Multi-parameter vital sign database to assist in alarm optimization for general care units.

Abstract:

:Continual vital sign assessment on the general care, medical-surgical floor is expected to provide early indication of patient deterioration and increase the effectiveness of rapid response teams. However, there is concern that continual, multi-parameter vital sign monitoring will produce alarm fatigue. The objective of this study was the development of a methodology to help care teams optimize alarm settings. An on-body wireless monitoring system was used to continually assess heart rate, respiratory rate, SpO2 and noninvasive blood pressure in the general ward of ten hospitals between April 1, 2014 and January 19, 2015. These data, 94,575 h for 3430 patients are contained in a large database, accessible with cloud computing tools. Simulation scenarios assessed the total alarm rate as a function of threshold and annunciation delay (s). The total alarm rate of ten alarms/patient/day predicted from the cloud-hosted database was the same as the total alarm rate for a 10 day evaluation (1550 h for 36 patients) in an independent hospital. Plots of vital sign distributions in the cloud-hosted database were similar to other large databases published by different authors. The cloud-hosted database can be used to run simulations for various alarm thresholds and annunciation delays to predict the total alarm burden experienced by nursing staff. This methodology might, in the future, be used to help reduce alarm fatigue without sacrificing the ability to continually monitor all vital signs.

journal_name

J Clin Monit Comput

authors

Welch J,Kanter B,Skora B,McCombie S,Henry I,McCombie D,Kennedy R,Soller B

doi

10.1007/s10877-015-9790-8

subject

Has Abstract

pub_date

2016-12-01 00:00:00

pages

895-900

issue

6

eissn

1387-1307

issn

1573-2614

pii

10.1007/s10877-015-9790-8

journal_volume

30

pub_type

杂志文章
  • Novel hand-held device for exhaled nitric oxide-analysis in research and clinical applications.

    abstract::Changes in expired nitric oxide (NO) occur in airway inflammation and have proved to be important in the monitoring of inflammatory disease processes such as asthma. We set out to develop a novel hand-held NO-analyzer with a performance comparable to the present more costly and complex chemiluminescence instruments. T...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-005-1158-z

    authors: Hemmingsson T,Linnarsson D,Gambert R

    更新日期:2004-12-01 00:00:00

  • Journal of Clinical Monitoring and Computing 2019 end of year summary: monitoring tissue oxygenation and perfusion and its autoregulation.

    abstract::Tissue perfusion monitoring is increasingly being employed clinically in a non-invasive fashion. In this end-of-year summary of the Journal of Clinical Monitoring and Computing, we take a closer look at the papers published recently on this subject in the journal. Most of these papers focus on monitoring cerebral perf...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,评审

    doi:10.1007/s10877-020-00504-z

    authors: Sahinovic MM,Vos JJ,Scheeren TWL

    更新日期:2020-06-01 00:00:00

  • Comparison of the use of AnaConDa® versus AnaConDa-S® during the post-operative period of cardiac surgery under standard conditions of practice.

    abstract::Changes have been made to the AnaConDa device (Sedana Medical, Stockholm, Sweden), decreasing its size to reduce dead space and carbon dioxide (CO2) retention. However, this also involves a decrease in the surface area of the activated carbon filter. The CO2 elimination and sevoflurane (SEV) reflection of the old devi...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00285-0

    authors: Marcos-Vidal JM,Merino M,González R,García C,Rey S,Pérez I

    更新日期:2020-02-01 00:00:00

  • Trending algorithm discriminates hemodynamic from injury related TcMEP amplitude loss.

    abstract::Jasiukaitis and Lyon (J Clin Monit Comput, https://doi.org/10.1007/s10877-018-0181-9, 2018) described an motor evoked potential (MEP)amplitude trending system to detect MEP amplitude loss against a background of MEP variability. They found that the end of case value of a running R2 triggered by a set MEP amplitude los...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00272-5

    authors: Jasiukaitis P,Lyon R

    更新日期:2020-02-01 00:00:00

  • The sounds of saturation.

    abstract::Audible pulse tones, based on a variable-pitch frequency scale, allow the anesthesiologist to determine the patient's oxygen saturation without constant visual examination of the monitor display. The ability to reliably detect oxygen saturation levels based on audible pulse tones may be compromised when multiple pulse...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/b:jocm.0000032698.47717.06

    authors: Santamore DC,Cleaver TG

    更新日期:2004-04-01 00:00:00

  • Pretreatment with glucose-insulin-potassium improves ventricular performances after coronary artery bypass surgery: a randomized controlled trial.

    abstract::Heart failure is the main cause of poor outcome following open heart surgery and experimental studies have demonstrated that glucose-insulin-potassium (GIK) infusion exerts cardioprotective effects by reducing myocardial ischemia-reperfusion injuries. This randomized controlled trial was designed to assess the effects...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00280-5

    authors: Licker M,Reynaud T,Garofano N,Sologashvili T,Diaper J,Ellenberger C

    更新日期:2020-02-01 00:00:00

  • Automated titration of propofol and remifentanil decreases the anesthesiologist's workload during vascular or thoracic surgery: a randomized prospective study.

    abstract::Closed loop target-control infusion systems using a Bispectral (BIS) signal as an input (TCI Loop) can automatically maintain intravenous anesthesia in a BIS range of 40-60 %. Our purpose was to assess to what extent such a system could decrease anesthesia workload in comparison to the use of a stand alone TCI system ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10877-013-9453-6

    authors: Dussaussoy C,Peres M,Jaoul V,Liu N,Chazot T,Picquet J,Fischler M,Beydon L

    更新日期:2014-02-01 00:00:00

  • A simplified 4-parameter model of volumetric capnograms improves calculations of airway dead space and slope of Phase III.

    abstract::To evaluate a compact and easily interpretable 4-parameter model describing the shape of the volumetric capnogram, and the resulting estimates of anatomical dead space (VDAW) and Phase III (alveolar plateau) slope (SIII). Data from of 8 mildly-endotoxemic pre-acute respiratory distress syndrome sheep were fitted to th...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00451-4

    authors: Motta-Ribeiro GC,Vidal Melo MF,Jandre FC

    更新日期:2020-12-01 00:00:00

  • Focus on renal blood flow in mechanically ventilated patients with SARS-CoV-2: a prospective pilot study.

    abstract::Mechanically ventilated patients with ARDS due to the severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) seem particularly susceptible to AKI. Our hypothesis was that the renal blood flow could be more compromised in SARS-CoV-2 patients than in patients with "classical" ARDS. We compared the renal resistivit...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00633-5

    authors: Fogagnolo A,Grasso S,Dres M,Gesualdo L,Murgolo F,Morelli E,Ottaviani I,Marangoni E,Volta CA,Spadaro S

    更新日期:2021-01-01 00:00:00

  • EEG-derived pain threshold index for prediction of postoperative pain in patients undergoing laparoscopic urological surgery: a comparison with surgical pleth index.

    abstract::Recently a novel pain recognition indicator derived from electroencephalogram(EEG) signals, pain threshold index(PTI) has been developed. The aim of this study was to determine whether PTI can be used for prediction of postoperative acute pain while surgical pleth index(SPI) applied as control. Eighty patients undergo...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00604-w

    authors: Wang R,Deng Y,Zhou S,Zhang J

    更新日期:2020-10-12 00:00:00

  • Accuracy and trending ability of hemoglobin measurement by the Pulse CO-Oximeter during vascular surgery.

    abstract::Real time information of Hb concentration can guide a tailored patient blood management. The study investigates the accuracy, precision and trending ability of the Pulse CO-Oximeter (SpHb) and blood gas analyzer in measuring the Hb concentration, compared to hematological analysis, in surgery at high risk of hemorrhag...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00337-5

    authors: De Rosa RC,Romano GM,Abbate R,Corcione A,De Robertis E

    更新日期:2020-06-01 00:00:00

  • COVID-19: Pulse oximeters in the spotlight.

    abstract::From home to intensive care units, innovations in pulse oximetry are susceptible to improve the monitoring and management of patients developing acute respiratory failure, and particularly those with the coronavirus disease 2019 (COVID-19). They include self-monitoring of oxygen saturation (SpO2) from home, continuous...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 社论

    doi:10.1007/s10877-020-00550-7

    authors: Michard F,Shelley K,L'Her E

    更新日期:2020-06-23 00:00:00

  • In vitro performance of prefilled CO2 absorbers with the Zeus®.

    abstract::Low fresh gas flows (FGFs) decrease the use of anesthetic gases, but increase CO2 absorbent usage. CO2 absorbent usage remains poorly quantified. The goal of this study is to determine canister life of 8 commercially available CO2 absorbent prepacks with the Zeus®. Pre-packed CO2 canisters of 8 different brands were t...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-017-0088-x

    authors: Omer M,Hendrickx JFA,De Ridder S,De Houwer A,Carette R,De Cooman S,De Wolf AM

    更新日期:2018-10-01 00:00:00

  • Real-time two-dimensional and three-dimensional echocardiographic imaging of the thoracic spinal cord: a possible new window into the central neuraxis.

    abstract::Transesophageal echocardiography of the spine has been difficult to perform, and high-quality images have been difficult to obtain with earlier available technology. New capabilities in hardware and software reconstruction may allow more reliable clinical data to be obtained. We describe an initial successful attempt ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-014-9576-4

    authors: Feinglass NG,Clendenen SR,Shine TS,Martin AK,Greengrass RA

    更新日期:2015-02-01 00:00:00

  • Changes in cerebral and renal oxygenation during laparoscopic pyloromyotomy.

    abstract::Although a laparoscopic approach may be preferred over open procedures for abdominal surgery, there are limited data on the effect of laparoscopic procedures on cerebral and renal oxygenation in neonates and young infants. Here, we evaluated the effect in neonates and infants. In this two-center prospective observatio...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00356-2

    authors: Kamata M,Hakim M,Walia H,Tumin D,Tobias JD

    更新日期:2020-08-01 00:00:00

  • Closed-loop regulation of arterial pressure after acute brain death.

    abstract::The purpose of this concept study was to investigate the possibility of automatic mean arterial pressure (MAP) regulation in a porcine heart-beating brain death (BD) model. Hemodynamic stability of BD donors is necessary for maintaining acceptable quality of donated organs for transplantation. Manual stabilization is ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-017-0033-z

    authors: Soltesz K,Sjöberg T,Jansson T,Johansson R,Robertsson A,Paskevicius A,Liao Q,Qin G,Steen S

    更新日期:2018-06-01 00:00:00

  • Application of artificial neural networks as an indicator of awareness with recall during general anaesthesia.

    abstract:OBJECTIVE:Awareness with recall is a rare but serious complication of general anaesthesia with an incidence ranging from 0.1%-0.7%. In the absence of a reliable depth-of-anaesthesia monitor, attempts have been made to predict awareness from intraoperative haemodynamic monitoring data, with little success. Artificial ne...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1015426015547

    authors: Ranta SO,Hynynen M,Räsänen J

    更新日期:2002-01-01 00:00:00

  • Infrared transmission of electronic information via LAN in the operating room.

    abstract::Recent advances in technology have brought many kinds of monitoring devices into the operating room (OR). The information gathered by monitors can be channeled to the operating ward information system via a local area network (LAN). Connecting patients to monitors and monitors to the LAN, however, requires a large num...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009911208828

    authors: Hagihira S,Takashina M,Mori T,Taenaka N,Mashimo T,Yoshiya I

    更新日期:2000-01-01 00:00:00

  • A graphical object display improves anesthesiologists' performance on a simulated diagnostic task.

    abstract:OBJECTIVE:This study tests the hypothesis that a graphical object display (a data display consisting of meaningful shapes) will affect the ability of anesthesiologists to perform a diagnostic task rapidly and correctly. The diagnostic tasks studied were recognition and differentiation of five etiologies of shock--anaph...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009914019889

    authors: Blike GT,Surgenor SD,Whalen K

    更新日期:1999-01-01 00:00:00

  • Bench test assessment of mainstream capnography during high frequency oscillatory ventilation.

    abstract::To assess the feasibility, stability and predictability of pCO2 measurement (PETCO2) using a main stream capnograph in a high frequency oscillatory ventilation circuit. A commercially available capnograph was mounted into a high frequency oscillatory ventilator patient circuit, adjustable CO2 flow was introduced into ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-013-9495-9

    authors: Hartdorff CM,van Heerde M,Markhorst DG

    更新日期:2014-02-01 00:00:00

  • Comparison of cardiac output optimization with an automated closed-loop goal-directed fluid therapy versus non standardized manual fluid administration during elective abdominal surgery: first prospective randomized controlled trial.

    abstract::An intraoperative automated closed-loop system for goal-directed fluid therapy has been successfully tested in silico, in vivo and in a clinical case-control matching. This trial compared intraoperative cardiac output (CO) in patients managed with this closed-loop system versus usual practice in an academic medical ce...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10877-018-0106-7

    authors: Lilot M,Bellon A,Gueugnon M,Laplace MC,Baffeleuf B,Hacquard P,Barthomeuf F,Parent C,Tran T,Soubirou JL,Robinson P,Bouvet L,Vassal O,Lehot JJ,Piriou V

    更新日期:2018-12-01 00:00:00

  • Accuracy of ultrasound B-lines score and E/Ea ratio to estimate extravascular lung water and its variations in patients with acute respiratory distress syndrome.

    abstract::Extravascular lung water (EVLW) could increase by permeability pulmonary oedema, cardiogenic oedema, or both. Transthoracic echocardiography examination of a patient allows quantifying B-lines, originating from water-thickened interlobular septa, and the E/Ea ratio, related to pulmonary capillary wedge pressure. The a...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-014-9582-6

    authors: Bataille B,Rao G,Cocquet P,Mora M,Masson B,Ginot J,Silva S,Moussot PE

    更新日期:2015-02-01 00:00:00

  • Right ventricular function in late-onset Pompe disease.

    abstract::Pompe's disease is a glycogen storage disease (type II) characterized by inherited autosomal recessive transmission. The right ventricular (RV) function is a determinant parameter of clinical outcome in patients with heart failure. We sought to characterize the RV function using Doppler-echocardiography completed by D...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-014-9551-0

    authors: Fayssoil A,Nardi O,Annane D,Orlikowski D

    更新日期:2014-08-01 00:00:00

  • Two-site regional oxygen saturation and capnography monitoring during resuscitation after cardiac arrest in a swine pediatric ventricular fibrillatory arrest model.

    abstract:ABSTARCT:To investigate the use of two-site regional oxygen saturations (rSO2) and end tidal carbon dioxide (EtCO2) to assess the effectiveness of resuscitation and return of spontaneous circulation (ROSC). Eight mechanically ventilated juvenile swine underwent 28 ventricular fibrillatory arrests with open cardiac mass...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00291-2

    authors: Al-Subu AM,Hacker TA,Eickhoff JC,Ofori-Amanfo G,Eldridge MW

    更新日期:2020-02-01 00:00:00

  • Effects of a sigh on the respiratory mechanical properties in ali patients.

    abstract:OBJECTIVES:The application of sighs during baseline ventilation was found to improve alveolar recruitment and oxygenation in patients with acute respiratory distress syndrome (ARDS). The present investigation evaluates if respiratory mechanics can be modified by a sigh. METHODS:Ten consecutive patients with acute lung...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10877-006-9028-x

    authors: Antonaglia V,Pascotto S,Simoni LD,Zin WA

    更新日期:2006-08-01 00:00:00

  • Monitoring the microcirculation.

    abstract::One of the main goals of hemodynamic support is to preserve tissue perfusion. However issue perfusion is related more to microvascular perfusion than aortic blood flow. Monitoring the microcirculation has long been difficult. Recent technologic advances have made feasible monitoring of the microcirculation at bedside ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,评审

    doi:10.1007/s10877-012-9383-8

    authors: De Backer D,Donadello K,Cortes DO

    更新日期:2012-10-01 00:00:00

  • Estimation of pulse pressure variation and cardiac output in patients having major abdominal surgery: a comparison between a mobile application for snapshot pulse wave analysis and invasive pulse wave analysis.

    abstract::Pulse pressure variation (PPV) and cardiac output (CO) can guide perioperative fluid management. Capstesia (Galenic App, Vitoria-Gasteiz, Spain) is a mobile application for snapshot pulse wave analysis (PWAsnap) and estimates PPV and CO using pulse wave analysis of a snapshot of the arterial blood pressure waveform di...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00572-1

    authors: Hoppe P,Gleibs F,Briesenick L,Joosten A,Saugel B

    更新日期:2020-08-04 00:00:00

  • A mathematical model for predicting intracranial pressure based on noninvasively acquired PC-MRI parameters in communicating hydrocephalus.

    abstract::To develop and validate a mathematical model for predicting intracranial pressure (ICP) noninvasively using phase-contrast cine MRI (PC-MRI). We performed a retrospective analysis of PC-MRI from patients with communicating hydrocephalus (n = 138). The patients were recruited from Shenzhen Second People's Hospital betw...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00598-5

    authors: Long J,Sun D,Zhou X,Huang X,Hu J,Xia J,Yang G

    更新日期:2020-10-01 00:00:00

  • Comparison of cardiac output determined by bioimpedance and bioreactance methods at rest and during exercise.

    abstract::Bioreactance is a novel non-invasive method for cardiac output measurement that involves the analysis of blood flow-dependent changes in the phase shifts of electrical currents applied across the chest. The present study (1) compared resting and exercise cardiac outputs determined by bioreactance and bioimpedance meth...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-012-9334-4

    authors: Jakovljevic DG,Moore S,Hallsworth K,Fattakhova G,Thoma C,Trenell MI

    更新日期:2012-04-01 00:00:00

  • Continuous hemoglobin and plethysmography variability index monitoring can modify blood transfusion practice and is associated with lower mortality.

    abstract::To determine the effect of implementing an algorithm of fluid and blood administration based on continuous monitoring of hemoglobin (SpHb) and PVI (plethysmography variability index) on mortality and transfusion on a whole hospital scale. This single-center quality program compared transfusion at 48 h and mortality at...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00367-z

    authors: Cros J,Dalmay F,Yonnet S,Charpentier M,Tran-Van-Ho J,Renaudeau F,Drouet A,Guilbaut P,Marin B,Nathan N

    更新日期:2020-08-01 00:00:00