Real-time two-dimensional and three-dimensional echocardiographic imaging of the thoracic spinal cord: a possible new window into the central neuraxis.

Abstract:

:Transesophageal echocardiography of the spine has been difficult to perform, and high-quality images have been difficult to obtain with earlier available technology. New capabilities in hardware and software reconstruction may allow more reliable clinical data to be obtained. We describe an initial successful attempt to image the adult spinal canal, its contents, and in situ instrumentation. This report is a retrospective review of two patients in whom transesophageal echocardiography (TEE) was used to image the thoracic spine. The thoracic spine was identified and imaged with real-time 2-D and 3-D technology with location of the thoracic aorta and slight insertion and withdrawal of the TEE probe until the intervertebral discs alignment was optimized. Images of the spinal cord anatomy and its vascular supply, as well as indwelling epidural catheters were easily identified. 2-D and 3-D imaging was performed and images were recorded in digital imaging and communications in medicine format. 3-D reconstruction of images was possible with instantaneous 3-D imaging from multiple 2-D electrocardiogram-gated image acquisitions using the Phillips TEE IE-33 imaging platform. The central neuraxial cavity, including the spinal cord and the spinal nerve roots, was easily visualized, and motion of the cord was seen in a phasic pattern (with respiratory variation); cerebrospinal fluid surrounding the spinal cord was documented. The epidural space and local anesthetic drug administration through the epidural catheter were visualized, with the epidural catheter seen lying adjacent to the epidural tissue as a bright hyperechoic line. Pulsed-wave Doppler determined a biphasic pattern of blood flow in the anterior spinal artery through pulse mapping of the anatomic area. New, advanced imaging hardware and software generate clinically useful imaging of the thoracic spine in 2-D and 3-D using TEE. We believe this technology holds promise for future diagnostic and therapeutic interventions in the operating room that were previously unavailable.

journal_name

J Clin Monit Comput

authors

Feinglass NG,Clendenen SR,Shine TS,Martin AK,Greengrass RA

doi

10.1007/s10877-014-9576-4

subject

Has Abstract

pub_date

2015-02-01 00:00:00

pages

121-5

issue

1

eissn

1387-1307

issn

1573-2614

journal_volume

29

pub_type

杂志文章
  • The incidence and interpretation of large differences in EIT-based measures for PEEP titration in ARDS patients.

    abstract::Positive end-expiratory pressure (PEEP) can be titrated by electrical impedance tomography (EIT). The aim of the present study was to examine the performance of different EIT measures during PEEP trials with the aim of identifying "optimum" PEEP and to provide possible interpretations of largely diverging results. Aft...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00396-8

    authors: Zhao Z,Lee LC,Chang MY,Frerichs I,Chang HT,Gow CH,Hsu YL,Möller K

    更新日期:2020-10-01 00:00:00

  • Conductive heating mattress leads to ECG changes that mimic pacemaker spikes.

    abstract::Hypothermia is a common perioperative complication. To prevent perioperative hypothermia amongst other things electrical heating mattresses are used. We have made an observation with the use of an electrical heating mattress that may confuse users. In this case the ECG monitoring suddenly showed spikes that looked lik...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 信件

    doi:10.1007/s10877-020-00520-z

    authors: Bräuer A,Franke R,von Hammerstein-Equord A

    更新日期:2020-07-15 00:00:00

  • COVID-19: Pulse oximeters in the spotlight.

    abstract::From home to intensive care units, innovations in pulse oximetry are susceptible to improve the monitoring and management of patients developing acute respiratory failure, and particularly those with the coronavirus disease 2019 (COVID-19). They include self-monitoring of oxygen saturation (SpO2) from home, continuous...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 社论

    doi:10.1007/s10877-020-00550-7

    authors: Michard F,Shelley K,L'Her E

    更新日期:2020-06-23 00:00:00

  • A feasability study of color flow doppler vectorization for automated blood flow monitoring.

    abstract::An ongoing issue in vascular medicine is the measure of the blood flow. Catheterization remains the gold standard measurement method, although non-invasive techniques are an area of intense research. We hereby present a computational method for real-time measurement of the blood flow from color flow Doppler data, with...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-016-9953-2

    authors: Schorer R,Badoual A,Bastide B,Vandebrouck A,Licker M,Sage D

    更新日期:2017-12-01 00:00:00

  • Perioperative echocardiography-guided hemodynamic therapy in high-risk patients: a practical expert approach of hemodynamically focused echocardiography.

    abstract::The number of high-risk patients undergoing surgery is growing. To maintain adequate hemodynamic functioning as well as oxygen delivery to the vital organs (DO2) amongst this patient population, a rapid assessment of cardiac functioning is essential for the anesthesiologist. Pinpointing any underlying cardiovascular p...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,评审

    doi:10.1007/s10877-020-00534-7

    authors: Trauzeddel RF,Ertmer M,Nordine M,Groesdonk HV,Michels G,Pfister R,Reuter D,Scheeren TWL,Berger C,Treskatsch S

    更新日期:2020-05-26 00:00:00

  • Comparison between pulse wave velocities measured using Complior and measured using Biopac.

    abstract::Arterial stiffness is a reliable prognostic parameter for cardiovascular diseases. The effect of change in arterial stiffness can be measured by the change of the pulse wave velocity (PWV). The Complior system is widely used to measure PWV between the carotid and radial arteries by means of piezoelectric clips placed ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-018-0165-9

    authors: van Velzen MHN,Stolker RJ,Loeve AJ,Niehof SP,Mik EG

    更新日期:2019-04-01 00:00:00

  • Assessment of the 50 % and 95 % effective paratracheal forces for occluding the esophagus in anesthetized patients.

    abstract::This study aimed to evaluate the 50% and 95% effective paratracheal forces for occluding the esophagus in anesthetized patients. In 46 anesthetized patients, the upper esophagus was examined using ultrasonography, and the lower paratracheal area over the esophagus just above the clavicle was marked. Manual paratrachea...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-021-00652-w

    authors: Kim H,Mondal S,Choi CG,Hwang JY

    更新日期:2021-01-26 00:00:00

  • Electrical impedance tomography's correlation to lung volume is not influenced by anthropometric parameters.

    abstract:STUDY OBJECTIVES:Electrical impedance tomography (EIT) is able to reflect physiological parameters such as real-time changes in global and regional lung volume. EIT can aid in the assessment of lung recruitment, and its use has been validated in preliminary studies monitoring mechanical ventilation at the bedside. ICU ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-006-9021-4

    authors: Marquis F,Coulombe N,Costa R,Gagnon H,Guardo R,Skrobik Y

    更新日期:2006-06-01 00:00:00

  • Analgesia nociception index (ani) monitoring in patients with thoracic paravertebral block: a randomized controlled study.

    abstract::The goal of the study was to evaluate the effectiveness of analgesia nociception index (ANI) monitoring during intraoperative period for patients with thoracic paravertebral block (TPVB) undergoing breast surgery under general anesthesia. This prospective randomized trial was performed after receiving ethics committee...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10877-017-0036-9

    authors: Dundar N,Kus A,Gurkan Y,Toker K,Solak M

    更新日期:2018-06-01 00:00:00

  • Selection of cuffed endotracheal tube for children with congenital heart disease based on an ultrasound-based linear regression formula.

    abstract::It remains to be discovered whether a formula predicting the subglottic transverse diameter measured by ultrasound (SGDformula) for the selection of an appropriate endotracheal tube (ETT) for children without congenital heart disease (CHD) is useful for children with CHD. A formula for predicting SGD was established a...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-018-0203-7

    authors: Zhang K,Ma RJ,Zheng JJ,Chen YQ,Zhang MZ

    更新日期:2019-08-01 00:00:00

  • Estimation of pulse pressure variation and cardiac output in patients having major abdominal surgery: a comparison between a mobile application for snapshot pulse wave analysis and invasive pulse wave analysis.

    abstract::Pulse pressure variation (PPV) and cardiac output (CO) can guide perioperative fluid management. Capstesia (Galenic App, Vitoria-Gasteiz, Spain) is a mobile application for snapshot pulse wave analysis (PWAsnap) and estimates PPV and CO using pulse wave analysis of a snapshot of the arterial blood pressure waveform di...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00572-1

    authors: Hoppe P,Gleibs F,Briesenick L,Joosten A,Saugel B

    更新日期:2020-08-04 00:00:00

  • Effects of PEEP on the relationship between tidal volume and total impedance change measured via electrical impedance tomography (EIT).

    abstract::Electrical impedance tomography (EIT) is used in lung physiology monitoring. There is evidence that EIT is linearly associated with global tidal volume (VT) in clinically healthy patients where no positive end-expiratory pressure (PEEP) is applied. This linearity has not been challenged by altering lung conditions. Th...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-021-00651-x

    authors: Brabant O,Crivellari B,Hosgood G,Raisis A,Waldmann AD,Auer U,Adler A,Smart L,Laurence M,Mosing M

    更新日期:2021-01-25 00:00:00

  • Continuous glucose monitoring system in the operating room and intensive care unit: any difference according to measurement sites?

    abstract::Given the benefit of glucose control in the perioperative period, we evaluated the accuracy and performance of the continuous glucose monitoring system (CGMS) depending on different measurement sites in the operating room (OR) and in the intensive care unit (ICU). Patients over 18 years of age scheduled for elective s...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-015-9804-6

    authors: Song IK,Lee JH,Kang JE,Park YH,Kim HS,Kim JT

    更新日期:2017-02-01 00:00:00

  • Composite-, plain-auditory evoked potentials index and bispectral index to measure the effects of sevoflurane.

    abstract::The composite auditory evoked potentials index (cAAI) uses both cortical electroencephalogram (EEG) and response to auditory stimuli, while the bispectral index (BIS) uses only the cortical EEG and auditory evoked potentials index (AAI) uses only response to auditory stimuli. We expected that the cAAI was more useful ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10877-013-9441-x

    authors: Nishiyama T

    更新日期:2013-06-01 00:00:00

  • Correlation between preoperative somatosensory evoked potentials and intraoperative neurophysiological monitoring in spinal cord tumors.

    abstract::Intraoperative neurophysiological monitoring (IONM) is widely used in spinal cord tumors (SCTs) removal surgery. This study mainly hypothesized that patients with prolonged latency of preoperative somatosensory evoked potentials (preSEPLat) would have more deteriorated intraoperative evoked potentials. Among 506 patie...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00584-x

    authors: Park J,Cho YE,Park M,Lee J,Kim D,Park YG

    更新日期:2020-09-29 00:00:00

  • The influence of basic ventilation strategies on cerebral oxygenation in anesthetized patients without vascular disease.

    abstract:OBJECTIVES:Optimizing cerebral oxygenation is of paramount importance in certain intraoperative situations. There is, however, a paucity of published data pertaining to changes in cerebral oxygenation seen with increases in the inspired fraction of oxygen (FIO2) or end-tidal carbon dioxide (PETCO2) in anesthetized pati...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10877-010-9265-x

    authors: Picton P,Shanks A,Dorje P,Mashour GA

    更新日期:2010-12-01 00:00:00

  • Increases in voltage may produce false-negatives when using transcranial motor evoked potentials to detect an isolated nerve root injury.

    abstract:OBJECTIVE:Transcranial Motor Evoked Potentials (TcMEPs) are sometimes used during lumbar spine surgery in order to detect and prevent an intraoperative nerve root injury. Typically, a fixed stimulus is applied, and one monitors for changes in response amplitude from several myotomes. Increased stimulating voltage may o...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-010-9269-6

    authors: Lyon R,Gibson A,Burch S,Lieberman J

    更新日期:2010-12-01 00:00:00

  • Non-invasive bladder volume measurement for the prevention of postoperative urinary retention: validation of two ultrasound devices in a clinical setting.

    abstract::Ultrasound scanning of bladder volume is used for prevention of postoperative urinary retention (POUR). Accurate assessment of bladder volume is needed to allow clinical decision-making regarding the need for postoperative catheterization. Two commonly used ultrasound devices, the BladderScan® BVI 9400 and the newly r...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-018-0123-6

    authors: Brouwer TA,van den Boogaard C,van Roon EN,Kalkman CJ,Veeger N

    更新日期:2018-12-01 00:00:00

  • Bi-spectral index guided closed-loop anaesthesia delivery system (CLADS) in pheochromocytoma.

    abstract:OBJECTIVES:Anaesthetic management of pheochromocytoma is far from satisfactory even though various techniques are available. Feasibility as well as safety of Bi-spectral Index (BIS)-guided closed-loop control of anaesthesia has been shown in various clinical settings. We evaluated the performance of BIS-guided closed-l...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-009-9181-0

    authors: Hegde HV,Puri GD,Kumar B,Behera A

    更新日期:2009-08-01 00:00:00

  • Detection of intratracheal accumulation of thick secretions by using continuous monitoring of respiratory acoustic spectrum: a preliminary analysis.

    abstract::The accumulation of tracheobronchial secretions may contribute to a deterioration in pulmonary function and its early detection is important. In this study, we analyzed the respiratory sound spectrum in patients with intratracheal secretion, and compared acoustic characteristics before and after therapeutic endotrache...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00359-z

    authors: Moon YJ,Bechtel AJ,Kim SH,Kim JW,Thiele RH,Blank RS

    更新日期:2020-08-01 00:00:00

  • Computerised respiratory sounds can differentiate smokers and non-smokers.

    abstract::Cigarette smoking is often associated with the development of several respiratory diseases however, if diagnosed early, the changes in the lung tissue caused by smoking may be reversible. Computerised respiratory sounds have shown to be sensitive to detect changes within the lung tissue before any other measure, howev...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-016-9887-8

    authors: Oliveira A,Sen I,Kahya YP,Afreixo V,Marques A

    更新日期:2017-06-01 00:00:00

  • The use of heart rate variability measures as indicators of autonomic nervous modulation must be careful in patients after orthotopic heart transplantation.

    abstract::The precise relation between heart rate variability (HRV) and autonomic re-innervation has not been established explicitly in patients after orthotopic heart transplantation (OHT), but can be inferred from the fact that the HRV is reduced immediately after OHT and may increase gradually with time. The aim of this stud...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-015-9747-y

    authors: Lu WA,Chen GY,Shih CC,Kuo CD

    更新日期:2016-10-01 00:00:00

  • Cutaneous mitochondrial respirometry: non-invasive monitoring of mitochondrial function.

    abstract::The recently developed technique for measuring cutaneous mitochondrial oxygen tension (mitoPO2) by means of the Protoporphyrin IX-Triplet State Lifetime Technique (PpIX-TSLT) provides new opportunities for assessing mitochondrial function in vivo. The aims of this work were to study whether cutaneous mitochondrial mea...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-014-9628-9

    authors: Harms FA,Bodmer SI,Raat NJ,Mik EG

    更新日期:2015-08-01 00:00:00

  • Monitoring the microcirculation.

    abstract::One of the main goals of hemodynamic support is to preserve tissue perfusion. However issue perfusion is related more to microvascular perfusion than aortic blood flow. Monitoring the microcirculation has long been difficult. Recent technologic advances have made feasible monitoring of the microcirculation at bedside ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,评审

    doi:10.1007/s10877-012-9383-8

    authors: De Backer D,Donadello K,Cortes DO

    更新日期:2012-10-01 00:00:00

  • Effects of anesthetics on microvascular reactivity measured by vascular occlusion tests during off-pump coronary artery bypass surgery: a randomized controlled trial.

    abstract::Microvascular function may be modulated by various anesthetics. Desflurane and propofol anesthesia have different effects on microvascular function. However, there are few reports on the effects of sevoflurane and desflurane on microvascular function during cardiac surgery. We compared the effects of sevoflurane and d...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00587-8

    authors: Cho YJ,Yoo SJ,Nam K,Bae JY,Lee SH,Jeon Y

    更新日期:2020-09-11 00:00:00

  • Intraoperative electrode burns.

    abstract:OBJECTIVES:The purpose of this paper is to increase awareness of electrode burns that occur in the operating room (OR), to discuss their causes, warning signs, and methods that may reduce their occurrence. Two general sources of electrical burns are described: 1) Excessive radio-frequency current density usually origin...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/b:jocm.0000025254.73456.db

    authors: Russell MJ,Gaetz M

    更新日期:2004-02-01 00:00:00

  • Machine learning applied to multi-sensor information to reduce false alarm rate in the ICU.

    abstract::Studies reveal that the false alarm rate (FAR) demonstrated by intensive care unit (ICU) vital signs monitors ranges from 0.72 to 0.99. We applied machine learning (ML) to ICU multi-sensor information to imitate a medical specialist in diagnosing patient condition. We hypothesized that applying this data-driven approa...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00307-x

    authors: Hever G,Cohen L,O'Connor MF,Matot I,Lerner B,Bitan Y

    更新日期:2020-04-01 00:00:00

  • Automated titration of propofol and remifentanil decreases the anesthesiologist's workload during vascular or thoracic surgery: a randomized prospective study.

    abstract::Closed loop target-control infusion systems using a Bispectral (BIS) signal as an input (TCI Loop) can automatically maintain intravenous anesthesia in a BIS range of 40-60 %. Our purpose was to assess to what extent such a system could decrease anesthesia workload in comparison to the use of a stand alone TCI system ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10877-013-9453-6

    authors: Dussaussoy C,Peres M,Jaoul V,Liu N,Chazot T,Picquet J,Fischler M,Beydon L

    更新日期:2014-02-01 00:00:00

  • Pulmonary air embolism.

    abstract::Pulmonary air embolism is a well-known consequence of surgery, trauma, diving, and aviation. This article reviews the physiological effects, means of detection and methods of prevention and treatment of pulmonary air embolism. The primary physiological effects are elevated pulmonary artery pressures, increased ventila...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,评审

    doi:10.1023/a:1011455701892

    authors: Souders JE

    更新日期:2000-01-01 00:00:00

  • Performance of a capnodynamic method estimating effective pulmonary blood flow during transient and sustained hypercapnia.

    abstract::The capnodynamic method is a minimally invasive method continuously calculating effective pulmonary blood flow (COEPBF), equivalent to cardiac output when intra pulmonary shunt flow is low. The capnodynamic equation joined with a ventilator pattern containing cyclic reoccurring expiratory holds, provides breath to bre...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-017-0021-3

    authors: Sigmundsson TS,Öhman T,Hallbäck M,Redondo E,Sipmann FS,Wallin M,Oldner A,Hällsjö Sander C,Björne H

    更新日期:2018-04-01 00:00:00