Surrogate indices of aortic peak systolic velocity variation to monitor fluid responsiveness in pediatric non-cardiac surgery: a prospective observational study.

Abstract:

:Aortic peak systolic velocity variation (ΔVpeakAo) is a reliable dynamic indicator of preload in mechanically ventilated children. However, easily measurable alternative parameters like carotid peak systolic velocity variation (ΔVpeakCa) and suprasternal peak systolic velocity variation (ΔVpeakSs) are not well evaluated in children. The aim of the study was to find correlation between ΔVpeakCa and ΔVpeakSs to ΔVpeakAo, as potential surrogate markers of fluid responsiveness. 52 children, 1-12 years old, undergoing major non-cardiac surgeries under general endotracheal anaesthesia were recruited for this single-centre prospective observational study. ΔVpeakAo, ΔVpeakCa and ΔVpeakSs were measured by pulsed wave Doppler in appropriate windows, measuring maximum and minimum peak flow velocity over a single respiratory cycle. Calculated parameters were compared by a repeated measures study design. Correlation coefficients were 0.82 between ΔVpeakAo and ΔVpeakSs and 0.73 between ΔVpeakAo and ΔVpeakCa. Bland-Altman analysis showed minimal bias of 1.86 percentage points with limits of agreement of 11.21 to - 7.49 (ΔVpeakAo and ΔVpeakSs) and 3.93 percentage points with limits of agreement of 14.04 to - 6.18 (ΔVpeakAo and ΔVpeakCa). ΔVpeakSs and ΔVpeakCa also showed good discrimination to predict ΔVpeakAo (lying in previously validated fluid responsive zones) with sensitivities and specificities of 82.25% and 85% with cut-off of 11% for ΔVpeakSs, and 88.52% and 70% with cut-off of 8.6% for ΔVpeakCa. Carotid peak systolic velocity variation (ΔVpeakCa) and suprasternal peak systolic velocity variation (ΔVpeakCa) can be potential surrogate markers for Aortic peak systolic velocity variation (ΔVpeakAo) in assessing fluid responsiveness in mechanically ventilated children.Study registration: Clinicaltrials.gov ID NCT03155555.

journal_name

J Clin Monit Comput

authors

Niyogi SG,Sen IM,Jayant A,Mandal B,Bhardwaj N,Yaddanapudi S,Mathew P

doi

10.1007/s10877-019-00431-8

subject

Has Abstract

pub_date

2020-12-01 00:00:00

pages

1159-1166

issue

6

eissn

1387-1307

issn

1573-2614

pii

10.1007/s10877-019-00431-8

journal_volume

34

pub_type

杂志文章
  • EEG-derived pain threshold index for prediction of postoperative pain in patients undergoing laparoscopic urological surgery: a comparison with surgical pleth index.

    abstract::Recently a novel pain recognition indicator derived from electroencephalogram(EEG) signals, pain threshold index(PTI) has been developed. The aim of this study was to determine whether PTI can be used for prediction of postoperative acute pain while surgical pleth index(SPI) applied as control. Eighty patients undergo...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00604-w

    authors: Wang R,Deng Y,Zhou S,Zhang J

    更新日期:2020-10-12 00:00:00

  • Endotracheal tube inflation tubing defect: an unusual cause of intraoperative volume leak.

    abstract::Loss of endotracheal cuff pressure can lead to airway compromise and loss of volume delivery in mechanical ventilation requiring immediate intervention. A 40 years old male posted for bilateral interpositional arthroplasty was intubated nasally with 7.5 mm flexometallic endotracheal tube. In the intraoperative period ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 信件

    doi:10.1007/s10877-020-00607-7

    authors: Kumar A,Kumar A,Kumar N,Kumar A

    更新日期:2020-10-23 00:00:00

  • The use of heart rate variability measures as indicators of autonomic nervous modulation must be careful in patients after orthotopic heart transplantation.

    abstract::The precise relation between heart rate variability (HRV) and autonomic re-innervation has not been established explicitly in patients after orthotopic heart transplantation (OHT), but can be inferred from the fact that the HRV is reduced immediately after OHT and may increase gradually with time. The aim of this stud...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-015-9747-y

    authors: Lu WA,Chen GY,Shih CC,Kuo CD

    更新日期:2016-10-01 00:00:00

  • Head eye co-ordination using simultaneous measurement of eye in head and head in space movements: potential for use in subjects with a whiplash injury.

    abstract:OBJECTIVE:Describe reproducibility of a measurement method to investigate deficits in eye-head co-ordination. METHODS:Combined recordings of head and eye rotation using wireless motion sensors and electro-oculography (EOG) were used as an initial step towards a method to quantify eye-head co-ordination deficits. Head ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-009-9160-5

    authors: Grip H,Jull G,Treleaven J

    更新日期:2009-02-01 00:00:00

  • Focus on renal blood flow in mechanically ventilated patients with SARS-CoV-2: a prospective pilot study.

    abstract::Mechanically ventilated patients with ARDS due to the severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) seem particularly susceptible to AKI. Our hypothesis was that the renal blood flow could be more compromised in SARS-CoV-2 patients than in patients with "classical" ARDS. We compared the renal resistivit...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00633-5

    authors: Fogagnolo A,Grasso S,Dres M,Gesualdo L,Murgolo F,Morelli E,Ottaviani I,Marangoni E,Volta CA,Spadaro S

    更新日期:2021-01-01 00:00:00

  • Transoesophageal Doppler monitoring for fluid and hemodynamic treatment during lung surgery.

    abstract:INTRODUCTION:Patients undergoing lung resection are vulnerable to fluid overhydration. Recently, goal-directed fluid therapy using transoesophageal Doppler monitoring (TDM) has been shown to improve postoperative clinical outcome. The aim of this study was to assess the feasibility of TDM during open-chest procedures f...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-008-9144-x

    authors: Diaper J,Ellenberger C,Villiger Y,Robert J,Tschopp JM,Licker M

    更新日期:2008-10-01 00:00:00

  • Observational study of newborn infant parasympathetic evaluation as a comfort system in awake patients admitted to a pediatric intensive care unit.

    abstract::To compare the newborn infant parasympathetic evaluation system (NIPE) scores with a validated clinical scale using two different nebulizers in children with bronchiolitis admitted to a PICU. Comfort was evaluated using the COMFORT-behavior scale (CBS) before (T1), during (T2) and after (T3) each nebulization. In orde...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10877-019-00268-1

    authors: Valencia-Ramos J,Arnaez J,Calvo S,Gomez F,Del Blanco I

    更新日期:2019-10-01 00:00:00

  • The incidence and interpretation of large differences in EIT-based measures for PEEP titration in ARDS patients.

    abstract::Positive end-expiratory pressure (PEEP) can be titrated by electrical impedance tomography (EIT). The aim of the present study was to examine the performance of different EIT measures during PEEP trials with the aim of identifying "optimum" PEEP and to provide possible interpretations of largely diverging results. Aft...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00396-8

    authors: Zhao Z,Lee LC,Chang MY,Frerichs I,Chang HT,Gow CH,Hsu YL,Möller K

    更新日期:2020-10-01 00:00:00

  • Bilobed splitting of median nerve somatosensory evoked p14 potential under deep hypothermia.

    abstract:OBJECTIVE:To further elucidate temperature related changes in subcortical components of somatosensory evoked potentials (SEP) in intraoperative monitoring. METHODS:Intraoperative monitoring of subcortical median nerve SEP under deep hypothermia is described in a patient undergoing intracranial giant aneurysm surgery. ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1020792729242

    authors: Wagner W

    更新日期:2002-04-01 00:00:00

  • A graphical object display improves anesthesiologists' performance on a simulated diagnostic task.

    abstract:OBJECTIVE:This study tests the hypothesis that a graphical object display (a data display consisting of meaningful shapes) will affect the ability of anesthesiologists to perform a diagnostic task rapidly and correctly. The diagnostic tasks studied were recognition and differentiation of five etiologies of shock--anaph...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009914019889

    authors: Blike GT,Surgenor SD,Whalen K

    更新日期:1999-01-01 00:00:00

  • Non-invasive electrical cardiometry cardiac output monitoring during prehospital helicopter emergency medical care: a feasibility study.

    abstract:PURPOSE:Introducing advanced hemodynamic monitoring might be beneficial during Helicopter Emergency Medical Service (HEMS) care. However, it should not increase the on-scene-time, it should be easy to use and should be non-invasive. The goal of this study was to investigate the feasibility of non-invasive cardiac outpu...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-021-00657-5

    authors: Slagt C,Servaas S,Ketelaars R,van Geffen GJ,Tacken MCT,Verrips CA,Baggen LAM,Scheffer GJ,van Eijk LT

    更新日期:2021-01-23 00:00:00

  • The effect of compliance with a perioperative goal-directed therapy protocol on outcomes after high-risk surgery: a before-after study.

    abstract::Perioperative goal-directed therapy is considered to improve patient outcomes after high-risk surgery. The association of compliance with perioperative goal-directed therapy protocols and postoperative outcomes is unclear. The purpose of this study is to determine the effect of protocol compliance on postoperative out...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00585-w

    authors: Boekel MF,Venema CS,Kaufmann T,van der Horst ICC,Vos JJ,Scheeren TWL

    更新日期:2020-09-12 00:00:00

  • A monitor for Cellular Oxygen METabolism (COMET): monitoring tissue oxygenation at the mitochondrial level.

    abstract::After introduction of the protoporphyrin IX-triplet state lifetime technique as a new method to measure mitochondrial oxygen tension in vivo, the development of a clinical monitor was started. This monitor is the "COMET", an acronym for Cellular Oxygen METabolism. The COMET is a non-invasive electrically powered optic...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-016-9966-x

    authors: Ubbink R,Bettink MAW,Janse R,Harms FA,Johannes T,Münker FM,Mik EG

    更新日期:2017-12-01 00:00:00

  • Respiratory and non-respiratory sinus arrhythmia: implications for heart rate variability.

    abstract::The quantity of blood arriving at the left side of the heart oscillates throughout the breathing cycle due to the mechanics of breathing. Neurally regulated fluctuations in the length of the heart period act to dampen oscillations of the left ventricular stroke volume entering the aorta. We have reported that stroke v...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-011-9327-8

    authors: McMullen MK,Whitehouse JM,Shine G,Towell A

    更新日期:2012-02-01 00:00:00

  • Application of artificial neural networks as an indicator of awareness with recall during general anaesthesia.

    abstract:OBJECTIVE:Awareness with recall is a rare but serious complication of general anaesthesia with an incidence ranging from 0.1%-0.7%. In the absence of a reliable depth-of-anaesthesia monitor, attempts have been made to predict awareness from intraoperative haemodynamic monitoring data, with little success. Artificial ne...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1015426015547

    authors: Ranta SO,Hynynen M,Räsänen J

    更新日期:2002-01-01 00:00:00

  • Monitoring of breathing phases using a bioacoustic method in healthy awake subjects.

    abstract:OBJECTIVE:To test the ability of a microphone recording system, located distal to the respiratory outflow tract, to track the timing of the inspiratory and expiratory phases of breathing in awake healthy subjects. METHODS:Fifteen subjects participated. Breath sounds were recorded using a microphone embedded in a face ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10877-011-9307-z

    authors: Alshaer H,Fernie GR,Bradley TD

    更新日期:2011-10-01 00:00:00

  • The sounds of saturation.

    abstract::Audible pulse tones, based on a variable-pitch frequency scale, allow the anesthesiologist to determine the patient's oxygen saturation without constant visual examination of the monitor display. The ability to reliably detect oxygen saturation levels based on audible pulse tones may be compromised when multiple pulse...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/b:jocm.0000032698.47717.06

    authors: Santamore DC,Cleaver TG

    更新日期:2004-04-01 00:00:00

  • Computerized recording of neuromuscular monitoring and the risk of residual paralysis at the time of extubation.

    abstract:OBJECTIVE:We tested whether a newly installed neuromuscular monitoring device (NMT) with a computerized anesthesia recording system, incorporated in all anesthesia stations, could enhance the commitment to objective neuromuscular monitoring in a teaching hospital anesthesia department. METHODS:After 6 months of famili...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-008-9135-y

    authors: Motamed C,Bourgain JL

    更新日期:2008-08-01 00:00:00

  • Cricoid-mental distance-based versus weight-based criteria for size selection of classic laryngeal mask airway in adults: a randomized controlled study.

    abstract::The optimal size selection of laryngeal mask airway (LMA) based on body weight is not always applicable. This study was prospectively conducted to evaluate the efficacy of cricoid-mental distance-based method versus weight-based method in optimal size selection of LMA in adults. Seventy-four patients (aged from 18 to ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10877-019-00308-w

    authors: Zhu Y,Shen W,Lin Y,Huang T,Xie L,Yang Y,Chen H,Gan X

    更新日期:2019-10-01 00:00:00

  • Dynamic prediction of the need for renal replacement therapy in intensive care unit patients using a simple and robust model.

    abstract::We aimed at identifying a model that dynamically predicts future need for renal replacement therapy (RRT) in intensive care unit (ICU) patients and can easily be implemented for online monitoring at the bedside. 7290 interdisciplinary ICU admissions were investigated. Patients with <3 days of stay or RRT in the first ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-015-9814-4

    authors: Erdfelder F,Grigutsch D,Hoeft A,Reider E,Matot I,Zenker S

    更新日期:2017-02-01 00:00:00

  • Ventilator-associated pneumonia: current status and future recommendations.

    abstract:OBJECTIVE:Ventilator-associated pneumonia (VAP) is a common hazardous complication in ICU patients. The aim of the current review is to give an update on the current status and future recommendations for VAP prevention. METHODS:This article gives an updated review of the current literature on VAP. The first part brief...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,meta分析,评审

    doi:10.1007/s10877-010-9228-2

    authors: Efrati S,Deutsch I,Antonelli M,Hockey PM,Rozenblum R,Gurman GM

    更新日期:2010-04-01 00:00:00

  • Determining the artifact sensitivity of recent pulse oximeters during laboratory benchmarking.

    abstract::This study aimed to investigate and compare the performance of the algorithms contained in the newest generation of pulse oximeters (Masimo SET in IVY2000, Nellcor Oxismart N-3000, Agilent M3 rev. B) against a traditional pulse oximeter (Agilent CMS rel. A.0). The benchmark was performed in an efficient and reproducib...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1011420228523

    authors: Kästle SW,Konecny E

    更新日期:2000-01-01 00:00:00

  • Erroneous continuous cardiac output by calibrated pulse contour analysis.

    abstract::Pulse contour analysis techniques are used for beat-to-beat tracking of cardiac output in critically ill patients. However, an adequate pulse pressure waveform signal and identification of the appropriate (i.e. systolic) part of the waveform by the monitor are crucial for correct calculation of continuous cardiac outp...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-013-9470-5

    authors: Grensemann J,Wappler F,Sakka SG

    更新日期:2013-10-01 00:00:00

  • Technologies and solutions for data display in the operating room.

    abstract::Recent advances in technology have led to the introduction of a variety of innovative devices, each with their own platform for data display, into the operating room (OR). While these innovative applications are expanding the traditional boundaries of the surgical space and enhancing treatment capabilities, the introd...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-006-9017-0

    authors: Bitterman N

    更新日期:2006-06-01 00:00:00

  • Are automated blood pressure monitors accurate enough to calculate the ankle brachial pressure index?

    abstract:OBJECTIVE:Conventional sphygmomanometers are being replaced by automated devices; can they be used to accurately calculate ABPI? METHOD:Thirty-six volunteers (72 legs) attending a vascular clinic had their ankle, brachial blood pressure and ABPIs calculated using each of these 3 methods. (1) Conventional aneuroid BP c...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-008-9146-8

    authors: MacDonald E,Froggatt P,Lawrence G,Blair S

    更新日期:2008-10-01 00:00:00

  • Effects of anesthetics on microvascular reactivity measured by vascular occlusion tests during off-pump coronary artery bypass surgery: a randomized controlled trial.

    abstract::Microvascular function may be modulated by various anesthetics. Desflurane and propofol anesthesia have different effects on microvascular function. However, there are few reports on the effects of sevoflurane and desflurane on microvascular function during cardiac surgery. We compared the effects of sevoflurane and d...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00587-8

    authors: Cho YJ,Yoo SJ,Nam K,Bae JY,Lee SH,Jeon Y

    更新日期:2020-09-11 00:00:00

  • Pulmonary air embolism.

    abstract::Pulmonary air embolism is a well-known consequence of surgery, trauma, diving, and aviation. This article reviews the physiological effects, means of detection and methods of prevention and treatment of pulmonary air embolism. The primary physiological effects are elevated pulmonary artery pressures, increased ventila...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,评审

    doi:10.1023/a:1011455701892

    authors: Souders JE

    更新日期:2000-01-01 00:00:00

  • Intraoperative motor evoked potential monitoring: overview and update.

    abstract::Amidst controversy about methodology and safety, intraoperative neurophysiology has entered a new era of increasingly routine transcranial and direct electrical brain stimulation for motor evoked potential (MEP) monitoring. Based on literature review and illustrative clinical experience, this tutorial aims to present ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,评审

    doi:10.1007/s10877-006-9033-0

    authors: Macdonald DB

    更新日期:2006-10-01 00:00:00

  • Continuous hemoglobin and plethysmography variability index monitoring can modify blood transfusion practice and is associated with lower mortality.

    abstract::To determine the effect of implementing an algorithm of fluid and blood administration based on continuous monitoring of hemoglobin (SpHb) and PVI (plethysmography variability index) on mortality and transfusion on a whole hospital scale. This single-center quality program compared transfusion at 48 h and mortality at...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00367-z

    authors: Cros J,Dalmay F,Yonnet S,Charpentier M,Tran-Van-Ho J,Renaudeau F,Drouet A,Guilbaut P,Marin B,Nathan N

    更新日期:2020-08-01 00:00:00

  • Cardiac output measurement by pulse dye densitometry: comparison with pulmonary artery thermodilution in post-cardiac surgery patients.

    abstract:OBJECTIVE:Pulse-dye densitometry (PDD) could be a suitable, low-invasive alternative to thermodilution using a pulmonary artery catheter (PAC) for monitoring cardiac output. The aim of our study was to assess the reproducibility and validity of PDD compared to PAC-thermodilution. METHODS:In 43 post-cardiac surgery pat...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-005-6865-y

    authors: Kroon M,Groeneveld AB,Smulders YM

    更新日期:2005-12-01 00:00:00