Abstract:
:Numerous possibilities exist which may cause obstruction to ventilation under anesthesia resulting in a tight reservoir bag with low compliance. We report an interesting case where a reservoir bag twisted around its own neck and resulted in a tight bag situation. The neck portion of the reservoir bag would be hidden from the view of anesthesiologists in head and neck surgery and hence it is easier to miss early recognition of the twist. We caution all anesthesiologists using the disposable modified Jackson-Rees breathing system to be aware of such an eventuality. We also urge the manufacturer to consider strengthening the neck of the reservoir bag by improving the quality of the material used for its construction.
journal_name
J Clin Monit Computjournal_title
Journal of clinical monitoring and computingauthors
Umesh G,Jasvinder Kdoi
10.1007/s10877-010-9232-6subject
Has Abstractpub_date
2010-06-01 00:00:00pages
189-90issue
3eissn
1387-1307issn
1573-2614journal_volume
24pub_type
杂志文章abstract:INTRODUCTION:Patients undergoing lung resection are vulnerable to fluid overhydration. Recently, goal-directed fluid therapy using transoesophageal Doppler monitoring (TDM) has been shown to improve postoperative clinical outcome. The aim of this study was to assess the feasibility of TDM during open-chest procedures f...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-008-9144-x
更新日期:2008-10-01 00:00:00
abstract:BACKGROUND AND OBJECTIVE:Ventricular late potentials (LP) recording with signal-averaged electrocar- diogram allow identifying patients at risk of sudden death and ventricular tachycardia. Cardiac surgery with cardiopulmonary bypass (CPB) could predispose to the development of myocardial ischemia related to imperfect c...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-011-9305-1
更新日期:2011-08-01 00:00:00
abstract::Loss of endotracheal cuff pressure can lead to airway compromise and loss of volume delivery in mechanical ventilation requiring immediate intervention. A 40 years old male posted for bilateral interpositional arthroplasty was intubated nasally with 7.5 mm flexometallic endotracheal tube. In the intraoperative period ...
journal_title:Journal of clinical monitoring and computing
pub_type: 信件
doi:10.1007/s10877-020-00607-7
更新日期:2020-10-23 00:00:00
abstract::Positive end-expiratory pressure (PEEP) can be titrated by electrical impedance tomography (EIT). The aim of the present study was to examine the performance of different EIT measures during PEEP trials with the aim of identifying "optimum" PEEP and to provide possible interpretations of largely diverging results. Aft...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-019-00396-8
更新日期:2020-10-01 00:00:00
abstract::Detection of hypovolemia prior to overt hemodynamic decompensation remains an elusive goal in the treatment of critically injured patients in both civilian and combat settings. Monitoring of heart rate variability has been advocated as a potential means to monitor the rapid changes in the physiological state of hemorr...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-013-9434-9
更新日期:2013-06-01 00:00:00
abstract:OBJECTIVES:The purpose of this paper is to increase awareness of electrode burns that occur in the operating room (OR), to discuss their causes, warning signs, and methods that may reduce their occurrence. Two general sources of electrical burns are described: 1) Excessive radio-frequency current density usually origin...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1023/b:jocm.0000025254.73456.db
更新日期:2004-02-01 00:00:00
abstract::The quantity of blood arriving at the left side of the heart oscillates throughout the breathing cycle due to the mechanics of breathing. Neurally regulated fluctuations in the length of the heart period act to dampen oscillations of the left ventricular stroke volume entering the aorta. We have reported that stroke v...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-011-9327-8
更新日期:2012-02-01 00:00:00
abstract::Central venous cannulation is a commonly preformed procedure in many branches of medicine, particularly in anaesthesia and intensive care medicine. The purpose of this study was to compare the landmark-guided technique to the ultrasound-guided technique for internal jugular vein cannulation in cardiovascular surgery p...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章,随机对照试验
doi:10.1007/s10877-014-9585-3
更新日期:2015-02-01 00:00:00
abstract:OBJECTIVE:The present paper introduces a new perspective on the classical ensemble averaging which can be useful to analyse the Brainstem Auditory Evoked Potentials (BAEPs). The analysis of the dynamics, related to the BAEP, is performed directly after its acquisition from the electroencephalogram (EEG). METHODS:The m...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1023/b:jocm.0000042919.04719.a7
更新日期:2004-06-01 00:00:00
abstract::The physiology underlying the intracranial pressure (ICP) curve morphology is not fully understood. Recent research has suggested that the morphology could be dependent on arterial cerebral inflow and the physiological and pathophysiological properties of the intracranial cavity. If understood, the ICP curve could pro...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-019-00342-8
更新日期:2020-06-01 00:00:00
abstract::To develop and validate a mathematical model for predicting intracranial pressure (ICP) noninvasively using phase-contrast cine MRI (PC-MRI). We performed a retrospective analysis of PC-MRI from patients with communicating hydrocephalus (n = 138). The patients were recruited from Shenzhen Second People's Hospital betw...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-020-00598-5
更新日期:2020-10-01 00:00:00
abstract::Electrical impedance tomography (EIT) is used in lung physiology monitoring. There is evidence that EIT is linearly associated with global tidal volume (VT) in clinically healthy patients where no positive end-expiratory pressure (PEEP) is applied. This linearity has not been challenged by altering lung conditions. Th...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-021-00651-x
更新日期:2021-01-25 00:00:00
abstract::Arterial blood gas (ABG) analysis is an essential tool in the clinical assessment of acutely ill patients. Venous to arterial conversion (v-TAC), a mathematical method, has been developed recently to convert peripheral venous blood gas (VBG) values to arterialized VBG (aVBG) values. The aim of this study was to test t...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-018-0197-1
更新日期:2019-08-01 00:00:00
abstract::Mathematical models can be deployed to simulate physiological processes of the human organism. Exploiting these simulations, reactions of a patient to changes in the therapy regime can be predicted. Based on these predictions, medical decision support systems (MDSS) can help in optimizing medical therapy. An MDSS desi...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-013-9502-1
更新日期:2014-12-01 00:00:00
abstract::Real time information of Hb concentration can guide a tailored patient blood management. The study investigates the accuracy, precision and trending ability of the Pulse CO-Oximeter (SpHb) and blood gas analyzer in measuring the Hb concentration, compared to hematological analysis, in surgery at high risk of hemorrhag...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-019-00337-5
更新日期:2020-06-01 00:00:00
abstract::The operating principles and methods for the continuous determination of aortic blood flow (ABF) with the Dynemo 3000 system are described in detail. The system uses a novel transesophageal ultrasonic Echo-Doppler probe simultaneously to measure aortic diameter and blood flow velocity at the same anatomic level, in re...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1023/a:1009902517388
更新日期:2000-01-01 00:00:00
abstract::The American Society of Neurophysiological Monitoring (ASNM) is developing position statements aimed at assisting practitioners and others in making decisions regarding neurophysiological monitoring practice. This paper describes the procedures used in drafting these documents. ...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-005-9000-1
更新日期:2006-02-01 00:00:00
abstract::FloTrac/Vigileo™ system is based on arterial pressure waveform analysis arterial pressure-based CO (APCO). Therefore, systemic vascular resistance (SVR) can influence the accuracy of APCO. The purpose of this study is to evaluate the relationship between SVR and the accuracy of APCO. We managed 50 consecutive patients...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-013-9481-2
更新日期:2013-12-01 00:00:00
abstract:OBJECTIVE:To determine whether a simple transcanial Doppler waveform variable-pulsatility difference (systolic - diastolic blood flow velocity) can serve as a measure of critical changes in cerebral perfusion. METHODS:Thirteen pigs were anesthetized (anesthesia maintained with halothane) and ventilated to maintain nor...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1023/a:1009993232534
更新日期:1999-05-01 00:00:00
abstract:OBJECTIVE:To develop an ergonomically designed computerized recordkeeping tool for anesthesiologists that allows the clinician to maintain visual contact with the patient while performing recordkeeping. METHODS:To simplify the human interface software, we developed two general use software components. All purpose menu...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1023/a:1009972223750
更新日期:1999-08-01 00:00:00
abstract::Changes in expired nitric oxide (NO) occur in airway inflammation and have proved to be important in the monitoring of inflammatory disease processes such as asthma. We set out to develop a novel hand-held NO-analyzer with a performance comparable to the present more costly and complex chemiluminescence instruments. T...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-005-1158-z
更新日期:2004-12-01 00:00:00
abstract::Sedation in locations outside the operating room (OR) is common. Guidelines for safe patient monitoring have been updated by the American Society of Anesthesiology to include monitoring of ventilation and/or carbon dioxide (CO2). Although technologies exist to monitor these variables, the quality and/or availability o...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-015-9809-1
更新日期:2017-02-01 00:00:00
abstract::Recent progress in genomics and experimental biology has brought exponential growth of the biological information available for computational analysis in public genomics databases. However, applying the potentially enormous scientific value of this information to the understanding of biological systems requires comput...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-005-3463-y
更新日期:2005-10-01 00:00:00
abstract::The test of the inner tube integrity is an important checklist prior to the safe use of Bain's breathing system. This is because the major concern with the use of Bain's circuit is the potential malfunctioning of the circuit due to avulsion of the inner fresh gas delivery tube at the machine end which will turn the ou...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-009-9212-x
更新日期:2010-02-01 00:00:00
abstract::Severe traumatic brain injury (TBI) patients are monitored with continuous arterial blood pressure (ABP) and intracranial pressure (ICP). The pressure reactivity index (PRx) is a frequently used correlation coefficient between ABP and ICP to inform clinicians at the bedside about trends in global cerebrovascular press...
journal_title:Journal of clinical monitoring and computing
pub_type: 信件
doi:10.1007/s10877-020-00471-5
更新日期:2020-02-08 00:00:00
abstract::An intraoperative automated closed-loop system for goal-directed fluid therapy has been successfully tested in silico, in vivo and in a clinical case-control matching. This trial compared intraoperative cardiac output (CO) in patients managed with this closed-loop system versus usual practice in an academic medical ce...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章,随机对照试验
doi:10.1007/s10877-018-0106-7
更新日期:2018-12-01 00:00:00
abstract:OBJECTIVE:Various studies worldwide have found that sound levels in hospitals significantly exceed the World Health Organization (WHO) guidelines, and that this noise is associated with audible signals from various medical devices. The pulse oximeter is now widely used in health care; however the health effects associa...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-008-9125-0
更新日期:2008-06-01 00:00:00
abstract::While the effects of phenylephrine (PE) and ephedrine (E) on cerebral oxygen saturation (rScO2) already has been studied, the effect on paraspinal oxygen saturation (rSpsO2) is still unexplored. This study aims to assess the effect of PE and E on rScO2 and rSpsO2, measured with near-infrared spectroscopy. A randomized...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-019-00328-6
更新日期:2020-04-01 00:00:00
abstract::Mechanically ventilated patients with ARDS due to the severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) seem particularly susceptible to AKI. Our hypothesis was that the renal blood flow could be more compromised in SARS-CoV-2 patients than in patients with "classical" ARDS. We compared the renal resistivit...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-020-00633-5
更新日期:2021-01-01 00:00:00
abstract:OBJECTIVE:Serious accidents during hemodialysis such as a large amount of blood loss are often caused by venous needle dislodgement. To develop a bleeding sensor based on a photo sensor for monitoring the needle sites, we studied effects of liquids and porcine blood on light transmission through a thin gauze pad with a...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-009-9206-8
更新日期:2010-02-01 00:00:00