Abstract:
OBJECTIVE:The present paper introduces a new perspective on the classical ensemble averaging which can be useful to analyse the Brainstem Auditory Evoked Potentials (BAEPs). The analysis of the dynamics, related to the BAEP, is performed directly after its acquisition from the electroencephalogram (EEG). METHODS:The method primarily consists of dynamically modelling the averaged potential, obtained during the acquisition mode. Each averaging of signal at a given instant is considered as an autoregressive (AR) process. RESULTS:It has been shown that the predicting error power of AR modelling can be useful to provide an efficient tool to analyse the BAEPs. It has also been shown that the method is capable of taking the non-stationarities of both the BAEP and the EEG into account. CONCLUSION:In order to validate our approach, the proposed technique has been implemented for both simulated and real signals. This approach can also be employed in the context of estimating other evoked potentials and shows rich promise for potential clinical applications in future.
journal_name
J Clin Monit Computjournal_title
Journal of clinical monitoring and computingauthors
Vannier E,Naït-Ali Adoi
10.1023/b:jocm.0000042919.04719.a7subject
Has Abstractpub_date
2004-06-01 00:00:00pages
147-55issue
3eissn
1387-1307issn
1573-2614journal_volume
18pub_type
杂志文章abstract::Electrical impedance tomography (EIT) is used in lung physiology monitoring. There is evidence that EIT is linearly associated with global tidal volume (VT) in clinically healthy patients where no positive end-expiratory pressure (PEEP) is applied. This linearity has not been challenged by altering lung conditions. Th...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-021-00651-x
更新日期:2021-01-25 00:00:00
abstract:OBJECTIVE:To evaluate a computerized system for mechanical ventilation of infants. METHODS:FLEX is a computerized system that includes the features of a patented mode known as adaptive-support ventilation (ASV). In addition, it has many other features including adjustment of positive end-expiratory pressure (PEEP), fr...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-009-9170-3
更新日期:2009-04-01 00:00:00
abstract::Increasing process complexity in the pediatric intensive care unit (PICU) can lead to information overload resulting in missing pertinent information and potential errors during morning rounds. An efficient model using a novel electronic rounding tool was designed as part of a broader critical care decision support sy...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-016-9946-1
更新日期:2017-12-01 00:00:00
abstract:OBJECTIVE:To determine if an automatic algorithm using wavelet analysis techniques can be used to reliably determine respiratory rate from the photoplethysmogram (PPG). METHODS:Photoplethysmograms were obtained from 12 spontaneously breathing healthy adult volunteers. Three related wavelet transforms were automaticall...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-005-9007-7
更新日期:2006-02-01 00:00:00
abstract::Prediction of difficult laryngoscopy is still the uncovered secret of anesthetic practice. This pilot study is aimed to assess the efficacy of spirometry measurements in predicting difficult laryngoscopy compared with conventional airway assessment techniques. We enrolled 202 adults, ages 18-40 years, with an American...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-016-9961-2
更新日期:2017-12-01 00:00:00
abstract::The goal of the study was to evaluate the effectiveness of analgesia nociception index (ANI) monitoring during intraoperative period for patients with thoracic paravertebral block (TPVB) undergoing breast surgery under general anesthesia. This prospective randomized trial was performed after receiving ethics committee...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章,随机对照试验
doi:10.1007/s10877-017-0036-9
更新日期:2018-06-01 00:00:00
abstract::Numerous possibilities exist which may cause obstruction to ventilation under anesthesia resulting in a tight reservoir bag with low compliance. We report an interesting case where a reservoir bag twisted around its own neck and resulted in a tight bag situation. The neck portion of the reservoir bag would be hidden f...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-010-9232-6
更新日期:2010-06-01 00:00:00
abstract::To assess the feasibility, stability and predictability of pCO2 measurement (PETCO2) using a main stream capnograph in a high frequency oscillatory ventilation circuit. A commercially available capnograph was mounted into a high frequency oscillatory ventilator patient circuit, adjustable CO2 flow was introduced into ...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-013-9495-9
更新日期:2014-02-01 00:00:00
abstract::Mathematical models can be deployed to simulate physiological processes of the human organism. Exploiting these simulations, reactions of a patient to changes in the therapy regime can be predicted. Based on these predictions, medical decision support systems (MDSS) can help in optimizing medical therapy. An MDSS desi...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-013-9502-1
更新日期:2014-12-01 00:00:00
abstract::Closed loop target-control infusion systems using a Bispectral (BIS) signal as an input (TCI Loop) can automatically maintain intravenous anesthesia in a BIS range of 40-60 %. Our purpose was to assess to what extent such a system could decrease anesthesia workload in comparison to the use of a stand alone TCI system ...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章,随机对照试验
doi:10.1007/s10877-013-9453-6
更新日期:2014-02-01 00:00:00
abstract::Obstructive sleep apnea (OSA) is a risk factor for perioperative complications, but many OSA patients present undiagnosed. While polysomnography (PSG) is the "gold standard" for diagnosis, its application is technology-intense, time-consuming, expensive, and requires specialists, often delaying surgery. Thus, miniatur...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-018-0151-2
更新日期:2019-04-01 00:00:00
abstract:OBJECTIVES:Bioreactance, the analysis of intrabeat variations in phase of a transthoracic voltage in response to an applied high frequency transthoracic current, was recently introduced for noninvasive cardiac output measurement (NICOM). We evaluated NICOM compared to thermo- dilution (TD) in several clinical settings....
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章,多中心研究
doi:10.1007/s10877-008-9112-5
更新日期:2008-04-01 00:00:00
abstract::Oesophageal balloon calibration improves the oesophageal pressure (Pes) assessment during invasive controlled mechanical ventilation. The primary aim of the present investigation was to ascertain the feasibility of oesophageal balloon calibration during pressure support ventilation (PSV). Secondarily, the calibrated P...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-019-00436-3
更新日期:2020-12-01 00:00:00
abstract::Near-infrared spectrophotometry assesses cerebral oxygen saturation (ScO2) based on the absorption spectra of oxygenated and deoxygenated hemoglobin, and the translucency of biological tissue, in the near-infrared band. There is increasing evidence that optimising cerebral oxygenation, guided by ScO2, is associated wi...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-014-9642-y
更新日期:2015-10-01 00:00:00
abstract::Transesophageal echocardiography of the spine has been difficult to perform, and high-quality images have been difficult to obtain with earlier available technology. New capabilities in hardware and software reconstruction may allow more reliable clinical data to be obtained. We describe an initial successful attempt ...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-014-9576-4
更新日期:2015-02-01 00:00:00
abstract::Incident dark field imaging (IDF) is a new generation handheld microscope for bedside visualization and quantification of microcirculatory alterations. IDF is the technical successor of sidestream dark field imaging (SDF), currently the most used device for microcirculatory measurements. In (pre)term neonates the redu...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-015-9708-5
更新日期:2015-10-01 00:00:00
abstract::The goal of this study was to evaluate the risk factors associated with positioning-related SSEP changes (PRSC). The study investigated the association between 18 plausible risk factors and the occurrence of intraoperative PRSC. Risk factors investigated included demographic variables, comorbidities, and procedure rel...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-018-0148-x
更新日期:2019-04-01 00:00:00
abstract::The recently developed technique for measuring cutaneous mitochondrial oxygen tension (mitoPO2) by means of the Protoporphyrin IX-Triplet State Lifetime Technique (PpIX-TSLT) provides new opportunities for assessing mitochondrial function in vivo. The aims of this work were to study whether cutaneous mitochondrial mea...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-014-9628-9
更新日期:2015-08-01 00:00:00
abstract:OBJECTIVES:The purpose of this paper is to increase awareness of electrode burns that occur in the operating room (OR), to discuss their causes, warning signs, and methods that may reduce their occurrence. Two general sources of electrical burns are described: 1) Excessive radio-frequency current density usually origin...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1023/b:jocm.0000025254.73456.db
更新日期:2004-02-01 00:00:00
abstract::The eye lens is one of the most sensitive organs for radiation injury and exposure might lead to radiation induced cataract. Eye lens dosimetry in anesthesiology has been published in few clinical trials and an active debate about the causality of radiation induced cataract is still ongoing. Recently, the Internationa...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-016-9857-1
更新日期:2017-04-01 00:00:00
abstract::In this paper is presented a brief state of art regarding the multivariable formulation for controlling the depth of anaesthesia by means of two intravenously administrated drugs, i.e. propofol and remifentanil. In a feasibility study of determining a suitable variable to quantify analgesia levels in patients undergoi...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-013-9535-5
更新日期:2014-12-01 00:00:00
abstract:OBJECTIVES:The application of sighs during baseline ventilation was found to improve alveolar recruitment and oxygenation in patients with acute respiratory distress syndrome (ARDS). The present investigation evaluates if respiratory mechanics can be modified by a sigh. METHODS:Ten consecutive patients with acute lung...
journal_title:Journal of clinical monitoring and computing
pub_type: 临床试验,杂志文章
doi:10.1007/s10877-006-9028-x
更新日期:2006-08-01 00:00:00
abstract::Amidst controversy about methodology and safety, intraoperative neurophysiology has entered a new era of increasingly routine transcranial and direct electrical brain stimulation for motor evoked potential (MEP) monitoring. Based on literature review and illustrative clinical experience, this tutorial aims to present ...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章,评审
doi:10.1007/s10877-006-9033-0
更新日期:2006-10-01 00:00:00
abstract::To date, most of the studies on safety and efficacy of supraglottic airway devices were done in Caucasian patients, and the results may not be extrapolated to Asian patients due to the different airway anatomy. We conducted this study to compare Supreme™ LMA (SLMA) and Proseal™ LMA (PLMA) size 1.5 in anaesthetized chi...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章,随机对照试验
doi:10.1007/s10877-018-0109-4
更新日期:2018-12-01 00:00:00
abstract::The purpose of this concept study was to investigate the possibility of automatic mean arterial pressure (MAP) regulation in a porcine heart-beating brain death (BD) model. Hemodynamic stability of BD donors is necessary for maintaining acceptable quality of donated organs for transplantation. Manual stabilization is ...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-017-0033-z
更新日期:2018-06-01 00:00:00
abstract::Total shoulder arthroplasty (TSA) is typically performed in the beach-chair position. Maintenance of adequate mean arterial pressure is required to provide appropriate cerebral perfusion pressure and prevent cerebral ischemia. Placement of an arterial line to facilitate invasive monitoring is discretionary, based on c...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-016-9939-0
更新日期:2017-10-01 00:00:00
abstract::To compare the newborn infant parasympathetic evaluation system (NIPE) scores with a validated clinical scale using two different nebulizers in children with bronchiolitis admitted to a PICU. Comfort was evaluated using the COMFORT-behavior scale (CBS) before (T1), during (T2) and after (T3) each nebulization. In orde...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章,随机对照试验
doi:10.1007/s10877-019-00268-1
更新日期:2019-10-01 00:00:00
abstract::Recent advances in technology have brought many kinds of monitoring devices into the operating room (OR). The information gathered by monitors can be channeled to the operating ward information system via a local area network (LAN). Connecting patients to monitors and monitors to the LAN, however, requires a large num...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1023/a:1009911208828
更新日期:2000-01-01 00:00:00
abstract::Pulse contour analysis techniques are used for beat-to-beat tracking of cardiac output in critically ill patients. However, an adequate pulse pressure waveform signal and identification of the appropriate (i.e. systolic) part of the waveform by the monitor are crucial for correct calculation of continuous cardiac outp...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-013-9470-5
更新日期:2013-10-01 00:00:00
abstract::To develop and validate a mathematical model for predicting intracranial pressure (ICP) noninvasively using phase-contrast cine MRI (PC-MRI). We performed a retrospective analysis of PC-MRI from patients with communicating hydrocephalus (n = 138). The patients were recruited from Shenzhen Second People's Hospital betw...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-020-00598-5
更新日期:2020-10-01 00:00:00