinical parameter for physicians but only the absolute CVP value is typically monitored in the intensive care unit (ICU). In this study, we propose a novel mathematical method to present and analyze CVP signals. A total of 44 suitable samples were chosen from a total of 6...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-016-9882-0

    authors: Atefvahid P,Hassani K,Jafarian K,Doyle DJ,Ahmadi H

    更新日期:2017-06-01 00:00:00

  • Pulmonary air embolism.

    abstract::Pulmonary air embolism is a well-known consequence of surgery, trauma, diving, and aviation. This article reviews the physiological effects, means of detection and methods of prevention and treatment of pulmonary air embolism. The primary physiological effects are elevated pulmonary artery pressures, increased ventila...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,评审

    doi:10.1023/a:1011455701892

    authors: Souders JE

    更新日期:2000-01-01 00:00:00

  • Clinical evaluation of stretchable and wearable inkjet-printed strain gauge sensor for respiratory rate monitoring at different measurements locations.

    abstract::The respiration rate (RR) is a vital sign in physiological measurement and clinical diagnosis. RR can be measured using stretchable and wearable strain gauge sensors which detect the respiratory movements in the abdomen or thorax areas caused by volumetric changes. In different body locations, the accuracy of RR detec...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00481-3

    authors: Al-Halhouli A,Al-Ghussain L,El Bouri S,Liu H,Zheng D

    更新日期:2020-02-22 00:00:00

  • The sounds of saturation.

    abstract::Audible pulse tones, based on a variable-pitch frequency scale, allow the anesthesiologist to determine the patient's oxygen saturation without constant visual examination of the monitor display. The ability to reliably detect oxygen saturation levels based on audible pulse tones may be compromised when multiple pulse...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/b:jocm.0000032698.47717.06

    authors: Santamore DC,Cleaver TG

    更新日期:2004-04-01 00:00:00

  • Increases in voltage may produce false-negatives when using transcranial motor evoked potentials to detect an isolated nerve root injury.

    abstract:OBJECTIVE:Transcranial Motor Evoked Potentials (TcMEPs) are sometimes used during lumbar spine surgery in order to detect and prevent an intraoperative nerve root injury. Typically, a fixed stimulus is applied, and one monitors for changes in response amplitude from several myotomes. Increased stimulating voltage may o...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-010-9269-6

    authors: Lyon R,Gibson A,Burch S,Lieberman J

    更新日期:2010-12-01 00:00:00

  • The pressure exerted on the tongue during intubation with simultaneous cervical spine immobilisation: a comparison between four videolaryngoscopes and the Macintosh laryngoscope-a manikin study.

    abstract::Excessive pressures exerted on the tongue during intubation may be associated with serious complications and may make intubation more difficult. The aim of this study was to evaluate five different intubating devices in the hands of experienced anaesthetists during simulated conditions of reduced cervical spine mobili...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-017-0095-y

    authors: Aleksandrowicz D,Gaszyński T

    更新日期:2018-10-01 00:00:00

  • Capnography-sample line leak and incremental positive end expiratory pressure (PEEP); an interesting interplay.

    abstract::The capnography is an important monitor to assess the patient's respiratory status. Importance of education for clinicians in interpretation of alarms and various capnography waveforms in different clinical scenarios and equipment malfunction is an understatement. Capnography waveforms due to sample line tube leak is ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 信件

    doi:10.1007/s10877-019-00388-8

    authors: Jain A,Vinay B,Revanna J

    更新日期:2020-08-01 00:00:00

  • The effect of variable arterial transducer level on the accuracy of pulse contour waveform-derived measurements in critically ill patients.

    abstract::We know that a 10 cm departure from the reference level of pressure transducer position is equal to a 7.5 mmHg change of invasive hemodynamic pressure monitoring in a fluid-filled system. However, the relationship between the site level of a variable arterial pressure transducer and the pulse contour-derived parameter...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-015-9756-x

    authors: He HW,Liu DW,Long Y,Wang XT,Zhao ML,Lai XL

    更新日期:2016-10-01 00:00:00

  • Electrical impedance tomography's correlation to lung volume is not influenced by anthropometric parameters.

    abstract:STUDY OBJECTIVES:Electrical impedance tomography (EIT) is able to reflect physiological parameters such as real-time changes in global and regional lung volume. EIT can aid in the assessment of lung recruitment, and its use has been validated in preliminary studies monitoring mechanical ventilation at the bedside. ICU ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-006-9021-4

    authors: Marquis F,Coulombe N,Costa R,Gagnon H,Guardo R,Skrobik Y

    更新日期:2006-06-01 00:00:00

  • Comparison of an ultrasound-guided technique versus a landmark-guided technique for internal jugular vein cannulation.

    abstract::Central venous cannulation is a commonly preformed procedure in many branches of medicine, particularly in anaesthesia and intensive care medicine. The purpose of this study was to compare the landmark-guided technique to the ultrasound-guided technique for internal jugular vein cannulation in cardiovascular surgery p...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10877-014-9585-3

    authors: Dolu H,Goksu S,Sahin L,Ozen O,Eken L

    更新日期:2015-02-01 00:00:00

  • Cardioplegia and ventricular late potentials in cardiac surgical patients.

    abstract:BACKGROUND AND OBJECTIVE:Ventricular late potentials (LP) recording with signal-averaged electrocar- diogram allow identifying patients at risk of sudden death and ventricular tachycardia. Cardiac surgery with cardiopulmonary bypass (CPB) could predispose to the development of myocardial ischemia related to imperfect c...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-011-9305-1

    authors: Schütz N,Romand JA,Yanez ND,Treggiari MM,Bendjelid K

    更新日期:2011-08-01 00:00:00

  • A comparison of graphical and textual presentations of time series data to support medical decision making in the neonatal intensive care unit.

    abstract:OBJECTIVE:To compare expert-generated textual summaries of physiological data with trend graphs, in terms of their ability to support neonatal Intensive Care Unit (ICU) staff in making decisions when presented with medical scenarios. METHODS:Forty neonatal ICU staff were recruited for the experiment, eight from each o...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-005-0879-3

    authors: Law AS,Freer Y,Hunter J,Logie RH,McIntosh N,Quinn J

    更新日期:2005-06-01 00:00:00

  • Effects of prolonged ischemia on human skeletal muscle microcirculation as assessed by near-infrared spectroscopy.

    abstract::Near-infrared spectroscopy (NIRS) has been used to detect in vivo microvascular alterations by means of a vascular occlusion test. We sought to analyse by NIRS the microcirculatory profile of patients undergoing prolonged tourniquet-induced bloodless condition for extremity surgery, and compare the results with time o...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-016-9877-x

    authors: Tujjar O,De Gaudio AR,Tofani L,Di Filippo A

    更新日期:2017-06-01 00:00:00

  • A new calibration method that compensates for the effects of O2 and N2 on infrared CO2 analysers.

    abstract:OBJECTIVE:This study evaluates a method for calibrating mainstream CO(2) analysers in which CO(2) partial pressure (P (CO2)) is calculated as a function of the outputs of CO(2) and O(2) analysers. METHODS:Three mass flow controllers were used to generate 25 different reference mixtures of O(2), N(2) and CO(2). Referen...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-005-9005-9

    authors: Tang Y,Turner MJ,Baker AB

    更新日期:2006-04-01 00:00:00

  • GNARE: automated system for high-throughput genome analysis with grid computational backend.

    abstract::Recent progress in genomics and experimental biology has brought exponential growth of the biological information available for computational analysis in public genomics databases. However, applying the potentially enormous scientific value of this information to the understanding of biological systems requires comput...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-005-3463-y

    authors: Sulakhe D,Rodriguez A,D'Souza M,Wilde M,Nefedova V,Foster I,Maltsev N

    更新日期:2005-10-01 00:00:00

  • Validation of an automated system for detecting ineffective triggering asynchronies during mechanical ventilation: a retrospective study.

    abstract::We compare the sensitivity and specificity of clinician visual waveform analysis against an automated system's waveform analysis in detecting ineffective triggering in mechanically ventilated intensive care unit patients when compared against a reference label set based upon analysis of respiratory muscle activity. El...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00442-5

    authors: Phan TS,Costa R,Haddad WM,Mullis JC,Price LT,Cason AD,Bailey JM,Gholami B

    更新日期:2020-12-01 00:00:00

  • Monitoring the microcirculation.

    abstract::One of the main goals of hemodynamic support is to preserve tissue perfusion. However issue perfusion is related more to microvascular perfusion than aortic blood flow. Monitoring the microcirculation has long been difficult. Recent technologic advances have made feasible monitoring of the microcirculation at bedside ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,评审

    doi:10.1007/s10877-012-9383-8

    authors: De Backer D,Donadello K,Cortes DO

    更新日期:2012-10-01 00:00:00

  • Comparison of the use of AnaConDa® versus AnaConDa-S® during the post-operative period of cardiac surgery under standard conditions of practice.

    abstract::Changes have been made to the AnaConDa device (Sedana Medical, Stockholm, Sweden), decreasing its size to reduce dead space and carbon dioxide (CO2) retention. However, this also involves a decrease in the surface area of the activated carbon filter. The CO2 elimination and sevoflurane (SEV) reflection of the old devi...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00285-0

    authors: Marcos-Vidal JM,Merino M,González R,García C,Rey S,Pérez I

    更新日期:2020-02-01 00:00:00

  • Leakage of sevoflurane from vaporizer detected by air monitoring system: a case report.

    abstract::Leakage of inhalational anesthetic gases is an important issue not only to staff health but awareness during general anesthesia. After inhalation of sevoflurane commenced, the audible and visible alarm of our custom-made air monitoring system was activated. The system measured 2-4 ppm of sevoflurane. A thorough search...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-013-9479-9

    authors: Tanaka M,Yamaura K,Higashi M,Hoka S

    更新日期:2013-12-01 00:00:00

  • Effects of a sigh on the respiratory mechanical properties in ali patients.

    abstract:OBJECTIVES:The application of sighs during baseline ventilation was found to improve alveolar recruitment and oxygenation in patients with acute respiratory distress syndrome (ARDS). The present investigation evaluates if respiratory mechanics can be modified by a sigh. METHODS:Ten consecutive patients with acute lung...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10877-006-9028-x

    authors: Antonaglia V,Pascotto S,Simoni LD,Zin WA

    更新日期:2006-08-01 00:00:00

  • Assessment of the 50 % and 95 % effective paratracheal forces for occluding the esophagus in anesthetized patients.

    abstract::This study aimed to evaluate the 50% and 95% effective paratracheal forces for occluding the esophagus in anesthetized patients. In 46 anesthetized patients, the upper esophagus was examined using ultrasonography, and the lower paratracheal area over the esophagus just above the clavicle was marked. Manual paratrachea...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-021-00652-w

    authors: Kim H,Mondal S,Choi CG,Hwang JY

    更新日期:2021-01-26 00:00:00

  • Transcranial Doppler monitoring compared with invasive monitoring of intracranial pressure during acute intracranial hypertension.

    abstract:OBJECTIVE:To determine whether a simple transcanial Doppler waveform variable-pulsatility difference (systolic - diastolic blood flow velocity) can serve as a measure of critical changes in cerebral perfusion. METHODS:Thirteen pigs were anesthetized (anesthesia maintained with halothane) and ventilated to maintain nor...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009993232534

    authors: Sidi A,Messinger G,Mahla ME

    更新日期:1999-05-01 00:00:00

  • Diagnosis of anesthetic-induced upper airway obstruction in children using respiratory inductance plethysmography.

    abstract:OBJECTIVE:Upper airway obstruction is the most rapid and clinically relevant cause of hypoxia during sedation and anesthesia. This study was designed to determine if respiratory inductance plethysmography (RIP) could quantify the degree of upper airway obstruction caused by induction of general anesthesia. METHODS:RIP...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1021246119194

    authors: Litman RS,Kottra JA,Gallagher PR,Ward DS

    更新日期:2002-07-01 00:00:00

  • BAEPs averaging analysis using autoregressive modelling.

    abstract:OBJECTIVE:The present paper introduces a new perspective on the classical ensemble averaging which can be useful to analyse the Brainstem Auditory Evoked Potentials (BAEPs). The analysis of the dynamics, related to the BAEP, is performed directly after its acquisition from the electroencephalogram (EEG). METHODS:The m...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/b:jocm.0000042919.04719.a7

    authors: Vannier E,Naït-Ali A

    更新日期:2004-06-01 00:00:00

  • Infrared transmission of electronic information via LAN in the operating room.

    abstract::Recent advances in technology have brought many kinds of monitoring devices into the operating room (OR). The information gathered by monitors can be channeled to the operating ward information system via a local area network (LAN). Connecting patients to monitors and monitors to the LAN, however, requires a large num...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009911208828

    authors: Hagihira S,Takashina M,Mori T,Taenaka N,Mashimo T,Yoshiya I

    更新日期:2000-01-01 00:00:00

  • Study of light transmission through gauze pad effected by blood or liquids to detect needle dislodgement.

    abstract:OBJECTIVE:Serious accidents during hemodialysis such as a large amount of blood loss are often caused by venous needle dislodgement. To develop a bleeding sensor based on a photo sensor for monitoring the needle sites, we studied effects of liquids and porcine blood on light transmission through a thin gauze pad with a...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-009-9206-8

    authors: Takeuchi A,Ishida K,Morohoshi Y,Shinbo T,Hirose M,Ikeda N

    更新日期:2010-02-01 00:00:00