Increases in voltage may produce false-negatives when using transcranial motor evoked potentials to detect an isolated nerve root injury.

Abstract:

OBJECTIVE:Transcranial Motor Evoked Potentials (TcMEPs) are sometimes used during lumbar spine surgery in order to detect and prevent an intraoperative nerve root injury. Typically, a fixed stimulus is applied, and one monitors for changes in response amplitude from several myotomes. Increased stimulating voltage may or may not alter the response after an acute injury. METHODS:We suture ligated the dominant root innervating the tibialis anterior (TA) muscle in 7 experiments in swine monitored with TcMEPs. Injury to the root was confirmed by an increase in threshold current needed to evoke an EMG response in the TA (from 0.32 ± 0.10 to 2.3 ± 0.9 mA, P < 0.01). We recorded TcMEPs at baseline, after injury, and with incremental 25 V increases in stimulation up to 100 V. RESULTS:After ligation, mean TcMEP amplitude in the TA decreased by 56% from baseline (P < 0.01). Adding voltage progressively restored mean amplitude to within 17% of baseline, but with wide variability in the response. In 1 experiment, there was no augmentation; 3 studies showed partial improvement toward baseline; and in 3 studies, the amplitude was augmented to levels above baseline. CONCLUSION:An acute nerve root injury may be detected by TcMEP monitoring. However, if the stimulating voltage is increased after injury, the response may or may not be affected. In complex spine procedures, adjustments to TcMEP stimulating parameters are often needed to maintain reproducible responses. However, if these changes are made during a period where injury might occur, this could mask the changes and lead to a false-negative interpretation.

journal_name

J Clin Monit Comput

authors

Lyon R,Gibson A,Burch S,Lieberman J

doi

10.1007/s10877-010-9269-6

subject

Has Abstract

pub_date

2010-12-01 00:00:00

pages

441-8

issue

6

eissn

1387-1307

issn

1573-2614

journal_volume

24

pub_type

杂志文章
  • Comparison of cardiac output determined by bioimpedance and bioreactance methods at rest and during exercise.

    abstract::Bioreactance is a novel non-invasive method for cardiac output measurement that involves the analysis of blood flow-dependent changes in the phase shifts of electrical currents applied across the chest. The present study (1) compared resting and exercise cardiac outputs determined by bioreactance and bioimpedance meth...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-012-9334-4

    authors: Jakovljevic DG,Moore S,Hallsworth K,Fattakhova G,Thoma C,Trenell MI

    更新日期:2012-04-01 00:00:00

  • Comparison of an ultrasound-guided technique versus a landmark-guided technique for internal jugular vein cannulation.

    abstract::Central venous cannulation is a commonly preformed procedure in many branches of medicine, particularly in anaesthesia and intensive care medicine. The purpose of this study was to compare the landmark-guided technique to the ultrasound-guided technique for internal jugular vein cannulation in cardiovascular surgery p...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10877-014-9585-3

    authors: Dolu H,Goksu S,Sahin L,Ozen O,Eken L

    更新日期:2015-02-01 00:00:00

  • Pulmonary air embolism.

    abstract::Pulmonary air embolism is a well-known consequence of surgery, trauma, diving, and aviation. This article reviews the physiological effects, means of detection and methods of prevention and treatment of pulmonary air embolism. The primary physiological effects are elevated pulmonary artery pressures, increased ventila...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,评审

    doi:10.1023/a:1011455701892

    authors: Souders JE

    更新日期:2000-01-01 00:00:00

  • Comparison between pulse wave velocities measured using Complior and measured using Biopac.

    abstract::Arterial stiffness is a reliable prognostic parameter for cardiovascular diseases. The effect of change in arterial stiffness can be measured by the change of the pulse wave velocity (PWV). The Complior system is widely used to measure PWV between the carotid and radial arteries by means of piezoelectric clips placed ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-018-0165-9

    authors: van Velzen MHN,Stolker RJ,Loeve AJ,Niehof SP,Mik EG

    更新日期:2019-04-01 00:00:00

  • SNAP II versus BIS VISTA monitor comparison during general anesthesia.

    abstract:INTRODUCTION:Effectively monitoring the level of consciousness during general anesthesia is clinically beneficial to both the patient and the physician. An electroencephalogram (EEG)-based level-of-consciousness monitor can help minimize intraoperative awareness as well as the effects of over-sedation. In this study, w...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-010-9246-0

    authors: Hrelec C,Puente E,Bergese S,Dzwonczyk R

    更新日期:2010-08-01 00:00:00

  • Bilobed splitting of median nerve somatosensory evoked p14 potential under deep hypothermia.

    abstract:OBJECTIVE:To further elucidate temperature related changes in subcortical components of somatosensory evoked potentials (SEP) in intraoperative monitoring. METHODS:Intraoperative monitoring of subcortical median nerve SEP under deep hypothermia is described in a patient undergoing intracranial giant aneurysm surgery. ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1020792729242

    authors: Wagner W

    更新日期:2002-04-01 00:00:00

  • Atypical "tails-up" capnograph due to breach in the sampling tube of side-stream capnometer.

    abstract:OBJECTIVE:An atypical "tails-up" capnograph pattern was noticed in a patient during the use of an accidentally crushed sampling tube with a slit-like hole. We investigated the mechanics involved in the observed capnograph pattern. METHODS:Forty consenting ASA I patients of both sexes presenting for tonsillectomy were ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009990210114

    authors: Tripathi M,Pandey M

    更新日期:2000-01-01 00:00:00

  • A fully automated algorithm for the determination of respiratory rate from the photoplethysmogram.

    abstract:OBJECTIVE:To determine if an automatic algorithm using wavelet analysis techniques can be used to reliably determine respiratory rate from the photoplethysmogram (PPG). METHODS:Photoplethysmograms were obtained from 12 spontaneously breathing healthy adult volunteers. Three related wavelet transforms were automaticall...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-005-9007-7

    authors: Leonard PA,Douglas JG,Grubb NR,Clifton D,Addison PS,Watson JN

    更新日期:2006-02-01 00:00:00

  • Functional residual capacity measurement during tracheal gas insufflation.

    abstract:OBJECTIVE:Tracheal gas insufflation (TGI) is considered an adjunctive method to enhance carbon dioxide elimination during permissive hypercapnia in patients with acute respiratory distress syndrome. Due to increasing tidal volume and/or expiratory resistance, TGI may cause intrinsic PEEP (PEEPi), and may lessen the adv...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009998100819

    authors: Fujino Y,Nishimura M,Hirao O,Taenaka N,Yoshiya I

    更新日期:1998-05-01 00:00:00

  • Changes in cerebral and renal oxygenation during laparoscopic pyloromyotomy.

    abstract::Although a laparoscopic approach may be preferred over open procedures for abdominal surgery, there are limited data on the effect of laparoscopic procedures on cerebral and renal oxygenation in neonates and young infants. Here, we evaluated the effect in neonates and infants. In this two-center prospective observatio...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00356-2

    authors: Kamata M,Hakim M,Walia H,Tumin D,Tobias JD

    更新日期:2020-08-01 00:00:00

  • GNARE: automated system for high-throughput genome analysis with grid computational backend.

    abstract::Recent progress in genomics and experimental biology has brought exponential growth of the biological information available for computational analysis in public genomics databases. However, applying the potentially enormous scientific value of this information to the understanding of biological systems requires comput...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-005-3463-y

    authors: Sulakhe D,Rodriguez A,D'Souza M,Wilde M,Nefedova V,Foster I,Maltsev N

    更新日期:2005-10-01 00:00:00

  • The units of measurement of the ventricular stroke work: a review study.

    abstract:BACKGROUND:The ventricular stroke work refers to the work done by the left or right ventricle to eject the volume of blood during one cardiac cycle, called stroke volume. Sarnoff and Berglund were one of the first to calculate the stroke work from the pressure volume diagram in 1954. However, they published a wrong uni...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,评审

    doi:10.1007/s10877-010-9234-4

    authors: Schramm W

    更新日期:2010-06-01 00:00:00

  • Transoesophageal Doppler monitoring for fluid and hemodynamic treatment during lung surgery.

    abstract:INTRODUCTION:Patients undergoing lung resection are vulnerable to fluid overhydration. Recently, goal-directed fluid therapy using transoesophageal Doppler monitoring (TDM) has been shown to improve postoperative clinical outcome. The aim of this study was to assess the feasibility of TDM during open-chest procedures f...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-008-9144-x

    authors: Diaper J,Ellenberger C,Villiger Y,Robert J,Tschopp JM,Licker M

    更新日期:2008-10-01 00:00:00

  • Intraoperative electrode burns.

    abstract:OBJECTIVES:The purpose of this paper is to increase awareness of electrode burns that occur in the operating room (OR), to discuss their causes, warning signs, and methods that may reduce their occurrence. Two general sources of electrical burns are described: 1) Excessive radio-frequency current density usually origin...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/b:jocm.0000025254.73456.db

    authors: Russell MJ,Gaetz M

    更新日期:2004-02-01 00:00:00

  • Estimation of pulse pressure variation and cardiac output in patients having major abdominal surgery: a comparison between a mobile application for snapshot pulse wave analysis and invasive pulse wave analysis.

    abstract::Pulse pressure variation (PPV) and cardiac output (CO) can guide perioperative fluid management. Capstesia (Galenic App, Vitoria-Gasteiz, Spain) is a mobile application for snapshot pulse wave analysis (PWAsnap) and estimates PPV and CO using pulse wave analysis of a snapshot of the arterial blood pressure waveform di...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00572-1

    authors: Hoppe P,Gleibs F,Briesenick L,Joosten A,Saugel B

    更新日期:2020-08-04 00:00:00

  • Non-invasive bladder volume measurement for the prevention of postoperative urinary retention: validation of two ultrasound devices in a clinical setting.

    abstract::Ultrasound scanning of bladder volume is used for prevention of postoperative urinary retention (POUR). Accurate assessment of bladder volume is needed to allow clinical decision-making regarding the need for postoperative catheterization. Two commonly used ultrasound devices, the BladderScan® BVI 9400 and the newly r...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-018-0123-6

    authors: Brouwer TA,van den Boogaard C,van Roon EN,Kalkman CJ,Veeger N

    更新日期:2018-12-01 00:00:00

  • Characterization of respiratory compromise and the potential clinical utility of capnography in the post-anesthesia care unit: a blinded observational trial.

    abstract::The utility of capnography to detect early respiratory compromise in surgical patients after anesthesia is unclear due to limited prospective data. The purpose of this trial was to determine the frequency and duration of capnography-detected respiratory adverse events in the post-anesthesia care unit (PACU). In this p...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00333-9

    authors: Chung F,Wong J,Mestek ML,Niebel KH,Lichtenthal P

    更新日期:2020-06-01 00:00:00

  • Correlation between preoperative somatosensory evoked potentials and intraoperative neurophysiological monitoring in spinal cord tumors.

    abstract::Intraoperative neurophysiological monitoring (IONM) is widely used in spinal cord tumors (SCTs) removal surgery. This study mainly hypothesized that patients with prolonged latency of preoperative somatosensory evoked potentials (preSEPLat) would have more deteriorated intraoperative evoked potentials. Among 506 patie...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00584-x

    authors: Park J,Cho YE,Park M,Lee J,Kim D,Park YG

    更新日期:2020-09-29 00:00:00

  • Study of light transmission through gauze pad effected by blood or liquids to detect needle dislodgement.

    abstract:OBJECTIVE:Serious accidents during hemodialysis such as a large amount of blood loss are often caused by venous needle dislodgement. To develop a bleeding sensor based on a photo sensor for monitoring the needle sites, we studied effects of liquids and porcine blood on light transmission through a thin gauze pad with a...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-009-9206-8

    authors: Takeuchi A,Ishida K,Morohoshi Y,Shinbo T,Hirose M,Ikeda N

    更新日期:2010-02-01 00:00:00

  • Eye lens dosimetry in anesthesiology: a prospective study.

    abstract::The eye lens is one of the most sensitive organs for radiation injury and exposure might lead to radiation induced cataract. Eye lens dosimetry in anesthesiology has been published in few clinical trials and an active debate about the causality of radiation induced cataract is still ongoing. Recently, the Internationa...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-016-9857-1

    authors: Vaes B,Van Keer K,Struelens L,Schoonjans W,Nijs I,Vandevenne J,Van Poucke S

    更新日期:2017-04-01 00:00:00

  • Effects of prolonged ischemia on human skeletal muscle microcirculation as assessed by near-infrared spectroscopy.

    abstract::Near-infrared spectroscopy (NIRS) has been used to detect in vivo microvascular alterations by means of a vascular occlusion test. We sought to analyse by NIRS the microcirculatory profile of patients undergoing prolonged tourniquet-induced bloodless condition for extremity surgery, and compare the results with time o...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-016-9877-x

    authors: Tujjar O,De Gaudio AR,Tofani L,Di Filippo A

    更新日期:2017-06-01 00:00:00

  • Perioperative echocardiography-guided hemodynamic therapy in high-risk patients: a practical expert approach of hemodynamically focused echocardiography.

    abstract::The number of high-risk patients undergoing surgery is growing. To maintain adequate hemodynamic functioning as well as oxygen delivery to the vital organs (DO2) amongst this patient population, a rapid assessment of cardiac functioning is essential for the anesthesiologist. Pinpointing any underlying cardiovascular p...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,评审

    doi:10.1007/s10877-020-00534-7

    authors: Trauzeddel RF,Ertmer M,Nordine M,Groesdonk HV,Michels G,Pfister R,Reuter D,Scheeren TWL,Berger C,Treskatsch S

    更新日期:2020-05-26 00:00:00

  • EEG-derived pain threshold index for prediction of postoperative pain in patients undergoing laparoscopic urological surgery: a comparison with surgical pleth index.

    abstract::Recently a novel pain recognition indicator derived from electroencephalogram(EEG) signals, pain threshold index(PTI) has been developed. The aim of this study was to determine whether PTI can be used for prediction of postoperative acute pain while surgical pleth index(SPI) applied as control. Eighty patients undergo...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00604-w

    authors: Wang R,Deng Y,Zhou S,Zhang J

    更新日期:2020-10-12 00:00:00

  • Using physiological models and decision theory for selecting appropriate ventilator settings.

    abstract:OBJECTIVE:To present a decision support system for optimising mechanical ventilation in patients residing in the intensive care unit. METHODS:Mathematical models of oxygen transport, carbon dioxide transport and lung mechanics are combined with penalty functions describing clinical preference toward the goals and side...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-006-9049-5

    authors: Rees SE,Allerød C,Murley D,Zhao Y,Smith BW,Kjaergaard S,Thorgaard P,Andreassen S

    更新日期:2006-12-01 00:00:00

  • Bench test assessment of mainstream capnography during high frequency oscillatory ventilation.

    abstract::To assess the feasibility, stability and predictability of pCO2 measurement (PETCO2) using a main stream capnograph in a high frequency oscillatory ventilation circuit. A commercially available capnograph was mounted into a high frequency oscillatory ventilator patient circuit, adjustable CO2 flow was introduced into ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-013-9495-9

    authors: Hartdorff CM,van Heerde M,Markhorst DG

    更新日期:2014-02-01 00:00:00

  • Capnography to check the safety of Bain circuit.

    abstract::The test of the inner tube integrity is an important checklist prior to the safe use of Bain's breathing system. This is because the major concern with the use of Bain's circuit is the potential malfunctioning of the circuit due to avulsion of the inner fresh gas delivery tube at the machine end which will turn the ou...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-009-9212-x

    authors: Kataria S,Subramanyam R

    更新日期:2010-02-01 00:00:00

  • The impact of systemic vascular resistance on the accuracy of the FloTrac/Vigileo™ system in the perioperative period of cardiac surgery: a prospective observational comparison study.

    abstract::FloTrac/Vigileo™ system is based on arterial pressure waveform analysis arterial pressure-based CO (APCO). Therefore, systemic vascular resistance (SVR) can influence the accuracy of APCO. The purpose of this study is to evaluate the relationship between SVR and the accuracy of APCO. We managed 50 consecutive patients...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-013-9481-2

    authors: Sotomi Y,Iwakura K,Higuchi Y,Abe K,Yoshida J,Masai T,Fujii K

    更新日期:2013-12-01 00:00:00

  • Respiratory and non-respiratory sinus arrhythmia: implications for heart rate variability.

    abstract::The quantity of blood arriving at the left side of the heart oscillates throughout the breathing cycle due to the mechanics of breathing. Neurally regulated fluctuations in the length of the heart period act to dampen oscillations of the left ventricular stroke volume entering the aorta. We have reported that stroke v...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-011-9327-8

    authors: McMullen MK,Whitehouse JM,Shine G,Towell A

    更新日期:2012-02-01 00:00:00

  • Transcranial Doppler monitoring compared with invasive monitoring of intracranial pressure during acute intracranial hypertension.

    abstract:OBJECTIVE:To determine whether a simple transcanial Doppler waveform variable-pulsatility difference (systolic - diastolic blood flow velocity) can serve as a measure of critical changes in cerebral perfusion. METHODS:Thirteen pigs were anesthetized (anesthesia maintained with halothane) and ventilated to maintain nor...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009993232534

    authors: Sidi A,Messinger G,Mahla ME

    更新日期:1999-05-01 00:00:00

  • A motor evoked potential trending system may discriminate outcome: retrospective application with three cases.

    abstract::This report presents a method for tracking Motor Evoked Potential (MEP) amplitudes over the course of a case using a moving least squares linear regression (LSMAs). During a case, newly obtained MEP amplitudes are compared to those predicted by a just previous linear regression (least squares moving average or LSMA). ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-018-0181-9

    authors: Jasiukaitis P,Lyon R

    更新日期:2019-06-01 00:00:00