Tight reservoir bag: the bag itself may be the culprit.

Abstract:

:Numerous possibilities exist which may cause obstruction to ventilation under anesthesia resulting in a tight reservoir bag with low compliance. We report an interesting case where a reservoir bag twisted around its own neck and resulted in a tight bag situation. The neck portion of the reservoir bag would be hidden from the view of anesthesiologists in head and neck surgery and hence it is easier to miss early recognition of the twist. We caution all anesthesiologists using the disposable modified Jackson-Rees breathing system to be aware of such an eventuality. We also urge the manufacturer to consider strengthening the neck of the reservoir bag by improving the quality of the material used for its construction.

journal_name

J Clin Monit Comput

authors

Umesh G,Jasvinder K

doi

10.1007/s10877-010-9232-6

subject

Has Abstract

pub_date

2010-06-01 00:00:00

pages

189-90

issue

3

eissn

1387-1307

issn

1573-2614

journal_volume

24

pub_type

杂志文章
  • Transoesophageal Doppler monitoring for fluid and hemodynamic treatment during lung surgery.

    abstract:INTRODUCTION:Patients undergoing lung resection are vulnerable to fluid overhydration. Recently, goal-directed fluid therapy using transoesophageal Doppler monitoring (TDM) has been shown to improve postoperative clinical outcome. The aim of this study was to assess the feasibility of TDM during open-chest procedures f...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-008-9144-x

    authors: Diaper J,Ellenberger C,Villiger Y,Robert J,Tschopp JM,Licker M

    更新日期:2008-10-01 00:00:00

  • Cardioplegia and ventricular late potentials in cardiac surgical patients.

    abstract:BACKGROUND AND OBJECTIVE:Ventricular late potentials (LP) recording with signal-averaged electrocar- diogram allow identifying patients at risk of sudden death and ventricular tachycardia. Cardiac surgery with cardiopulmonary bypass (CPB) could predispose to the development of myocardial ischemia related to imperfect c...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-011-9305-1

    authors: Schütz N,Romand JA,Yanez ND,Treggiari MM,Bendjelid K

    更新日期:2011-08-01 00:00:00

  • Endotracheal tube inflation tubing defect: an unusual cause of intraoperative volume leak.

    abstract::Loss of endotracheal cuff pressure can lead to airway compromise and loss of volume delivery in mechanical ventilation requiring immediate intervention. A 40 years old male posted for bilateral interpositional arthroplasty was intubated nasally with 7.5 mm flexometallic endotracheal tube. In the intraoperative period ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 信件

    doi:10.1007/s10877-020-00607-7

    authors: Kumar A,Kumar A,Kumar N,Kumar A

    更新日期:2020-10-23 00:00:00

  • The incidence and interpretation of large differences in EIT-based measures for PEEP titration in ARDS patients.

    abstract::Positive end-expiratory pressure (PEEP) can be titrated by electrical impedance tomography (EIT). The aim of the present study was to examine the performance of different EIT measures during PEEP trials with the aim of identifying "optimum" PEEP and to provide possible interpretations of largely diverging results. Aft...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00396-8

    authors: Zhao Z,Lee LC,Chang MY,Frerichs I,Chang HT,Gow CH,Hsu YL,Möller K

    更新日期:2020-10-01 00:00:00

  • Heart rate variability analysis during central hypovolemia using wavelet transformation.

    abstract::Detection of hypovolemia prior to overt hemodynamic decompensation remains an elusive goal in the treatment of critically injured patients in both civilian and combat settings. Monitoring of heart rate variability has been advocated as a potential means to monitor the rapid changes in the physiological state of hemorr...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-013-9434-9

    authors: Ji SY,Belle A,Ward KR,Ryan KL,Rickards CA,Convertino VA,Najarian K

    更新日期:2013-06-01 00:00:00

  • Intraoperative electrode burns.

    abstract:OBJECTIVES:The purpose of this paper is to increase awareness of electrode burns that occur in the operating room (OR), to discuss their causes, warning signs, and methods that may reduce their occurrence. Two general sources of electrical burns are described: 1) Excessive radio-frequency current density usually origin...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/b:jocm.0000025254.73456.db

    authors: Russell MJ,Gaetz M

    更新日期:2004-02-01 00:00:00

  • Respiratory and non-respiratory sinus arrhythmia: implications for heart rate variability.

    abstract::The quantity of blood arriving at the left side of the heart oscillates throughout the breathing cycle due to the mechanics of breathing. Neurally regulated fluctuations in the length of the heart period act to dampen oscillations of the left ventricular stroke volume entering the aorta. We have reported that stroke v...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-011-9327-8

    authors: McMullen MK,Whitehouse JM,Shine G,Towell A

    更新日期:2012-02-01 00:00:00

  • Comparison of an ultrasound-guided technique versus a landmark-guided technique for internal jugular vein cannulation.

    abstract::Central venous cannulation is a commonly preformed procedure in many branches of medicine, particularly in anaesthesia and intensive care medicine. The purpose of this study was to compare the landmark-guided technique to the ultrasound-guided technique for internal jugular vein cannulation in cardiovascular surgery p...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10877-014-9585-3

    authors: Dolu H,Goksu S,Sahin L,Ozen O,Eken L

    更新日期:2015-02-01 00:00:00

  • BAEPs averaging analysis using autoregressive modelling.

    abstract:OBJECTIVE:The present paper introduces a new perspective on the classical ensemble averaging which can be useful to analyse the Brainstem Auditory Evoked Potentials (BAEPs). The analysis of the dynamics, related to the BAEP, is performed directly after its acquisition from the electroencephalogram (EEG). METHODS:The m...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/b:jocm.0000042919.04719.a7

    authors: Vannier E,Naït-Ali A

    更新日期:2004-06-01 00:00:00

  • Validation of a mathematical model for understanding intracranial pressure curve morphology.

    abstract::The physiology underlying the intracranial pressure (ICP) curve morphology is not fully understood. Recent research has suggested that the morphology could be dependent on arterial cerebral inflow and the physiological and pathophysiological properties of the intracranial cavity. If understood, the ICP curve could pro...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00342-8

    authors: Unnerbäck M,Ottesen JT,Reinstrup P

    更新日期:2020-06-01 00:00:00

  • A mathematical model for predicting intracranial pressure based on noninvasively acquired PC-MRI parameters in communicating hydrocephalus.

    abstract::To develop and validate a mathematical model for predicting intracranial pressure (ICP) noninvasively using phase-contrast cine MRI (PC-MRI). We performed a retrospective analysis of PC-MRI from patients with communicating hydrocephalus (n = 138). The patients were recruited from Shenzhen Second People's Hospital betw...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00598-5

    authors: Long J,Sun D,Zhou X,Huang X,Hu J,Xia J,Yang G

    更新日期:2020-10-01 00:00:00

  • Effects of PEEP on the relationship between tidal volume and total impedance change measured via electrical impedance tomography (EIT).

    abstract::Electrical impedance tomography (EIT) is used in lung physiology monitoring. There is evidence that EIT is linearly associated with global tidal volume (VT) in clinically healthy patients where no positive end-expiratory pressure (PEEP) is applied. This linearity has not been challenged by altering lung conditions. Th...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-021-00651-x

    authors: Brabant O,Crivellari B,Hosgood G,Raisis A,Waldmann AD,Auer U,Adler A,Smart L,Laurence M,Mosing M

    更新日期:2021-01-25 00:00:00

  • Mathematical arterialisation of peripheral venous blood gas for obtainment of arterial blood gas values: a methodological validation study in the clinical setting.

    abstract::Arterial blood gas (ABG) analysis is an essential tool in the clinical assessment of acutely ill patients. Venous to arterial conversion (v-TAC), a mathematical method, has been developed recently to convert peripheral venous blood gas (VBG) values to arterialized VBG (aVBG) values. The aim of this study was to test t...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-018-0197-1

    authors: Lumholdt M,Damgaard KA,Christensen EF,Leutscher PDC

    更新日期:2019-08-01 00:00:00

  • Simulating physiological interactions in a hybrid system of mathematical models.

    abstract::Mathematical models can be deployed to simulate physiological processes of the human organism. Exploiting these simulations, reactions of a patient to changes in the therapy regime can be predicted. Based on these predictions, medical decision support systems (MDSS) can help in optimizing medical therapy. An MDSS desi...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-013-9502-1

    authors: Kretschmer J,Haunsberger T,Drost E,Koch E,Möller K

    更新日期:2014-12-01 00:00:00

  • Accuracy and trending ability of hemoglobin measurement by the Pulse CO-Oximeter during vascular surgery.

    abstract::Real time information of Hb concentration can guide a tailored patient blood management. The study investigates the accuracy, precision and trending ability of the Pulse CO-Oximeter (SpHb) and blood gas analyzer in measuring the Hb concentration, compared to hematological analysis, in surgery at high risk of hemorrhag...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00337-5

    authors: De Rosa RC,Romano GM,Abbate R,Corcione A,De Robertis E

    更新日期:2020-06-01 00:00:00

  • Non-invasive cardiac output monitoring by aortic blood flow measurement with the Dynemo 3000.

    abstract::The operating principles and methods for the continuous determination of aortic blood flow (ABF) with the Dynemo 3000 system are described in detail. The system uses a novel transesophageal ultrasonic Echo-Doppler probe simultaneously to measure aortic diameter and blood flow velocity at the same anatomic level, in re...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009902517388

    authors: Boulnois JL,Pechoux T

    更新日期:2000-01-01 00:00:00

  • The American Society of Neurophysiological Monitoring position statements project.

    abstract::The American Society of Neurophysiological Monitoring (ASNM) is developing position statements aimed at assisting practitioners and others in making decisions regarding neurophysiological monitoring practice. This paper describes the procedures used in drafting these documents. ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-005-9000-1

    authors: Morledge DE,Stecker M

    更新日期:2006-02-01 00:00:00

  • The impact of systemic vascular resistance on the accuracy of the FloTrac/Vigileo™ system in the perioperative period of cardiac surgery: a prospective observational comparison study.

    abstract::FloTrac/Vigileo™ system is based on arterial pressure waveform analysis arterial pressure-based CO (APCO). Therefore, systemic vascular resistance (SVR) can influence the accuracy of APCO. The purpose of this study is to evaluate the relationship between SVR and the accuracy of APCO. We managed 50 consecutive patients...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-013-9481-2

    authors: Sotomi Y,Iwakura K,Higuchi Y,Abe K,Yoshida J,Masai T,Fujii K

    更新日期:2013-12-01 00:00:00

  • Transcranial Doppler monitoring compared with invasive monitoring of intracranial pressure during acute intracranial hypertension.

    abstract:OBJECTIVE:To determine whether a simple transcanial Doppler waveform variable-pulsatility difference (systolic - diastolic blood flow velocity) can serve as a measure of critical changes in cerebral perfusion. METHODS:Thirteen pigs were anesthetized (anesthesia maintained with halothane) and ventilated to maintain nor...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009993232534

    authors: Sidi A,Messinger G,Mahla ME

    更新日期:1999-05-01 00:00:00

  • Ergonomic automated anesthesia recordkeeper using a mobile touch screen with voice navigtion.

    abstract:OBJECTIVE:To develop an ergonomically designed computerized recordkeeping tool for anesthesiologists that allows the clinician to maintain visual contact with the patient while performing recordkeeping. METHODS:To simplify the human interface software, we developed two general use software components. All purpose menu...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009972223750

    authors: Sanjo Y,Yokoyama T,Sato S,Ikeda K,Nakajima R

    更新日期:1999-08-01 00:00:00

  • Novel hand-held device for exhaled nitric oxide-analysis in research and clinical applications.

    abstract::Changes in expired nitric oxide (NO) occur in airway inflammation and have proved to be important in the monitoring of inflammatory disease processes such as asthma. We set out to develop a novel hand-held NO-analyzer with a performance comparable to the present more costly and complex chemiluminescence instruments. T...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-005-1158-z

    authors: Hemmingsson T,Linnarsson D,Gambert R

    更新日期:2004-12-01 00:00:00

  • Ventilation monitoring during moderate sedation in GI patients.

    abstract::Sedation in locations outside the operating room (OR) is common. Guidelines for safe patient monitoring have been updated by the American Society of Anesthesiology to include monitoring of ventilation and/or carbon dioxide (CO2). Although technologies exist to monitor these variables, the quality and/or availability o...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-015-9809-1

    authors: Ebert TJ,Middleton AH,Makhija N

    更新日期:2017-02-01 00:00:00

  • GNARE: automated system for high-throughput genome analysis with grid computational backend.

    abstract::Recent progress in genomics and experimental biology has brought exponential growth of the biological information available for computational analysis in public genomics databases. However, applying the potentially enormous scientific value of this information to the understanding of biological systems requires comput...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-005-3463-y

    authors: Sulakhe D,Rodriguez A,D'Souza M,Wilde M,Nefedova V,Foster I,Maltsev N

    更新日期:2005-10-01 00:00:00

  • Capnography to check the safety of Bain circuit.

    abstract::The test of the inner tube integrity is an important checklist prior to the safe use of Bain's breathing system. This is because the major concern with the use of Bain's circuit is the potential malfunctioning of the circuit due to avulsion of the inner fresh gas delivery tube at the machine end which will turn the ou...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-009-9212-x

    authors: Kataria S,Subramanyam R

    更新日期:2010-02-01 00:00:00

  • Anti-decubitus bed mattress may interfere with cerebrovascular pressure reactivity measures due to induced ICP and ABP cyclic peaks.

    abstract::Severe traumatic brain injury (TBI) patients are monitored with continuous arterial blood pressure (ABP) and intracranial pressure (ICP). The pressure reactivity index (PRx) is a frequently used correlation coefficient between ABP and ICP to inform clinicians at the bedside about trends in global cerebrovascular press...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 信件

    doi:10.1007/s10877-020-00471-5

    authors: Jeanette T,Melisa B,Peter S,Marek C,Erta B,Ari E,Marcel A

    更新日期:2020-02-08 00:00:00

  • Comparison of cardiac output optimization with an automated closed-loop goal-directed fluid therapy versus non standardized manual fluid administration during elective abdominal surgery: first prospective randomized controlled trial.

    abstract::An intraoperative automated closed-loop system for goal-directed fluid therapy has been successfully tested in silico, in vivo and in a clinical case-control matching. This trial compared intraoperative cardiac output (CO) in patients managed with this closed-loop system versus usual practice in an academic medical ce...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10877-018-0106-7

    authors: Lilot M,Bellon A,Gueugnon M,Laplace MC,Baffeleuf B,Hacquard P,Barthomeuf F,Parent C,Tran T,Soubirou JL,Robinson P,Bouvet L,Vassal O,Lehot JJ,Piriou V

    更新日期:2018-12-01 00:00:00

  • The sound intensity and characteristics of variable-pitch pulse oximeters.

    abstract:OBJECTIVE:Various studies worldwide have found that sound levels in hospitals significantly exceed the World Health Organization (WHO) guidelines, and that this noise is associated with audible signals from various medical devices. The pulse oximeter is now widely used in health care; however the health effects associa...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-008-9125-0

    authors: Yamanaka H,Haruna J,Mashimo T,Akita T,Kinouchi K

    更新日期:2008-06-01 00:00:00

  • Ephedrine and phenylephrine induce opposite changes in cerebral and paraspinal tissue oxygen saturation, measured with near-infrared spectroscopy: a randomized controlled trial.

    abstract::While the effects of phenylephrine (PE) and ephedrine (E) on cerebral oxygen saturation (rScO2) already has been studied, the effect on paraspinal oxygen saturation (rSpsO2) is still unexplored. This study aims to assess the effect of PE and E on rScO2 and rSpsO2, measured with near-infrared spectroscopy. A randomized...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00328-6

    authors: Vanpeteghem CM,Bruneel BY,Lecoutere IM,De Hert SG,Moerman AT

    更新日期:2020-04-01 00:00:00

  • Focus on renal blood flow in mechanically ventilated patients with SARS-CoV-2: a prospective pilot study.

    abstract::Mechanically ventilated patients with ARDS due to the severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) seem particularly susceptible to AKI. Our hypothesis was that the renal blood flow could be more compromised in SARS-CoV-2 patients than in patients with "classical" ARDS. We compared the renal resistivit...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00633-5

    authors: Fogagnolo A,Grasso S,Dres M,Gesualdo L,Murgolo F,Morelli E,Ottaviani I,Marangoni E,Volta CA,Spadaro S

    更新日期:2021-01-01 00:00:00

  • Study of light transmission through gauze pad effected by blood or liquids to detect needle dislodgement.

    abstract:OBJECTIVE:Serious accidents during hemodialysis such as a large amount of blood loss are often caused by venous needle dislodgement. To develop a bleeding sensor based on a photo sensor for monitoring the needle sites, we studied effects of liquids and porcine blood on light transmission through a thin gauze pad with a...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-009-9206-8

    authors: Takeuchi A,Ishida K,Morohoshi Y,Shinbo T,Hirose M,Ikeda N

    更新日期:2010-02-01 00:00:00