Analgesia nociception index (ani) monitoring in patients with thoracic paravertebral block: a randomized controlled study.

Abstract:

:The goal of the study was to evaluate the effectiveness of analgesia nociception index (ANI) monitoring during intraoperative period for patients with thoracic paravertebral block (TPVB) undergoing breast surgery under general anesthesia. This prospective randomized trial was performed after receiving ethics committee approval in 44 patients who were scheduled to undergo breast surgery under general anesthesia. TPVB was performed in the preoperative period using 20 mL of bupivacaine 0.25% at T4 level. Anesthesia maintenance was provided with sevoflurane in O2: air mixture and remifentanil infusion. Intraoperative concentration of sevoflurane was adjusted according to BIS monitoring keeping the values between 40-60. In a randomized manner patients were divided into two groups. In Group control (n:22) intraoperative remifentanil infusion rate was regulated according to hemodynamic parameters, in Group ANI (n:22) remifentanil infusion rate was titrated to keep ANI monitoring values between 50-70. Total remifentanil consumption was recorded as micrograms. Demographic data, anesthesia and surgery time, intraoperative hemodynamic parameters, post-anesthesia recovery time and requirement of additional analgesic in the recovery drug were recorded. There were no significant difference in demographic data, intraoperative hemodynamic parameters, post-anesthesia recovery time and requirement of additional analgesic drug. There was a statistically significant difference between groups in total remifentanil consumption (Group ANI: 629.6 ± 422.4 mcg, Group control: 965.2 ± 543.6 mcg) (p = 0.027). In patients under general anesthesia ANI monitorisation can help optimisation of opioid consumption and provide data about nociception/antinociception intraoperatively but further experimental and clinical trials in a large scale are needed.

journal_name

J Clin Monit Comput

authors

Dundar N,Kus A,Gurkan Y,Toker K,Solak M

doi

10.1007/s10877-017-0036-9

subject

Has Abstract

pub_date

2018-06-01 00:00:00

pages

481-486

issue

3

eissn

1387-1307

issn

1573-2614

pii

10.1007/s10877-017-0036-9

journal_volume

32

pub_type

杂志文章,随机对照试验
  • A dose-response model for the conventional phototherapy of the newborn.

    abstract::Jaundice of the newborn is a common problem as a consequence of the rapid increment of blood bilirubin in the first days of live. In most cases, it is considered a physiological transient situation, but unmanaged hyperbilirubinemia can lead to death or serious injuries for the survivors. For decades, phototherapy has ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10877-006-9016-1

    authors: Osaku NO,Lopes HS

    更新日期:2006-06-01 00:00:00

  • Automated titration of propofol and remifentanil decreases the anesthesiologist's workload during vascular or thoracic surgery: a randomized prospective study.

    abstract::Closed loop target-control infusion systems using a Bispectral (BIS) signal as an input (TCI Loop) can automatically maintain intravenous anesthesia in a BIS range of 40-60 %. Our purpose was to assess to what extent such a system could decrease anesthesia workload in comparison to the use of a stand alone TCI system ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10877-013-9453-6

    authors: Dussaussoy C,Peres M,Jaoul V,Liu N,Chazot T,Picquet J,Fischler M,Beydon L

    更新日期:2014-02-01 00:00:00

  • A mathematical model for predicting intracranial pressure based on noninvasively acquired PC-MRI parameters in communicating hydrocephalus.

    abstract::To develop and validate a mathematical model for predicting intracranial pressure (ICP) noninvasively using phase-contrast cine MRI (PC-MRI). We performed a retrospective analysis of PC-MRI from patients with communicating hydrocephalus (n = 138). The patients were recruited from Shenzhen Second People's Hospital betw...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00598-5

    authors: Long J,Sun D,Zhou X,Huang X,Hu J,Xia J,Yang G

    更新日期:2020-10-01 00:00:00

  • Cricoid-mental distance-based versus weight-based criteria for size selection of classic laryngeal mask airway in adults: a randomized controlled study.

    abstract::The optimal size selection of laryngeal mask airway (LMA) based on body weight is not always applicable. This study was prospectively conducted to evaluate the efficacy of cricoid-mental distance-based method versus weight-based method in optimal size selection of LMA in adults. Seventy-four patients (aged from 18 to ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10877-019-00308-w

    authors: Zhu Y,Shen W,Lin Y,Huang T,Xie L,Yang Y,Chen H,Gan X

    更新日期:2019-10-01 00:00:00

  • Atypical "tails-up" capnograph due to breach in the sampling tube of side-stream capnometer.

    abstract:OBJECTIVE:An atypical "tails-up" capnograph pattern was noticed in a patient during the use of an accidentally crushed sampling tube with a slit-like hole. We investigated the mechanics involved in the observed capnograph pattern. METHODS:Forty consenting ASA I patients of both sexes presenting for tonsillectomy were ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009990210114

    authors: Tripathi M,Pandey M

    更新日期:2000-01-01 00:00:00

  • Predictive data mining on monitoring data from the intensive care unit.

    abstract::The widespread implementation of computerized medical files in intensive care units (ICUs) over recent years has made available large databases of clinical data for the purpose of developing clinical prediction models. The typical intensive care unit has several information sources from which data is electronically co...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-012-9416-3

    authors: Güiza F,Van Eyck J,Meyfroidt G

    更新日期:2013-08-01 00:00:00

  • Infrared transmission of electronic information via LAN in the operating room.

    abstract::Recent advances in technology have brought many kinds of monitoring devices into the operating room (OR). The information gathered by monitors can be channeled to the operating ward information system via a local area network (LAN). Connecting patients to monitors and monitors to the LAN, however, requires a large num...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009911208828

    authors: Hagihira S,Takashina M,Mori T,Taenaka N,Mashimo T,Yoshiya I

    更新日期:2000-01-01 00:00:00

  • Anti-decubitus bed mattress may interfere with cerebrovascular pressure reactivity measures due to induced ICP and ABP cyclic peaks.

    abstract::Severe traumatic brain injury (TBI) patients are monitored with continuous arterial blood pressure (ABP) and intracranial pressure (ICP). The pressure reactivity index (PRx) is a frequently used correlation coefficient between ABP and ICP to inform clinicians at the bedside about trends in global cerebrovascular press...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 信件

    doi:10.1007/s10877-020-00471-5

    authors: Jeanette T,Melisa B,Peter S,Marek C,Erta B,Ari E,Marcel A

    更新日期:2020-02-08 00:00:00

  • Intraoperative electrode burns.

    abstract:OBJECTIVES:The purpose of this paper is to increase awareness of electrode burns that occur in the operating room (OR), to discuss their causes, warning signs, and methods that may reduce their occurrence. Two general sources of electrical burns are described: 1) Excessive radio-frequency current density usually origin...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/b:jocm.0000025254.73456.db

    authors: Russell MJ,Gaetz M

    更新日期:2004-02-01 00:00:00

  • Cutaneous mitochondrial respirometry: non-invasive monitoring of mitochondrial function.

    abstract::The recently developed technique for measuring cutaneous mitochondrial oxygen tension (mitoPO2) by means of the Protoporphyrin IX-Triplet State Lifetime Technique (PpIX-TSLT) provides new opportunities for assessing mitochondrial function in vivo. The aims of this work were to study whether cutaneous mitochondrial mea...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-014-9628-9

    authors: Harms FA,Bodmer SI,Raat NJ,Mik EG

    更新日期:2015-08-01 00:00:00

  • Evaluation of a Pitot type spirometer in helium/oxygen mixtures.

    abstract:OBJECTIVE:Mixtures of helium and oxygen are regaining a place in the treatment of obstruction of the upper and lower respiratory tract. The parenchymal changes during the course of IRDS or ARDS may also benefit from the reintroduction of helium/oxygen. In order to monitor and document the effect of low-density gas mixt...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009978816071

    authors: Søndergaard S,Kárason S,Lundin S,Stenqvist O

    更新日期:1998-08-01 00:00:00

  • The influence of left lateral position on cardiac output changes after head up tilt measured by impedance cardiography.

    abstract:BACKGROUND:The value of the impedance cardiography (IC) method for measuring cardiac output (CO) with the subject in the left lateral position has not yet been established. We compared the CO after a 30 degrees head-up tilt with the subjects in the supine and left lateral position. METHODS:Thirty healthy young volunte...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009968513512

    authors: Kamenik M

    更新日期:1999-12-01 00:00:00

  • Monitoring of intratidal lung mechanics: a Graphical User Interface for a model-based decision support system for PEEP-titration in mechanical ventilation.

    abstract::In mechanical ventilation, a careful setting of the ventilation parameters in accordance with the current individual state of the lung is crucial to minimize ventilator induced lung injury. Positive end-expiratory pressure (PEEP) has to be set to prevent collapse of the alveoli, however at the same time overdistension...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s10877-014-9562-x

    authors: Buehler S,Lozano-Zahonero S,Schumann S,Guttmann J

    更新日期:2014-12-01 00:00:00

  • Machine learning applied to multi-sensor information to reduce false alarm rate in the ICU.

    abstract::Studies reveal that the false alarm rate (FAR) demonstrated by intensive care unit (ICU) vital signs monitors ranges from 0.72 to 0.99. We applied machine learning (ML) to ICU multi-sensor information to imitate a medical specialist in diagnosing patient condition. We hypothesized that applying this data-driven approa...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00307-x

    authors: Hever G,Cohen L,O'Connor MF,Matot I,Lerner B,Bitan Y

    更新日期:2020-04-01 00:00:00

  • The effect of compliance with a perioperative goal-directed therapy protocol on outcomes after high-risk surgery: a before-after study.

    abstract::Perioperative goal-directed therapy is considered to improve patient outcomes after high-risk surgery. The association of compliance with perioperative goal-directed therapy protocols and postoperative outcomes is unclear. The purpose of this study is to determine the effect of protocol compliance on postoperative out...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00585-w

    authors: Boekel MF,Venema CS,Kaufmann T,van der Horst ICC,Vos JJ,Scheeren TWL

    更新日期:2020-09-12 00:00:00

  • Monitoring of breathing phases using a bioacoustic method in healthy awake subjects.

    abstract:OBJECTIVE:To test the ability of a microphone recording system, located distal to the respiratory outflow tract, to track the timing of the inspiratory and expiratory phases of breathing in awake healthy subjects. METHODS:Fifteen subjects participated. Breath sounds were recorded using a microphone embedded in a face ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10877-011-9307-z

    authors: Alshaer H,Fernie GR,Bradley TD

    更新日期:2011-10-01 00:00:00

  • Effects of ultrasound-guided stellate-ganglion block on sleep and regional cerebral oxygen saturation in patients undergoing breast cancer surgery: a randomized, controlled, double-blinded trial.

    abstract::Numerous factors could contribute to sleep disturbances in women with breast cancer. We hypothesized that stellate ganglion block (SGB) during surgery would preserve sleep after surgery and increase intraoperative regional cerebral oxygen saturation (rSO2) on the blocked side in patients undergoing breast cancer surge...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10877-017-0074-3

    authors: Jin F,Li XQ,Tan WF,Ma H,Fang B,Tian AY,Lu HW

    更新日期:2018-10-01 00:00:00

  • Determining the artifact sensitivity of recent pulse oximeters during laboratory benchmarking.

    abstract::This study aimed to investigate and compare the performance of the algorithms contained in the newest generation of pulse oximeters (Masimo SET in IVY2000, Nellcor Oxismart N-3000, Agilent M3 rev. B) against a traditional pulse oximeter (Agilent CMS rel. A.0). The benchmark was performed in an efficient and reproducib...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1011420228523

    authors: Kästle SW,Konecny E

    更新日期:2000-01-01 00:00:00

  • A fully automated algorithm for the determination of respiratory rate from the photoplethysmogram.

    abstract:OBJECTIVE:To determine if an automatic algorithm using wavelet analysis techniques can be used to reliably determine respiratory rate from the photoplethysmogram (PPG). METHODS:Photoplethysmograms were obtained from 12 spontaneously breathing healthy adult volunteers. Three related wavelet transforms were automaticall...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-005-9007-7

    authors: Leonard PA,Douglas JG,Grubb NR,Clifton D,Addison PS,Watson JN

    更新日期:2006-02-01 00:00:00

  • Clinical evaluation of stretchable and wearable inkjet-printed strain gauge sensor for respiratory rate monitoring at different measurements locations.

    abstract::The respiration rate (RR) is a vital sign in physiological measurement and clinical diagnosis. RR can be measured using stretchable and wearable strain gauge sensors which detect the respiratory movements in the abdomen or thorax areas caused by volumetric changes. In different body locations, the accuracy of RR detec...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00481-3

    authors: Al-Halhouli A,Al-Ghussain L,El Bouri S,Liu H,Zheng D

    更新日期:2020-02-22 00:00:00

  • Cardiac output measurement by pulse dye densitometry: comparison with pulmonary artery thermodilution in post-cardiac surgery patients.

    abstract:OBJECTIVE:Pulse-dye densitometry (PDD) could be a suitable, low-invasive alternative to thermodilution using a pulmonary artery catheter (PAC) for monitoring cardiac output. The aim of our study was to assess the reproducibility and validity of PDD compared to PAC-thermodilution. METHODS:In 43 post-cardiac surgery pat...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-005-6865-y

    authors: Kroon M,Groeneveld AB,Smulders YM

    更新日期:2005-12-01 00:00:00

  • A comparison of graphical and textual presentations of time series data to support medical decision making in the neonatal intensive care unit.

    abstract:OBJECTIVE:To compare expert-generated textual summaries of physiological data with trend graphs, in terms of their ability to support neonatal Intensive Care Unit (ICU) staff in making decisions when presented with medical scenarios. METHODS:Forty neonatal ICU staff were recruited for the experiment, eight from each o...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-005-0879-3

    authors: Law AS,Freer Y,Hunter J,Logie RH,McIntosh N,Quinn J

    更新日期:2005-06-01 00:00:00

  • Non-invasive electrical cardiometry cardiac output monitoring during prehospital helicopter emergency medical care: a feasibility study.

    abstract:PURPOSE:Introducing advanced hemodynamic monitoring might be beneficial during Helicopter Emergency Medical Service (HEMS) care. However, it should not increase the on-scene-time, it should be easy to use and should be non-invasive. The goal of this study was to investigate the feasibility of non-invasive cardiac outpu...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-021-00657-5

    authors: Slagt C,Servaas S,Ketelaars R,van Geffen GJ,Tacken MCT,Verrips CA,Baggen LAM,Scheffer GJ,van Eijk LT

    更新日期:2021-01-23 00:00:00

  • Effects of a sigh on the respiratory mechanical properties in ali patients.

    abstract:OBJECTIVES:The application of sighs during baseline ventilation was found to improve alveolar recruitment and oxygenation in patients with acute respiratory distress syndrome (ARDS). The present investigation evaluates if respiratory mechanics can be modified by a sigh. METHODS:Ten consecutive patients with acute lung...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10877-006-9028-x

    authors: Antonaglia V,Pascotto S,Simoni LD,Zin WA

    更新日期:2006-08-01 00:00:00

  • Accuracy and trending ability of hemoglobin measurement by the Pulse CO-Oximeter during vascular surgery.

    abstract::Real time information of Hb concentration can guide a tailored patient blood management. The study investigates the accuracy, precision and trending ability of the Pulse CO-Oximeter (SpHb) and blood gas analyzer in measuring the Hb concentration, compared to hematological analysis, in surgery at high risk of hemorrhag...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00337-5

    authors: De Rosa RC,Romano GM,Abbate R,Corcione A,De Robertis E

    更新日期:2020-06-01 00:00:00

  • The initial tangent of the aortic pressure increase is an estimate of left ventricular contractility in pigs.

    abstract::The aim was, to identify an estimate of left ventricular contractility derived from the aortic pressure wave without load changing manoeuvres. For this purpose, left ventricular contractility was assessed with several aortic pressure wave form derived parameters and was compared to standard parameters of left ventricu...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-008-9145-9

    authors: Kisch-Wedel H,Kemming G,Meisner F,Flondor M,Bruhn S,Koehler C,Zwissler B

    更新日期:2008-10-01 00:00:00

  • Monitoring the microcirculation.

    abstract::One of the main goals of hemodynamic support is to preserve tissue perfusion. However issue perfusion is related more to microvascular perfusion than aortic blood flow. Monitoring the microcirculation has long been difficult. Recent technologic advances have made feasible monitoring of the microcirculation at bedside ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,评审

    doi:10.1007/s10877-012-9383-8

    authors: De Backer D,Donadello K,Cortes DO

    更新日期:2012-10-01 00:00:00

  • Ergonomic automated anesthesia recordkeeper using a mobile touch screen with voice navigtion.

    abstract:OBJECTIVE:To develop an ergonomically designed computerized recordkeeping tool for anesthesiologists that allows the clinician to maintain visual contact with the patient while performing recordkeeping. METHODS:To simplify the human interface software, we developed two general use software components. All purpose menu...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009972223750

    authors: Sanjo Y,Yokoyama T,Sato S,Ikeda K,Nakajima R

    更新日期:1999-08-01 00:00:00

  • The pressure exerted on the tongue during intubation with simultaneous cervical spine immobilisation: a comparison between four videolaryngoscopes and the Macintosh laryngoscope-a manikin study.

    abstract::Excessive pressures exerted on the tongue during intubation may be associated with serious complications and may make intubation more difficult. The aim of this study was to evaluate five different intubating devices in the hands of experienced anaesthetists during simulated conditions of reduced cervical spine mobili...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-017-0095-y

    authors: Aleksandrowicz D,Gaszyński T

    更新日期:2018-10-01 00:00:00

  • Bilobed splitting of median nerve somatosensory evoked p14 potential under deep hypothermia.

    abstract:OBJECTIVE:To further elucidate temperature related changes in subcortical components of somatosensory evoked potentials (SEP) in intraoperative monitoring. METHODS:Intraoperative monitoring of subcortical median nerve SEP under deep hypothermia is described in a patient undergoing intracranial giant aneurysm surgery. ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1020792729242

    authors: Wagner W

    更新日期:2002-04-01 00:00:00