Eye lens dosimetry in anesthesiology: a prospective study.

Abstract:

:The eye lens is one of the most sensitive organs for radiation injury and exposure might lead to radiation induced cataract. Eye lens dosimetry in anesthesiology has been published in few clinical trials and an active debate about the causality of radiation induced cataract is still ongoing. Recently, the International Commission on Radiological Protection (ICRP) recommended a reduction in the annual dose limit for occupational exposure for the lens of the eye from 150 to 20 mSv, averaged over a period of 5 years, with the dose in a single year not exceeding 50 mSv. This prospective study investigated eye lens dosimetry in anesthesiology practice during a routine year of professional activity. The radiation exposure measured represented the exposure in a normal working schedule of a random anesthesiologist during 1 month and this cumulative eye lens dose was extrapolated to 1 year. Next, eye lens doses were measured in anesthesiology during neuro-embolisation procedures, radiofrequency ablations or vertebroplasty/kyphoplasty procedures. The eye lens doses are measured in terms of the dose equivalent H p(3) with the Eye-D dosimeter (Radcard, Poland) close to the right eye (on the temple). In 16 anesthesiologists, the estimated annual eye lens doses range from a minimum of 0.4 mSv to a maximum of 3.5 mSv with an average dose of 1.33 mSv. Next, eye lens doses were measured for nine neuro-embolisation procedures, ten radiofrequency ablations and six vertebroplasty/kyphoplasty procedures. Average eye lens doses of 77 ± 76 µSv for neuro-embolisations, 38 ± 34 µSv for cardiac ablations and 40 ± 44 µSv for vertebro-/kyphoplasty procedures were recorded. The maximum doses were respectively 264, 97 and 122 µSv. This study demonstrated that the estimated annual eye lens dose is well below the revised ICRP's limit of 20 mSv/year. However, we demonstrated high maximum and average doses during neuro-embolisation, cardiac ablation and vertebro-/kyphoplasty procedures. With radiation induced cataract being explained as a possible stochastic effect, without a threshold dose, anesthesiologists who regularly work in a radiological environment should remain vigilant and maintain radiation safety standards at all times. This includes adequately protective equipment (protection shields, apron, thyroid shield and leaded eye wear), keeping distance, routine monitoring and appropriate education.

journal_name

J Clin Monit Comput

authors

Vaes B,Van Keer K,Struelens L,Schoonjans W,Nijs I,Vandevenne J,Van Poucke S

doi

10.1007/s10877-016-9857-1

subject

Has Abstract

pub_date

2017-04-01 00:00:00

pages

303-308

issue

2

eissn

1387-1307

issn

1573-2614

pii

10.1007/s10877-016-9857-1

journal_volume

31

pub_type

杂志文章
  • Estimation of pulse pressure variation and cardiac output in patients having major abdominal surgery: a comparison between a mobile application for snapshot pulse wave analysis and invasive pulse wave analysis.

    abstract::Pulse pressure variation (PPV) and cardiac output (CO) can guide perioperative fluid management. Capstesia (Galenic App, Vitoria-Gasteiz, Spain) is a mobile application for snapshot pulse wave analysis (PWAsnap) and estimates PPV and CO using pulse wave analysis of a snapshot of the arterial blood pressure waveform di...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00572-1

    authors: Hoppe P,Gleibs F,Briesenick L,Joosten A,Saugel B

    更新日期:2020-08-04 00:00:00

  • Pulmonary air embolism.

    abstract::Pulmonary air embolism is a well-known consequence of surgery, trauma, diving, and aviation. This article reviews the physiological effects, means of detection and methods of prevention and treatment of pulmonary air embolism. The primary physiological effects are elevated pulmonary artery pressures, increased ventila...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,评审

    doi:10.1023/a:1011455701892

    authors: Souders JE

    更新日期:2000-01-01 00:00:00

  • Monitoring of intratidal lung mechanics: a Graphical User Interface for a model-based decision support system for PEEP-titration in mechanical ventilation.

    abstract::In mechanical ventilation, a careful setting of the ventilation parameters in accordance with the current individual state of the lung is crucial to minimize ventilator induced lung injury. Positive end-expiratory pressure (PEEP) has to be set to prevent collapse of the alveoli, however at the same time overdistension...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s10877-014-9562-x

    authors: Buehler S,Lozano-Zahonero S,Schumann S,Guttmann J

    更新日期:2014-12-01 00:00:00

  • A comparison of graphical and textual presentations of time series data to support medical decision making in the neonatal intensive care unit.

    abstract:OBJECTIVE:To compare expert-generated textual summaries of physiological data with trend graphs, in terms of their ability to support neonatal Intensive Care Unit (ICU) staff in making decisions when presented with medical scenarios. METHODS:Forty neonatal ICU staff were recruited for the experiment, eight from each o...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-005-0879-3

    authors: Law AS,Freer Y,Hunter J,Logie RH,McIntosh N,Quinn J

    更新日期:2005-06-01 00:00:00

  • Mathematical arterialisation of peripheral venous blood gas for obtainment of arterial blood gas values: a methodological validation study in the clinical setting.

    abstract::Arterial blood gas (ABG) analysis is an essential tool in the clinical assessment of acutely ill patients. Venous to arterial conversion (v-TAC), a mathematical method, has been developed recently to convert peripheral venous blood gas (VBG) values to arterialized VBG (aVBG) values. The aim of this study was to test t...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-018-0197-1

    authors: Lumholdt M,Damgaard KA,Christensen EF,Leutscher PDC

    更新日期:2019-08-01 00:00:00

  • Bi-spectral index guided closed-loop anaesthesia delivery system (CLADS) in pheochromocytoma.

    abstract:OBJECTIVES:Anaesthetic management of pheochromocytoma is far from satisfactory even though various techniques are available. Feasibility as well as safety of Bi-spectral Index (BIS)-guided closed-loop control of anaesthesia has been shown in various clinical settings. We evaluated the performance of BIS-guided closed-l...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-009-9181-0

    authors: Hegde HV,Puri GD,Kumar B,Behera A

    更新日期:2009-08-01 00:00:00

  • Simulating physiological interactions in a hybrid system of mathematical models.

    abstract::Mathematical models can be deployed to simulate physiological processes of the human organism. Exploiting these simulations, reactions of a patient to changes in the therapy regime can be predicted. Based on these predictions, medical decision support systems (MDSS) can help in optimizing medical therapy. An MDSS desi...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-013-9502-1

    authors: Kretschmer J,Haunsberger T,Drost E,Koch E,Möller K

    更新日期:2014-12-01 00:00:00

  • Patterns of intra-arterial blood pressure monitoring for patients undergoing total shoulder arthroplasty under general anesthesia: a retrospective analysis of 23,073 patients.

    abstract::Total shoulder arthroplasty (TSA) is typically performed in the beach-chair position. Maintenance of adequate mean arterial pressure is required to provide appropriate cerebral perfusion pressure and prevent cerebral ischemia. Placement of an arterial line to facilitate invasive monitoring is discretionary, based on c...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-016-9939-0

    authors: Gabriel RA,Beverly A,Dutton RP,Urman RD

    更新日期:2017-10-01 00:00:00

  • A graphical object display improves anesthesiologists' performance on a simulated diagnostic task.

    abstract:OBJECTIVE:This study tests the hypothesis that a graphical object display (a data display consisting of meaningful shapes) will affect the ability of anesthesiologists to perform a diagnostic task rapidly and correctly. The diagnostic tasks studied were recognition and differentiation of five etiologies of shock--anaph...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009914019889

    authors: Blike GT,Surgenor SD,Whalen K

    更新日期:1999-01-01 00:00:00

  • A fully automated algorithm for the determination of respiratory rate from the photoplethysmogram.

    abstract:OBJECTIVE:To determine if an automatic algorithm using wavelet analysis techniques can be used to reliably determine respiratory rate from the photoplethysmogram (PPG). METHODS:Photoplethysmograms were obtained from 12 spontaneously breathing healthy adult volunteers. Three related wavelet transforms were automaticall...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-005-9007-7

    authors: Leonard PA,Douglas JG,Grubb NR,Clifton D,Addison PS,Watson JN

    更新日期:2006-02-01 00:00:00

  • Partitioning the resistances along the vascular tree: effects of dobutamine and hypovolemia in piglets with an intact circulation.

    abstract:OBJECTIVE:We present a new physiological model that discriminated between changes in the systemic arterial and venous circulation. To test our model, we studied the effects of dobutamine and hypovolemia in intact pentabarbital-anesthetized piglets. METHODS:Aorta pressure (Pao), central venous pressure (Pcv), mean syst...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-010-9258-9

    authors: Geerts BF,Maas JJ,Aarts LP,Pinsky MR,Jansen JR

    更新日期:2010-10-01 00:00:00

  • Multi-parameter vital sign database to assist in alarm optimization for general care units.

    abstract::Continual vital sign assessment on the general care, medical-surgical floor is expected to provide early indication of patient deterioration and increase the effectiveness of rapid response teams. However, there is concern that continual, multi-parameter vital sign monitoring will produce alarm fatigue. The objective ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-015-9790-8

    authors: Welch J,Kanter B,Skora B,McCombie S,Henry I,McCombie D,Kennedy R,Soller B

    更新日期:2016-12-01 00:00:00

  • Comparison of cardiac output optimization with an automated closed-loop goal-directed fluid therapy versus non standardized manual fluid administration during elective abdominal surgery: first prospective randomized controlled trial.

    abstract::An intraoperative automated closed-loop system for goal-directed fluid therapy has been successfully tested in silico, in vivo and in a clinical case-control matching. This trial compared intraoperative cardiac output (CO) in patients managed with this closed-loop system versus usual practice in an academic medical ce...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10877-018-0106-7

    authors: Lilot M,Bellon A,Gueugnon M,Laplace MC,Baffeleuf B,Hacquard P,Barthomeuf F,Parent C,Tran T,Soubirou JL,Robinson P,Bouvet L,Vassal O,Lehot JJ,Piriou V

    更新日期:2018-12-01 00:00:00

  • Comparison of the use of AnaConDa® versus AnaConDa-S® during the post-operative period of cardiac surgery under standard conditions of practice.

    abstract::Changes have been made to the AnaConDa device (Sedana Medical, Stockholm, Sweden), decreasing its size to reduce dead space and carbon dioxide (CO2) retention. However, this also involves a decrease in the surface area of the activated carbon filter. The CO2 elimination and sevoflurane (SEV) reflection of the old devi...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00285-0

    authors: Marcos-Vidal JM,Merino M,González R,García C,Rey S,Pérez I

    更新日期:2020-02-01 00:00:00

  • Computerized tests to evaluate recovery of cognitive function after deep sedation with propofol and remifentanil for colonoscopy.

    abstract::The use of sedation for diagnostic procedures including gastrointestinal endoscopy is rapidly growing. Recovery of cognitive function after sedation is important because it would be important for most patients to resume safe, normal life soon after the procedure. Computerized tests have shown being accurate descriptor...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-018-0134-3

    authors: Borrat X,Ubre M,Risco R,Gambús PL,Pedroso A,Iglesias A,Fernandez-Esparrach G,Ginés À,Balust J,Martínez-Palli G

    更新日期:2019-02-01 00:00:00

  • Tight reservoir bag: the bag itself may be the culprit.

    abstract::Numerous possibilities exist which may cause obstruction to ventilation under anesthesia resulting in a tight reservoir bag with low compliance. We report an interesting case where a reservoir bag twisted around its own neck and resulted in a tight bag situation. The neck portion of the reservoir bag would be hidden f...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-010-9232-6

    authors: Umesh G,Jasvinder K

    更新日期:2010-06-01 00:00:00

  • Effects of PEEP on the relationship between tidal volume and total impedance change measured via electrical impedance tomography (EIT).

    abstract::Electrical impedance tomography (EIT) is used in lung physiology monitoring. There is evidence that EIT is linearly associated with global tidal volume (VT) in clinically healthy patients where no positive end-expiratory pressure (PEEP) is applied. This linearity has not been challenged by altering lung conditions. Th...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-021-00651-x

    authors: Brabant O,Crivellari B,Hosgood G,Raisis A,Waldmann AD,Auer U,Adler A,Smart L,Laurence M,Mosing M

    更新日期:2021-01-25 00:00:00

  • Monitoring the microcirculation.

    abstract::One of the main goals of hemodynamic support is to preserve tissue perfusion. However issue perfusion is related more to microvascular perfusion than aortic blood flow. Monitoring the microcirculation has long been difficult. Recent technologic advances have made feasible monitoring of the microcirculation at bedside ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,评审

    doi:10.1007/s10877-012-9383-8

    authors: De Backer D,Donadello K,Cortes DO

    更新日期:2012-10-01 00:00:00

  • Dynamic prediction of the need for renal replacement therapy in intensive care unit patients using a simple and robust model.

    abstract::We aimed at identifying a model that dynamically predicts future need for renal replacement therapy (RRT) in intensive care unit (ICU) patients and can easily be implemented for online monitoring at the bedside. 7290 interdisciplinary ICU admissions were investigated. Patients with <3 days of stay or RRT in the first ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-015-9814-4

    authors: Erdfelder F,Grigutsch D,Hoeft A,Reider E,Matot I,Zenker S

    更新日期:2017-02-01 00:00:00

  • Diagnostic accuracy of stroke volume variation measured with uncalibrated arterial waveform analysis for the prediction of fluid responsiveness in patients with impaired left ventricular function: a prospective, observational study.

    abstract::Uncalibrated arterial waveform analysis enables dynamic preload assessment in a minimally invasive fashion. Evidence about the validity of the technique in patients with impaired left ventricular function is scarce, while adequate cardiac preload assessment would be of great value in these patients. The aim of this st...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-015-9743-2

    authors: Montenij LJ,Sonneveld JP,Nierich AP,Buhre WF,de Waal EE

    更新日期:2016-08-01 00:00:00

  • Prediction of difficult laryngoscopy using spirometry: a pilot study.

    abstract::Prediction of difficult laryngoscopy is still the uncovered secret of anesthetic practice. This pilot study is aimed to assess the efficacy of spirometry measurements in predicting difficult laryngoscopy compared with conventional airway assessment techniques. We enrolled 202 adults, ages 18-40 years, with an American...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-016-9961-2

    authors: Dogru S,Karaman T,Sahin A,Tapar H,Karaman S,Arici S,Suren M,Kaya Z,Somuk BT

    更新日期:2017-12-01 00:00:00

  • Detection of intratracheal accumulation of thick secretions by using continuous monitoring of respiratory acoustic spectrum: a preliminary analysis.

    abstract::The accumulation of tracheobronchial secretions may contribute to a deterioration in pulmonary function and its early detection is important. In this study, we analyzed the respiratory sound spectrum in patients with intratracheal secretion, and compared acoustic characteristics before and after therapeutic endotrache...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00359-z

    authors: Moon YJ,Bechtel AJ,Kim SH,Kim JW,Thiele RH,Blank RS

    更新日期:2020-08-01 00:00:00

  • Surrogate indices of aortic peak systolic velocity variation to monitor fluid responsiveness in pediatric non-cardiac surgery: a prospective observational study.

    abstract::Aortic peak systolic velocity variation (ΔVpeakAo) is a reliable dynamic indicator of preload in mechanically ventilated children. However, easily measurable alternative parameters like carotid peak systolic velocity variation (ΔVpeakCa) and suprasternal peak systolic velocity variation (ΔVpeakSs) are not well evaluat...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00431-8

    authors: Niyogi SG,Sen IM,Jayant A,Mandal B,Bhardwaj N,Yaddanapudi S,Mathew P

    更新日期:2020-12-01 00:00:00

  • Right ventricular function in late-onset Pompe disease.

    abstract::Pompe's disease is a glycogen storage disease (type II) characterized by inherited autosomal recessive transmission. The right ventricular (RV) function is a determinant parameter of clinical outcome in patients with heart failure. We sought to characterize the RV function using Doppler-echocardiography completed by D...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-014-9551-0

    authors: Fayssoil A,Nardi O,Annane D,Orlikowski D

    更新日期:2014-08-01 00:00:00

  • Machine learning applied to multi-sensor information to reduce false alarm rate in the ICU.

    abstract::Studies reveal that the false alarm rate (FAR) demonstrated by intensive care unit (ICU) vital signs monitors ranges from 0.72 to 0.99. We applied machine learning (ML) to ICU multi-sensor information to imitate a medical specialist in diagnosing patient condition. We hypothesized that applying this data-driven approa...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00307-x

    authors: Hever G,Cohen L,O'Connor MF,Matot I,Lerner B,Bitan Y

    更新日期:2020-04-01 00:00:00

  • Functional residual capacity measurement during tracheal gas insufflation.

    abstract:OBJECTIVE:Tracheal gas insufflation (TGI) is considered an adjunctive method to enhance carbon dioxide elimination during permissive hypercapnia in patients with acute respiratory distress syndrome. Due to increasing tidal volume and/or expiratory resistance, TGI may cause intrinsic PEEP (PEEPi), and may lessen the adv...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009998100819

    authors: Fujino Y,Nishimura M,Hirao O,Taenaka N,Yoshiya I

    更新日期:1998-05-01 00:00:00

  • Does the EEG during isoflurane/alfentanil anesthesia differ from linear random data?

    abstract:OBJECTIVE:Bispectral analysis of the electroencephalogram (EEG) has been used to monitor depth of anesthesia. In the majority of publications this has been done using the so called Bispectral (BIS) Index. The exact relation of this index to bispectral quantities like the bispectrum and its normalized version the bicohe...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1026284321451

    authors: Schwilden H,Jeleazcov C

    更新日期:2002-12-01 00:00:00

  • Monitoring of breathing phases using a bioacoustic method in healthy awake subjects.

    abstract:OBJECTIVE:To test the ability of a microphone recording system, located distal to the respiratory outflow tract, to track the timing of the inspiratory and expiratory phases of breathing in awake healthy subjects. METHODS:Fifteen subjects participated. Breath sounds were recorded using a microphone embedded in a face ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10877-011-9307-z

    authors: Alshaer H,Fernie GR,Bradley TD

    更新日期:2011-10-01 00:00:00

  • Validation of a photoplethysmography device for detection of obstructive sleep apnea in the perioperative setting.

    abstract::Obstructive sleep apnea (OSA) is a risk factor for perioperative complications, but many OSA patients present undiagnosed. While polysomnography (PSG) is the "gold standard" for diagnosis, its application is technology-intense, time-consuming, expensive, and requires specialists, often delaying surgery. Thus, miniatur...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-018-0151-2

    authors: Faßbender P,Haddad A,Bürgener S,Peters J

    更新日期:2019-04-01 00:00:00

  • The comparison of the technical parameters in endotracheal intubation devices: the Cmac, the Vividtrac, the McGrath Mac and the Kingvision.

    abstract::Currently, there are plenty of videolaryngoscopes that appear on the market. They have different specifications. Some of these features favor the fact that they are more suited for educational purposes of future operators and others can be characterized with an excellent clinical use. In this study we compared four ty...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-015-9727-2

    authors: Cierniak M,Timler D,Wieczorek A,Sekalski P,Borkowska N,Gaszynski T

    更新日期:2016-08-01 00:00:00