Novel hand-held device for exhaled nitric oxide-analysis in research and clinical applications.

Abstract:

:Changes in expired nitric oxide (NO) occur in airway inflammation and have proved to be important in the monitoring of inflammatory disease processes such as asthma. We set out to develop a novel hand-held NO-analyzer with a performance comparable to the present more costly and complex chemiluminescence instruments. The new device is based on a specially designed electrochemical sensor, where we have developed a novel sampling and analysis technology, compensating for the relatively slow response properties of the electrochemical sensor technique. A Lowest Detection Limit in NO-analysis from reference gas tests of less than 3 ppb and a response time of 15 seconds together with an average precision in human breath measurements of 1.4 ppb were obtained. We also show an agreement with the existing 'gold standard' FENO measurement technique, within 0.5 ppb in a group of 19 subjects together with a high linearity and accuracy compared to reference gases. The new analyzer enables affordable monitoring of inflammatory airway diseases in research and routine clinical practice.

journal_name

J Clin Monit Comput

authors

Hemmingsson T,Linnarsson D,Gambert R

doi

10.1007/s10877-005-1158-z

subject

Has Abstract

pub_date

2004-12-01 00:00:00

pages

379-87

issue

5-6

eissn

1387-1307

issn

1573-2614

journal_volume

18

pub_type

杂志文章
  • Respiratory and non-respiratory sinus arrhythmia: implications for heart rate variability.

    abstract::The quantity of blood arriving at the left side of the heart oscillates throughout the breathing cycle due to the mechanics of breathing. Neurally regulated fluctuations in the length of the heart period act to dampen oscillations of the left ventricular stroke volume entering the aorta. We have reported that stroke v...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-011-9327-8

    authors: McMullen MK,Whitehouse JM,Shine G,Towell A

    更新日期:2012-02-01 00:00:00

  • Prediction of difficult laryngoscopy using spirometry: a pilot study.

    abstract::Prediction of difficult laryngoscopy is still the uncovered secret of anesthetic practice. This pilot study is aimed to assess the efficacy of spirometry measurements in predicting difficult laryngoscopy compared with conventional airway assessment techniques. We enrolled 202 adults, ages 18-40 years, with an American...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-016-9961-2

    authors: Dogru S,Karaman T,Sahin A,Tapar H,Karaman S,Arici S,Suren M,Kaya Z,Somuk BT

    更新日期:2017-12-01 00:00:00

  • Study of light transmission through gauze pad effected by blood or liquids to detect needle dislodgement.

    abstract:OBJECTIVE:Serious accidents during hemodialysis such as a large amount of blood loss are often caused by venous needle dislodgement. To develop a bleeding sensor based on a photo sensor for monitoring the needle sites, we studied effects of liquids and porcine blood on light transmission through a thin gauze pad with a...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-009-9206-8

    authors: Takeuchi A,Ishida K,Morohoshi Y,Shinbo T,Hirose M,Ikeda N

    更新日期:2010-02-01 00:00:00

  • Cardiac output measurement by pulse dye densitometry: comparison with pulmonary artery thermodilution in post-cardiac surgery patients.

    abstract:OBJECTIVE:Pulse-dye densitometry (PDD) could be a suitable, low-invasive alternative to thermodilution using a pulmonary artery catheter (PAC) for monitoring cardiac output. The aim of our study was to assess the reproducibility and validity of PDD compared to PAC-thermodilution. METHODS:In 43 post-cardiac surgery pat...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-005-6865-y

    authors: Kroon M,Groeneveld AB,Smulders YM

    更新日期:2005-12-01 00:00:00

  • Multicenter evaluation of noninvasive cardiac output measurement by bioreactance technique.

    abstract:OBJECTIVES:Bioreactance, the analysis of intrabeat variations in phase of a transthoracic voltage in response to an applied high frequency transthoracic current, was recently introduced for noninvasive cardiac output measurement (NICOM). We evaluated NICOM compared to thermo- dilution (TD) in several clinical settings....

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s10877-008-9112-5

    authors: Raval NY,Squara P,Cleman M,Yalamanchili K,Winklmaier M,Burkhoff D

    更新日期:2008-04-01 00:00:00

  • Ventilation monitoring during moderate sedation in GI patients.

    abstract::Sedation in locations outside the operating room (OR) is common. Guidelines for safe patient monitoring have been updated by the American Society of Anesthesiology to include monitoring of ventilation and/or carbon dioxide (CO2). Although technologies exist to monitor these variables, the quality and/or availability o...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-015-9809-1

    authors: Ebert TJ,Middleton AH,Makhija N

    更新日期:2017-02-01 00:00:00

  • Functional residual capacity measurement during tracheal gas insufflation.

    abstract:OBJECTIVE:Tracheal gas insufflation (TGI) is considered an adjunctive method to enhance carbon dioxide elimination during permissive hypercapnia in patients with acute respiratory distress syndrome. Due to increasing tidal volume and/or expiratory resistance, TGI may cause intrinsic PEEP (PEEPi), and may lessen the adv...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009998100819

    authors: Fujino Y,Nishimura M,Hirao O,Taenaka N,Yoshiya I

    更新日期:1998-05-01 00:00:00

  • Laser speckle contrast imaging for quantitative assessment of facial flushing during mesenteric traction syndrome in upper gastrointestinal surgery.

    abstract::The mesenteric traction syndrome (MTS) is associated with prostacyclin (PGI2) facilitated systemic vasodilatation during surgery and is identified by facial flushing. We hypothesized that severe facial flushing would be related to the highest concentrations of plasma PGI2 and accordingly to the highest levels of skin ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-018-0226-0

    authors: Ring LL,Strandby RB,Henriksen A,Ambrus R,Sørensen H,Gøtze JP,Svendsen LB,Achiam MP

    更新日期:2019-10-01 00:00:00

  • Risk factors for positioning-related somatosensory evoked potential changes in 3946 spinal surgeries.

    abstract::The goal of this study was to evaluate the risk factors associated with positioning-related SSEP changes (PRSC). The study investigated the association between 18 plausible risk factors and the occurrence of intraoperative PRSC. Risk factors investigated included demographic variables, comorbidities, and procedure rel...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-018-0148-x

    authors: Melachuri SR,Balzer JR,Melachuri MK,Ninaci D,Anetakis K,Kaur J,Crammond DJ,Thirumala PD

    更新日期:2019-04-01 00:00:00

  • Utility of near infrared light to determine tissue oxygenation during hepato-biliary surgery.

    abstract::Near-infrared spectrophotometry assesses cerebral oxygen saturation (ScO2) based on the absorption spectra of oxygenated and deoxygenated hemoglobin, and the translucency of biological tissue, in the near-infrared band. There is increasing evidence that optimising cerebral oxygenation, guided by ScO2, is associated wi...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-014-9642-y

    authors: Murphy N,Fröhlich S,Kong T,Boylan JF,Conlon N

    更新日期:2015-10-01 00:00:00

  • Impact of non invasive and beat-to-beat arterial pressure monitoring on intraoperative hemodynamic management.

    abstract::The Nexfin device allows for non-invasive beat-to-beat blood pressure monitoring (BP(NXF)). Perioperative hypotension and hypertension have been shown to be associated with poor clinical outcomes. The goal of the present study was to assess the ability of this device to decrease the duration of significant intraoperat...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-012-9344-2

    authors: Chen G,Chung E,Meng L,Alexander B,Vu T,Rinehart J,Cannesson M

    更新日期:2012-04-01 00:00:00

  • Cutaneous mitochondrial respirometry: non-invasive monitoring of mitochondrial function.

    abstract::The recently developed technique for measuring cutaneous mitochondrial oxygen tension (mitoPO2) by means of the Protoporphyrin IX-Triplet State Lifetime Technique (PpIX-TSLT) provides new opportunities for assessing mitochondrial function in vivo. The aims of this work were to study whether cutaneous mitochondrial mea...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-014-9628-9

    authors: Harms FA,Bodmer SI,Raat NJ,Mik EG

    更新日期:2015-08-01 00:00:00

  • USCOM-window to the circulation: utility of supra-sternal Doppler in an elderly anaesthetized patient for a robotic cystectomy.

    abstract::Supra-sternal Doppler (USCOM Ltd., Sydney, Australia) can be used during anaesthesia to measure cardiac output (CO) and related flow parameters. However, before the USCOM can be used routinely, its utility and limitations need to be fully understood and critical information about its use disseminated. In "Window to th...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-013-9499-5

    authors: Critchley LA,Huang L

    更新日期:2014-02-01 00:00:00

  • Non-invasive bladder volume measurement for the prevention of postoperative urinary retention: validation of two ultrasound devices in a clinical setting.

    abstract::Ultrasound scanning of bladder volume is used for prevention of postoperative urinary retention (POUR). Accurate assessment of bladder volume is needed to allow clinical decision-making regarding the need for postoperative catheterization. Two commonly used ultrasound devices, the BladderScan® BVI 9400 and the newly r...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-018-0123-6

    authors: Brouwer TA,van den Boogaard C,van Roon EN,Kalkman CJ,Veeger N

    更新日期:2018-12-01 00:00:00

  • Simulating physiological interactions in a hybrid system of mathematical models.

    abstract::Mathematical models can be deployed to simulate physiological processes of the human organism. Exploiting these simulations, reactions of a patient to changes in the therapy regime can be predicted. Based on these predictions, medical decision support systems (MDSS) can help in optimizing medical therapy. An MDSS desi...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-013-9502-1

    authors: Kretschmer J,Haunsberger T,Drost E,Koch E,Möller K

    更新日期:2014-12-01 00:00:00

  • Effects of inspired oxygen concentration during emergence from general anaesthesia on postoperative lung impedance changes evaluated by electrical impedance tomography: a randomised controlled trial.

    abstract::We evaluated the effects of three different inspired oxygen concentrations (40%, 80%, and 100%) at anaesthesia emergence on postoperative lung volumes as measured by global impedance of electrical impedance tomography (EIT). This is a randomised, controlled, and assessor-blinded study in single-centre from May 2017 to...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00390-0

    authors: Park J,Lee EK,Lee JH,Oh EJ,Min JJ

    更新日期:2020-10-01 00:00:00

  • Cutaneous microcirculation in preterm neonates: comparison between sidestream dark field (SDF) and incident dark field (IDF) imaging.

    abstract::Incident dark field imaging (IDF) is a new generation handheld microscope for bedside visualization and quantification of microcirculatory alterations. IDF is the technical successor of sidestream dark field imaging (SDF), currently the most used device for microcirculatory measurements. In (pre)term neonates the redu...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-015-9708-5

    authors: van Elteren HA,Ince C,Tibboel D,Reiss IK,de Jonge RC

    更新日期:2015-10-01 00:00:00

  • Effects of prolonged ischemia on human skeletal muscle microcirculation as assessed by near-infrared spectroscopy.

    abstract::Near-infrared spectroscopy (NIRS) has been used to detect in vivo microvascular alterations by means of a vascular occlusion test. We sought to analyse by NIRS the microcirculatory profile of patients undergoing prolonged tourniquet-induced bloodless condition for extremity surgery, and compare the results with time o...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-016-9877-x

    authors: Tujjar O,De Gaudio AR,Tofani L,Di Filippo A

    更新日期:2017-06-01 00:00:00

  • A comparison of ventricular systolic function indices provided by VolumeView/EV1000™ and left ventricular ejection fraction by echocardiography among septic shock patients.

    abstract::The aim of this study was to compare the cardiac function index (CFI) and global ejection fraction (GEF) obtained by VolumeView/EV1000™, with the left ventricular ejection fraction (LVEF) by echocardiography in septic shock patients. A prospective observational study was conducted in a medical intensive care unit of a...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-018-0152-1

    authors: Nakwan N,Chichareon P,Khwannimit B

    更新日期:2019-04-01 00:00:00

  • Comparison of an ultrasound-guided technique versus a landmark-guided technique for internal jugular vein cannulation.

    abstract::Central venous cannulation is a commonly preformed procedure in many branches of medicine, particularly in anaesthesia and intensive care medicine. The purpose of this study was to compare the landmark-guided technique to the ultrasound-guided technique for internal jugular vein cannulation in cardiovascular surgery p...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10877-014-9585-3

    authors: Dolu H,Goksu S,Sahin L,Ozen O,Eken L

    更新日期:2015-02-01 00:00:00

  • A motor evoked potential trending system may discriminate outcome: retrospective application with three cases.

    abstract::This report presents a method for tracking Motor Evoked Potential (MEP) amplitudes over the course of a case using a moving least squares linear regression (LSMAs). During a case, newly obtained MEP amplitudes are compared to those predicted by a just previous linear regression (least squares moving average or LSMA). ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-018-0181-9

    authors: Jasiukaitis P,Lyon R

    更新日期:2019-06-01 00:00:00

  • Changes in cerebral and renal oxygenation during laparoscopic pyloromyotomy.

    abstract::Although a laparoscopic approach may be preferred over open procedures for abdominal surgery, there are limited data on the effect of laparoscopic procedures on cerebral and renal oxygenation in neonates and young infants. Here, we evaluated the effect in neonates and infants. In this two-center prospective observatio...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00356-2

    authors: Kamata M,Hakim M,Walia H,Tumin D,Tobias JD

    更新日期:2020-08-01 00:00:00

  • Observational study of newborn infant parasympathetic evaluation as a comfort system in awake patients admitted to a pediatric intensive care unit.

    abstract::To compare the newborn infant parasympathetic evaluation system (NIPE) scores with a validated clinical scale using two different nebulizers in children with bronchiolitis admitted to a PICU. Comfort was evaluated using the COMFORT-behavior scale (CBS) before (T1), during (T2) and after (T3) each nebulization. In orde...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10877-019-00268-1

    authors: Valencia-Ramos J,Arnaez J,Calvo S,Gomez F,Del Blanco I

    更新日期:2019-10-01 00:00:00

  • A new calibration method that compensates for the effects of O2 and N2 on infrared CO2 analysers.

    abstract:OBJECTIVE:This study evaluates a method for calibrating mainstream CO(2) analysers in which CO(2) partial pressure (P (CO2)) is calculated as a function of the outputs of CO(2) and O(2) analysers. METHODS:Three mass flow controllers were used to generate 25 different reference mixtures of O(2), N(2) and CO(2). Referen...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-005-9005-9

    authors: Tang Y,Turner MJ,Baker AB

    更新日期:2006-04-01 00:00:00

  • Capnography to check the safety of Bain circuit.

    abstract::The test of the inner tube integrity is an important checklist prior to the safe use of Bain's breathing system. This is because the major concern with the use of Bain's circuit is the potential malfunctioning of the circuit due to avulsion of the inner fresh gas delivery tube at the machine end which will turn the ou...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-009-9212-x

    authors: Kataria S,Subramanyam R

    更新日期:2010-02-01 00:00:00

  • Application of artificial neural networks as an indicator of awareness with recall during general anaesthesia.

    abstract:OBJECTIVE:Awareness with recall is a rare but serious complication of general anaesthesia with an incidence ranging from 0.1%-0.7%. In the absence of a reliable depth-of-anaesthesia monitor, attempts have been made to predict awareness from intraoperative haemodynamic monitoring data, with little success. Artificial ne...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1015426015547

    authors: Ranta SO,Hynynen M,Räsänen J

    更新日期:2002-01-01 00:00:00

  • A fully automated algorithm for the determination of respiratory rate from the photoplethysmogram.

    abstract:OBJECTIVE:To determine if an automatic algorithm using wavelet analysis techniques can be used to reliably determine respiratory rate from the photoplethysmogram (PPG). METHODS:Photoplethysmograms were obtained from 12 spontaneously breathing healthy adult volunteers. Three related wavelet transforms were automaticall...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-005-9007-7

    authors: Leonard PA,Douglas JG,Grubb NR,Clifton D,Addison PS,Watson JN

    更新日期:2006-02-01 00:00:00

  • Electrical impedance tomography's correlation to lung volume is not influenced by anthropometric parameters.

    abstract:STUDY OBJECTIVES:Electrical impedance tomography (EIT) is able to reflect physiological parameters such as real-time changes in global and regional lung volume. EIT can aid in the assessment of lung recruitment, and its use has been validated in preliminary studies monitoring mechanical ventilation at the bedside. ICU ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-006-9021-4

    authors: Marquis F,Coulombe N,Costa R,Gagnon H,Guardo R,Skrobik Y

    更新日期:2006-06-01 00:00:00

  • Bi-spectral index guided closed-loop anaesthesia delivery system (CLADS) in pheochromocytoma.

    abstract:OBJECTIVES:Anaesthetic management of pheochromocytoma is far from satisfactory even though various techniques are available. Feasibility as well as safety of Bi-spectral Index (BIS)-guided closed-loop control of anaesthesia has been shown in various clinical settings. We evaluated the performance of BIS-guided closed-l...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-009-9181-0

    authors: Hegde HV,Puri GD,Kumar B,Behera A

    更新日期:2009-08-01 00:00:00

  • Conductive heating mattress leads to ECG changes that mimic pacemaker spikes.

    abstract::Hypothermia is a common perioperative complication. To prevent perioperative hypothermia amongst other things electrical heating mattresses are used. We have made an observation with the use of an electrical heating mattress that may confuse users. In this case the ECG monitoring suddenly showed spikes that looked lik...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 信件

    doi:10.1007/s10877-020-00520-z

    authors: Bräuer A,Franke R,von Hammerstein-Equord A

    更新日期:2020-07-15 00:00:00