Mathematical arterialisation of peripheral venous blood gas for obtainment of arterial blood gas values: a methodological validation study in the clinical setting.

Abstract:

:Arterial blood gas (ABG) analysis is an essential tool in the clinical assessment of acutely ill patients. Venous to arterial conversion (v-TAC), a mathematical method, has been developed recently to convert peripheral venous blood gas (VBG) values to arterialized VBG (aVBG) values. The aim of this study was to test the validity of aVBG compared to ABG in an emergency department (ED) setting. Twenty ED patients were included in this study. ABG and three aVBG samples were collected from each patient. The aVBG samples were processed in three different ways to investigate appropriate sample handling. All VBG samples were arterialized using the v-TAC method. ABG and aVBG samples were compared using Lin's concordance correlation coefficient (CCC), Bland-Altman plots and misclassification analysis. Clinical acceptable threshold of aVBG value deviance from ABG values were ± 0.05 pH units, ± 0.88 kPa pCO2 and ± 0.88 kPa pO2. CCC revealed an agreement in pH and pCO2 parameters for both aVBG in comparison to ABG. In all aVBG samples, an overestimation of pO2 compared to ABG was observed. Bland-Altman plot revealed clinically acceptable mean difference and limits-of-agreement intervals between ABG and aVBG pH and pCO2, but not between ABG and aVBG pO2. Arterialization of VBG using v-TAC is a valid method for measuring pH and pCO2, but not for pO2. Larger clinical studies are required to evaluate the applicability of v-TAC in different patient subpopulations.

journal_name

J Clin Monit Comput

authors

Lumholdt M,Damgaard KA,Christensen EF,Leutscher PDC

doi

10.1007/s10877-018-0197-1

subject

Has Abstract

pub_date

2019-08-01 00:00:00

pages

733-740

issue

4

eissn

1387-1307

issn

1573-2614

pii

10.1007/s10877-018-0197-1

journal_volume

33

pub_type

杂志文章
  • Risk factors for positioning-related somatosensory evoked potential changes in 3946 spinal surgeries.

    abstract::The goal of this study was to evaluate the risk factors associated with positioning-related SSEP changes (PRSC). The study investigated the association between 18 plausible risk factors and the occurrence of intraoperative PRSC. Risk factors investigated included demographic variables, comorbidities, and procedure rel...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-018-0148-x

    authors: Melachuri SR,Balzer JR,Melachuri MK,Ninaci D,Anetakis K,Kaur J,Crammond DJ,Thirumala PD

    更新日期:2019-04-01 00:00:00

  • Continuous hemoglobin and plethysmography variability index monitoring can modify blood transfusion practice and is associated with lower mortality.

    abstract::To determine the effect of implementing an algorithm of fluid and blood administration based on continuous monitoring of hemoglobin (SpHb) and PVI (plethysmography variability index) on mortality and transfusion on a whole hospital scale. This single-center quality program compared transfusion at 48 h and mortality at...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00367-z

    authors: Cros J,Dalmay F,Yonnet S,Charpentier M,Tran-Van-Ho J,Renaudeau F,Drouet A,Guilbaut P,Marin B,Nathan N

    更新日期:2020-08-01 00:00:00

  • Comparison of cardiac output optimization with an automated closed-loop goal-directed fluid therapy versus non standardized manual fluid administration during elective abdominal surgery: first prospective randomized controlled trial.

    abstract::An intraoperative automated closed-loop system for goal-directed fluid therapy has been successfully tested in silico, in vivo and in a clinical case-control matching. This trial compared intraoperative cardiac output (CO) in patients managed with this closed-loop system versus usual practice in an academic medical ce...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10877-018-0106-7

    authors: Lilot M,Bellon A,Gueugnon M,Laplace MC,Baffeleuf B,Hacquard P,Barthomeuf F,Parent C,Tran T,Soubirou JL,Robinson P,Bouvet L,Vassal O,Lehot JJ,Piriou V

    更新日期:2018-12-01 00:00:00

  • The effect of variable arterial transducer level on the accuracy of pulse contour waveform-derived measurements in critically ill patients.

    abstract::We know that a 10 cm departure from the reference level of pressure transducer position is equal to a 7.5 mmHg change of invasive hemodynamic pressure monitoring in a fluid-filled system. However, the relationship between the site level of a variable arterial pressure transducer and the pulse contour-derived parameter...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-015-9756-x

    authors: He HW,Liu DW,Long Y,Wang XT,Zhao ML,Lai XL

    更新日期:2016-10-01 00:00:00

  • Infrared transmission of electronic information via LAN in the operating room.

    abstract::Recent advances in technology have brought many kinds of monitoring devices into the operating room (OR). The information gathered by monitors can be channeled to the operating ward information system via a local area network (LAN). Connecting patients to monitors and monitors to the LAN, however, requires a large num...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009911208828

    authors: Hagihira S,Takashina M,Mori T,Taenaka N,Mashimo T,Yoshiya I

    更新日期:2000-01-01 00:00:00

  • Oesophageal balloon calibration during pressure support ventilation: a proof of concept study.

    abstract::Oesophageal balloon calibration improves the oesophageal pressure (Pes) assessment during invasive controlled mechanical ventilation. The primary aim of the present investigation was to ascertain the feasibility of oesophageal balloon calibration during pressure support ventilation (PSV). Secondarily, the calibrated P...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00436-3

    authors: Cammarota G,Verdina F,Santangelo E,Lauro G,Boniolo E,Tarquini R,Spinelli E,Zanoni M,Garofalo E,Bruni A,Pesenti A,Della Corte F,Navalesi P,Vaschetto R,Mauri T

    更新日期:2020-12-01 00:00:00

  • Multi-parameter vital sign database to assist in alarm optimization for general care units.

    abstract::Continual vital sign assessment on the general care, medical-surgical floor is expected to provide early indication of patient deterioration and increase the effectiveness of rapid response teams. However, there is concern that continual, multi-parameter vital sign monitoring will produce alarm fatigue. The objective ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-015-9790-8

    authors: Welch J,Kanter B,Skora B,McCombie S,Henry I,McCombie D,Kennedy R,Soller B

    更新日期:2016-12-01 00:00:00

  • EEG-derived pain threshold index for prediction of postoperative pain in patients undergoing laparoscopic urological surgery: a comparison with surgical pleth index.

    abstract::Recently a novel pain recognition indicator derived from electroencephalogram(EEG) signals, pain threshold index(PTI) has been developed. The aim of this study was to determine whether PTI can be used for prediction of postoperative acute pain while surgical pleth index(SPI) applied as control. Eighty patients undergo...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00604-w

    authors: Wang R,Deng Y,Zhou S,Zhang J

    更新日期:2020-10-12 00:00:00

  • Optimization of alarms: a study on alarm limits, alarm sounds, and false alarms, intended to reduce annoyance.

    abstract::Alarms in the operating room remain a major source of annoyance and confusion. Nearly all alarms result from a transgression of certain alarm limits. We surveyed manufacturers at a major meeting of anesthesiologists for their default alarm limits. We also conducted a mail survey of anesthesiologists in the United Stat...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009992830942

    authors: Block FE Jr,Nuutinen L,Ballast B

    更新日期:1999-02-01 00:00:00

  • Monitoring the microcirculation.

    abstract::One of the main goals of hemodynamic support is to preserve tissue perfusion. However issue perfusion is related more to microvascular perfusion than aortic blood flow. Monitoring the microcirculation has long been difficult. Recent technologic advances have made feasible monitoring of the microcirculation at bedside ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,评审

    doi:10.1007/s10877-012-9383-8

    authors: De Backer D,Donadello K,Cortes DO

    更新日期:2012-10-01 00:00:00

  • A comparison of ventricular systolic function indices provided by VolumeView/EV1000™ and left ventricular ejection fraction by echocardiography among septic shock patients.

    abstract::The aim of this study was to compare the cardiac function index (CFI) and global ejection fraction (GEF) obtained by VolumeView/EV1000™, with the left ventricular ejection fraction (LVEF) by echocardiography in septic shock patients. A prospective observational study was conducted in a medical intensive care unit of a...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-018-0152-1

    authors: Nakwan N,Chichareon P,Khwannimit B

    更新日期:2019-04-01 00:00:00

  • The pressure exerted on the tongue during intubation with simultaneous cervical spine immobilisation: a comparison between four videolaryngoscopes and the Macintosh laryngoscope-a manikin study.

    abstract::Excessive pressures exerted on the tongue during intubation may be associated with serious complications and may make intubation more difficult. The aim of this study was to evaluate five different intubating devices in the hands of experienced anaesthetists during simulated conditions of reduced cervical spine mobili...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-017-0095-y

    authors: Aleksandrowicz D,Gaszyński T

    更新日期:2018-10-01 00:00:00

  • Effects of intraoperative positive end-expiratory pressure optimization on respiratory mechanics and the inflammatory response: a randomized controlled trial.

    abstract::Applying lung protective mechanical ventilation (LPV) during general anaesthesia even in patients with non-injured lungs is recommended. However, the effects of an individual PEEP-optimisation on respiratory mechanics, oxygenation and their potential correlation with the inflammatory response and postoperative complic...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00519-6

    authors: Ruszkai Z,Kiss E,László I,Bokrétás GP,Vizserálek D,Vámossy I,Surány E,Buzogány I,Bajory Z,Molnár Z

    更新日期:2020-05-09 00:00:00

  • Computerized recording of neuromuscular monitoring and the risk of residual paralysis at the time of extubation.

    abstract:OBJECTIVE:We tested whether a newly installed neuromuscular monitoring device (NMT) with a computerized anesthesia recording system, incorporated in all anesthesia stations, could enhance the commitment to objective neuromuscular monitoring in a teaching hospital anesthesia department. METHODS:After 6 months of famili...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-008-9135-y

    authors: Motamed C,Bourgain JL

    更新日期:2008-08-01 00:00:00

  • Pretreatment with glucose-insulin-potassium improves ventricular performances after coronary artery bypass surgery: a randomized controlled trial.

    abstract::Heart failure is the main cause of poor outcome following open heart surgery and experimental studies have demonstrated that glucose-insulin-potassium (GIK) infusion exerts cardioprotective effects by reducing myocardial ischemia-reperfusion injuries. This randomized controlled trial was designed to assess the effects...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00280-5

    authors: Licker M,Reynaud T,Garofano N,Sologashvili T,Diaper J,Ellenberger C

    更新日期:2020-02-01 00:00:00

  • Ventilator-associated pneumonia: current status and future recommendations.

    abstract:OBJECTIVE:Ventilator-associated pneumonia (VAP) is a common hazardous complication in ICU patients. The aim of the current review is to give an update on the current status and future recommendations for VAP prevention. METHODS:This article gives an updated review of the current literature on VAP. The first part brief...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,meta分析,评审

    doi:10.1007/s10877-010-9228-2

    authors: Efrati S,Deutsch I,Antonelli M,Hockey PM,Rozenblum R,Gurman GM

    更新日期:2010-04-01 00:00:00

  • Diagnostic accuracy of stroke volume variation measured with uncalibrated arterial waveform analysis for the prediction of fluid responsiveness in patients with impaired left ventricular function: a prospective, observational study.

    abstract::Uncalibrated arterial waveform analysis enables dynamic preload assessment in a minimally invasive fashion. Evidence about the validity of the technique in patients with impaired left ventricular function is scarce, while adequate cardiac preload assessment would be of great value in these patients. The aim of this st...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-015-9743-2

    authors: Montenij LJ,Sonneveld JP,Nierich AP,Buhre WF,de Waal EE

    更新日期:2016-08-01 00:00:00

  • Cardiac output measurement by pulse dye densitometry: comparison with pulmonary artery thermodilution in post-cardiac surgery patients.

    abstract:OBJECTIVE:Pulse-dye densitometry (PDD) could be a suitable, low-invasive alternative to thermodilution using a pulmonary artery catheter (PAC) for monitoring cardiac output. The aim of our study was to assess the reproducibility and validity of PDD compared to PAC-thermodilution. METHODS:In 43 post-cardiac surgery pat...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-005-6865-y

    authors: Kroon M,Groeneveld AB,Smulders YM

    更新日期:2005-12-01 00:00:00

  • Assessment of pulmonary mechanics in mechanical ventilation: effects of imprecise breath detection, phase shift and noise.

    abstract:OBJECTIVE:In mechanical ventilation, the assessment of pulmonary mechanics, mainly of total compliance (Crs), total resistance (Rrs), and intrinsic positive end-expiratory pressure (PEEPint), is clinically important. By using airway pressure (Paw) and flow (V'aw), the least squares fit (LSF) method allows the continuou...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1007457829405

    authors: Stegmaier PA,Zollinger A,Brunner JX,Pasch T

    更新日期:1998-02-01 00:00:00

  • Ventilation monitoring during moderate sedation in GI patients.

    abstract::Sedation in locations outside the operating room (OR) is common. Guidelines for safe patient monitoring have been updated by the American Society of Anesthesiology to include monitoring of ventilation and/or carbon dioxide (CO2). Although technologies exist to monitor these variables, the quality and/or availability o...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-015-9809-1

    authors: Ebert TJ,Middleton AH,Makhija N

    更新日期:2017-02-01 00:00:00

  • Diagnosis of anesthetic-induced upper airway obstruction in children using respiratory inductance plethysmography.

    abstract:OBJECTIVE:Upper airway obstruction is the most rapid and clinically relevant cause of hypoxia during sedation and anesthesia. This study was designed to determine if respiratory inductance plethysmography (RIP) could quantify the degree of upper airway obstruction caused by induction of general anesthesia. METHODS:RIP...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1021246119194

    authors: Litman RS,Kottra JA,Gallagher PR,Ward DS

    更新日期:2002-07-01 00:00:00

  • Characterization of respiratory compromise and the potential clinical utility of capnography in the post-anesthesia care unit: a blinded observational trial.

    abstract::The utility of capnography to detect early respiratory compromise in surgical patients after anesthesia is unclear due to limited prospective data. The purpose of this trial was to determine the frequency and duration of capnography-detected respiratory adverse events in the post-anesthesia care unit (PACU). In this p...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00333-9

    authors: Chung F,Wong J,Mestek ML,Niebel KH,Lichtenthal P

    更新日期:2020-06-01 00:00:00

  • Unconsciousness indication using time-domain parameters extracted from mid-latency auditory evoked potentials.

    abstract:OBJECTIVE:The mid-latency auditory evoked potential (MLAEP) has been used to indicate depth of anaesthesia, and is usually analysed in time-domain. This work compares three techniques: Wave Deformation Parameters (PDO), Auditory Evoked Potential Index (AEPidx) and an automatic Nb-wave latency estimator (Nb), in the ass...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 临床试验,杂志文章

    doi:10.1023/a:1024208827407

    authors: Cagy M,Infantosi AF

    更新日期:2002-08-01 00:00:00

  • Real-time two-dimensional and three-dimensional echocardiographic imaging of the thoracic spinal cord: a possible new window into the central neuraxis.

    abstract::Transesophageal echocardiography of the spine has been difficult to perform, and high-quality images have been difficult to obtain with earlier available technology. New capabilities in hardware and software reconstruction may allow more reliable clinical data to be obtained. We describe an initial successful attempt ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-014-9576-4

    authors: Feinglass NG,Clendenen SR,Shine TS,Martin AK,Greengrass RA

    更新日期:2015-02-01 00:00:00

  • Validation of an automated system for detecting ineffective triggering asynchronies during mechanical ventilation: a retrospective study.

    abstract::We compare the sensitivity and specificity of clinician visual waveform analysis against an automated system's waveform analysis in detecting ineffective triggering in mechanically ventilated intensive care unit patients when compared against a reference label set based upon analysis of respiratory muscle activity. El...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00442-5

    authors: Phan TS,Costa R,Haddad WM,Mullis JC,Price LT,Cason AD,Bailey JM,Gholami B

    更新日期:2020-12-01 00:00:00

  • EEG sources of noise in intraoperative somatosensory evoked potential monitoring during propofol anesthesia.

    abstract:OBJECTIVE:It was hypothesized that somato- sensory evoked potentials can be achieved faster by selective averaging during periods of low spontaneous electroen- cephalographic (EEG) activity. We analyzed the components of EEG that decrease the signal-to-noise ratio of somatosensory evoked potential (SEP) recordings duri...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-009-9188-6

    authors: Joutsen A,Puumala P,Lyytikäinen LP,Pajulo O,Etelämäki A,Eskola H,Jäntti V

    更新日期:2009-08-01 00:00:00

  • USCOM-window to the circulation: utility of supra-sternal Doppler in an elderly anaesthetized patient for a robotic cystectomy.

    abstract::Supra-sternal Doppler (USCOM Ltd., Sydney, Australia) can be used during anaesthesia to measure cardiac output (CO) and related flow parameters. However, before the USCOM can be used routinely, its utility and limitations need to be fully understood and critical information about its use disseminated. In "Window to th...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-013-9499-5

    authors: Critchley LA,Huang L

    更新日期:2014-02-01 00:00:00

  • Non-invasive bladder volume measurement for the prevention of postoperative urinary retention: validation of two ultrasound devices in a clinical setting.

    abstract::Ultrasound scanning of bladder volume is used for prevention of postoperative urinary retention (POUR). Accurate assessment of bladder volume is needed to allow clinical decision-making regarding the need for postoperative catheterization. Two commonly used ultrasound devices, the BladderScan® BVI 9400 and the newly r...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-018-0123-6

    authors: Brouwer TA,van den Boogaard C,van Roon EN,Kalkman CJ,Veeger N

    更新日期:2018-12-01 00:00:00

  • Utility of near infrared light to determine tissue oxygenation during hepato-biliary surgery.

    abstract::Near-infrared spectrophotometry assesses cerebral oxygen saturation (ScO2) based on the absorption spectra of oxygenated and deoxygenated hemoglobin, and the translucency of biological tissue, in the near-infrared band. There is increasing evidence that optimising cerebral oxygenation, guided by ScO2, is associated wi...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-014-9642-y

    authors: Murphy N,Fröhlich S,Kong T,Boylan JF,Conlon N

    更新日期:2015-10-01 00:00:00

  • Bench test assessment of mainstream capnography during high frequency oscillatory ventilation.

    abstract::To assess the feasibility, stability and predictability of pCO2 measurement (PETCO2) using a main stream capnograph in a high frequency oscillatory ventilation circuit. A commercially available capnograph was mounted into a high frequency oscillatory ventilator patient circuit, adjustable CO2 flow was introduced into ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-013-9495-9

    authors: Hartdorff CM,van Heerde M,Markhorst DG

    更新日期:2014-02-01 00:00:00